Stanislav Kamanin
Research Subjects
Stanislav Kamanin has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Vyacheslav Arlyapov
Research Center “BioChemTech”, Tula State University, Tula 300012, Russia
4 shared publications - Anatoly Nikolaevich Reshetilov
Federal Research Center (Pushchino Scientific Center for Biological Research of the Russian Academy of Sciences), G.K. Skryabin Institute of Biochemistry and Physiology of Microorganisms, Russian Academy of Sciences, Pushchino 142290, Russia
3 shared publications A. S. Kharkova
Tula State University, Pr. Lenina 92, Tula, 300012 Russia
1 shared publication- Andrey Valerievich Machulin
Skryabin Institute of Biochemistry and Physiology of Microorganisms, Federal Research Center “Pushchino Scientific Center for Biological Research of Russian Academy of Science”, Russian Academy of Science, 142290 Pushchino, Russia
1 shared publication - Olga A. Kamanina
Tula State University, Tula, Russia
1 shared publication - Olga Nikolaevna Ponamoreva
Biotechnology Department, Tula State University, Pr. Lenina 92, 300012 Tula, Russia
1 shared publication
Latest Publications
- 29 June 2019
- Published by Springer Nature in 3 Biotech
- Vol. 9 (7) , 1-7
Glucose biosensor based on screen-printed electrode modified with silicone sol–gel conducting matrix containing carbon nanotubes
This research shows that high-performance biosensors can be produced by modification of screen-printed electrodes with enzymes and conducting hydrogel based on sol–gel matrix and single-walled carbon nanotubes. Tetraethoxysilane, dimethyldiethoxysilane and polyvinyl alcohol were used as the sol–gel matrix basis. Modified SWCNT provide direct electron transfer during glucose oxidation, as confirmed by cyclic voltammetry. The developed conducting sol–gel screen-printed electrodes can determine glucose within the concentration range 0.045–1.04 mM. The developed biosensor is not only in pace with its world analogues but even exceeds them by some analytical and metrological properties. The developed conducting sol–gel biosensor was used to measure the concentration of glucose in blood. The test results differed only insignificantly from those received with the help of standard glucose meter.
- 29 June 2019
- Published by Springer Nature in 3 Biotech
- Vol. 9 (7) , 1-7
Glucose biosensor based on screen-printed electrode modified with silicone sol–gel conducting matrix containing carbon nanotubes
This research shows that high-performance biosensors can be produced by modification of screen-printed electrodes with enzymes and conducting hydrogel based on sol–gel matrix and single-walled carbon nanotubes. Tetraethoxysilane, dimethyldiethoxysilane and polyvinyl alcohol were used as the sol–gel matrix basis. Modified SWCNT provide direct electron transfer during glucose oxidation, as confirmed by cyclic voltammetry. The developed conducting sol–gel screen-printed electrodes can determine glucose within the concentration range 0.045–1.04 mM. The developed biosensor is not only in pace with its world analogues but even exceeds them by some analytical and metrological properties. The developed conducting sol–gel biosensor was used to measure the concentration of glucose in blood. The test results differed only insignificantly from those received with the help of standard glucose meter.
- 1 March 2015
- Published by Pleiades Publishing Ltd in Russian Journal of Applied Chemistry
- Vol. 88 (3) , 463-472
Biosensors based on modified screen-printed enzyme electrodes for monitoring of fermentation processes
Biosensor array based on modified screen-printed electrodes containing enzymes (glucose oxidase, alcohol oxidase, lactate oxidase, mixture of glucose oxidase and γ-amylase) immobilized in a membrane of cross-linked bovine serum albumin was developed for the determination of the content of glucose, ethanol, lactic acid, and starch in fermentation media. The analytical and metrological characteristics of the developed biosensor system were determined. Samples of the fermentation mass and of alcoholic and fermented milk products were analyzed. Statistical analysis of the results obtained showed that the results of determining the content of glucose, ethanol, lactic acid, and starch with the developed biosensor system and by reference methods differed insignificantly. The developed biosensor system is considered as a base for fabricating a prototype of an analyzer for use in fermentation biotechnology.
- 1 March 2015
- Published by Pleiades Publishing Ltd in Russian Journal of Applied Chemistry
- Vol. 88 (3) , 463-472
Biosensors based on modified screen-printed enzyme electrodes for monitoring of fermentation processes
Biosensor array based on modified screen-printed electrodes containing enzymes (glucose oxidase, alcohol oxidase, lactate oxidase, mixture of glucose oxidase and γ-amylase) immobilized in a membrane of cross-linked bovine serum albumin was developed for the determination of the content of glucose, ethanol, lactic acid, and starch in fermentation media. The analytical and metrological characteristics of the developed biosensor system were determined. Samples of the fermentation mass and of alcoholic and fermented milk products were analyzed. Statistical analysis of the results obtained showed that the results of determining the content of glucose, ethanol, lactic acid, and starch with the developed biosensor system and by reference methods differed insignificantly. The developed biosensor system is considered as a base for fabricating a prototype of an analyzer for use in fermentation biotechnology.
- 4 November 2014
- Published by Pleiades Publishing Ltd in Applied Biochemistry and Microbiology
- Vol. 50 (9) , 835-841
Screen-printed electrodes modified with glucose oxidase immobilized in hybrid organosilicon sol-gel matrix
A new polymer composition was developed based on hybrid sol-gel material for the immobilization of enzymes on the surface of screen-printed carbon electrodes modified with Prussian blue. The existing and developed methods for the glucose oxidase (GO) immobilization are compared. Highly stable bioelectrodes were shown to be obtained by enzyme immobilization on a hybrid composition consisting of solgel/poly vinyl alcohol (PVA) (up to 60 sequential chains) and agar gel (up to 45 sequential chains). The range of glucose concentrations detected during enzyme immobilization in a hybrid sol-gel/PVA composition or agar gel without dilution of a sample was 1.0–5.9 μM and 3.6–6.3 μM, respectively. An analysis of wine products was conducted. The results obtained using the proposed biosensors were shown to differ insignificantly from those obtained by high-performance liquid chromatography (the correlation coefficient was 0.9998).
- 4 November 2014
- Published by Pleiades Publishing Ltd in Applied Biochemistry and Microbiology
- Vol. 50 (9) , 835-841
Screen-printed electrodes modified with glucose oxidase immobilized in hybrid organosilicon sol-gel matrix
A new polymer composition was developed based on hybrid sol-gel material for the immobilization of enzymes on the surface of screen-printed carbon electrodes modified with Prussian blue. The existing and developed methods for the glucose oxidase (GO) immobilization are compared. Highly stable bioelectrodes were shown to be obtained by enzyme immobilization on a hybrid composition consisting of solgel/poly vinyl alcohol (PVA) (up to 60 sequential chains) and agar gel (up to 45 sequential chains). The range of glucose concentrations detected during enzyme immobilization in a hybrid sol-gel/PVA composition or agar gel without dilution of a sample was 1.0–5.9 μM and 3.6–6.3 μM, respectively. An analysis of wine products was conducted. The results obtained using the proposed biosensors were shown to differ insignificantly from those obtained by high-performance liquid chromatography (the correlation coefficient was 0.9998).
- 1 April 2012
- Published by Elsevier in Enzyme and Microbial Technology
- Vol. 50 (4-5) , 215-220
Biosensor analyzer for BOD index express control on the basis of the yeast microorganisms Candida maltosa, Candida blankii, and Debaryomyces hansenii
- 1 April 2012
- Published by Elsevier in Enzyme and Microbial Technology
- Vol. 50 (4-5) , 215-220
Biosensor analyzer for BOD index express control on the basis of the yeast microorganisms Candida maltosa, Candida blankii, and Debaryomyces hansenii