Umme Kawsar Alam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Umme Kawsar Alam has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Mahdi Haghshenas-Jaryani
Department of Mechanical and Aerospace Engineering, New Mexico State University, Las Cruces, NM 88003, USA
2 shared publications - Kassidy Shedd
Department of Mechanical and Aerospace Engineering, New Mexico State University, Las Cruces, NM 88003, USA
1 shared publication
Latest Publications
- 22 April 2025
- Published by World Scientific Pub Co Pte Ltd in Journal of Medical Robotics Research
- Vol. 10 (01n02)
Modeling a Hybrid Soft-and-Rigid Robotic Exo-digit with Varying Length Soft Segments Coupled to a Human Finger
This paper presents the kinematics and quasi-static analytical model of a soft robotic exo-digit that physically interacts with a human finger model in the middle contact points along each link (in the [ ]-direction), which is crucial for rehabilitation. The hybrid soft-and-rigid exo-digit consists of three soft segments between four semi-rigid blocks, modeled as a lumped quasi-static model with constant curvatures and variable arc lengths. The material is modeled using Yeoh’s third-order hyperelastic model. The human finger is modeled as a rigid multi-body structure with torsional springs to represent joint stiffness. Kinematic and quasi-static models describe the interaction at multiple contact points between the soft robot and the human finger. Experimental studies on single soft segments and the full exo-digit interacting with the human finger validate the analytical model, showing improved accuracy with the variable arc length model over the constant-length model.
- 22 April 2025
- Published by World Scientific Pub Co Pte Ltd in Journal of Medical Robotics Research
- Vol. 10 (01n02)
Modeling a Hybrid Soft-and-Rigid Robotic Exo-digit with Varying Length Soft Segments Coupled to a Human Finger
This paper presents the kinematics and quasi-static analytical model of a soft robotic exo-digit that physically interacts with a human finger model in the middle contact points along each link (in the [ ]-direction), which is crucial for rehabilitation. The hybrid soft-and-rigid exo-digit consists of three soft segments between four semi-rigid blocks, modeled as a lumped quasi-static model with constant curvatures and variable arc lengths. The material is modeled using Yeoh’s third-order hyperelastic model. The human finger is modeled as a rigid multi-body structure with torsional springs to represent joint stiffness. Kinematic and quasi-static models describe the interaction at multiple contact points between the soft robot and the human finger. Experimental studies on single soft segments and the full exo-digit interacting with the human finger validate the analytical model, showing improved accuracy with the variable arc length model over the constant-length model.
- Open Access
- 31 May 2023
- Published by MDPI AG in Automation
- Vol. 4 (2) , 164-190
Trajectory Control in Discrete-Time Nonlinear Coupling Dynamics of a Soft Exo-Digit and a Human Finger Using Input–Output Feedback Linearization
This paper presents a quasi-static model-based control algorithm for controlling the motion of a soft robotic exo-digit with three independent actuation joints physically interacting with the human finger. A quasi-static analytical model of physical interaction between the soft exo-digit and a human finger model was developed. Then, the model was presented as a nonlinear discrete-time multiple-input multiple-output (MIMO) state-space representation for the control system design. Input–output feedback linearization was utilized and a control input was designed to linearize the input–output, where the input is the actuation pressure of an individual soft actuator, and the output is the pose of the human fingertip. The asymptotic stability of the nonlinear discrete-time system for trajectory tracking control is discussed. A soft robotic exoskeleton digit (exo-digit) and a 3D-printed human-finger model integrated with IMU sensors were used for the experimental test setup. An Arduino-based electro-pneumatic control hardware was developed to control the actuation pressure of the soft exo-digit. The effectiveness of the controller was examined through simulation studies and experimental testing for following different pose trajectories corresponding to the human finger pose during the activities of daily living. The model-based controller was able to follow the desired trajectories with a very low average root-mean-square error of 2.27 mm in the x-direction, 2.75 mm in the y-direction, and 3.90 degrees in the orientation of the human finger distal link about the z-axis.
- 31 May 2023
- Published by MDPI AG in Automation
- Vol. 4 (2) , 164-190
Open AccessTrajectory Control in Discrete-Time Nonlinear Coupling Dynamics of a Soft Exo-Digit and a Human Finger Using Input–Output Feedback Linearization
This paper presents a quasi-static model-based control algorithm for controlling the motion of a soft robotic exo-digit with three independent actuation joints physically interacting with the human finger. A quasi-static analytical model of physical interaction between the soft exo-digit and a human finger model was developed. Then, the model was presented as a nonlinear discrete-time multiple-input multiple-output (MIMO) state-space representation for the control system design. Input–output feedback linearization was utilized and a control input was designed to linearize the input–output, where the input is the actuation pressure of an individual soft actuator, and the output is the pose of the human fingertip. The asymptotic stability of the nonlinear discrete-time system for trajectory tracking control is discussed. A soft robotic exoskeleton digit (exo-digit) and a 3D-printed human-finger model integrated with IMU sensors were used for the experimental test setup. An Arduino-based electro-pneumatic control hardware was developed to control the actuation pressure of the soft exo-digit. The effectiveness of the controller was examined through simulation studies and experimental testing for following different pose trajectories corresponding to the human finger pose during the activities of daily living. The model-based controller was able to follow the desired trajectories with a very low average root-mean-square error of 2.27 mm in the x-direction, 2.75 mm in the y-direction, and 3.90 degrees in the orientation of the human finger distal link about the z-axis.