Eduarda Sabá Cordeiro de Oliveira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Eduarda Sabá Cordeiro de Oliveira has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Cintia Gomes
Department of Medicine, Federal University of Santa Maria, Brazil
2 shared publications - Marina Mordehachvili Burlá
Department of Medicine, Estacio de Sa Vista Carioca University, Rio de Janeiro, Brazil
2 shared publications - Rui-Min Diana Mao
Department of Surgery, University of Texas Medical Branch, Galveston, TX, USA
2 shared publications - Sergio Mazzola Poli de Figueiredo
Department of Surgery University of North Carolina Chapel Hill North Carolina USA
2 shared publications - Ana Carolina Rathsam Leite
Department of Oncology, Hospital Sírio-Libanês, Brasília, Distrito Federal, Brazil
1 shared publication - Claudiner Pereira de Oliveira
Unidade de Genética do Hospital de Apoio de Brasília, Secretaria de Saúde, Brasília 70684-831, DF, Brazil
1 shared publication
Latest Publications
- Open Access
TP53 p.R337H Germline Variant among Women at Risk of Hereditary Breast Cancer in a Public Health System of Midwest Brazil
Despite the high prevalence of TP53 pathogenic variants (PV) carriers in the South and Southeast regions of Brazil, germline genetic testing for hereditary breast cancer (HBC) is not available in the Brazilian public health system, and the prevalence of Li-Fraumeni syndrome (LFS) is not well established in other regions of Brazil. We assessed the occurrence of TP53 p.R337H carriers among women treated for breast cancer (BC) between January 2021 and January 2022 at public hospitals of Brasilia, DF, Brazil. A total of 180 patients who met at least one of the NCCN criteria for HBC underwent germline testing; 44.4% performed out-of-pocket germline multigene panel testing, and 55.6% were tested for the p.R337H variant by allelic discrimination PCR. The median age at BC diagnosis was 43.5 years, 93% had invasive ductal carcinoma, 50% had estrogen receptor-positive/HER2 negative tumors, and 41% and 11% were diagnosed respectively at stage III and IV. Two patients (1.11%) harbored the p.R337H variant, and cascade family testing identified 20 additional carriers. The TP53 p.R337H detection rate was lower than that reported in other studies from south/southeast Brazil. Nonetheless, identifying TP53 PV carriers through genetic testing in the Brazilian public health system could guide cancer treatment and prevention.
Open AccessTP53 p.R337H Germline Variant among Women at Risk of Hereditary Breast Cancer in a Public Health System of Midwest Brazil
Despite the high prevalence of TP53 pathogenic variants (PV) carriers in the South and Southeast regions of Brazil, germline genetic testing for hereditary breast cancer (HBC) is not available in the Brazilian public health system, and the prevalence of Li-Fraumeni syndrome (LFS) is not well established in other regions of Brazil. We assessed the occurrence of TP53 p.R337H carriers among women treated for breast cancer (BC) between January 2021 and January 2022 at public hospitals of Brasilia, DF, Brazil. A total of 180 patients who met at least one of the NCCN criteria for HBC underwent germline testing; 44.4% performed out-of-pocket germline multigene panel testing, and 55.6% were tested for the p.R337H variant by allelic discrimination PCR. The median age at BC diagnosis was 43.5 years, 93% had invasive ductal carcinoma, 50% had estrogen receptor-positive/HER2 negative tumors, and 41% and 11% were diagnosed respectively at stage III and IV. Two patients (1.11%) harbored the p.R337H variant, and cascade family testing identified 20 additional carriers. The TP53 p.R337H detection rate was lower than that reported in other studies from south/southeast Brazil. Nonetheless, identifying TP53 PV carriers through genetic testing in the Brazilian public health system could guide cancer treatment and prevention.
- 30 June 2023
- Published by Elsevier in The American Journal of Surgery
- Vol. 226 (3) , 385-392
Impact of sex on ventral hernia repair outcomes: A systematic review and meta-analysis
- 30 June 2023
- Published by Elsevier in The American Journal of Surgery
- Vol. 226 (3) , 385-392
Impact of sex on ventral hernia repair outcomes: A systematic review and meta-analysis
- 4 June 2023
- Published by Springer Nature in Hernia
- Vol. 27 (4) , 795-806
Management and outcomes of obturator hernias: a systematic review and meta-analysis
Purpose Obturator Hernia (OH) is a rare type of abdominal wall hernia. It usually occurs in elderly women with late symptomatic presentation, increasing mortality rates. Surgery is the standard of care for OH, and laparotomy with simple suture closure of the defect is commonly used. Given the rarity of this disease, large studies are lacking, and data to drive management are still limited. This systematic review and meta-analysis aimed to describe current surgical options for OHs, with a focus on comparing the effectiveness and safety of mesh use with primary repair. Methods PubMed, EMBASE, and Cochrane were searched for studies comparing mesh and non-mesh repair for OH. Postoperative outcomes were assessed by pooled analysis and meta-analysis. Statistical analysis was performed using RevMan 5.4. Results One thousand seven hundred and sixty studies were screened and sixty-seven were thoroughly reviewed. We included 13 observational studies with 351 patients surgically treated for OH with mesh or non-mesh repair. One hundred and twenty (34.2%) patients underwent mesh repair and two hundred and thirty-one (65.81%) underwent non-mesh repair. A total of 145 (41.3%) underwent bowel resection, with the majority having a non-mesh repair performed. Hernia recurrence was significantly higher in patients who underwent hernia repair without mesh (RR 0.31; 95% CI 0.11–0.94; p = 0.04). There were no differences in mortality (RR 0.64; 95% CI 0.25–1.62; p = 0.34; I2 = 0%) or complication rates (RR 0.59; 95% CI 0.28–1.25; p = 0.17; I2 = 50%) between both groups. Conclusion Mesh repair in OH was associated with lower recurrence rates without an increase in postoperative complications. While mesh in clean cases is more likely to offer benefits, an overall recommendation regarding its use in OH repair cannot be made due to potential bias across studies. Given that many OH patients are frail and present emergently, the decision to use mesh is complex and should consider the patient’s clinical status, comorbidities, and degree of intraoperative contamination.
- 4 June 2023
- Published by Springer Nature in Hernia
- Vol. 27 (4) , 795-806
Management and outcomes of obturator hernias: a systematic review and meta-analysis
Purpose Obturator Hernia (OH) is a rare type of abdominal wall hernia. It usually occurs in elderly women with late symptomatic presentation, increasing mortality rates. Surgery is the standard of care for OH, and laparotomy with simple suture closure of the defect is commonly used. Given the rarity of this disease, large studies are lacking, and data to drive management are still limited. This systematic review and meta-analysis aimed to describe current surgical options for OHs, with a focus on comparing the effectiveness and safety of mesh use with primary repair. Methods PubMed, EMBASE, and Cochrane were searched for studies comparing mesh and non-mesh repair for OH. Postoperative outcomes were assessed by pooled analysis and meta-analysis. Statistical analysis was performed using RevMan 5.4. Results One thousand seven hundred and sixty studies were screened and sixty-seven were thoroughly reviewed. We included 13 observational studies with 351 patients surgically treated for OH with mesh or non-mesh repair. One hundred and twenty (34.2%) patients underwent mesh repair and two hundred and thirty-one (65.81%) underwent non-mesh repair. A total of 145 (41.3%) underwent bowel resection, with the majority having a non-mesh repair performed. Hernia recurrence was significantly higher in patients who underwent hernia repair without mesh (RR 0.31; 95% CI 0.11–0.94; p = 0.04). There were no differences in mortality (RR 0.64; 95% CI 0.25–1.62; p = 0.34; I2 = 0%) or complication rates (RR 0.59; 95% CI 0.28–1.25; p = 0.17; I2 = 50%) between both groups. Conclusion Mesh repair in OH was associated with lower recurrence rates without an increase in postoperative complications. While mesh in clean cases is more likely to offer benefits, an overall recommendation regarding its use in OH repair cannot be made due to potential bias across studies. Given that many OH patients are frail and present emergently, the decision to use mesh is complex and should consider the patient’s clinical status, comorbidities, and degree of intraoperative contamination.