Gokce Soganci Unsal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gokce Soganci Unsal has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Filiz Aykent
Department of Prosthodontics, Ankara Yıldırım Beyazıt University Faculty of Dentistry, Ankara, Turkey
2 shared publications - Zeynep İlKe Tan2 shared publications
- Abdulhaluk Savaş
Necmettin Erbakan University, Faculty of Dentistry, Department of Prosthodontics, Konya, Turkey
1 shared publication - Ahmed Mohammed Rashed Elsayed Abdalla1 shared publication
- Ahmet Haydar Parlak1 shared publication
- Aleyna Öykü Akbaşak Sungur
BAŞKENT ÜNİVERSİTESİ, DİŞ HEKİMLİĞİ FAKÜLTESİ
1 shared publication
Latest Publications
- Open Access
- 5 August 2026
- Published by Springer Nature in BMC Oral Health
- Vol. 26 (1) , 1401
Color stability of polyetheretherketone and graphene-reinforced polymethyl methacrylate after in-office bleaching
- 5 August 2026
- Published by Springer Nature in BMC Oral Health
- Vol. 26 (1) , 1401
Open AccessColor stability of polyetheretherketone and graphene-reinforced polymethyl methacrylate after in-office bleaching
- 23 April 2026
- Published by Academician Publishing
- p. 169-194
Oklüzal Kuvvetler ve Diş Hekimliğinde Sonlu Elemanlar Analizi
- 23 April 2026
- Published by Academician Publishing
- p. 169-194
Oklüzal Kuvvetler ve Diş Hekimliğinde Sonlu Elemanlar Analizi
- Open Access
- 26 September 2025
- Published by Academician Publishing
- p. 281-308
Temporamandibular Eklem Rahatsızlıklarında Tanı ve Tedavi Yöntemleri
Çiğneme sistemi; konuşma, yutma ve besinlerin parçalanması gibi temel fonksiyonları üstlenen kemikler, kaslar, bağlar ve dişlerden oluşan karmaşık bir yapıdır. Bu sistemin merkezinde yer alan temporomandibular eklem (TME), mandibular kondil ile temporal kemiğin mandibular fossası arasında yer alıp, artiküler disk aracılığıyla hem rotasyon hem translasyon hareketlerine olanak tanır. TME rahatsızlıkların (TMR) başlıca belirtiler; ağrı, hareket kısıtlılığı, klik/krepitasyon ve baş–kulak–şakak bölgesine yayılan ağrılardır. Rahatsızlıklar multifaktöriyeldir; travmalar, parafonksiyonel alışkanlıklar (bruksizm), oklüzal uyumsuzluklar, bağ dokusu zayıflığı ve inflamasyon. Klinik tablolar arasında kas kökenli ağrılar, kondil-disk düzensizlikleri, inflamatuvar hastalıklar ve osteoartrit öne çıkar. Tanıda ayrıntılı anamnez, sistematik muayene ve görüntüleme yöntemleri birlikte kullanılır. Manyetik Rezonans Görüntüleme disk ve yumuşak dokular için altın standarttır; Bilgisayarlı Tomografi kemik yapıları, panoramik radyografi genel taramayı, ultrasonografi ise invaziv olmayan hızlı bir alternatifi sunar. Bruksizm, çoğunlukla uykuda ortaya çıkan, diş sıkma ve gıcırdatma ile karakterize parafonksiyonel bir alışkanlıktır. Normalden uzun süreli ve farklı yönlü yüklenmeler çene eklemi ve dişlerde yıkıcı etki yaratır. Dişlerde aşınma, dil kenarında dalgalı izler ve kas hassasiyeti tipik bulgularıdır. Tedavi yaklaşımı öncelikle konservatiftir: hasta eğitimi, stres yönetimi, fizik tedavi, farmakoterapi ve oklüzal splintler ön plandadır. Stabilizasyon splintleri özellikle bruksizm ve kas ağrısında etkilidir. İleri olgularda cerrahi ve botoks gibi alternatif yöntemleri uygulanabilir.
- 26 September 2025
- Published by Academician Publishing
- p. 281-308
Open AccessTemporamandibular Eklem Rahatsızlıklarında Tanı ve Tedavi Yöntemleri
Çiğneme sistemi; konuşma, yutma ve besinlerin parçalanması gibi temel fonksiyonları üstlenen kemikler, kaslar, bağlar ve dişlerden oluşan karmaşık bir yapıdır. Bu sistemin merkezinde yer alan temporomandibular eklem (TME), mandibular kondil ile temporal kemiğin mandibular fossası arasında yer alıp, artiküler disk aracılığıyla hem rotasyon hem translasyon hareketlerine olanak tanır. TME rahatsızlıkların (TMR) başlıca belirtiler; ağrı, hareket kısıtlılığı, klik/krepitasyon ve baş–kulak–şakak bölgesine yayılan ağrılardır. Rahatsızlıklar multifaktöriyeldir; travmalar, parafonksiyonel alışkanlıklar (bruksizm), oklüzal uyumsuzluklar, bağ dokusu zayıflığı ve inflamasyon. Klinik tablolar arasında kas kökenli ağrılar, kondil-disk düzensizlikleri, inflamatuvar hastalıklar ve osteoartrit öne çıkar. Tanıda ayrıntılı anamnez, sistematik muayene ve görüntüleme yöntemleri birlikte kullanılır. Manyetik Rezonans Görüntüleme disk ve yumuşak dokular için altın standarttır; Bilgisayarlı Tomografi kemik yapıları, panoramik radyografi genel taramayı, ultrasonografi ise invaziv olmayan hızlı bir alternatifi sunar. Bruksizm, çoğunlukla uykuda ortaya çıkan, diş sıkma ve gıcırdatma ile karakterize parafonksiyonel bir alışkanlıktır. Normalden uzun süreli ve farklı yönlü yüklenmeler çene eklemi ve dişlerde yıkıcı etki yaratır. Dişlerde aşınma, dil kenarında dalgalı izler ve kas hassasiyeti tipik bulgularıdır. Tedavi yaklaşımı öncelikle konservatiftir: hasta eğitimi, stres yönetimi, fizik tedavi, farmakoterapi ve oklüzal splintler ön plandadır. Stabilizasyon splintleri özellikle bruksizm ve kas ağrısında etkilidir. İleri olgularda cerrahi ve botoks gibi alternatif yöntemleri uygulanabilir.
- Open Access
- 26 September 2025
- Published by Academician Publishing
Güncel Protetik Diş Tedavisi Çalışmaları IX ( AYBAK 2025 Güz )
- 26 September 2025
- Published by Academician Publishing
Open AccessGüncel Protetik Diş Tedavisi Çalışmaları IX ( AYBAK 2025 Güz )
- 1 March 2023
- Published by Quintessence Publishing in The International Journal of Prosthodontics
- Vol. 36 (2) , 203-215
Finite Element Analysis of Endocrowns and Post-and-Core Abutments for Removable Partial Dentures with Different Framework Materials
Gokce Soganci Unsal, DDS, PhD/Selen Ince Yusufoglu, DDS, PhD: Purpose: To evaluate the stress distribution in endocrowns and post-and-core crowns used as abutments for a Kennedy Class I removable partial denture constructed with different framework materials. Materials and Methods: 3D models of a Kennedy Class I mandible were constructed. Cobalt-chromium (Co-Cr) and polyether ether ketone (PEEK) frameworks were simulated for Models 1 and 2. An endocrown and a fiber post-and-core crown for the mandibular left and right second premolar abutments were simulated for both models, respectively. Lithium disilicate porcelain was defined for the crowns. A 200-N occlusal force was applied in the vertical and 30-degree oblique directions. Results: The von Mises stresses were evaluated for the abutments and prostheses, and the principal stresses for the cortical bone under vertical and oblique loadings. Endocrowns showed lower stress values than post-and-core crowns in both models. Post-and-core porcelain crowns generated the highest stress in Model 2 under vertical loading. PEEK framework caused higher stress values on abutments than Co-Cr. Compressive stresses were higher than tensile stresses in cortical bone. The highest compressive stress was observed around the left premolar cortical bone area in Model 1 under oblique loading. Oblique loading caused lower stress values than vertical loading, except for on the minor connectors and cortical bone. Conclusion: From a biomechanical perspective, endocrowns may be more advantageous than post-and-core crowns when used as abutments for a Kennedy Class I removable partial denture. In addition, Co-Cr frameworks show more favorable stress distribution on abutments than PEEK frameworks.
- 1 March 2023
- Published by Quintessence Publishing in The International Journal of Prosthodontics
- Vol. 36 (2) , 203-215
Finite Element Analysis of Endocrowns and Post-and-Core Abutments for Removable Partial Dentures with Different Framework Materials
Gokce Soganci Unsal, DDS, PhD/Selen Ince Yusufoglu, DDS, PhD: Purpose: To evaluate the stress distribution in endocrowns and post-and-core crowns used as abutments for a Kennedy Class I removable partial denture constructed with different framework materials. Materials and Methods: 3D models of a Kennedy Class I mandible were constructed. Cobalt-chromium (Co-Cr) and polyether ether ketone (PEEK) frameworks were simulated for Models 1 and 2. An endocrown and a fiber post-and-core crown for the mandibular left and right second premolar abutments were simulated for both models, respectively. Lithium disilicate porcelain was defined for the crowns. A 200-N occlusal force was applied in the vertical and 30-degree oblique directions. Results: The von Mises stresses were evaluated for the abutments and prostheses, and the principal stresses for the cortical bone under vertical and oblique loadings. Endocrowns showed lower stress values than post-and-core crowns in both models. Post-and-core porcelain crowns generated the highest stress in Model 2 under vertical loading. PEEK framework caused higher stress values on abutments than Co-Cr. Compressive stresses were higher than tensile stresses in cortical bone. The highest compressive stress was observed around the left premolar cortical bone area in Model 1 under oblique loading. Oblique loading caused lower stress values than vertical loading, except for on the minor connectors and cortical bone. Conclusion: From a biomechanical perspective, endocrowns may be more advantageous than post-and-core crowns when used as abutments for a Kennedy Class I removable partial denture. In addition, Co-Cr frameworks show more favorable stress distribution on abutments than PEEK frameworks.
- 24 August 2022
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 9 (2) , 527-532
Evaluation of the Effect of Fracture Line Type on Repair Resistance in Acrylic Resins Repaired with Graphene Oxide
AMAÇ: Farklı kırık hattı şekillerinin ve aralıklarının grafen oksit ile tamir edilmiş polimetil metakrilat (PMMA) rezin örneklerinin kırılma dayanımına olan etkisinin araştırılmasıdır. GEREÇ VE YÖNTEMLER: 65×10×3 mm boyutunda 50 adet standart mum örnek metal bir kalıp kullanılarak hazırlandı. Hazırlanan mum örnekler 5 gruba (n=10) ayrıldı; grup 1: kontrol grubu (kırık hattı oluşturulmayan), grup 2: 0 mm boşluk ve düz yüzeyli kırık hattı, grup 3: 0 mm boşluk ve 45° bevel kırık hattı, grup 4: 2.5 mm boşluk ve düz yüzeyli kırık hattı, grup 5: 2.5 mm boşluk ve 45° bevel kırık hattı. Örneklerin kırık hattı PMMA tozuna %2 oranında grafen oksit ilave edilerek tamir edildi. Tüm gruplardaki örneklere başlık hızı 0.5 mm/dak olan universal test cihazı ile 3 nokta bükülme testi kırık hattının orta noktasından uygulandı. Sonuçlar normal dağılım gösteren gruplarda ANOVA ve Tukey HSD testi kullanılarak, normal dağılım göstermeyen gruplarda ise Kruskall-Wallis H testi ile değerlendirildi. p<0,05 değeri istatistiksel olarak anlamlı kabul edildi. BULGULAR: En yüksek bükülme dayanımı değeri kontrol grubunda elde edildi. (123.92±13.99 MPa). En düşük değer ise grup 4’te (39.01±8.23 MPa) kaydedildi. Bevel kırık hattı oluşturulan örneklerin bükülme dayanımı, düz kırık hatlı örneklerden istatistiksel olarak anlamlı derecede daha yüksek bulundu. (p<0,05). Çalışmada tamir sonrası örneklerin reziliensinde azalma gözlenmiş ancak gruplar arası fark istatistiksel olarak anlamlı bulunmamıştır. (p=0,083). SONUÇ: Grafen oksit kullanılarak tamir edilen akrilik rezin örneklerde bevel kırık hattı düz kırık hattına göre kırılma dayanımının artırılmasında önemli derecede avantaj sağlamıştır.
- 24 August 2022
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 9 (2) , 527-532
Evaluation of the Effect of Fracture Line Type on Repair Resistance in Acrylic Resins Repaired with Graphene Oxide
AMAÇ: Farklı kırık hattı şekillerinin ve aralıklarının grafen oksit ile tamir edilmiş polimetil metakrilat (PMMA) rezin örneklerinin kırılma dayanımına olan etkisinin araştırılmasıdır. GEREÇ VE YÖNTEMLER: 65×10×3 mm boyutunda 50 adet standart mum örnek metal bir kalıp kullanılarak hazırlandı. Hazırlanan mum örnekler 5 gruba (n=10) ayrıldı; grup 1: kontrol grubu (kırık hattı oluşturulmayan), grup 2: 0 mm boşluk ve düz yüzeyli kırık hattı, grup 3: 0 mm boşluk ve 45° bevel kırık hattı, grup 4: 2.5 mm boşluk ve düz yüzeyli kırık hattı, grup 5: 2.5 mm boşluk ve 45° bevel kırık hattı. Örneklerin kırık hattı PMMA tozuna %2 oranında grafen oksit ilave edilerek tamir edildi. Tüm gruplardaki örneklere başlık hızı 0.5 mm/dak olan universal test cihazı ile 3 nokta bükülme testi kırık hattının orta noktasından uygulandı. Sonuçlar normal dağılım gösteren gruplarda ANOVA ve Tukey HSD testi kullanılarak, normal dağılım göstermeyen gruplarda ise Kruskall-Wallis H testi ile değerlendirildi. p<0,05 değeri istatistiksel olarak anlamlı kabul edildi. BULGULAR: En yüksek bükülme dayanımı değeri kontrol grubunda elde edildi. (123.92±13.99 MPa). En düşük değer ise grup 4’te (39.01±8.23 MPa) kaydedildi. Bevel kırık hattı oluşturulan örneklerin bükülme dayanımı, düz kırık hatlı örneklerden istatistiksel olarak anlamlı derecede daha yüksek bulundu. (p<0,05). Çalışmada tamir sonrası örneklerin reziliensinde azalma gözlenmiş ancak gruplar arası fark istatistiksel olarak anlamlı bulunmamıştır. (p=0,083). SONUÇ: Grafen oksit kullanılarak tamir edilen akrilik rezin örneklerde bevel kırık hattı düz kırık hattına göre kırılma dayanımının artırılmasında önemli derecede avantaj sağlamıştır.