Emine Tuna Akdoğan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Emine Tuna Akdoğan has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Mustafa Demir
Department Nuclear Medicine, Cerrahpasa Medicine Faculty, Istanbul University - Cerrahpasa, Istanbul, Türkiye
4 shared publications - Nami Yeyin
Department Nuclear Medicine, Cerrahpasa Medicine Faculty, Istanbul University - Cerrahpasa, Istanbul, Türkiye
2 shared publications Sinem Coşkun
Department Nuclear Medicine, Cerrahpasa Medicine Faculty, Istanbul University - Cerrahpasa, Istanbul, Türkiye
2 shared publications- Elif Aslı GÜLŞEN
Assistant Professor, Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Zonguldak Bülent Ecevit University, Zonguldak, Türkiye
1 shared publication - Enes Malik Pınarbaşı
Faculty of Dentistry, Department of Oral and Maxillofacial Surgery, Istanbul Kent University, Istanbul Türkiye
1 shared publication - Ghada Almisned
Department of Physics, College of Science, Princess Nourah Bint AbdulRahman University, Riyadh, Saudi Arabia
1 shared publication
Latest Publications
- 23 September 2026
- Published by Bentham Science Publishers Ltd. in Current Medical Imaging
- Vol. 22, 1-14
Effects of Dental Metal Implant Number and Configuration on PET/CT Quantification and Image Quality: A Phantom-Based Study
Introduction/Objectives: Dental metal implants can generate artifacts in PET/CT imaging, particularly in the head and neck region, affecting quantitative accuracy. This study evaluated variations in standardized uptake value (SUV), contrast (C), and contrast-to-noise ratio (CNR) across predefined dental implant configurations differing in both implant number and spatial arrangement and assessed their effects on simulated tongue, nasopharyngeal, and laryngeal lesions. Methods: A custom-designed head and neck phantom containing extracted human teeth and up to eight titanium dental implants was used. Simulated tongue, nasopharyngeal, and laryngeal tumors were filled with F-18 FDG. PET/CT scans were acquired using seven implant configurations (0–8 implants) and reconstructed as attenuation-corrected (AC), AC with metal artifact reduction (AC+MAR), and non-attenuation-corrected (NoAC) images. SUV, contrast, and CNR were calculated using standardized ROIs. Results: Compared with the implant-free configuration, tongue tumor SUV decreased by 11% and 9.1% on AC and AC+MAR images, respectively, at eight implants. Nasopharyngeal and laryngeal SUV showed only minimal descriptive change with increasing implant number and configurations on AC+MAR images. Contrast and CNR followed similar trends on AC and AC+MAR images, whereas NoAC images consistently showed substantially lower contrast and CNR regardless of implant number. Discussion: Although MAR reduced implant-induced artifacts and partially attenuated SUV underestimation, it did not eliminate the configuration-dependent trend observed across the predefined implant arrangements. Lesions farther from the implants appeared less affected after MAR; however, this should be regarded as a hypothesis-generating observation from a single phantom experiment, requiring validation in patient studies and phantom models with varying implant-to-lesion distances. Conclusion: Dental implants may affect PET/CT quantification, particularly for lesions adjacent to multiple implants; SUV measurements in these regions should be interpreted with caution.
- 23 September 2026
- Published by Bentham Science Publishers Ltd. in Current Medical Imaging
- Vol. 22, 1-14
Effects of Dental Metal Implant Number and Configuration on PET/CT Quantification and Image Quality: A Phantom-Based Study
Introduction/Objectives: Dental metal implants can generate artifacts in PET/CT imaging, particularly in the head and neck region, affecting quantitative accuracy. This study evaluated variations in standardized uptake value (SUV), contrast (C), and contrast-to-noise ratio (CNR) across predefined dental implant configurations differing in both implant number and spatial arrangement and assessed their effects on simulated tongue, nasopharyngeal, and laryngeal lesions. Methods: A custom-designed head and neck phantom containing extracted human teeth and up to eight titanium dental implants was used. Simulated tongue, nasopharyngeal, and laryngeal tumors were filled with F-18 FDG. PET/CT scans were acquired using seven implant configurations (0–8 implants) and reconstructed as attenuation-corrected (AC), AC with metal artifact reduction (AC+MAR), and non-attenuation-corrected (NoAC) images. SUV, contrast, and CNR were calculated using standardized ROIs. Results: Compared with the implant-free configuration, tongue tumor SUV decreased by 11% and 9.1% on AC and AC+MAR images, respectively, at eight implants. Nasopharyngeal and laryngeal SUV showed only minimal descriptive change with increasing implant number and configurations on AC+MAR images. Contrast and CNR followed similar trends on AC and AC+MAR images, whereas NoAC images consistently showed substantially lower contrast and CNR regardless of implant number. Discussion: Although MAR reduced implant-induced artifacts and partially attenuated SUV underestimation, it did not eliminate the configuration-dependent trend observed across the predefined implant arrangements. Lesions farther from the implants appeared less affected after MAR; however, this should be regarded as a hypothesis-generating observation from a single phantom experiment, requiring validation in patient studies and phantom models with varying implant-to-lesion distances. Conclusion: Dental implants may affect PET/CT quantification, particularly for lesions adjacent to multiple implants; SUV measurements in these regions should be interpreted with caution.
- Open Access
- 15 September 2026
- Published by AVES YAYINCILIK A.Ş. in Essentials of Dentistry
- Vol. 5
An In-Depth Evaluation of Radiation Safety in Dental Facilities for Tc-99m MIBI Patients Undergoing Nuclear Medicine Myocardial Perfusion Scintigraphy
Background: This study aimed to determine the radiation doses that may be received by dentists when examining or performing interventional procedures on patients who have undergone myocardial perfusion scintigraphy (MPS) for the evaluation of ischemic or scarred myocardial regions. Additionally, it sought to identify appropriate radiation protection measures from the perspective of dental practitioners. Methods: A total of 37 patients undergoing MPS were included in the study. Each patient received a cumulative activity of 1110 megabecquerels (MBq) of technetium 99m methoxy isobutyl isonitrile (Tc-99m MIBI) for stress and rest imaging. Following both stress and rest imaging, radiation dose rate measurements were obtained using a radiation detector from the neck, thoracic, and abdominopelvic regions at distances of 5 cm, 15 cm, 30 cm, 60 cm, and 100 cm within 0.5-3.0 hours after radiopharmaceutical administration. Results: The mean dose rates measured from the thoracic region at 5 cm, 15 cm, 30 cm, 60 cm, and 100 cm distances were 156.7 ± 23.5 μSv/h, 134.3 ± 23.2 μSv/h, 79.7 ± 29.6 μSv/h, 34.1 ± 17.6 μSv/h, and 15.1 ± 5.9 μSv/h, respectively. Conclusion: From a radiation safety perspective, it was determined that a patient who has undergone MPS can safely undergo dental examination and treatment at least 7 hours after imaging. For pregnant dental practitioners, a minimum waiting period of 10 hours is recommended to ensure radiological safety.
- 15 September 2026
- Published by AVES YAYINCILIK A.Ş. in Essentials of Dentistry
- Vol. 5
Open AccessAn In-Depth Evaluation of Radiation Safety in Dental Facilities for Tc-99m MIBI Patients Undergoing Nuclear Medicine Myocardial Perfusion Scintigraphy
Background: This study aimed to determine the radiation doses that may be received by dentists when examining or performing interventional procedures on patients who have undergone myocardial perfusion scintigraphy (MPS) for the evaluation of ischemic or scarred myocardial regions. Additionally, it sought to identify appropriate radiation protection measures from the perspective of dental practitioners. Methods: A total of 37 patients undergoing MPS were included in the study. Each patient received a cumulative activity of 1110 megabecquerels (MBq) of technetium 99m methoxy isobutyl isonitrile (Tc-99m MIBI) for stress and rest imaging. Following both stress and rest imaging, radiation dose rate measurements were obtained using a radiation detector from the neck, thoracic, and abdominopelvic regions at distances of 5 cm, 15 cm, 30 cm, 60 cm, and 100 cm within 0.5-3.0 hours after radiopharmaceutical administration. Results: The mean dose rates measured from the thoracic region at 5 cm, 15 cm, 30 cm, 60 cm, and 100 cm distances were 156.7 ± 23.5 μSv/h, 134.3 ± 23.2 μSv/h, 79.7 ± 29.6 μSv/h, 34.1 ± 17.6 μSv/h, and 15.1 ± 5.9 μSv/h, respectively. Conclusion: From a radiation safety perspective, it was determined that a patient who has undergone MPS can safely undergo dental examination and treatment at least 7 hours after imaging. For pregnant dental practitioners, a minimum waiting period of 10 hours is recommended to ensure radiological safety.
- 26 August 2026
- Published by Elsevier in Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
- Vol. 143 (1) , 66-74
Postdischarge radiation exposure from I-131–treated patients with thyroid cancer: implications for dental practice
- 26 August 2026
- Published by Elsevier in Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
- Vol. 143 (1) , 66-74
Postdischarge radiation exposure from I-131–treated patients with thyroid cancer: implications for dental practice
- 24 March 2026
- Published by Adnan Menderes University in Meandros Medical and Dental Journal
- Vol. 27 (1) , 116-123
A Comprehensive Assessment of Radiation Protection Practices in Dental Clinics for Patients Administered 99mTc Mdp Undergoing Bone Scintigraphy
Objective: This study aimed to determine the potential radiation doses to which dentists may be exposed when examining or performing interventional procedures on patients who have undergone technetium-99m methylene diphosphonate (⁹⁹ᵐTc-MDP) bone scintigraphy, primarily performed for the evaluation of bone malignancies. In addition, it sought to identify appropriate radiation protection measures from the perspective of dental practitioners. Materials and Methods: A total of 53 patients who underwent bone scintigraphy were included in this study. Each patient received an average of 925 megabecquerels (MBq) of ⁹⁹ᵐTc-MDP as a radiopharmaceutical. Two hours after administration, bone scintigraphy imaging was performed. Between 0.5 and 3 hours after imaging, radiation dose rate measurements were obtained from the head–neck, thoracic, and abdominopelvic regions using a radiation detector positioned at distances of 5 cm, 15 cm, 30 cm, 60 cm, and 100 cm. Results: The mean dose rates measured from the thoracic region at 5 cm, 15 cm, 30 cm, 60 cm, and 100 cm were 144.3 ± 36.9, 107.2 ± 16.9, 73.5 ± 13.8, 42.7 ± 10.0, and 12.5 ± 8.7 µSv/h, respectively. It was estimated that the daily exposure dose to a dentist would be below 4 µSv after approximately 10.4 hours of patient contact. Conclusion: If a patient who has undergone bone scintigraphy visits a dentist for examination or treatment 3 hours after imaging, the dentist’s radiation exposure would remain below the annual dose limit of 1 mSv. However, it was also determined that the 4 µSv/day exposure threshold could be reached after approximately 10.4 hours of close contact.
- 24 March 2026
- Published by Adnan Menderes University in Meandros Medical and Dental Journal
- Vol. 27 (1) , 116-123
A Comprehensive Assessment of Radiation Protection Practices in Dental Clinics for Patients Administered 99mTc Mdp Undergoing Bone Scintigraphy
Objective: This study aimed to determine the potential radiation doses to which dentists may be exposed when examining or performing interventional procedures on patients who have undergone technetium-99m methylene diphosphonate (⁹⁹ᵐTc-MDP) bone scintigraphy, primarily performed for the evaluation of bone malignancies. In addition, it sought to identify appropriate radiation protection measures from the perspective of dental practitioners. Materials and Methods: A total of 53 patients who underwent bone scintigraphy were included in this study. Each patient received an average of 925 megabecquerels (MBq) of ⁹⁹ᵐTc-MDP as a radiopharmaceutical. Two hours after administration, bone scintigraphy imaging was performed. Between 0.5 and 3 hours after imaging, radiation dose rate measurements were obtained from the head–neck, thoracic, and abdominopelvic regions using a radiation detector positioned at distances of 5 cm, 15 cm, 30 cm, 60 cm, and 100 cm. Results: The mean dose rates measured from the thoracic region at 5 cm, 15 cm, 30 cm, 60 cm, and 100 cm were 144.3 ± 36.9, 107.2 ± 16.9, 73.5 ± 13.8, 42.7 ± 10.0, and 12.5 ± 8.7 µSv/h, respectively. It was estimated that the daily exposure dose to a dentist would be below 4 µSv after approximately 10.4 hours of patient contact. Conclusion: If a patient who has undergone bone scintigraphy visits a dentist for examination or treatment 3 hours after imaging, the dentist’s radiation exposure would remain below the annual dose limit of 1 mSv. However, it was also determined that the 4 µSv/day exposure threshold could be reached after approximately 10.4 hours of close contact.
- 19 September 2022
- Published by Ankara Dis Hekimleri Odasi in ADO Klinik Bilimler Dergisi
- Vol. 11 (3) , 215-219
Temporomandibuler Eklem Hastalıklarının Teşhisinde MRG Altın Standart Mıdır?
Amaç; Bu retrospektif çalışmanın amacı temporomandibular eklem bozukluğu (TMD) şikâyeti ile kliniğe gelen ve daha önceden manyetik rezonans görüntülemesi (MRG) olan hastalarda klinik bulgular ve MRG bulguları arasındaki ilişkiyi değerlendirmektir. Gereç ve yöntem; Temporomandibular eklem bozukluğu (TMD) şikayeti ile gelen ve MR bulguları ve klinik muayene bulguları kaydedilmiş 85 hasta değerlendirildi. TME, MRG ve klinik muayene bulguları, çene ağrısı, ağız açıklığında kısıtlanma şikayetleri ve MR isteminin hangi bölüm tarafından yapıldığı retrospektif olarak değerlendirildi. Veriler SPSS 19 ile analiz edildi. Sayısal veriler ortalama ± standart sapma şeklinde sunuldu. Kategorik verilerin karşılaştırılmasında ki-kare testi kullanıldı. P<0.05 istatistiksel olarak önemli kabul edildi. Bulgular; Bu çalışmada 85 hastanın MRG sonuçları ve klinik bulguları retrospektif olarak incelendi. 85 hastanın 71’inin (%83,5) klinik ve MRG Bulguları arasında korelasyon bulundu. 14 hastanın (%16,5) bulguları uyumsuz bulundu. Sonuç; Çalışmanın sonuçlarında klinik muayene bulguları ile MRG bulguları arasında yüksek uyumluluk olduğu saptanmıştır. Konu hakkında daha yüksek hasta sayısı ve daha uzun süreli takibi olan araştırmalar yapılması önerilmektedir.
- 19 September 2022
- Published by Ankara Dis Hekimleri Odasi in ADO Klinik Bilimler Dergisi
- Vol. 11 (3) , 215-219
Temporomandibuler Eklem Hastalıklarının Teşhisinde MRG Altın Standart Mıdır?
Amaç; Bu retrospektif çalışmanın amacı temporomandibular eklem bozukluğu (TMD) şikâyeti ile kliniğe gelen ve daha önceden manyetik rezonans görüntülemesi (MRG) olan hastalarda klinik bulgular ve MRG bulguları arasındaki ilişkiyi değerlendirmektir. Gereç ve yöntem; Temporomandibular eklem bozukluğu (TMD) şikayeti ile gelen ve MR bulguları ve klinik muayene bulguları kaydedilmiş 85 hasta değerlendirildi. TME, MRG ve klinik muayene bulguları, çene ağrısı, ağız açıklığında kısıtlanma şikayetleri ve MR isteminin hangi bölüm tarafından yapıldığı retrospektif olarak değerlendirildi. Veriler SPSS 19 ile analiz edildi. Sayısal veriler ortalama ± standart sapma şeklinde sunuldu. Kategorik verilerin karşılaştırılmasında ki-kare testi kullanıldı. P<0.05 istatistiksel olarak önemli kabul edildi. Bulgular; Bu çalışmada 85 hastanın MRG sonuçları ve klinik bulguları retrospektif olarak incelendi. 85 hastanın 71’inin (%83,5) klinik ve MRG Bulguları arasında korelasyon bulundu. 14 hastanın (%16,5) bulguları uyumsuz bulundu. Sonuç; Çalışmanın sonuçlarında klinik muayene bulguları ile MRG bulguları arasında yüksek uyumluluk olduğu saptanmıştır. Konu hakkında daha yüksek hasta sayısı ve daha uzun süreli takibi olan araştırmalar yapılması önerilmektedir.