Hitesh. R. Jariwala
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hitesh. R. Jariwala has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Mukul Dixit
Department of Electrical and Electronics Engineering, College of Engineering Roorkee, Roorkee, India
2 shared publications - Prasanta Kundu
Department of Electrical Engineering SV National Institute of Technology Surat India
2 shared publications - Akanksha Shukla
Department of Electrical Engineering, Sardar Vallabhbhai National Institute of Technology, Surat 395007, Gujarat, India
1 shared publication - Chirag Rohit
Department of Electrical Engineering, SVNIT, Surat, India
1 shared publication - Kusum Verma
Malaviya National Institute of Technology Jaipur
1 shared publication - Mohammed Imran1 shared publication
Latest Publications
- Open Access
- 1 January 2025
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2025 (1)
Hybrid Control DC Microgrid Embedded With BESS and Multimode Adaptive Standalone PV
The advantages of DC distribution over AC distribution, combined with greater penetration of photovoltaic (PV) systems, have enhanced the popularity of DC microgrids. With the intermittency of a PV system, power management in a DC microgrid is an issue, but it can be addressed by using a battery energy storage system (BESS) as a backup. The goal is to maintain a constant DC‐link voltage while balancing demand and supply. The study establishes a hybrid control approach for a DC microgrid involving PV, BESS, and DC loads, utilizing both the PV system and the BESS. PV will operate as a primary voltage regulator, making BESS a secondary control, resulting in decreased battery consumption and extended battery life. To achieve this objective, a flexible power point tracking (FPPT) algorithm is suggested, which requires the PV to track the load profile by adaptively modifying its PV power output. The effectiveness of the devised control method is tested by running time domain simulations on several case studies. To assess the adapted system’s tolerance to seasonal changes, k‐means clustering is utilized to generate a cluster of irradiance profiles. These clustering solar irradiance and load profiles were simulated for 24 h to illustrate the resilience of the devised control method.
- 1 January 2025
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2025 (1)
Open AccessHybrid Control DC Microgrid Embedded With BESS and Multimode Adaptive Standalone PV
The advantages of DC distribution over AC distribution, combined with greater penetration of photovoltaic (PV) systems, have enhanced the popularity of DC microgrids. With the intermittency of a PV system, power management in a DC microgrid is an issue, but it can be addressed by using a battery energy storage system (BESS) as a backup. The goal is to maintain a constant DC‐link voltage while balancing demand and supply. The study establishes a hybrid control approach for a DC microgrid involving PV, BESS, and DC loads, utilizing both the PV system and the BESS. PV will operate as a primary voltage regulator, making BESS a secondary control, resulting in decreased battery consumption and extended battery life. To achieve this objective, a flexible power point tracking (FPPT) algorithm is suggested, which requires the PV to track the load profile by adaptively modifying its PV power output. The effectiveness of the devised control method is tested by running time domain simulations on several case studies. To assess the adapted system’s tolerance to seasonal changes, k‐means clustering is utilized to generate a cluster of irradiance profiles. These clustering solar irradiance and load profiles were simulated for 24 h to illustrate the resilience of the devised control method.
- 24 May 2023
- Published by Taylor & Francis in Smart Science
- Vol. 11 (3) , 605-628
A preordainment approach for design of auxiliary damping controller and SSSC tuning to enhance SSR mode stability in DFIG based windfarm
- 24 May 2023
- Published by Taylor & Francis in Smart Science
- Vol. 11 (3) , 605-628
A preordainment approach for design of auxiliary damping controller and SSSC tuning to enhance SSR mode stability in DFIG based windfarm
- 17 January 2019
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 42 (6) , 605-611
Techno-economic analysis-based optimal incorporation of distributed energy resources in distribution network under load uncertainty
This paper address an optimal incorporation of various distributed energy resources (DERs) i.e. wind, solar and electric vehicles (EVs) in distribution system for the purpose of minimization of total real power loss, total cost and emissions produced from grid simultaneously. To achieve these proposed objectives and benefits, a multi-objective function has been formulated. In this study, various mathematical models of DERs have been utilized for analysing the impact on distribution system under uncertain load demand of 24 hours. In addition, the charging/discharging concept of EVs during off-peak/peak hours of the grid has also taken into consideration. This non-linear and non-convex optimization task has been solved through Gbest-guided Artificial Bee Colony (GABC) optimization technique because of its robustness. However, from the obtained numerical outcomes through proposed technique, it is observed that the integration of DERs is capable for reducing total real power loss, total cost and emissions to a great value.
- 17 January 2019
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 42 (6) , 605-611
Techno-economic analysis-based optimal incorporation of distributed energy resources in distribution network under load uncertainty
This paper address an optimal incorporation of various distributed energy resources (DERs) i.e. wind, solar and electric vehicles (EVs) in distribution system for the purpose of minimization of total real power loss, total cost and emissions produced from grid simultaneously. To achieve these proposed objectives and benefits, a multi-objective function has been formulated. In this study, various mathematical models of DERs have been utilized for analysing the impact on distribution system under uncertain load demand of 24 hours. In addition, the charging/discharging concept of EVs during off-peak/peak hours of the grid has also taken into consideration. This non-linear and non-convex optimization task has been solved through Gbest-guided Artificial Bee Colony (GABC) optimization technique because of its robustness. However, from the obtained numerical outcomes through proposed technique, it is observed that the integration of DERs is capable for reducing total real power loss, total cost and emissions to a great value.
- 1 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Optimal allocation and sizing of shunt capacitor in distribution system for power loss minimization
This paper presents an optimal allocation and sizing of shunt capacitor in Radial Distribution Network (RDN) for minimizing the real power loss and total cost of the system. Loss Sensitivity Factor (LSF) approach is utilized to identify sensitive buses for capacitor placement and optimal size of shunt capacitor is determined by using Particle Swarm Optimization (PSO) algorithm and minimize the total real power loss objective function. As a result it is observed that net saving is increased, enhance the voltage profile and improve power factor after capacitor placement. The proposed approaches have been demonstrated on standard 10-bus and 34-bus radial distribution systems. The obtained numerical results of the proposed approach have been compared to the other intelligent techniques.
- 1 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Optimal allocation and sizing of shunt capacitor in distribution system for power loss minimization
This paper presents an optimal allocation and sizing of shunt capacitor in Radial Distribution Network (RDN) for minimizing the real power loss and total cost of the system. Loss Sensitivity Factor (LSF) approach is utilized to identify sensitive buses for capacitor placement and optimal size of shunt capacitor is determined by using Particle Swarm Optimization (PSO) algorithm and minimize the total real power loss objective function. As a result it is observed that net saving is increased, enhance the voltage profile and improve power factor after capacitor placement. The proposed approaches have been demonstrated on standard 10-bus and 34-bus radial distribution systems. The obtained numerical results of the proposed approach have been compared to the other intelligent techniques.