Shuzheng Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shuzheng Wang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Guyue Zhu
School of Electric Power Engineering (School of Shenguorong), Nanjing Institute of Technology, Nanjing 211167, China
2 shared publications - Haode Wu
School of Electric Power Engineering (School of Shenguorong), Nanjing Institute of Technology, Nanjing 211167, China
2 shared publications - Shengyuan Wang
School of Electric Power Engineering (School of Shenguorong), Nanjing Institute of Technology, Nanjing 211167, China
2 shared publications - Zhi Wu
Southeast University
2 shared publications - Haiming Zhu
School of Electrical Engineering, Nanjing Institute of Technology, Nanjing 211167, China
1 shared publication - Jiahao He
Electric Power Engineering, Nanjing Institute of Technology, Nanjing 211167, China
1 shared publication
Latest Publications
- Open Access
- 28 May 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (11) , 5447
Robust Data-Driven Transmission-Line Parameter Estimation for Reliable and Sustainable Smart Grid Operation
Accurate transmission-line parameters are essential for reliable, efficient, and sustainable smart grid operation, especially under increasing renewable-energy integration and data-driven grid management. However, line aging, temperature variations, and measurement outliers may cause significant deviations between actual and nominal grid models, thereby degrading the state estimation, power-flow analysis, and operational security assessment. To address these challenges, this paper proposes a robust transmission-line parameter estimation method based on a variable-projection framework. The proposed framework decomposes the original high-dimensional, strongly coupled, and non-convex joint estimation problem into two subproblems associated with line-parameter identification and operating-state calibration. An iteratively reweighted least-squares algorithm based on the Huber M-estimator is introduced to dynamically adjust measurement weights and suppress the influence of outliers. The preconditioned conjugate-gradient method is further employed to avoid the explicit inversion of large-scale normal matrices. Simulations on the IEEE 118-bus system demonstrate that the proposed method achieves a higher parameter-estimation accuracy and stronger robustness than conventional weighted least-squares and joint state-parameter estimation methods. In the base case, the proposed method reduces the RMSRE of line reactance to 0.0794%, compared with 0.1558% for WLS and 0.1126% for JSE. Under the representative 5% gross-error case, the proposed method maintains lower RMSREs of 0.9772%, 0.0875%, and 5.8536% for , , and , respectively. Further sensitivity tests under contamination ratios from 1% to 20%, outlier magnitude factors from 1.5 to 5.0, and different outlier-location patterns confirm that the proposed method maintains a more stable estimation accuracy than WLS, conventional JSE, and Huber-JSE without VPM under diverse bad-data conditions. In downstream operational evaluations, it reduces the branch active-power flow RMSE from 1.6842 MW to 0.7215 MW, voltage-magnitude RMSE from 0.00482 p.u. to 0.00216 p.u., and active-power-loss error from 2.4368% to 0.9327% compared with WLS. These quantitative results indicate that the proposed approach can improve the grid model accuracy under imperfect measurements, thereby supporting reliable and sustainable smart-grid operation.- 28 May 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (11) , 5447
Open AccessRobust Data-Driven Transmission-Line Parameter Estimation for Reliable and Sustainable Smart Grid Operation
Accurate transmission-line parameters are essential for reliable, efficient, and sustainable smart grid operation, especially under increasing renewable-energy integration and data-driven grid management. However, line aging, temperature variations, and measurement outliers may cause significant deviations between actual and nominal grid models, thereby degrading the state estimation, power-flow analysis, and operational security assessment. To address these challenges, this paper proposes a robust transmission-line parameter estimation method based on a variable-projection framework. The proposed framework decomposes the original high-dimensional, strongly coupled, and non-convex joint estimation problem into two subproblems associated with line-parameter identification and operating-state calibration. An iteratively reweighted least-squares algorithm based on the Huber M-estimator is introduced to dynamically adjust measurement weights and suppress the influence of outliers. The preconditioned conjugate-gradient method is further employed to avoid the explicit inversion of large-scale normal matrices. Simulations on the IEEE 118-bus system demonstrate that the proposed method achieves a higher parameter-estimation accuracy and stronger robustness than conventional weighted least-squares and joint state-parameter estimation methods. In the base case, the proposed method reduces the RMSRE of line reactance to 0.0794%, compared with 0.1558% for WLS and 0.1126% for JSE. Under the representative 5% gross-error case, the proposed method maintains lower RMSREs of 0.9772%, 0.0875%, and 5.8536% for , , and , respectively. Further sensitivity tests under contamination ratios from 1% to 20%, outlier magnitude factors from 1.5 to 5.0, and different outlier-location patterns confirm that the proposed method maintains a more stable estimation accuracy than WLS, conventional JSE, and Huber-JSE without VPM under diverse bad-data conditions. In downstream operational evaluations, it reduces the branch active-power flow RMSE from 1.6842 MW to 0.7215 MW, voltage-magnitude RMSE from 0.00482 p.u. to 0.00216 p.u., and active-power-loss error from 2.4368% to 0.9327% compared with WLS. These quantitative results indicate that the proposed approach can improve the grid model accuracy under imperfect measurements, thereby supporting reliable and sustainable smart-grid operation. - Open Access
- 21 April 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (8) , 4128
Risk-Aware Tie-Line Exchange Optimization for Probabilistic Production Simulation and Sustainable Renewable Energy Accommodation in Interconnected Power Systems
The transition toward sustainable and low-carbon power systems increasingly depends on the efficient accommodation of high shares of renewable energy while maintaining secure and reliable grid operation. In interconnected power systems, this challenge is intensified by strong cross-regional coupling, tie-line flow violation risks, and the high computational burden of fully coupled probabilistic assessments. To support the sustainable operation of renewable-rich interconnected systems, this paper proposes a probabilistic production simulation method that incorporates risk-aware tie-line exchange optimization. Sequential random sample paths are constructed by considering load fluctuations, renewable energy output uncertainty, and random outages of conventional units. Using cross-regional exchange power as coupling variables, a conditional value-at-risk (CVaR)-based pre-scheduling model is established to control tie-line and interface flow tail risks. Given the scheduled exchange power, cross-regional exchanges are transformed into regional boundary power injections, enabling decoupled sequential probabilistic production simulation for each region. The exchange schedule is then iteratively updated through marginal-value feedback. A four-region interconnected system is used for case-study validation. Results show that the proposed method improves renewable energy accommodation, reduces renewable curtailment, suppresses tie-line flow violation risk, and maintains high reliability assessment accuracy. Compared with the region-decoupled benchmark with fixed exchange power, the proposed method increases the renewable energy accommodation rate from 93.82% to 95.41% and reduces renewable curtailment from 312,162 MWh to 231,284 MWh, while also lowering expected energy not served and loss of load expectation. In addition, under the reported case-study setting, the proposed RC-IEF-PPS reduces the computation time from 5216.24 s for Full-PPS to 4074.63 s, i.e., by 21.9%, while maintaining comparable reliability assessment accuracy. These results indicate that the proposed framework can support the sustainable integration of high-penetration renewable energy by improving clean-energy utilization, operational reliability, and computational tractability in interconnected power systems.
- 21 April 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (8) , 4128
Open AccessRisk-Aware Tie-Line Exchange Optimization for Probabilistic Production Simulation and Sustainable Renewable Energy Accommodation in Interconnected Power Systems
The transition toward sustainable and low-carbon power systems increasingly depends on the efficient accommodation of high shares of renewable energy while maintaining secure and reliable grid operation. In interconnected power systems, this challenge is intensified by strong cross-regional coupling, tie-line flow violation risks, and the high computational burden of fully coupled probabilistic assessments. To support the sustainable operation of renewable-rich interconnected systems, this paper proposes a probabilistic production simulation method that incorporates risk-aware tie-line exchange optimization. Sequential random sample paths are constructed by considering load fluctuations, renewable energy output uncertainty, and random outages of conventional units. Using cross-regional exchange power as coupling variables, a conditional value-at-risk (CVaR)-based pre-scheduling model is established to control tie-line and interface flow tail risks. Given the scheduled exchange power, cross-regional exchanges are transformed into regional boundary power injections, enabling decoupled sequential probabilistic production simulation for each region. The exchange schedule is then iteratively updated through marginal-value feedback. A four-region interconnected system is used for case-study validation. Results show that the proposed method improves renewable energy accommodation, reduces renewable curtailment, suppresses tie-line flow violation risk, and maintains high reliability assessment accuracy. Compared with the region-decoupled benchmark with fixed exchange power, the proposed method increases the renewable energy accommodation rate from 93.82% to 95.41% and reduces renewable curtailment from 312,162 MWh to 231,284 MWh, while also lowering expected energy not served and loss of load expectation. In addition, under the reported case-study setting, the proposed RC-IEF-PPS reduces the computation time from 5216.24 s for Full-PPS to 4074.63 s, i.e., by 21.9%, while maintaining comparable reliability assessment accuracy. These results indicate that the proposed framework can support the sustainable integration of high-penetration renewable energy by improving clean-energy utilization, operational reliability, and computational tractability in interconnected power systems.
- Open Access
Fault Diagnosis Method for Converter Stations Based on Fault Area Identification and Evidence Information Fusion
DC converter stations have a high voltage level, a long transmission distance, and complex internal equipment, and contain power electronic devices, which seriously endanger the stable operation of the system itself and the active distribution network at the receiving end when faults occur. Accurate fault analysis and diagnosis are critical to the safe and stable operation of power systems. Traditional fault diagnosis methods often rely on a single source of information, leading to issues such as insufficient information utilization and incomplete diagnostic scope when applied to DC transmission systems. To address these problems, a fault diagnosis method for converter stations based on preliminary identification of the fault range and the fusion of evidence information of the switch signal and electrical quantity is proposed. First, the preprocessing of converter station sequential event recording (SER) events and a statistical analysis of event characteristics are completed to initially determine the range of the fault.Then, a fuzzy Petri net model and a BP neural network model are constructed on the basis of the fault data from a real-time digital simulation system (RTDS), and the corresponding evidence information of the switch signal and electrical quantity are obtained via iterative inference and deep learning methods. Finally, on the basis of D-S evidence theory, a comprehensive diagnosis result is obtained by fusing the switch and electric evidence information. Taking the fault data of a DC converter station as an example, the proposed method is analyzed and compared with the traditional method, which is based on single information. The results show that the proposed method can reliably and accurately identify fault points in the protected area of the converter station.
Open AccessFault Diagnosis Method for Converter Stations Based on Fault Area Identification and Evidence Information Fusion
DC converter stations have a high voltage level, a long transmission distance, and complex internal equipment, and contain power electronic devices, which seriously endanger the stable operation of the system itself and the active distribution network at the receiving end when faults occur. Accurate fault analysis and diagnosis are critical to the safe and stable operation of power systems. Traditional fault diagnosis methods often rely on a single source of information, leading to issues such as insufficient information utilization and incomplete diagnostic scope when applied to DC transmission systems. To address these problems, a fault diagnosis method for converter stations based on preliminary identification of the fault range and the fusion of evidence information of the switch signal and electrical quantity is proposed. First, the preprocessing of converter station sequential event recording (SER) events and a statistical analysis of event characteristics are completed to initially determine the range of the fault.Then, a fuzzy Petri net model and a BP neural network model are constructed on the basis of the fault data from a real-time digital simulation system (RTDS), and the corresponding evidence information of the switch signal and electrical quantity are obtained via iterative inference and deep learning methods. Finally, on the basis of D-S evidence theory, a comprehensive diagnosis result is obtained by fusing the switch and electric evidence information. Taking the fault data of a DC converter station as an example, the proposed method is analyzed and compared with the traditional method, which is based on single information. The results show that the proposed method can reliably and accurately identify fault points in the protected area of the converter station.
- Open Access
- 1 June 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (11) , 8929
Two-Stage Grid-Connected Frequency Regulation Control Strategy Based on Photovoltaic Power Prediction
The large number of photovoltaics connected to the distribution network via power electronic converters squeezes the functional space of traditional synchronous generators in the power system and reduces the inertia of the network itself. However, due to the random and fluctuating nature of PV power generation, different types of meteorological conditions can also affect the inertia support capability of PV output power. Therefore, this paper proposes a frequency regulation control strategy based on the dynamic characteristics of the grid-side DC capacitor. Firstly, the control strategy of the grid-side inverter is improved and the mechanism of the frequency dynamic response model under PV penetration is analysed. Secondly, data from different weather types are correlated and analysed to predict PV power, and wireless sensor technology is used to introduce the data signals into the control link. Finally, a simulation model of a two-stage PV power generation system is developed and the fast-response capability of the system under different control parameters when the load is increased or decreased is analysed. The results show that under the proposed frequency regulation strategy, the larger the regulation coefficient and virtual inertia time constant, the greater the virtual inertia provided by the PV power generation, which improves the stability of the distribution network.
- 1 June 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (11) , 8929
Open AccessTwo-Stage Grid-Connected Frequency Regulation Control Strategy Based on Photovoltaic Power Prediction
The large number of photovoltaics connected to the distribution network via power electronic converters squeezes the functional space of traditional synchronous generators in the power system and reduces the inertia of the network itself. However, due to the random and fluctuating nature of PV power generation, different types of meteorological conditions can also affect the inertia support capability of PV output power. Therefore, this paper proposes a frequency regulation control strategy based on the dynamic characteristics of the grid-side DC capacitor. Firstly, the control strategy of the grid-side inverter is improved and the mechanism of the frequency dynamic response model under PV penetration is analysed. Secondly, data from different weather types are correlated and analysed to predict PV power, and wireless sensor technology is used to introduce the data signals into the control link. Finally, a simulation model of a two-stage PV power generation system is developed and the fast-response capability of the system under different control parameters when the load is increased or decreased is analysed. The results show that under the proposed frequency regulation strategy, the larger the regulation coefficient and virtual inertia time constant, the greater the virtual inertia provided by the PV power generation, which improves the stability of the distribution network.