Margit W. Frederiksen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Margit W. Frederiksen has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Anne Mette Madsen
National Research Centre for the Working Environment, Copenhagen Ø, Denmark
8 shared publications - John Kerr White
National Research Centre for the Working Environment, Lersø Parkallé 105, 2100 Copenhagen Ø, Denmark
3 shared publications Mika Frankel
National Research Centre for the Working Environment, Lersø Parkallé 105, 2100 Copenhagen Ø, Denmark
3 shared publicationsSaloomeh Moslehi-Jenabian
National Research Centre for the Working Environment, Lersø Parkallé 105, 2100 Copenhagen Ø, Denmark
3 shared publicationsKira Tendal
The National Research Centre for the Working Environment, Lersø Parkallé 105, DK-2100 Copenhagen Ø, Denmark
2 shared publications- Pil Uthaug Rasmussen
The National Research Centre for the Working Environment Copenhagen Denmark
2 shared publications
Latest Publications
- Open Access
- 3 July 2026
- Published by Elsevier in Atmospheric Pollution Research
- Vol. 17 (9)
Fungal and bacterial species, endotoxin, and inflammatory potential of airborne settled dust from homes
- 3 July 2026
- Published by Elsevier in Atmospheric Pollution Research
- Vol. 17 (9)
Open AccessFungal and bacterial species, endotoxin, and inflammatory potential of airborne settled dust from homes
- Open Access
- 28 May 2025
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 22 (9) , 713-725
Exposure to fungi, bacteria, and endotoxin in a museum, with staff reporting work-related symptoms
Occupational exposure to airborne fungi in indoor environments may pose respiratory health risks. This study aimed to characterize exposure to fungi, bacteria, and endotoxin in a historical museum where the staff reported airway symptoms. Air samples were collected during three separate workdays using personal and stationary samplers. Fungi and bacteria were quantified and identified using MALDI-TOF MS, and the total inflammatory potential was measured through Reactive Oxygen Species (ROS) production in a human cell line. The geometric mean of staff exposure was 5.9 × 103 CFU/m3 fungi, 1.8 × 103 CFU/m3 bacteria, and 7.93 EU/m3 endotoxin. Staff reported symptoms of the airways, with immediate symptoms upon entering two departments, which exhibited elevated fungal concentrations compared to other departments. The most prevalent fungal species were Aspergillus conicus, A. domesticus, A. pseudoglaucus, A. pseudogracilis, and Cladosporium spp. Concentrations of bacteria were highest when staff were present and without dominance by any particular species. Staff exposure and stationary samples induced ROS production in a cell line, which correlated with concentrations of fungi, bacteria, and endotoxin. Fungi were detected on the museum artifacts, and concentrations of fungi and bacteria increased during handling of the artifacts. In conclusion, staff in the two departments where airway symptoms were reported were exposed to 2 × 104 to 7 × 104 CFU/m3 of fungi, primarily Aspergillus spp. and Cladosporium. spp. This exposure constituted both xerophilic species and species commonly found in water-damaged buildings, and they seemed to have developed on artifacts. These findings underscore the importance of developing preventive strategies to protect the health of museum staff. Moreover, it highlights the challenge of managing fungi adapted to varying humidity conditions.
- 28 May 2025
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 22 (9) , 713-725
Open AccessExposure to fungi, bacteria, and endotoxin in a museum, with staff reporting work-related symptoms
Occupational exposure to airborne fungi in indoor environments may pose respiratory health risks. This study aimed to characterize exposure to fungi, bacteria, and endotoxin in a historical museum where the staff reported airway symptoms. Air samples were collected during three separate workdays using personal and stationary samplers. Fungi and bacteria were quantified and identified using MALDI-TOF MS, and the total inflammatory potential was measured through Reactive Oxygen Species (ROS) production in a human cell line. The geometric mean of staff exposure was 5.9 × 103 CFU/m3 fungi, 1.8 × 103 CFU/m3 bacteria, and 7.93 EU/m3 endotoxin. Staff reported symptoms of the airways, with immediate symptoms upon entering two departments, which exhibited elevated fungal concentrations compared to other departments. The most prevalent fungal species were Aspergillus conicus, A. domesticus, A. pseudoglaucus, A. pseudogracilis, and Cladosporium spp. Concentrations of bacteria were highest when staff were present and without dominance by any particular species. Staff exposure and stationary samples induced ROS production in a cell line, which correlated with concentrations of fungi, bacteria, and endotoxin. Fungi were detected on the museum artifacts, and concentrations of fungi and bacteria increased during handling of the artifacts. In conclusion, staff in the two departments where airway symptoms were reported were exposed to 2 × 104 to 7 × 104 CFU/m3 of fungi, primarily Aspergillus spp. and Cladosporium. spp. This exposure constituted both xerophilic species and species commonly found in water-damaged buildings, and they seemed to have developed on artifacts. These findings underscore the importance of developing preventive strategies to protect the health of museum staff. Moreover, it highlights the challenge of managing fungi adapted to varying humidity conditions.
- Open Access
- 10 June 2023
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 67 (7) , 831-846
Work in nursing homes and occupational exposure to endotoxin and bacterial and fungal species
Indoor microbial exposure may cause negative health effects. Only little is known about the occupational microbial exposure in nursing homes and the factors that influence the exposure. The exposure in nursing homes may be increased due to close contact with elderly persons who may carry infectious or antimicrobial-resistant microorganisms and due to handling of laundry, such as used clothing and bed linen. We investigated the microbial exposure in 5 nursing homes in Denmark, by use of personal bioaerosol samples from different groups of staff members taken during a typical working day, stationary bioaerosol measurements taken during various work tasks, sedimented dust samples, environmental surface swabs, and swabs from staff members’ hands. From the samples, we explored bacterial and fungal concentrations and species composition, endotoxin levels, and antimicrobial resistance in Aspergillus fumigatus isolates. Microbial concentrations from personal exposure samples differed among professions, and geometric means (GM) were 2,159 cfu/m3 (84 to 1.5 × 105) for bacteria incubated on nutrient agar, 1,745 cfu/m3 (82 to 2.0 × 104) for bacteria cultivated on a Staphylococcus selective agar, and 16 cfu/m3 air for potential pathogenic fungi incubated at 37 °C (below detection limit to 257). Bacterial exposures were elevated during bed making. On surfaces, the highest bacterial concentrations were found on bed railings. The majority of bacterial species found were related to the human skin microflora, such as different Staphylococcus and Corynebacterium species. Endotoxin levels ranged from 0.02 to 59.0 EU/m3, with a GM of 1.5 EU/m3. Of 40 tested A. fumigatus isolates, we found one multiresistant isolate, which was resistant towards both itraconazole and voriconazole, and one isolate resistant towards amphotericin B. In conclusion, we give an overview of the general microbial exposure in nursing homes and show that microbial exposures are higher for staff with more care and nursing tasks compared with administrative staff.
- 10 June 2023
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 67 (7) , 831-846
Open AccessWork in nursing homes and occupational exposure to endotoxin and bacterial and fungal species
Indoor microbial exposure may cause negative health effects. Only little is known about the occupational microbial exposure in nursing homes and the factors that influence the exposure. The exposure in nursing homes may be increased due to close contact with elderly persons who may carry infectious or antimicrobial-resistant microorganisms and due to handling of laundry, such as used clothing and bed linen. We investigated the microbial exposure in 5 nursing homes in Denmark, by use of personal bioaerosol samples from different groups of staff members taken during a typical working day, stationary bioaerosol measurements taken during various work tasks, sedimented dust samples, environmental surface swabs, and swabs from staff members’ hands. From the samples, we explored bacterial and fungal concentrations and species composition, endotoxin levels, and antimicrobial resistance in Aspergillus fumigatus isolates. Microbial concentrations from personal exposure samples differed among professions, and geometric means (GM) were 2,159 cfu/m3 (84 to 1.5 × 105) for bacteria incubated on nutrient agar, 1,745 cfu/m3 (82 to 2.0 × 104) for bacteria cultivated on a Staphylococcus selective agar, and 16 cfu/m3 air for potential pathogenic fungi incubated at 37 °C (below detection limit to 257). Bacterial exposures were elevated during bed making. On surfaces, the highest bacterial concentrations were found on bed railings. The majority of bacterial species found were related to the human skin microflora, such as different Staphylococcus and Corynebacterium species. Endotoxin levels ranged from 0.02 to 59.0 EU/m3, with a GM of 1.5 EU/m3. Of 40 tested A. fumigatus isolates, we found one multiresistant isolate, which was resistant towards both itraconazole and voriconazole, and one isolate resistant towards amphotericin B. In conclusion, we give an overview of the general microbial exposure in nursing homes and show that microbial exposures are higher for staff with more care and nursing tasks compared with administrative staff.
- Open Access
- 31 March 2023
- Published by UCL Press in UCL Open Environment
- Vol. 5, e056-12
Airborne bacterial species in indoor air and association with physical factors
The aim of this study is to obtain knowledge about which cultivable bacterial species are present in indoor air in homes, and whether the concentration and diversity of airborne bacteria are associated with different factors. Measurements have been performed for one whole year inside different rooms in five homes and once in 52 homes. Within homes, a room-to-room variation for concentrations of airborne bacteria was found, but an overlap in bacterial species was found across rooms. Eleven species were found very commonly and included: Acinetobacter lowffii, Bacillus megaterium, B. pumilus, Kocuria carniphila, K. palustris, K. rhizophila, Micrococcus flavus, M. luteus, Moraxella osloensis and Paracoccus yeei. The concentrations of Gram-negative bacteria in general and the species P. yeei were significantly associated with the season with the highest concentrations in spring. The concentrations of P. yeei, K. rhizophila and B. pumilus were associated positively with relative humidity (RH), and concentrations of K. rhizophila were associated negatively with temperature and air change rate (ACR). Micrococcus flavus concentrations were associated negatively with ACR. Overall, this study identified species which are commonly present in indoor air in homes, and that the concentrations of some species were associated with the factors: season, ACR and RH.
- 31 March 2023
- Published by UCL Press in UCL Open Environment
- Vol. 5, e056-12
Open AccessAirborne bacterial species in indoor air and association with physical factors
The aim of this study is to obtain knowledge about which cultivable bacterial species are present in indoor air in homes, and whether the concentration and diversity of airborne bacteria are associated with different factors. Measurements have been performed for one whole year inside different rooms in five homes and once in 52 homes. Within homes, a room-to-room variation for concentrations of airborne bacteria was found, but an overlap in bacterial species was found across rooms. Eleven species were found very commonly and included: Acinetobacter lowffii, Bacillus megaterium, B. pumilus, Kocuria carniphila, K. palustris, K. rhizophila, Micrococcus flavus, M. luteus, Moraxella osloensis and Paracoccus yeei. The concentrations of Gram-negative bacteria in general and the species P. yeei were significantly associated with the season with the highest concentrations in spring. The concentrations of P. yeei, K. rhizophila and B. pumilus were associated positively with relative humidity (RH), and concentrations of K. rhizophila were associated negatively with temperature and air change rate (ACR). Micrococcus flavus concentrations were associated negatively with ACR. Overall, this study identified species which are commonly present in indoor air in homes, and that the concentrations of some species were associated with the factors: season, ACR and RH.
- Open Access
- 22 February 2023
- Published by UCL Press in UCL Open Environment Preprint
Airborne bacterial species in indoor air and association with physical factors
The aim of this study is to obtain knowledge about which cultivable bacterial species are present in indoor air in homes, and whether the concentration and diversity of airborne bacteria are associated with different factors. Measurements have been performed for one whole year inside different rooms in 5 homes and once in 52 homes. Within homes, a room-to-room variation for concentrations of airborne bacteria was found, but an overlap in bacterial species was found across rooms. Eleven species were found very commonly and included: Acinetobacter lowffii, Bacillus megaterium, B. pumilus, Kocuria carniphila, K. palustris, K. rhizophila, Micrococcus flavus, M. luteus, Moraxella osloensis, and Paracoccus yeei. The concentrations of gram-negative bacteria in general and the species P. yeei were significantly associated with the season with the highest concentrations in spring. The concentrations of P. yeei, K. rhizophila, and B. pumilus were associated positively with relative humidity, and concentrations of K. rhizophila were associated negatively with temperature and air change rate. Micrococcus flavus concentrations were associated negatively with air change rate. Overall, this study identified species which are commonly present in indoor air in homes, and that the concentrations of some species were associated with the factors: season, air change rate, and relative humidity.
- 22 February 2023
- Published by UCL Press in UCL Open Environment Preprint
Open AccessAirborne bacterial species in indoor air and association with physical factors
The aim of this study is to obtain knowledge about which cultivable bacterial species are present in indoor air in homes, and whether the concentration and diversity of airborne bacteria are associated with different factors. Measurements have been performed for one whole year inside different rooms in 5 homes and once in 52 homes. Within homes, a room-to-room variation for concentrations of airborne bacteria was found, but an overlap in bacterial species was found across rooms. Eleven species were found very commonly and included: Acinetobacter lowffii, Bacillus megaterium, B. pumilus, Kocuria carniphila, K. palustris, K. rhizophila, Micrococcus flavus, M. luteus, Moraxella osloensis, and Paracoccus yeei. The concentrations of gram-negative bacteria in general and the species P. yeei were significantly associated with the season with the highest concentrations in spring. The concentrations of P. yeei, K. rhizophila, and B. pumilus were associated positively with relative humidity, and concentrations of K. rhizophila were associated negatively with temperature and air change rate. Micrococcus flavus concentrations were associated negatively with air change rate. Overall, this study identified species which are commonly present in indoor air in homes, and that the concentrations of some species were associated with the factors: season, air change rate, and relative humidity.
- Open Access
- 30 January 2023
- Published by UCL Press in UCL Open Environment Preprint
Airborne bacterial species in indoor air and association with physical factors
The aim of this study is to obtain knowledge about which cultivable bacterial species are present in indoor air in homes, and whether the concentration and species composition of airborne bacteria is associated with different factors. Measurements have been performed for one whole year inside different rooms in 5 homes and once in 52 homes. Within homes, a room-to-room variation for concentrations of airborne bacteria was found, but an overlap in bacterial species was found across rooms. Eleven species were found very commonly and included: Acinetobacter lowffii, Bacillus megaterium, B. pumilus, Kocuria carniphila, K. palustris, K. rhizophila, Micrococcus flavus, M. luteus, Moraxella osloensis, and Paracoccus yeei. The concentrations of gram-negative bacteria in general and the species P. yeei were significantly associated with the season with highest concentrations in spring. The concentrations of P. yeei, K. rhizophila, and B. pumilus were associated positively with relative humidity, and concentrations of K. rhizophila were associated negatively with temperature and air change rate. Micrococcus flavus concentrations were associated negatively with air change rate. Overall, this study identified species which are commonly present in indoor air in homes, and that the concentrations of some species were associated with the factors: season, air change rate, and relative humidity.
- 30 January 2023
- Published by UCL Press in UCL Open Environment Preprint
Open AccessAirborne bacterial species in indoor air and association with physical factors
The aim of this study is to obtain knowledge about which cultivable bacterial species are present in indoor air in homes, and whether the concentration and species composition of airborne bacteria is associated with different factors. Measurements have been performed for one whole year inside different rooms in 5 homes and once in 52 homes. Within homes, a room-to-room variation for concentrations of airborne bacteria was found, but an overlap in bacterial species was found across rooms. Eleven species were found very commonly and included: Acinetobacter lowffii, Bacillus megaterium, B. pumilus, Kocuria carniphila, K. palustris, K. rhizophila, Micrococcus flavus, M. luteus, Moraxella osloensis, and Paracoccus yeei. The concentrations of gram-negative bacteria in general and the species P. yeei were significantly associated with the season with highest concentrations in spring. The concentrations of P. yeei, K. rhizophila, and B. pumilus were associated positively with relative humidity, and concentrations of K. rhizophila were associated negatively with temperature and air change rate. Micrococcus flavus concentrations were associated negatively with air change rate. Overall, this study identified species which are commonly present in indoor air in homes, and that the concentrations of some species were associated with the factors: season, air change rate, and relative humidity.
- Open Access
- 1 January 2020
- Published by Elsevier in Waste Management
- Vol. 101, 241-249
Measures to reduce the exposure of waste collection workers to handborne and airborne microorganisms and inflammogenic dust
- 1 January 2020
- Published by Elsevier in Waste Management
- Vol. 101, 241-249
Open AccessMeasures to reduce the exposure of waste collection workers to handborne and airborne microorganisms and inflammogenic dust
- Open Access
- 1 January 2014
- Published by Elsevier in Science of The Total Environment
- Vol. 468-469, 1112-1121
Attempts to reduce exposure to fungi, β-glucan, bacteria, endotoxin and dust in vegetable greenhouses and a packaging unit
- 1 January 2014
- Published by Elsevier in Science of The Total Environment
- Vol. 468-469, 1112-1121
Open AccessAttempts to reduce exposure to fungi, β-glucan, bacteria, endotoxin and dust in vegetable greenhouses and a packaging unit