Mónica Canabal-Carbia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mónica Canabal-Carbia has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
- Irene Estévez
Grup d’Optica, Departament de Fisica, Universitat Autonoma de Barcelona, 08193 Bellaterra, Spain
7 shared publications Juan Campos
6 shared publicationsAngel Lizana
5 shared publicationsEmilio González-Arnay
5 shared publications- Angel Lizana
Universitat Autónoma de Barcelona
4 shared publications - Ignacio Moreno
Instituto de Bioingeniería, Universidad Miguel Hernández de Elche, Avda. Universidad s/n, 03202 Elche, Spain
3 shared publications
Latest Publications
- 12 February 2026
- Published by Springer Nature
- p. 59-62
Polarimetric Methods for the Characterization of Biological Samples
- 12 February 2026
- Published by Springer Nature
- p. 59-62
Polarimetric Methods for the Characterization of Biological Samples
- Open Access
- 19 September 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (18) , 10205
IPP and PRT Depolarizing Spaces for the Study of Depolarizing Samples: A Review
Depolarizing spaces can reveal and emphasize depolarization origins in samples, making them suitable tools for target detection and disease diagnosis. The Indices of Polarization Purity (IPP) space, considered a representative depolarizing space, highlights the depolarization characteristics of samples, and has demonstrated its superiority in analyzing and identifying depolarization samples, i.e., biological tissues and scattering environments. Recently, a new polarization representation, the so-called Polarizance–Reflection–Transformation (PRT) space has been proposed, which has been employed to distinguish between non-depolarization systems, as well as analyze anisotropic depolarizers. Importantly, the IPP and PRT spaces provide complementary information of samples, hence presenting more polarimetric characterizations of the samples of interest. In consideration of the high importance of the IPP and PRT spaces in this topic, in this paper, we review the methodology of these two spaces and their applications in depolarizer distinction.
- 19 September 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (18) , 10205
Open AccessIPP and PRT Depolarizing Spaces for the Study of Depolarizing Samples: A Review
Depolarizing spaces can reveal and emphasize depolarization origins in samples, making them suitable tools for target detection and disease diagnosis. The Indices of Polarization Purity (IPP) space, considered a representative depolarizing space, highlights the depolarization characteristics of samples, and has demonstrated its superiority in analyzing and identifying depolarization samples, i.e., biological tissues and scattering environments. Recently, a new polarization representation, the so-called Polarizance–Reflection–Transformation (PRT) space has been proposed, which has been employed to distinguish between non-depolarization systems, as well as analyze anisotropic depolarizers. Importantly, the IPP and PRT spaces provide complementary information of samples, hence presenting more polarimetric characterizations of the samples of interest. In consideration of the high importance of the IPP and PRT spaces in this topic, in this paper, we review the methodology of these two spaces and their applications in depolarizer distinction.
- Open Access
- 23 April 2025
- Published by Elsevier in Optics & Laser Technology
- Vol. 188
Revealing hidden bioimaging information by isotropic depolarization filtering
- 23 April 2025
- Published by Elsevier in Optics & Laser Technology
- Vol. 188
Open AccessRevealing hidden bioimaging information by isotropic depolarization filtering
- Open Access
Revealing hidden bioimaging information by isotropic depolarization filtering
We propose an imaging method to enhance and reveal structures within samples by using a polarization-based filter. This filter removes the isotropic content while amplifying the anisotropic component of depolarization. Whereas isotropic depolarization leads to a complete loss of polarimetric information, the anisotropic one is connected with intrinsic characteristics of samples. The filter has the capability to diminish the isotropic depolarization of samples, revealing their inherent information. As representative cases, we analyze the effect of the filter in heart and brain sections of animal origin. Results highlight the outstanding performance of the filter. In heart, myocardial and subendocardial structures are better visualized, whereas in the brain, fiber tracts are identified. These proves the significance of this filter in the medical field, paving the way to the early detection of pathologies. The methodologies here presented could be applied in a wide range of applications, providing a significant advance in polarization imaging where high isotropic depolarization response is present, this being a common scenario in nature.
Open AccessRevealing hidden bioimaging information by isotropic depolarization filtering
We propose an imaging method to enhance and reveal structures within samples by using a polarization-based filter. This filter removes the isotropic content while amplifying the anisotropic component of depolarization. Whereas isotropic depolarization leads to a complete loss of polarimetric information, the anisotropic one is connected with intrinsic characteristics of samples. The filter has the capability to diminish the isotropic depolarization of samples, revealing their inherent information. As representative cases, we analyze the effect of the filter in heart and brain sections of animal origin. Results highlight the outstanding performance of the filter. In heart, myocardial and subendocardial structures are better visualized, whereas in the brain, fiber tracts are identified. These proves the significance of this filter in the medical field, paving the way to the early detection of pathologies. The methodologies here presented could be applied in a wide range of applications, providing a significant advance in polarization imaging where high isotropic depolarization response is present, this being a common scenario in nature.
- Open Access
- 18 October 2023
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 287, 03004
Inspection of plant pathologies through pseudocolored images based on polarimetric basis
The study of the interaction of biological tissue with polarized light leads to relevant information of physical properties (dichroism, retardance and depolarization) of samples. Polarimetric analysis of different characteristics in tissues is useful for applications such us tissue classification, contrast enhancement or pathology detection. By means of polarimetric imaging techniques we can characterize the polarimetric signature of biological samples in a noninvasive and nondestructive way. We have found that depolarization information is of special interest in turbid media such as plant tissue. In this manuscript we use polarimetric observables for plant inspection. In particular, we provide enhanced visualization of certain plant pathologies by constructing depolarization based pseudocolored images of pathological leaves where the pathological areas are revealed.
- 18 October 2023
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 287, 03004
Open AccessInspection of plant pathologies through pseudocolored images based on polarimetric basis
The study of the interaction of biological tissue with polarized light leads to relevant information of physical properties (dichroism, retardance and depolarization) of samples. Polarimetric analysis of different characteristics in tissues is useful for applications such us tissue classification, contrast enhancement or pathology detection. By means of polarimetric imaging techniques we can characterize the polarimetric signature of biological samples in a noninvasive and nondestructive way. We have found that depolarization information is of special interest in turbid media such as plant tissue. In this manuscript we use polarimetric observables for plant inspection. In particular, we provide enhanced visualization of certain plant pathologies by constructing depolarization based pseudocolored images of pathological leaves where the pathological areas are revealed.
- Open Access
- 20 September 2023
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 172
Connecting the microscopic depolarizing origin of samples with macroscopic measures of the Indices of Polarimetric Purity
- 20 September 2023
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 172
Open AccessConnecting the microscopic depolarizing origin of samples with macroscopic measures of the Indices of Polarimetric Purity
- Open Access
Polarimetric Images of Biological Tissues Based on the Arrow Decomposition of Mueller Matrices
Polarimetric techniques are widely used in a vast number of applications such as remote sensing, material characterization, astronomy and biological tissue inspection. In this last scenario, different polarimetric observables have proved their potential for enhancing imaging visualization. In this work we use a set of polarimetric observables derived from the arrow decomposition of the Mueller matrix for the first time: enpolarizing, retarding and depolarizing descriptors. In particular, the mean intensity coefficient and the three indices of polarimetric purity, the absolute values and Poincaré orientations of diattenuation, polarizance, entrance retardance and exit retardance vectors are considered. Results show images with enhanced visualization or even revealing invisible structures when compared to standard intensity images. In particular, thanks to these metrics, we improve the visualization of the necrotic areas of a Vitis rupestris leaf. In the case of animal samples, boundaries between different fascicles inside a tendon of an ex vivo chicken sample are revealed, as is the directionality of fiber tracts of the subcortical white matter in an ex vivo cow brain. The experimental results show the potential for biophotonics imaging and how polarimetric techniques could be useful for biomedical and botanical applications.
Open AccessPolarimetric Images of Biological Tissues Based on the Arrow Decomposition of Mueller Matrices
Polarimetric techniques are widely used in a vast number of applications such as remote sensing, material characterization, astronomy and biological tissue inspection. In this last scenario, different polarimetric observables have proved their potential for enhancing imaging visualization. In this work we use a set of polarimetric observables derived from the arrow decomposition of the Mueller matrix for the first time: enpolarizing, retarding and depolarizing descriptors. In particular, the mean intensity coefficient and the three indices of polarimetric purity, the absolute values and Poincaré orientations of diattenuation, polarizance, entrance retardance and exit retardance vectors are considered. Results show images with enhanced visualization or even revealing invisible structures when compared to standard intensity images. In particular, thanks to these metrics, we improve the visualization of the necrotic areas of a Vitis rupestris leaf. In the case of animal samples, boundaries between different fascicles inside a tendon of an ex vivo chicken sample are revealed, as is the directionality of fiber tracts of the subcortical white matter in an ex vivo cow brain. The experimental results show the potential for biophotonics imaging and how polarimetric techniques could be useful for biomedical and botanical applications.
- Open Access
- 4 May 2023
- Published by MDPI AG in Preprints.org
Polarimetric Images of Biological Tissues Based on the Arrow Decomposition of Mueller Matrices
Through the arrow decomposition of the Mueller matrix, respective sets of sixteen independent polarimetric images of biological tissues are obtained for enpolarizing, retarding and depolariz-ing descriptors. In addition to the mean intensity coefficient and the three indices of polarimetric purity, the absolute values and Poincaré orientations of diattenuation, polarizance, entrance re-tardance and exit retardance vectors are considered. In this work we use for the first time this set of polarimetric observables for the visualization of biological structures, both of animal and vege-tal origin. Results show images with enhanced visualization derived from the spatial variation of such significant polarimetric properties. The experimental results are discussed, showing the suit-ability of such set of observables for applications in biophotonics imaging, providing not only ex-cellent visualization of biological tissues, but also showing structures not visible in non-polarimetric images.
- 4 May 2023
- Published by MDPI AG in Preprints.org
Open AccessPolarimetric Images of Biological Tissues Based on the Arrow Decomposition of Mueller Matrices
Through the arrow decomposition of the Mueller matrix, respective sets of sixteen independent polarimetric images of biological tissues are obtained for enpolarizing, retarding and depolariz-ing descriptors. In addition to the mean intensity coefficient and the three indices of polarimetric purity, the absolute values and Poincaré orientations of diattenuation, polarizance, entrance re-tardance and exit retardance vectors are considered. In this work we use for the first time this set of polarimetric observables for the visualization of biological structures, both of animal and vege-tal origin. Results show images with enhanced visualization derived from the spatial variation of such significant polarimetric properties. The experimental results are discussed, showing the suit-ability of such set of observables for applications in biophotonics imaging, providing not only ex-cellent visualization of biological tissues, but also showing structures not visible in non-polarimetric images.
- 15 March 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12382, 16-46
Enhancing biological tissue structures visualization through polarimetric parameters
Polarimetrical imaging is a noninvasive optical technique of great interest in biophotonics since it has the capability of obtaining relevant information of biological samples, being useful, for instance, for the early detection of diseases or the classification of biological structures, both on animal and vegetal tissues. Different structures produce different outcomes when interacting with light due to their polarimetric properties such as depolarization, dichroism or retardance. An exhaustive polarimetric analysis of these characteristics can unveil the relation between the tissue inherent characteristics and its polarimetric response, enabling us to find the most appropriate polarimetric parameters to describe or study a sample. These polarimetric characteristics can be obtained through the experimental measurement of the Mueller matrix (M) of a sample, from which a range of different polarimetric observables, giving physical interpretation, can be deduced. By taking advantage of these parameters, we propose a study of the suitability of different groups of metrics for the contrast enhancement in biological tissues imaging, taking special attention on some depolarization metrics and some physical parameters such as the wavelength or the angle of incidence of the illumination light. The results obtained suggest the convenience of certain parameters which may be of interest in multiple biomedical scenarios such as pathology early detection or enhanced visualization of different structures for clinical applications.
- 15 March 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12382, 16-46
Enhancing biological tissue structures visualization through polarimetric parameters
Polarimetrical imaging is a noninvasive optical technique of great interest in biophotonics since it has the capability of obtaining relevant information of biological samples, being useful, for instance, for the early detection of diseases or the classification of biological structures, both on animal and vegetal tissues. Different structures produce different outcomes when interacting with light due to their polarimetric properties such as depolarization, dichroism or retardance. An exhaustive polarimetric analysis of these characteristics can unveil the relation between the tissue inherent characteristics and its polarimetric response, enabling us to find the most appropriate polarimetric parameters to describe or study a sample. These polarimetric characteristics can be obtained through the experimental measurement of the Mueller matrix (M) of a sample, from which a range of different polarimetric observables, giving physical interpretation, can be deduced. By taking advantage of these parameters, we propose a study of the suitability of different groups of metrics for the contrast enhancement in biological tissues imaging, taking special attention on some depolarization metrics and some physical parameters such as the wavelength or the angle of incidence of the illumination light. The results obtained suggest the convenience of certain parameters which may be of interest in multiple biomedical scenarios such as pathology early detection or enhanced visualization of different structures for clinical applications.
- Open Access
- 23 February 2023
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
- Vol. 16 (05)
Depolarizing metrics in the biomedical field: Vision enhancement and classification of biological tissues
Polarimetry encompasses a collection of optical techniques broadly used in a variety of fields. Nowadays, such techniques have provided their suitability in the biomedical field through the study of the polarimetric response of biological samples (retardance, dichroism and depolarization) by measuring certain polarimetric observables. One of these features, depolarization, is mainly produced by scattering on samples, which is a predominant effect in turbid media as biological tissues. In turn, retardance and dichroic effects are produced by tissue anisotropies and can lead to depolarization too. Since depolarization is a predominant effect in tissue samples, we focus on studying different depolarization metrics for biomedical applications. We report the suitability of a set of depolarizing observables, the indices of polarimetric purity (IPPs), for biological tissue inspection. We review some results where we demonstrate that IPPs lead to better performance than the depolarization index, which is a well-established and commonly used depolarization observable in the literature. We also provide how IPPs are able to significantly enhance contrast between different tissue structures and even to reveal structures hidden by using standard intensity images. Finally, we also explore the classificatory potential of IPPs and other depolarizing observables for the discrimination of different tissues obtained from ex vivo chicken samples (muscle, tendon, myotendinous junction and bone), reaching accurate models for tissue classification.
- 23 February 2023
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
- Vol. 16 (05)
Open AccessDepolarizing metrics in the biomedical field: Vision enhancement and classification of biological tissues
Polarimetry encompasses a collection of optical techniques broadly used in a variety of fields. Nowadays, such techniques have provided their suitability in the biomedical field through the study of the polarimetric response of biological samples (retardance, dichroism and depolarization) by measuring certain polarimetric observables. One of these features, depolarization, is mainly produced by scattering on samples, which is a predominant effect in turbid media as biological tissues. In turn, retardance and dichroic effects are produced by tissue anisotropies and can lead to depolarization too. Since depolarization is a predominant effect in tissue samples, we focus on studying different depolarization metrics for biomedical applications. We report the suitability of a set of depolarizing observables, the indices of polarimetric purity (IPPs), for biological tissue inspection. We review some results where we demonstrate that IPPs lead to better performance than the depolarization index, which is a well-established and commonly used depolarization observable in the literature. We also provide how IPPs are able to significantly enhance contrast between different tissue structures and even to reveal structures hidden by using standard intensity images. Finally, we also explore the classificatory potential of IPPs and other depolarizing observables for the discrimination of different tissues obtained from ex vivo chicken samples (muscle, tendon, myotendinous junction and bone), reaching accurate models for tissue classification.