Monish S. Lavu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Monish S. Lavu has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
- Atul F. Kamath
Case Western Reserve University School of Medicine, Cleveland, OH, 44106, USA
14 shared publications - Christian J. Hecht
Case Western Reserve University School of Medicine, Cleveland, USA
7 shared publications - Joshua R. Porto
Case Western Reserve University School of Medicine, Cleveland, OH, 44106, USA
7 shared publications David C. Kaelber
Departments of Internal Medicine, Pediatrics, and Population and Quantitative Health Sciences, Case Western Reserve University, Cleveland, OH
6 shared publications- Alexander J. Acuna
Department of Orthopaedics, Rush University Medical Center, Chicago, Illinois
4 shared publications Christian J. Hecht
Department of Orthopaedics, Case Western Reserve University School of Medicine, Cleveland, Ohio
4 shared publications
Latest Publications
- 7 September 2026
- Published by Elsevier in The Spine Journal
Impact of GLP-1 dose intensity on perioperative and long-term fusion outcomes following ACDF
- 7 September 2026
- Published by Elsevier in The Spine Journal
Impact of GLP-1 dose intensity on perioperative and long-term fusion outcomes following ACDF
- Open Access
- 6 August 2026
- Published by Charter Services New York d/b/a Journal of Orthopaedic Experience and Innovation in Journal of Orthopaedic Experience & Innovation
- Vol. 7 (2)
Trends in Orthopedic Surgeons Signing Medicare Opt-Out Affidavits
Introduction: Medicare reimbursement cuts and increasing administrative burdens have contributed to a growing number of physicians opting out of the program, with orthopedic surgeons disproportionately affected due to their patient population, procedural volume, and operational costs. Therefore, this study aimed to analyze (1) trends in the incidence of orthopedic surgeons opting out of Medicare, (2) the demographic and professional characteristics of those opting out, (3) the geographic distribution of opt-outs, and (4) provider characteristics associated with the timing of opt-outs among orthopedic surgeons. Methods: This cross-sectional study analyzed historical data reported from the CMS Opt-Out Affidavit and the AAOS census databases. By matching National Provider Identifier, additional data on surgeon demographics, career stage, subspecialty, and practice type were extracted from publicly available professional profiles to assess factors influencing opt-out. Results: The incidence of Medicare opt-outs among orthopedic surgeons has risen steadily over the past two decades, totaling n=311 (R^2 = 0.64, p < 0.001). Opt-outs were highest among surgeons having more than 30 years of experience (49.5%, 95% CI: 43.8-55.2%). Highest opt-out rates were observed in New York (5.51%) and New Jersey (4.12%) when adjusted by the orthopedic surgeon population. For a given surgeon, the strongest predictors of earlier Medicare opt-out year included the years of practice (-0.14, 95% CI: -0.18 to -0.10) and practice type, with group practice surgeons opting out earlier (-1.93, 95% CI: -3.12 to -0.74). Conclusions: Medicare opt-out among orthopedic surgeons remains a rare event, reflecting the structural necessity of Medicare participation in a specialty heavily reliant on an elderly patient population. While opt-outs have increased slightly over time, they are primarily observed among late-career or transitioning surgeons, suggesting that most practicing orthopedic surgeons are functionally unable to disengage from Medicare. These findings highlight the enduring dependence of orthopedic surgery on Medicare and underscore the importance of policy reforms aimed at improving the program rather than expecting large-scale provider exit.
- 6 August 2026
- Published by Charter Services New York d/b/a Journal of Orthopaedic Experience and Innovation in Journal of Orthopaedic Experience & Innovation
- Vol. 7 (2)
Open AccessTrends in Orthopedic Surgeons Signing Medicare Opt-Out Affidavits
Introduction: Medicare reimbursement cuts and increasing administrative burdens have contributed to a growing number of physicians opting out of the program, with orthopedic surgeons disproportionately affected due to their patient population, procedural volume, and operational costs. Therefore, this study aimed to analyze (1) trends in the incidence of orthopedic surgeons opting out of Medicare, (2) the demographic and professional characteristics of those opting out, (3) the geographic distribution of opt-outs, and (4) provider characteristics associated with the timing of opt-outs among orthopedic surgeons. Methods: This cross-sectional study analyzed historical data reported from the CMS Opt-Out Affidavit and the AAOS census databases. By matching National Provider Identifier, additional data on surgeon demographics, career stage, subspecialty, and practice type were extracted from publicly available professional profiles to assess factors influencing opt-out. Results: The incidence of Medicare opt-outs among orthopedic surgeons has risen steadily over the past two decades, totaling n=311 (R^2 = 0.64, p < 0.001). Opt-outs were highest among surgeons having more than 30 years of experience (49.5%, 95% CI: 43.8-55.2%). Highest opt-out rates were observed in New York (5.51%) and New Jersey (4.12%) when adjusted by the orthopedic surgeon population. For a given surgeon, the strongest predictors of earlier Medicare opt-out year included the years of practice (-0.14, 95% CI: -0.18 to -0.10) and practice type, with group practice surgeons opting out earlier (-1.93, 95% CI: -3.12 to -0.74). Conclusions: Medicare opt-out among orthopedic surgeons remains a rare event, reflecting the structural necessity of Medicare participation in a specialty heavily reliant on an elderly patient population. While opt-outs have increased slightly over time, they are primarily observed among late-career or transitioning surgeons, suggesting that most practicing orthopedic surgeons are functionally unable to disengage from Medicare. These findings highlight the enduring dependence of orthopedic surgery on Medicare and underscore the importance of policy reforms aimed at improving the program rather than expecting large-scale provider exit.
- Open Access
- 16 May 2026
- Published by Elsevier in Journal of Orthopaedics
- Vol. 77, 106-115
Perioperative hyponatremia in total joint arthroplasty: A systematic review of prevalence, risk factors, outcomes, and management
- 16 May 2026
- Published by Elsevier in Journal of Orthopaedics
- Vol. 77, 106-115
Open AccessPerioperative hyponatremia in total joint arthroplasty: A systematic review of prevalence, risk factors, outcomes, and management
- 27 October 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
Tranexamic acid lowers transfusions and readmissions in high‐risk total knee arthroplasty patients, but neurologic risks remain in patients with seizures or visual disturbances
Purpose: Tranexamic acid (TXA) is widely used in total knee arthroplasty (TKA) to reduce perioperative blood loss and transfusions. However, its safety in high‐risk patients remains uncertain. This study evaluates TXA's safety and efficacy in TKA patients with a history of (1) thromboembolic events, (2) renal failure, (3) atrial fibrillation, (4) seizures and (5) visual disturbances. Methods: A retrospective analysis of the US Collaborative Network within TriNetX examined TKA patients from 2017 to 2023 ( n = 59,057). High‐risk patients were categorised by preexisting risk factors and propensity‐score matched into TXA and non‐TXA groups. Postoperative outcomes, including thromboembolic events, transfusions, renal failure, seizures, visual disturbances, infections, revisions, readmissions and mortality, were compared using odds ratios (OR) with 95% confidence intervals (CIs). Results: TXA was associated with lower transfusion rates, revisions, readmissions and emergency visits across multiple risk groups. No increased risk of deep vein thrombosis (DVT) or (PE) was observed in patients with prior thrombosis, renal failure, or atrial fibrillation, though ischaemic stroke/transient ischaemic attack (TIA) was higher in those with prior thrombosis (5.6% vs. 3.9%, OR: 1.44, 95% CI: 1.24–1.68). Patients with seizures had higher rates of postoperative seizures (10.4% vs. 7.1%, OR: 1.53, 95% CI: 1.18–1.99) and pulmonary embolism (1.9% vs. 1.0%, OR: 2.02, 95% CI: 1.06–3.85). In those with visual disturbances, TXA was linked to increased postoperative seizures (0.9% vs. 0.4%, OR: 1.97, 95% CI: 1.21–3.19) and visual disturbances (4.2% vs. 3.3%, OR: 1.29, 95% CI: 1.07–1.57). Conclusions: TXA reduced transfusions, readmissions and revisions in high‐risk TKA patients without increasing DVT or PE risk, though there was a modest increase in stroke/TIA for patients with prior thromboembolism. However, higher postoperative neurologic complications in patients with seizures or visual disturbances warrant further investigation. While TXA can provide benefits across several outcomes, discretion is advised in patients with neurological risk factors to optimise safety. Level of Evidence: Level III, retrospective cohort study.
- 27 October 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
Tranexamic acid lowers transfusions and readmissions in high‐risk total knee arthroplasty patients, but neurologic risks remain in patients with seizures or visual disturbances
Purpose: Tranexamic acid (TXA) is widely used in total knee arthroplasty (TKA) to reduce perioperative blood loss and transfusions. However, its safety in high‐risk patients remains uncertain. This study evaluates TXA's safety and efficacy in TKA patients with a history of (1) thromboembolic events, (2) renal failure, (3) atrial fibrillation, (4) seizures and (5) visual disturbances. Methods: A retrospective analysis of the US Collaborative Network within TriNetX examined TKA patients from 2017 to 2023 ( n = 59,057). High‐risk patients were categorised by preexisting risk factors and propensity‐score matched into TXA and non‐TXA groups. Postoperative outcomes, including thromboembolic events, transfusions, renal failure, seizures, visual disturbances, infections, revisions, readmissions and mortality, were compared using odds ratios (OR) with 95% confidence intervals (CIs). Results: TXA was associated with lower transfusion rates, revisions, readmissions and emergency visits across multiple risk groups. No increased risk of deep vein thrombosis (DVT) or (PE) was observed in patients with prior thrombosis, renal failure, or atrial fibrillation, though ischaemic stroke/transient ischaemic attack (TIA) was higher in those with prior thrombosis (5.6% vs. 3.9%, OR: 1.44, 95% CI: 1.24–1.68). Patients with seizures had higher rates of postoperative seizures (10.4% vs. 7.1%, OR: 1.53, 95% CI: 1.18–1.99) and pulmonary embolism (1.9% vs. 1.0%, OR: 2.02, 95% CI: 1.06–3.85). In those with visual disturbances, TXA was linked to increased postoperative seizures (0.9% vs. 0.4%, OR: 1.97, 95% CI: 1.21–3.19) and visual disturbances (4.2% vs. 3.3%, OR: 1.29, 95% CI: 1.07–1.57). Conclusions: TXA reduced transfusions, readmissions and revisions in high‐risk TKA patients without increasing DVT or PE risk, though there was a modest increase in stroke/TIA for patients with prior thromboembolism. However, higher postoperative neurologic complications in patients with seizures or visual disturbances warrant further investigation. While TXA can provide benefits across several outcomes, discretion is advised in patients with neurological risk factors to optimise safety. Level of Evidence: Level III, retrospective cohort study.
- Open Access
- 1 August 2025
- Published by Wolters Kluwer Health in JAAOS: Global Research and Reviews
- Vol. 9 (8)
An Assessment of the Journal of Bone and Joint Surgery Publication Trends From 2012 Through 2022
Background: Clinical research is an integral component of orthopaedic practice with the purpose of advancing the field and improving patient care. The Journal of Bone and Joint Surgery (JBJS) is a well-respected journal with a high impact factor and considerable influence on clinical practice. To our knowledge, there has been no systematic evaluation highlighting the variety of research published in this journal. Therefore, the purpose of this study was to evaluate trends in characteristics of articles published in JBJS from 2012 to 2022, including type of study, level of evidence, author information, and country of publication. Methods: Articles published in JBJS between 2012 and 2022 were retrieved from the JBJS Archives. Title, level of evidence, description of the study as delineated in the abstract, first author degree, number of authors, and country of publication were recorded for each published article. Results: A total of 2668 articles were published in JBJS from 2012 to 2022. The proportion of preclinical studies published per year significantly decreased (P = 0.0025), whereas no statistically significant change was observed in the proportion of clinical studies (P = 0.34). A significant increase was noted in the proportion of database studies published (P = 0.00012). Studies classified as level II decreased over the study period (P = 0.029), whereas level III increased over the study period (P = 0.034). The average number of authors per article was 6 ± 3 authors with a significantly increasing trend over the study period (P = 0.0043). The proportion of first authors who were MD or equivalent decreased (P = 0.025), whereas first authors who were non-MD or non-PhD equivalent increased (P = 0.0068). Conclusion: The publication trends in JBJS over the past decade demonstrate the changing landscape of orthopaedic research as it aims to address the burden of musculoskeletal injury and disease.
- 1 August 2025
- Published by Wolters Kluwer Health in JAAOS: Global Research and Reviews
- Vol. 9 (8)
Open AccessAn Assessment of the Journal of Bone and Joint Surgery Publication Trends From 2012 Through 2022
Background: Clinical research is an integral component of orthopaedic practice with the purpose of advancing the field and improving patient care. The Journal of Bone and Joint Surgery (JBJS) is a well-respected journal with a high impact factor and considerable influence on clinical practice. To our knowledge, there has been no systematic evaluation highlighting the variety of research published in this journal. Therefore, the purpose of this study was to evaluate trends in characteristics of articles published in JBJS from 2012 to 2022, including type of study, level of evidence, author information, and country of publication. Methods: Articles published in JBJS between 2012 and 2022 were retrieved from the JBJS Archives. Title, level of evidence, description of the study as delineated in the abstract, first author degree, number of authors, and country of publication were recorded for each published article. Results: A total of 2668 articles were published in JBJS from 2012 to 2022. The proportion of preclinical studies published per year significantly decreased (P = 0.0025), whereas no statistically significant change was observed in the proportion of clinical studies (P = 0.34). A significant increase was noted in the proportion of database studies published (P = 0.00012). Studies classified as level II decreased over the study period (P = 0.029), whereas level III increased over the study period (P = 0.034). The average number of authors per article was 6 ± 3 authors with a significantly increasing trend over the study period (P = 0.0043). The proportion of first authors who were MD or equivalent decreased (P = 0.025), whereas first authors who were non-MD or non-PhD equivalent increased (P = 0.0068). Conclusion: The publication trends in JBJS over the past decade demonstrate the changing landscape of orthopaedic research as it aims to address the burden of musculoskeletal injury and disease.
- 17 March 2025
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 1-6
Total knee arthroplasty outcomes in patients with a history of radiation therapy
Purpose There is limited information regarding how a history of cancer and related treatment with radiation therapy (RT) impacts outcomes after total knee arthroplasty (TKA). Therefore, our study assessed the risk of developing medical and surgical complications following TKA in patients with cancer as well as those with a history of prior RT. Methods Within a national federated research network, we conducted a retrospective cohort study, querying for patients who underwent a primary TKA from 2002 to 2022. Amongst these patients, we identified three pairs of cohorts: (1) those with and without a history of RT, (2) those with and without a cancer history, and (3) those with a history of cancer who were treated with and without RT. Following propensity-score matching for comorbidities, surgical and medical complications within the 30-day, 90-day, and 1-year postoperative periods were assessed. Results RT was associated with an increased risk of multiple medical complications. When controlling for cancer, patients receiving RT had lower odds of medical complications, and there was no association with these medical complications. Cancer patients had an increased risk of multiple medical complications including venous thromboembolism at all time-intervals. PJI risk was increased at 1-year among cancer patients that received RT compared to those that did not (OR: 1.5, 95% CI: 1.1-2.0). Conclusions While RT may not increase the risk of medical complications, a history of cancer was associated with adverse outcomes following TKA. Our findings serve to help educate this patient population and encourage collaboration with patients’ oncologists during the pre-operative optimization process.
- 17 March 2025
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 1-6
Total knee arthroplasty outcomes in patients with a history of radiation therapy
Purpose There is limited information regarding how a history of cancer and related treatment with radiation therapy (RT) impacts outcomes after total knee arthroplasty (TKA). Therefore, our study assessed the risk of developing medical and surgical complications following TKA in patients with cancer as well as those with a history of prior RT. Methods Within a national federated research network, we conducted a retrospective cohort study, querying for patients who underwent a primary TKA from 2002 to 2022. Amongst these patients, we identified three pairs of cohorts: (1) those with and without a history of RT, (2) those with and without a cancer history, and (3) those with a history of cancer who were treated with and without RT. Following propensity-score matching for comorbidities, surgical and medical complications within the 30-day, 90-day, and 1-year postoperative periods were assessed. Results RT was associated with an increased risk of multiple medical complications. When controlling for cancer, patients receiving RT had lower odds of medical complications, and there was no association with these medical complications. Cancer patients had an increased risk of multiple medical complications including venous thromboembolism at all time-intervals. PJI risk was increased at 1-year among cancer patients that received RT compared to those that did not (OR: 1.5, 95% CI: 1.1-2.0). Conclusions While RT may not increase the risk of medical complications, a history of cancer was associated with adverse outcomes following TKA. Our findings serve to help educate this patient population and encourage collaboration with patients’ oncologists during the pre-operative optimization process.
- Open Access
- 18 February 2025
- Published by SAGE Publications in Global Spine Journal
- Vol. 15 (7) , 3251-3261
Anterior Versus Posterior and Transforaminal Lumbar Interbody Fusion for Spondylolisthesis: A Comparison of Radiographic, Clinical, and Patient Reported Outcomes
Study Design: Retrospective Cohort Study. Objectives: Lumbar spinal fusion is an increasingly utilized surgery within the United States attributed to an aging population with an increasing prevalence of degenerative spinal disease. Primary approaches include anterior lumbar interbody fusion (ALIF) and posterior or transforaminal lumbar interbody fusion (PLIF/TLIF), for which indications are preference driven. This study’s objectives were to compare the clinical, radiographic, and functional outcomes of approaches for lumbar spondylolisthesis. Methods: We conducted a retrospective chart review of 1156 (267 ALIF; 889 PLIF/TLIF) patients who underwent ALIF or PLIF/TLIF due to spondylolisthesis at the L4-5, L5-S1, or L4-S1 levels at a large tertiary referral center from 2010 through 2018. Univariate and multivariable linear and logistic regressions were used to compare outcomes including radiologic fusion, change in lumbar lordosis, postoperative complications, and pre- to postoperative changes in quality-of-life (QoL) variables. Results: Between propensity-weighted cohorts, multivariate regression showed markedly increased odds of radiographic fusion for the ALIF cohort (Odds Ratio [OR]: 2.50, 95% Confidence Interval [CI]: 1.51-4.15). ALIF patients had shorter lengths of stay and less blood loss. However, there was no difference in the odds of reoperation within 1 year or any complications. There was also no significant group difference in change in Cobb angle or in any of the QoL variables. Conclusions: These results indicate that ALIF may have greater radiologic success of fusion. However, when controlling for confounders, there is no difference in clinical outcomes between the approaches. Further research should evaluate the long-term cost-effectiveness of the 2 procedures.
- 18 February 2025
- Published by SAGE Publications in Global Spine Journal
- Vol. 15 (7) , 3251-3261
Open AccessAnterior Versus Posterior and Transforaminal Lumbar Interbody Fusion for Spondylolisthesis: A Comparison of Radiographic, Clinical, and Patient Reported Outcomes
Study Design: Retrospective Cohort Study. Objectives: Lumbar spinal fusion is an increasingly utilized surgery within the United States attributed to an aging population with an increasing prevalence of degenerative spinal disease. Primary approaches include anterior lumbar interbody fusion (ALIF) and posterior or transforaminal lumbar interbody fusion (PLIF/TLIF), for which indications are preference driven. This study’s objectives were to compare the clinical, radiographic, and functional outcomes of approaches for lumbar spondylolisthesis. Methods: We conducted a retrospective chart review of 1156 (267 ALIF; 889 PLIF/TLIF) patients who underwent ALIF or PLIF/TLIF due to spondylolisthesis at the L4-5, L5-S1, or L4-S1 levels at a large tertiary referral center from 2010 through 2018. Univariate and multivariable linear and logistic regressions were used to compare outcomes including radiologic fusion, change in lumbar lordosis, postoperative complications, and pre- to postoperative changes in quality-of-life (QoL) variables. Results: Between propensity-weighted cohorts, multivariate regression showed markedly increased odds of radiographic fusion for the ALIF cohort (Odds Ratio [OR]: 2.50, 95% Confidence Interval [CI]: 1.51-4.15). ALIF patients had shorter lengths of stay and less blood loss. However, there was no difference in the odds of reoperation within 1 year or any complications. There was also no significant group difference in change in Cobb angle or in any of the QoL variables. Conclusions: These results indicate that ALIF may have greater radiologic success of fusion. However, when controlling for confounders, there is no difference in clinical outcomes between the approaches. Further research should evaluate the long-term cost-effectiveness of the 2 procedures.
- 5 February 2025
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 483 (6) , 972-990
Is Your Surgical Helmet System Compromising the Sterile Field? A Systematic Review of Contamination Risks and Preventive Measures in Total Joint Arthroplasty
Background: Surgical helmet systems remain widely used in total joint arthroplasty (TJA) despite evidence to suggest that they may increase infection risk via contamination of sterile equipment and operating room air. However, the challenging nature of conducting high-quality clinical trials to study outcomes with low incidence, such as prosthetic joint infection (PJI), has made drawing definitive conclusions from the available experimental studies difficult. Therefore, a comprehensive analysis of the best available evidence is needed to clarify the association between surgical helmet system use and contamination and infection risk and to provide clinical recommendations for use in TJA. Questions/purposes: This systematic review aimed to address the following questions: (1) What is the level of sterility of surgical helmet systems and concomitantly used personal protective equipment (PPE)? (2) Is there an association between surgical helmet systems and air contamination within the operating room? (3) Does the use of a surgical helmet system affect wound contamination and/or infection? Methods: PubMed, Medline, EBSCOhost, and Google Scholar were queried on July 31, 2024, to identify studies published from inception to July 2024 that have evaluated the impact of surgical helmet system use in TJA on sterile field contamination (operating room air, PPE, sterile equipment), wound contamination and infection, or practices that may impact related outcomes. Inclusion criteria were that the study evaluate the sterility, donning, or intraoperative use (including mock TJA) of a surgical helmet system in association with contamination or infection. The following articles were excluded: case reports, case series, reviews, commentaries, editorials, duplicate studies among databases, gray literature, studies specific to a procedure other than TJA, and studies unavailable as a full-text English manuscript. After screening 536 articles, 21 were included. The 13 studies that evaluated the sterility of surgical helmet systems and concomitantly used PPE comprised 126 gowning simulations, 445 mock TJA procedures, and 191 patients who had undergone TJA. The seven studies that evaluated contamination of operating room air comprised 38 gowning simulations, 82 mock TJA procedures, and 96 patients who had undergone TJA. Three studies directly evaluated wound contamination or infection, comprising 83,888 patients who had undergone TJA. Risk of bias was determined via the Methodological Index for Nonrandomized Studies (MINORS) tool, with a mean ± SD score of 20 ± 1.4 (of 24) for comparative studies and 14 ± 0.8 (of 16) for noncomparative studies, indicating good study quality. Notably, the quality of evidence was limited by the inclusion of experimental study designs that did not directly measure infection; however, the inclusion of such studies is necessitated by the infeasibly large study population required to directly evaluate the association between surgical helmet systems and infection prospectively. Heterogeneity among studies precluded meta-analysis, and a qualitative synthesis was instead conducted. Results: The best available evidence suggests that surgical helmet systems frequently harbor microbes known to be common causes of SSI and PJI, and that their improper donning and use (for example, activation of the exhaust fan before fully gowned) can lead to the contamination of gowns and sterile gloves worn by surgical personnel. Furthermore, several studies suggest that the exhaust from surgical helmet systems presents a potential source of operating room air contamination, although there were mixed findings based on the location of air sampling and whether or not a toga was used and the gown-glove interface was sealed (both of which were shown to mitigate airborne contaminants). However, whether there is a direct association between surgical helmet system use and wound infection remains understudied and unclear, with one retrospective comparative analysis demonstrating no difference in odds of infection when comparing surgical helmet systems used to a standard gown during TJA, and another reporting reduced odds of revision for deep infection with a 12-month follow-up time when a surgical helmet system was used (adjusted OR 0.55). Conclusion: Although the best available evidence suggests that the use of surgical helmet systems in TJA can increase the likelihood of sterile field contamination, including sterile surgical attire and equipment, as well as operating room air, that finding derives largely from experimental studies with effect sizes (based on endpoints like colony counts) that are difficult or impossible to convert to real-world infection risk. Robust investigations into the association between surgical helmet systems and infection are limited by the need for infeasibly large study populations to conduct sufficiently powered clinical trials, with no evidence found by this review to directly implicate surgical helmet systems in increased infection risk. Still, because the risk for contamination has been shown to be driven substantially by donning technique and the type of gown used, we recommend waiting to activate the surgical helmet system fan until fully gowned, taping the gown cuff at the inner glove, utilizing a toga system set up, and implementing sterilization protocols for reusable helmets. Clinical Relevance: When used appropriately, there is insufficient high-quality evidence to suggest that surgical helmet systems pose meaningful harm to patient safety. However, the persistent lack of evidence to demonstrate their effectiveness in achieving the initial purpose of reducing infection warrants careful evaluation of their utility in TJA. Ample consideration must be given to their role as personal protection systems for surgical personnel, as studies have demonstrated superior protection from surgical debris and splatter compared with conventional surgical attire. While...
- 5 February 2025
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 483 (6) , 972-990
Is Your Surgical Helmet System Compromising the Sterile Field? A Systematic Review of Contamination Risks and Preventive Measures in Total Joint Arthroplasty
Background: Surgical helmet systems remain widely used in total joint arthroplasty (TJA) despite evidence to suggest that they may increase infection risk via contamination of sterile equipment and operating room air. However, the challenging nature of conducting high-quality clinical trials to study outcomes with low incidence, such as prosthetic joint infection (PJI), has made drawing definitive conclusions from the available experimental studies difficult. Therefore, a comprehensive analysis of the best available evidence is needed to clarify the association between surgical helmet system use and contamination and infection risk and to provide clinical recommendations for use in TJA. Questions/purposes: This systematic review aimed to address the following questions: (1) What is the level of sterility of surgical helmet systems and concomitantly used personal protective equipment (PPE)? (2) Is there an association between surgical helmet systems and air contamination within the operating room? (3) Does the use of a surgical helmet system affect wound contamination and/or infection? Methods: PubMed, Medline, EBSCOhost, and Google Scholar were queried on July 31, 2024, to identify studies published from inception to July 2024 that have evaluated the impact of surgical helmet system use in TJA on sterile field contamination (operating room air, PPE, sterile equipment), wound contamination and infection, or practices that may impact related outcomes. Inclusion criteria were that the study evaluate the sterility, donning, or intraoperative use (including mock TJA) of a surgical helmet system in association with contamination or infection. The following articles were excluded: case reports, case series, reviews, commentaries, editorials, duplicate studies among databases, gray literature, studies specific to a procedure other than TJA, and studies unavailable as a full-text English manuscript. After screening 536 articles, 21 were included. The 13 studies that evaluated the sterility of surgical helmet systems and concomitantly used PPE comprised 126 gowning simulations, 445 mock TJA procedures, and 191 patients who had undergone TJA. The seven studies that evaluated contamination of operating room air comprised 38 gowning simulations, 82 mock TJA procedures, and 96 patients who had undergone TJA. Three studies directly evaluated wound contamination or infection, comprising 83,888 patients who had undergone TJA. Risk of bias was determined via the Methodological Index for Nonrandomized Studies (MINORS) tool, with a mean ± SD score of 20 ± 1.4 (of 24) for comparative studies and 14 ± 0.8 (of 16) for noncomparative studies, indicating good study quality. Notably, the quality of evidence was limited by the inclusion of experimental study designs that did not directly measure infection; however, the inclusion of such studies is necessitated by the infeasibly large study population required to directly evaluate the association between surgical helmet systems and infection prospectively. Heterogeneity among studies precluded meta-analysis, and a qualitative synthesis was instead conducted. Results: The best available evidence suggests that surgical helmet systems frequently harbor microbes known to be common causes of SSI and PJI, and that their improper donning and use (for example, activation of the exhaust fan before fully gowned) can lead to the contamination of gowns and sterile gloves worn by surgical personnel. Furthermore, several studies suggest that the exhaust from surgical helmet systems presents a potential source of operating room air contamination, although there were mixed findings based on the location of air sampling and whether or not a toga was used and the gown-glove interface was sealed (both of which were shown to mitigate airborne contaminants). However, whether there is a direct association between surgical helmet system use and wound infection remains understudied and unclear, with one retrospective comparative analysis demonstrating no difference in odds of infection when comparing surgical helmet systems used to a standard gown during TJA, and another reporting reduced odds of revision for deep infection with a 12-month follow-up time when a surgical helmet system was used (adjusted OR 0.55). Conclusion: Although the best available evidence suggests that the use of surgical helmet systems in TJA can increase the likelihood of sterile field contamination, including sterile surgical attire and equipment, as well as operating room air, that finding derives largely from experimental studies with effect sizes (based on endpoints like colony counts) that are difficult or impossible to convert to real-world infection risk. Robust investigations into the association between surgical helmet systems and infection are limited by the need for infeasibly large study populations to conduct sufficiently powered clinical trials, with no evidence found by this review to directly implicate surgical helmet systems in increased infection risk. Still, because the risk for contamination has been shown to be driven substantially by donning technique and the type of gown used, we recommend waiting to activate the surgical helmet system fan until fully gowned, taping the gown cuff at the inner glove, utilizing a toga system set up, and implementing sterilization protocols for reusable helmets. Clinical Relevance: When used appropriately, there is insufficient high-quality evidence to suggest that surgical helmet systems pose meaningful harm to patient safety. However, the persistent lack of evidence to demonstrate their effectiveness in achieving the initial purpose of reducing infection warrants careful evaluation of their utility in TJA. Ample consideration must be given to their role as personal protection systems for surgical personnel, as studies have demonstrated superior protection from surgical debris and splatter compared with conventional surgical attire. While...