Swetha Ravichandran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Swetha Ravichandran has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Radhika Natarajan
Department of Cornea and Refractive Surgery, Sankara Nethralaya, Medical Research Foundation, Chennai, Tamil Nadu, India
2 shared publications - Amanda Vu
Blue Marble Space Institute of Science, Ames Research Center, NASA, Moffett Field, CA 94035, USA
1 shared publication Andreas Jeromin
ALZpath, Inc., Carlsbad, CA USA
1 shared publicationEdmund Arthur
University of Alabama at Birmingham, Birmingham, AL USA
1 shared publication- Edmund Arthur
School of Optometry, University of Alabama at Birmingham, Birmingham, USA
1 shared publication - Janarthanam Jothi Balaji
Department of Optometry, Medical Research Foundation, Chennai, Tamil Nadu, 600006, India
1 shared publication
Latest Publications
- Open Access
Chaotic Dynamics and Effects of Cognitive State in Human Single Neurons
How the brain balances flexibility and stability during memory-guided behavior remains unclear. While large-scale brain activity exhibits signatures of chaos, it is unknown whether individual neurons also operate in a chaotic regime, and whether such dynamics are modulated by task engagement. Here, we analyzed over 1800 medial temporal lobe (MTL) neurons recorded intracranially during a declarative memory task. Using sample entropy, correlation dimension, and the largest Lyapunov exponent, we found robust signatures of deterministic chaos in a substantial proportion of individual neurons. Crucially, these signatures were not static: during memory task engagement, neurons exhibited greater entropy and dimensionality, and lower divergence, compared to task-irrelevant periods. Chaos was widespread across MTL subregions and independent of age or gender. These results suggest that chaos is an intrinsic, dynamic feature of single-neuron activity which is selectively amplified during cognitive engagement, and may support flexible temporal coding in the human memory system.
Open AccessChaotic Dynamics and Effects of Cognitive State in Human Single Neurons
How the brain balances flexibility and stability during memory-guided behavior remains unclear. While large-scale brain activity exhibits signatures of chaos, it is unknown whether individual neurons also operate in a chaotic regime, and whether such dynamics are modulated by task engagement. Here, we analyzed over 1800 medial temporal lobe (MTL) neurons recorded intracranially during a declarative memory task. Using sample entropy, correlation dimension, and the largest Lyapunov exponent, we found robust signatures of deterministic chaos in a substantial proportion of individual neurons. Crucially, these signatures were not static: during memory task engagement, neurons exhibited greater entropy and dimensionality, and lower divergence, compared to task-irrelevant periods. Chaos was widespread across MTL subregions and independent of age or gender. These results suggest that chaos is an intrinsic, dynamic feature of single-neuron activity which is selectively amplified during cognitive engagement, and may support flexible temporal coding in the human memory system.
- Open Access
- 1 December 2024
- Published by Wiley in Alzheimer's & Dementia
- Vol. 20 (S2) , e084715
Association and multimodal model of retinal and blood‐based biomarkers for detection of preclinical Alzheimer’s disease
Background: The potential of plasma Aβ42/Aβ40 ratio, NfL, p‐tau 181, and p‐tau 217 has been extensively discussed in the literature. Our previous study explored the association between retinal biomarkers and preclinical AD. The goal of this study was to evaluate the association and a multimodal model of retinal and plasma biomarkers for detection of preclinical AD.Methods: We included 81 cognitively unimpaired (CU) participants (139 eyes; mean age: 67 years; range: 56‐80) from the Atlas of Retinal Imaging in Alzheimer's Study (ARIAS). Blood samples were assessed for concentrations of Aβ42/Aβ40 ratio, NfL, p‐tau 181, and p‐tau 217 (ALZpath, Inc.) using SIMOA technology. Spectralis II instrument was used to acquire macular centered SD‐OCT images for evaluation of putative retinal gliosis surface area and macular retinal nerve fiber layer (RNFL) thickness. A subgroup cohort of 57 eyes (32 preclinical, 25 controls; mean age: 69 vs 66, p = 0.06) were included for assessment of a multimodal model to distinguish between preclinical AD (PET Aβ+ve) and controls (PET Aβ‐ve). For all participants, partial correlations (accounting for age) were assessed between retinal and blood‐based biomarkers. For the subgroup cohort, an ROC analysis was performed to compare a multimodal model of the retinal and plasma biomarkers vs. each biomarker alone to distinguish between the two groups.Result: Significant positive partial correlation was found between putative retinal gliosis and p‐tau 217 (ρ = 0.27, p = 0.001) but not for the other plasma biomarkers. The multimodal ROC model based on retinal (gliosis area, inner inferior RNFL thickness, inner superior RNFL thickness, and inner nasal RNFL thickness) and plasma biomarkers (p‐tau 217 and Aβ42/Aβ40 ratio) had an excellent AUC of 0.97 (95% CI = 0.93 – 1.01; p < 0.001) compared to unimodal models of gliosis and RNFL thickness; AUC = 0.68 (95% CI = 0.54 – 0.82, p = 0.01), ptau 217; AUC = 0.87 (95% CI = 0.78 ‐ 0.97, p < 0.001), and Aβ42/Aβ40 ratio; AUC = 0.54 (95% CI = 0.38 – 0.70, p = 0.67).Conclusion: Our analysis shows the potential of integrating retinal and blood‐based biomarkers for improved detection and screening of preclinical AD.
- 1 December 2024
- Published by Wiley in Alzheimer's & Dementia
- Vol. 20 (S2) , e084715
Open AccessAssociation and multimodal model of retinal and blood‐based biomarkers for detection of preclinical Alzheimer’s disease
Background: The potential of plasma Aβ42/Aβ40 ratio, NfL, p‐tau 181, and p‐tau 217 has been extensively discussed in the literature. Our previous study explored the association between retinal biomarkers and preclinical AD. The goal of this study was to evaluate the association and a multimodal model of retinal and plasma biomarkers for detection of preclinical AD.Methods: We included 81 cognitively unimpaired (CU) participants (139 eyes; mean age: 67 years; range: 56‐80) from the Atlas of Retinal Imaging in Alzheimer's Study (ARIAS). Blood samples were assessed for concentrations of Aβ42/Aβ40 ratio, NfL, p‐tau 181, and p‐tau 217 (ALZpath, Inc.) using SIMOA technology. Spectralis II instrument was used to acquire macular centered SD‐OCT images for evaluation of putative retinal gliosis surface area and macular retinal nerve fiber layer (RNFL) thickness. A subgroup cohort of 57 eyes (32 preclinical, 25 controls; mean age: 69 vs 66, p = 0.06) were included for assessment of a multimodal model to distinguish between preclinical AD (PET Aβ+ve) and controls (PET Aβ‐ve). For all participants, partial correlations (accounting for age) were assessed between retinal and blood‐based biomarkers. For the subgroup cohort, an ROC analysis was performed to compare a multimodal model of the retinal and plasma biomarkers vs. each biomarker alone to distinguish between the two groups.Result: Significant positive partial correlation was found between putative retinal gliosis and p‐tau 217 (ρ = 0.27, p = 0.001) but not for the other plasma biomarkers. The multimodal ROC model based on retinal (gliosis area, inner inferior RNFL thickness, inner superior RNFL thickness, and inner nasal RNFL thickness) and plasma biomarkers (p‐tau 217 and Aβ42/Aβ40 ratio) had an excellent AUC of 0.97 (95% CI = 0.93 – 1.01; p < 0.001) compared to unimodal models of gliosis and RNFL thickness; AUC = 0.68 (95% CI = 0.54 – 0.82, p = 0.01), ptau 217; AUC = 0.87 (95% CI = 0.78 ‐ 0.97, p < 0.001), and Aβ42/Aβ40 ratio; AUC = 0.54 (95% CI = 0.38 – 0.70, p = 0.67).Conclusion: Our analysis shows the potential of integrating retinal and blood‐based biomarkers for improved detection and screening of preclinical AD.
- Open Access
Use of VESsel GENeration with Optical Coherence Tomography Angiography and Fluorescein Angiography for Detection and Quantification of Vascular Changes in Mild and Moderate Diabetic Retinopathy
(1) Background: Previously, VESsel GENeration (VESGEN) software was used to map and quantify vascular changes observed on fluorescein angiography (FA) in subjects (n = 15 eyes) with retinal pathology ranging from mild non-proliferative diabetic retinopathy (NPDR) to proliferative diabetic retinopathy (PDR). In the current study, we used VESGEN for the assessment of individuals with early-stage NPDR imaged by FA (Cohort 1) and by optical coherence tomography angiography (OCTA; Cohort 2). (2) Methods: Cohort 1 included type 2 diabetics (T2D), represented 21 eyes (ranging from no DR to moderate DR), and also included nondiabetic controls (NDC; n = 15 eyes). Cohort 2 consisted of 23 eyes from T2D subjects (including no DR subjects and moderate DR subjects) and NDC (n = 18 eyes). (3) Results: In the FA-VESGEN study, total tortuosity (Tv) of microvessels (G ≥ 6) increased in T2D with mild DR compared to the controls. In contrast, the VESGEN analysis of OCTA images showed that vessel length (characterized as density) was lower in T2D subjects before the diagnosis of DR and following the diagnosis of DR when compared to the controls. Additionally, T2D showed a significant decrease in vessel area (density). (4) Conclusions: FA elucidated the vessel morphology of small-generation microvessels to a greater degree than OCTA; however, OCTA identified changes in vessel density better than FA. VESGEN analysis can be used with both standard FA and OCTA to facilitate our understanding of early events in DR, including before the clinical diagnosis of DR.
Open AccessUse of VESsel GENeration with Optical Coherence Tomography Angiography and Fluorescein Angiography for Detection and Quantification of Vascular Changes in Mild and Moderate Diabetic Retinopathy
(1) Background: Previously, VESsel GENeration (VESGEN) software was used to map and quantify vascular changes observed on fluorescein angiography (FA) in subjects (n = 15 eyes) with retinal pathology ranging from mild non-proliferative diabetic retinopathy (NPDR) to proliferative diabetic retinopathy (PDR). In the current study, we used VESGEN for the assessment of individuals with early-stage NPDR imaged by FA (Cohort 1) and by optical coherence tomography angiography (OCTA; Cohort 2). (2) Methods: Cohort 1 included type 2 diabetics (T2D), represented 21 eyes (ranging from no DR to moderate DR), and also included nondiabetic controls (NDC; n = 15 eyes). Cohort 2 consisted of 23 eyes from T2D subjects (including no DR subjects and moderate DR subjects) and NDC (n = 18 eyes). (3) Results: In the FA-VESGEN study, total tortuosity (Tv) of microvessels (G ≥ 6) increased in T2D with mild DR compared to the controls. In contrast, the VESGEN analysis of OCTA images showed that vessel length (characterized as density) was lower in T2D subjects before the diagnosis of DR and following the diagnosis of DR when compared to the controls. Additionally, T2D showed a significant decrease in vessel area (density). (4) Conclusions: FA elucidated the vessel morphology of small-generation microvessels to a greater degree than OCTA; however, OCTA identified changes in vessel density better than FA. VESGEN analysis can be used with both standard FA and OCTA to facilitate our understanding of early events in DR, including before the clinical diagnosis of DR.
- 1 April 2022
- Published by Medknow in Indian Journal of Ophthalmology - Case Reports
- Vol. 2 (2) , 608
Fine needle diathermy for reducing corneal vascularization prior to high-risk corneal grafts
Indian Journal of Ophthalmology - Case Reports, All India Ophthalmological Society
- 1 April 2022
- Published by Medknow in Indian Journal of Ophthalmology - Case Reports
- Vol. 2 (2) , 608
Fine needle diathermy for reducing corneal vascularization prior to high-risk corneal grafts
Indian Journal of Ophthalmology - Case Reports, All India Ophthalmological Society
- 1 April 2022
- Published by Medknow in Indian Journal of Ophthalmology - Case Reports
- Vol. 2 (2) , 610
Double anterior chamber or descemet membrane detachment - Why and how to distinguish?
Indian Journal of Ophthalmology - Case Reports, All India Ophthalmological Society
- 1 April 2022
- Published by Medknow in Indian Journal of Ophthalmology - Case Reports
- Vol. 2 (2) , 610
Double anterior chamber or descemet membrane detachment - Why and how to distinguish?
Indian Journal of Ophthalmology - Case Reports, All India Ophthalmological Society
- Open Access
- 1 December 2021
- Published by ScienceOpen in ScienceOpen Preprints
COMPARISON OF EYELID ANGLE MEASURED USING MANUAL AND DIGITAL IMAGE ANALYSIS METHOD
Aim: To compare the eyelid angle measured by using a manual method (Using protractor) and digital image analysis method (Using ImageJ software) at different distances of eye gaze. Methodology: This prospective cross-sectional study was conducted in the preclinical lab at Manipal College of Health Professions. Subjects with no eyelid abnormalities were included in the study and they were asked to fixate at different distances a) at 3 metre (Distance gaze) b) at 70 cm (Intermediategaze) and c) at 40 cm(Near gaze). Using a protractor, the eyelid angle measurements were repeated at various distances which comprised the manual measurement. In the image analysis method, images were captured during distance, intermediate and near gaze using smartphone placed on theside of the face. These images were then analysed using ImageJ software for determining eyelid angle using image analysis method. Palpebral fissure height, Palpebral fissure width, Interpupillary distance, Intercanthal width, Binocular width, Height of open upper lid were some additional anthropometry measurements that were done using meter scale and PD ruler. Results: The mean age of the participants was 20±0.5 years. Anthropometry measurements of the eyelid and Palpebral fissure were done using meter scaleand PD ruler. The mean and standard deviation of the measured parametersare as follows Interpupillary distance: 60.95±2.37 mm, Endo Inter canthal distance: 32.20±2.39 mm, Exo Inter cantal distance: 95.50±3.80 mm, Palpebralfissure height_OD: 12.11±1.32 mm, Palpebral fissure height_OS:12.16±1.46mm, PFW_OD: 32.00±1.10 mm, PFW_OS: 32.11±1.24 mm, Height of upper eyelids_OD: 10.26±1.66 mm and Height of upper eyelids_OS:10.42±1.83 mm. In the right eye, there was no statistically significant difference (p>0.05) between manual protractor method and digital image analysismethod at distance but there was a statistically significant difference (pConclusion: There is a significant difference in eyelid angle measured using manual protractor method and digital image analysis method. The measurement of eyelid angle serves as a critical reference point during cosmetic and reconstructive surgical interventions of the eyelid and accurate measurements are essential for preoperative assessment, surgical planning and postoperative evaluation. Hence more studies on the validation of the anthropometry measurements and eyelid angle using digital image analysis areessential to use digital image analysis in routine eye care practice.
- 1 December 2021
- Published by ScienceOpen in ScienceOpen Preprints
Open AccessCOMPARISON OF EYELID ANGLE MEASURED USING MANUAL AND DIGITAL IMAGE ANALYSIS METHOD
Aim: To compare the eyelid angle measured by using a manual method (Using protractor) and digital image analysis method (Using ImageJ software) at different distances of eye gaze. Methodology: This prospective cross-sectional study was conducted in the preclinical lab at Manipal College of Health Professions. Subjects with no eyelid abnormalities were included in the study and they were asked to fixate at different distances a) at 3 metre (Distance gaze) b) at 70 cm (Intermediategaze) and c) at 40 cm(Near gaze). Using a protractor, the eyelid angle measurements were repeated at various distances which comprised the manual measurement. In the image analysis method, images were captured during distance, intermediate and near gaze using smartphone placed on theside of the face. These images were then analysed using ImageJ software for determining eyelid angle using image analysis method. Palpebral fissure height, Palpebral fissure width, Interpupillary distance, Intercanthal width, Binocular width, Height of open upper lid were some additional anthropometry measurements that were done using meter scale and PD ruler. Results: The mean age of the participants was 20±0.5 years. Anthropometry measurements of the eyelid and Palpebral fissure were done using meter scaleand PD ruler. The mean and standard deviation of the measured parametersare as follows Interpupillary distance: 60.95±2.37 mm, Endo Inter canthal distance: 32.20±2.39 mm, Exo Inter cantal distance: 95.50±3.80 mm, Palpebralfissure height_OD: 12.11±1.32 mm, Palpebral fissure height_OS:12.16±1.46mm, PFW_OD: 32.00±1.10 mm, PFW_OS: 32.11±1.24 mm, Height of upper eyelids_OD: 10.26±1.66 mm and Height of upper eyelids_OS:10.42±1.83 mm. In the right eye, there was no statistically significant difference (p>0.05) between manual protractor method and digital image analysismethod at distance but there was a statistically significant difference (pConclusion: There is a significant difference in eyelid angle measured using manual protractor method and digital image analysis method. The measurement of eyelid angle serves as a critical reference point during cosmetic and reconstructive surgical interventions of the eyelid and accurate measurements are essential for preoperative assessment, surgical planning and postoperative evaluation. Hence more studies on the validation of the anthropometry measurements and eyelid angle using digital image analysis areessential to use digital image analysis in routine eye care practice.