Lénaïc Cuau
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Lénaïc Cuau has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Nabil Zemiti
University of Montpellier
4 shared publications - João Cavalcanti Santos
LIRMM, University of Montpellier, CNRS, Montpellier, France
2 shared publications - Philippe Poignet
LIRMM, Univ Montpellier, CNRS, Montpellier, France
2 shared publications M. Ohayon
LIRMM, University of Montpellier, CNRS, Montpellier, France
1 shared publication- Marie De Boutray
LIRMM, University of Montpellier, CNRS, Montpellier, France
1 shared publication - Marie de Boutray
Department of ENT, Neck Surgery and Maxillofacial Surgery, Gui de Chauliac University Hospital, Montpellier University, Montpellier, France
1 shared publication
Latest Publications
- 30 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (7) , 7262-7269
Non-Rigid Motion Compensation With Skin Deformation Prediction for in Situ Bioprinting
This paper introduces a novel method of non-rigid motion compensation for in situ bioprinting. Most bioprinting platforms use open-loop systems, but it raises concerns about patient safety and suboptimal wound coverage in case of patient motion. To handle these issues, our method integrates an RGB-D camera to manage orientation and to predict deformations, along with a laser telemeter to regulate deposited material thickness. The proposed approach has been evaluated on a moving silicone platform that deforms at 0.8 Hz with a 4 mm in-plane amplitude and a 20 mm elevation amplitude. Our method resulted in a wound coverage error of less than 1 %. Comparative analysis demonstrates a 73.0% enhancement in deforming path following compared to existing methods. Additionally, by predicting surface motion, the method enables more precise control of layer height, with an error inferior to 0.1 mm.
- 30 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (7) , 7262-7269
Non-Rigid Motion Compensation With Skin Deformation Prediction for in Situ Bioprinting
This paper introduces a novel method of non-rigid motion compensation for in situ bioprinting. Most bioprinting platforms use open-loop systems, but it raises concerns about patient safety and suboptimal wound coverage in case of patient motion. To handle these issues, our method integrates an RGB-D camera to manage orientation and to predict deformations, along with a laser telemeter to regulate deposited material thickness. The proposed approach has been evaluated on a moving silicone platform that deforms at 0.8 Hz with a 4 mm in-plane amplitude and a 20 mm elevation amplitude. Our method resulted in a wound coverage error of less than 1 %. Comparative analysis demonstrates a 73.0% enhancement in deforming path following compared to existing methods. Additionally, by predicting surface motion, the method enables more precise control of layer height, with an error inferior to 0.1 mm.
- 19 August 2023
- Published by Elsevier in International Journal of Oral and Maxillofacial Surgery
- Vol. 53 (4) , 343-346
Robot-guided osteotomy in fibula free flap mandibular reconstruction: a preclinical study
- 19 August 2023
- Published by Elsevier in International Journal of Oral and Maxillofacial Surgery
- Vol. 53 (4) , 343-346
Robot-guided osteotomy in fibula free flap mandibular reconstruction: a preclinical study
- 4 June 2023
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 18 (11) , 2073-2082
Contactless surface registration of featureless anatomy using structured light camera: application to fibula navigation in mandible reconstruction
Purpose Mandibular reconstruction using fibula free flap is a challenging surgical procedure. To assist osteotomies, computer-assisted surgery (CAS) can be used. Nevertheless, precise registration is required and often necessitates anchored markers that disturb the patient and clinical flow. This work proposes a new contactless surface-based method adapted to featureless anatomies such as fibula to achieve a fast, precise, and reproducible registration. Methods Preoperatively, a CT-scan of the patient is realized and osteotomies are virtually planned. During surgery, a structured light camera digitizes the fibula. The obtained intraoperative point cloud is coarsely registered with the preoperative model using 3 points defined in the CT-scan and located on the patient’s bone with a laser beam. Then, a fine registration is performed using an ICP algorithm. The registration accuracy was evaluated comparing the position of points engraved in a 3D-printed fibula with their position in the registered model and evaluating resulting osteotomies. Accuracy and execution time were compared to a conventional stylus-based registration method. The work was validated in vivo. Results The experiment performed on a 3D-printed model showed that execution time is equivalent to surface-based registration using a stylus, with a better accuracy (mean TRE of 0.9 mm vs 1.3 mm using stylus) and guarantee good osteotomies. The preliminary in vivo study proved the feasibility of the method. Conclusion The proposed contactless surface-based registration method using structured light camera gave promising results in terms of accuracy and execution speed and should be useful to implement CAS for mandibular reconstruction.
- 4 June 2023
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 18 (11) , 2073-2082
Contactless surface registration of featureless anatomy using structured light camera: application to fibula navigation in mandible reconstruction
Purpose Mandibular reconstruction using fibula free flap is a challenging surgical procedure. To assist osteotomies, computer-assisted surgery (CAS) can be used. Nevertheless, precise registration is required and often necessitates anchored markers that disturb the patient and clinical flow. This work proposes a new contactless surface-based method adapted to featureless anatomies such as fibula to achieve a fast, precise, and reproducible registration. Methods Preoperatively, a CT-scan of the patient is realized and osteotomies are virtually planned. During surgery, a structured light camera digitizes the fibula. The obtained intraoperative point cloud is coarsely registered with the preoperative model using 3 points defined in the CT-scan and located on the patient’s bone with a laser beam. Then, a fine registration is performed using an ICP algorithm. The registration accuracy was evaluated comparing the position of points engraved in a 3D-printed fibula with their position in the registered model and evaluating resulting osteotomies. Accuracy and execution time were compared to a conventional stylus-based registration method. The work was validated in vivo. Results The experiment performed on a 3D-printed model showed that execution time is equivalent to surface-based registration using a stylus, with a better accuracy (mean TRE of 0.9 mm vs 1.3 mm using stylus) and guarantee good osteotomies. The preliminary in vivo study proved the feasibility of the method. Conclusion The proposed contactless surface-based registration method using structured light camera gave promising results in terms of accuracy and execution speed and should be useful to implement CAS for mandibular reconstruction.
- 17 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 8 (4) , 2046-2053
Decoupled Model Predictive Control for Path Following on Complex Surfaces
The present letter proposes a predictive path following control (PPFC) that controls 5 degrees of freedom (DoFs) of the end-effector while the remaining (decoupled) translational DoF should be controlled by an external controller. This PPFC is particularly useful for the path following on surfaces with geometric uncertainties such that the external controller can be independently designed to manage the interaction between the tool and the surface. Therefore, the proposed strategy turns out to be a versatile control scheme that can be integrated with external controllers designed for applications such as robotic surface finishing, welding and 3D printing on complex surfaces. The corresponding optimal control problem (OCP) considers mainly the positioning and orientation errors, tangential velocity and control input amplitudes. The proposed PPFC is validated experimentally in the context of robotic 3D bio-printing. A 7-DoF redundant manipulator equipped with a distance sensor is used to handle a print head through the desired print path. The distance measurements are used by an external controller to correct the printed layer height. The obtained accuracy is consistent with the repeatability of the used manipulator and computation time is compatible with high frequency controllers.
- 17 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 8 (4) , 2046-2053
Decoupled Model Predictive Control for Path Following on Complex Surfaces
The present letter proposes a predictive path following control (PPFC) that controls 5 degrees of freedom (DoFs) of the end-effector while the remaining (decoupled) translational DoF should be controlled by an external controller. This PPFC is particularly useful for the path following on surfaces with geometric uncertainties such that the external controller can be independently designed to manage the interaction between the tool and the surface. Therefore, the proposed strategy turns out to be a versatile control scheme that can be integrated with external controllers designed for applications such as robotic surface finishing, welding and 3D printing on complex surfaces. The corresponding optimal control problem (OCP) considers mainly the positioning and orientation errors, tangential velocity and control input amplitudes. The proposed PPFC is validated experimentally in the context of robotic 3D bio-printing. A 7-DoF redundant manipulator equipped with a distance sensor is used to handle a print head through the desired print path. The distance measurements are used by an external controller to correct the printed layer height. The obtained accuracy is consistent with the repeatability of the used manipulator and computation time is compatible with high frequency controllers.