Yannan Pan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yannan Pan has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Jie Jiang
Peking University First Hospital
3 shared publications Jing Zhou
Department of Cardiology, Peking University First Hospital, Beijing, China
3 shared publications- Dong Zhao
Centre for Clinical and Epidemiologic Research, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart, Lung and Blood Vessel Diseases, National Clinical Research Centre for Cardiovascular Diseases , No. 2 Anzhen Road, Chaoyang District, Beijing 100029
2 shared publications - Fangfang Fan
Department of Cardiology, Peking University First Hospital, Beijing, China
2 shared publications Jianping Li
Department of Cardiology, Peking University First Hospital, Beijing, China
2 shared publicationsJun Liu
Department of Epidemiology, Beijing Anzhen Hospital Capital Medical University, Beijing Institute of Heart, Lung and Blood Vessel Diseases Beijing China
2 shared publications
Latest Publications
- Open Access
- 23 January 2025
- Published by SAGE Publications in Digital Health
- Vol. 11
Continuous atrial fibrillation monitoring using a wearable smartwatch: Using long-term Holter as reference
Background: Wearables satisfactorily detect atrial fibrillation (AF) longer than 1 hour. Our study aims to evaluate smartwatch performances for long-term AF monitoring, including AF with short durations. Methods: This prospective study enrolled AF patients from 2020 to 2023. Diagnostic efficacy of the Amazfit smartwatch, with AF-identifying algorithms from photoplethysmography (PPG) and single-lead electrocardiogram (ECG), was compared with a 7-day Holter. Primary analysis included smartwatch diagnostics to identify AF longer than 5 minutes. Secondary analyses evaluated smartwatch performances under different settings and compared AF burdens between the smartwatch and Holter. Results: The study analyzed 72 patients (48 males, mean age 65.4 ± 8.5) with 914 AF episodes lasting 834.7 hours, including 142 longer-than-5-minute AF episodes. Smartwatch recording time was 8927.6 hours. By individual, sensitivities and specificities of AF longer than 5 minutes were 100.0% and 83.7% for PPG and 89.7% and 67.4% for the ECG algorithm. Positive and negative predictive values were 94.9% and 99.9% for PPG and 77.6% and 99.8% for ECG. Optimal AF durations to be identified by PPG and ECG algorithms were 1.358 and 16.708 minutes. Smartwatch performances varied across AF durations and between day-time and night-time. Strong correlations (PPG: ρ = 0.877; ECG: ρ = 0.769) and excellent agreements (PPG: ICC = 0.976; ECG: ICC = 0.927) were found between AF burdens calculated from smartwatch and Holter. Conclusions: Compared with long-term Holter, the wearable smartwatch had satisfying qualitative and quantitative diagnostic performances for continuous AF monitoring. Susceptibility to false positives led to modest specificity. Smartwatch performances were affected by AF durations and time periods. Registration: ChiCTR2000040035.
- 23 January 2025
- Published by SAGE Publications in Digital Health
- Vol. 11
Open AccessContinuous atrial fibrillation monitoring using a wearable smartwatch: Using long-term Holter as reference
Background: Wearables satisfactorily detect atrial fibrillation (AF) longer than 1 hour. Our study aims to evaluate smartwatch performances for long-term AF monitoring, including AF with short durations. Methods: This prospective study enrolled AF patients from 2020 to 2023. Diagnostic efficacy of the Amazfit smartwatch, with AF-identifying algorithms from photoplethysmography (PPG) and single-lead electrocardiogram (ECG), was compared with a 7-day Holter. Primary analysis included smartwatch diagnostics to identify AF longer than 5 minutes. Secondary analyses evaluated smartwatch performances under different settings and compared AF burdens between the smartwatch and Holter. Results: The study analyzed 72 patients (48 males, mean age 65.4 ± 8.5) with 914 AF episodes lasting 834.7 hours, including 142 longer-than-5-minute AF episodes. Smartwatch recording time was 8927.6 hours. By individual, sensitivities and specificities of AF longer than 5 minutes were 100.0% and 83.7% for PPG and 89.7% and 67.4% for the ECG algorithm. Positive and negative predictive values were 94.9% and 99.9% for PPG and 77.6% and 99.8% for ECG. Optimal AF durations to be identified by PPG and ECG algorithms were 1.358 and 16.708 minutes. Smartwatch performances varied across AF durations and between day-time and night-time. Strong correlations (PPG: ρ = 0.877; ECG: ρ = 0.769) and excellent agreements (PPG: ICC = 0.976; ECG: ICC = 0.927) were found between AF burdens calculated from smartwatch and Holter. Conclusions: Compared with long-term Holter, the wearable smartwatch had satisfying qualitative and quantitative diagnostic performances for continuous AF monitoring. Susceptibility to false positives led to modest specificity. Smartwatch performances were affected by AF durations and time periods. Registration: ChiCTR2000040035.
- Open Access
- 1 October 2024
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 13 (19) , e033941
Prevalence, Characteristics, and Treatment Strategy of Different Types of Heart Failure in Patients With Nonvalvular Atrial Fibrillation
Background: Atrial fibrillation (AF) is the most common arrhythmia in patients with heart failure (HF). Epidemiological data regarding HF in patients with AF are lacking. We describe the epidemiology, clinical features, treatment strategies, and in‐hospital outcomes in patients with AF and HF. Methods and Results: Patients with HF and nonvalvular AF in the Improving Care for Cardiovascular Disease in China‐AF cohort from February 2015 to December 2019 were included. Patients were stratified by left ventricular ejection fraction into HF with reduced EF, HF with mildly reduced EF, and HF with preserved EF groups. The primary outcome was the occurrence of hospitalization for major adverse cardiovascular events, including death, cardiogenic shock, cardiac arrest, and stroke. Overall, 16 562 patients with AF and HF were included (mean age: 72.35±11.07 years; 46.1% female). HF with preserved EF (63.1%) accounted for the largest proportion, followed by HF with mildly reduced EF (19.0%) and HF with reduced EF (17.9%). Different HF subtypes in patients with AF had unique baseline demographic and clinical characteristics after multinomial logistic regression analysis. Compared with the HF with preserved EF group, hospitalization for major adverse cardiovascular events was increased in the HF with mildly reduced EF group (odds ratio=1.55 [95% CI, 1.18–2.03]) and HF with reduced EF group (odds ratio 1.60 [95% CI, 1.21–2.13]) after adjusting for confounders. Conclusions: In this large Chinese AF registry, the distribution of HF differed from the non‐AF population. Patients with AF with different types of HF have unique demographic and clinical characteristics. Occurrence rates of in‐hospital outcomes were higher in patients with HF with mildly reduced EF and patients with HF with reduced EF compared with the HF with preserved EF group. Registration: URL: http://www.clinicaltrials.gov ; Unique identifier: NCT02309398.
- 1 October 2024
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 13 (19) , e033941
Open AccessPrevalence, Characteristics, and Treatment Strategy of Different Types of Heart Failure in Patients With Nonvalvular Atrial Fibrillation
Background: Atrial fibrillation (AF) is the most common arrhythmia in patients with heart failure (HF). Epidemiological data regarding HF in patients with AF are lacking. We describe the epidemiology, clinical features, treatment strategies, and in‐hospital outcomes in patients with AF and HF. Methods and Results: Patients with HF and nonvalvular AF in the Improving Care for Cardiovascular Disease in China‐AF cohort from February 2015 to December 2019 were included. Patients were stratified by left ventricular ejection fraction into HF with reduced EF, HF with mildly reduced EF, and HF with preserved EF groups. The primary outcome was the occurrence of hospitalization for major adverse cardiovascular events, including death, cardiogenic shock, cardiac arrest, and stroke. Overall, 16 562 patients with AF and HF were included (mean age: 72.35±11.07 years; 46.1% female). HF with preserved EF (63.1%) accounted for the largest proportion, followed by HF with mildly reduced EF (19.0%) and HF with reduced EF (17.9%). Different HF subtypes in patients with AF had unique baseline demographic and clinical characteristics after multinomial logistic regression analysis. Compared with the HF with preserved EF group, hospitalization for major adverse cardiovascular events was increased in the HF with mildly reduced EF group (odds ratio=1.55 [95% CI, 1.18–2.03]) and HF with reduced EF group (odds ratio 1.60 [95% CI, 1.21–2.13]) after adjusting for confounders. Conclusions: In this large Chinese AF registry, the distribution of HF differed from the non‐AF population. Patients with AF with different types of HF have unique demographic and clinical characteristics. Occurrence rates of in‐hospital outcomes were higher in patients with HF with mildly reduced EF and patients with HF with reduced EF compared with the HF with preserved EF group. Registration: URL: http://www.clinicaltrials.gov ; Unique identifier: NCT02309398.
- Open Access
- 1 July 2024
- Published by Taylor & Francis in Infection and Drug Resistance
- Vol. ume 17, 2957-2964
Infective Endocarditis Caused by Streptococcus Sinensis in a Patient with Bioprosthetic Aortic Valve: A Case Report and Literature Review
Background: Infective endocarditis caused by Streptococcus sinensis is exceedingly rare, with only limited cases reported. Here, we present the first documented case of prosthetic valve endocarditis attributed to Streptococcus sinensis. Case Presentation: A 40-year-old Chinese female was admitted with a 45-day history of intermittent fever. The presumed diagnosis was a pulmonary infection and antibiotic therapies failed to alleviate her symptoms. On admission, infective endocarditis was suspected, considering the history of aortic valve replacement and recent dental procedure without prophylactic antibiotics. Transesophageal echocardiography disclosed a 3-millimeter vegetation in the prosthetic aortic valve, and metagenomic next-generation sequencing and mass spectrometry identified Streptococcus sinensis. The patient was diagnosed with infective endocarditis. Antibiotic treatments resulted in temporary clinical improvements, although fluctuations in temperature and inflammatory markers led to multiple attempts at antibiotic therapies. At last, the patient underwent an elective aortic valve replacement with a favorable prognosis. Conclusion: In this case, we demonstrated prosthetic valve endocarditis caused by Streptococcus sinensis, which is an extremely rare pathogen. All reported endocarditis cases caused by Streptococcus sinensis were reviewed and summarized. Most of these patients had rheumatic heart diseases or congenital heart diseases. Antibiotic prophylaxis is important for high-risk procedures. Timely identification of the bacterium is crucial for diagnosis and treatment. Overall, infective endocarditis caused by this bacterium had a good prognosis.
- 1 July 2024
- Published by Taylor & Francis in Infection and Drug Resistance
- Vol. ume 17, 2957-2964
Open AccessInfective Endocarditis Caused by Streptococcus Sinensis in a Patient with Bioprosthetic Aortic Valve: A Case Report and Literature Review
Background: Infective endocarditis caused by Streptococcus sinensis is exceedingly rare, with only limited cases reported. Here, we present the first documented case of prosthetic valve endocarditis attributed to Streptococcus sinensis. Case Presentation: A 40-year-old Chinese female was admitted with a 45-day history of intermittent fever. The presumed diagnosis was a pulmonary infection and antibiotic therapies failed to alleviate her symptoms. On admission, infective endocarditis was suspected, considering the history of aortic valve replacement and recent dental procedure without prophylactic antibiotics. Transesophageal echocardiography disclosed a 3-millimeter vegetation in the prosthetic aortic valve, and metagenomic next-generation sequencing and mass spectrometry identified Streptococcus sinensis. The patient was diagnosed with infective endocarditis. Antibiotic treatments resulted in temporary clinical improvements, although fluctuations in temperature and inflammatory markers led to multiple attempts at antibiotic therapies. At last, the patient underwent an elective aortic valve replacement with a favorable prognosis. Conclusion: In this case, we demonstrated prosthetic valve endocarditis caused by Streptococcus sinensis, which is an extremely rare pathogen. All reported endocarditis cases caused by Streptococcus sinensis were reviewed and summarized. Most of these patients had rheumatic heart diseases or congenital heart diseases. Antibiotic prophylaxis is important for high-risk procedures. Timely identification of the bacterium is crucial for diagnosis and treatment. Overall, infective endocarditis caused by this bacterium had a good prognosis.
- Open Access
In-hospital therapies and determinants of treatment strategy selection in patients with atrial fibrillation and left ventricular systolic dysfunction in China: a retrospective study based on the Improving Care for Cardiovascular Disease in China-Atrial Fibrillation (CCC-AF) project, 2015–2019
Objectives: The optimal treatment strategy remains debatable in patients with atrial fibrillation (AF) and heart failure. Our objectives were to summarise in-hospital therapies and determine factors associated with treatment strategy selections. Design: A retrospective study analysing the Improving Care for Cardiovascular Disease in China-Atrial Fibrillation (CCC-AF) project from 2015 to 2019. Setting: The CCC-AF project included patients from 151 tertiary and 85 secondary hospitals across 30 provinces in China. Participants: Patients with AF and left ventricular systolic dysfunction (LVSD, defined as left ventricular ejection fractionp trend=0.175). Catheter ablation was used in 5.5% of patients, increasing from 3.3% in 2015 to 6.6% in 2019 ( p trend<0.001). Factors negatively associated with rhythm control included increased age (OR 0.973, 95% CI 0.967 to 0.980), valvular AF (OR 0.618, 95% CI 0.419 to 0.911), AF types (persistent: OR 0.546, 95% CI 0.462 to 0.645; long-standing persistent: OR 0.298, 95% CI 0.240 to 0.368), larger left atrial diameters (OR 0.966, 95% CI 0.957 to 0.976) and higher Charlson Comorbidity Index scores (CCI 1–2: OR 0.630, 95% CI 0.529 to 0.750; CCI≥3: OR 0.551, 95% CI 0.390 to 0.778). Higher platelet counts (OR 1.025, 95% CI 1.013 to 1.037) and prior rhythm control attempts (electrical cardioversion: OR 4.483, 95% CI 2.369 to 8.483; catheter ablation: OR 4.957, 95% CI 3.072 to 7.997) were positively associated with rhythm control strategies. Conclusion: In China, non-rhythm control strategy remained the dominant choice in patients with AF and LVSD. Age, AF types, prior treatments, left atrial diameters, platelet counts and comorbidities were major determinants of treatment strategies. Guideline-adherent therapies should be further promoted. Study registration number: NCT02309398 .
Open AccessIn-hospital therapies and determinants of treatment strategy selection in patients with atrial fibrillation and left ventricular systolic dysfunction in China: a retrospective study based on the Improving Care for Cardiovascular Disease in China-Atrial Fibrillation (CCC-AF) project, 2015–2019
Objectives: The optimal treatment strategy remains debatable in patients with atrial fibrillation (AF) and heart failure. Our objectives were to summarise in-hospital therapies and determine factors associated with treatment strategy selections. Design: A retrospective study analysing the Improving Care for Cardiovascular Disease in China-Atrial Fibrillation (CCC-AF) project from 2015 to 2019. Setting: The CCC-AF project included patients from 151 tertiary and 85 secondary hospitals across 30 provinces in China. Participants: Patients with AF and left ventricular systolic dysfunction (LVSD, defined as left ventricular ejection fractionp trend=0.175). Catheter ablation was used in 5.5% of patients, increasing from 3.3% in 2015 to 6.6% in 2019 ( p trend<0.001). Factors negatively associated with rhythm control included increased age (OR 0.973, 95% CI 0.967 to 0.980), valvular AF (OR 0.618, 95% CI 0.419 to 0.911), AF types (persistent: OR 0.546, 95% CI 0.462 to 0.645; long-standing persistent: OR 0.298, 95% CI 0.240 to 0.368), larger left atrial diameters (OR 0.966, 95% CI 0.957 to 0.976) and higher Charlson Comorbidity Index scores (CCI 1–2: OR 0.630, 95% CI 0.529 to 0.750; CCI≥3: OR 0.551, 95% CI 0.390 to 0.778). Higher platelet counts (OR 1.025, 95% CI 1.013 to 1.037) and prior rhythm control attempts (electrical cardioversion: OR 4.483, 95% CI 2.369 to 8.483; catheter ablation: OR 4.957, 95% CI 3.072 to 7.997) were positively associated with rhythm control strategies. Conclusion: In China, non-rhythm control strategy remained the dominant choice in patients with AF and LVSD. Age, AF types, prior treatments, left atrial diameters, platelet counts and comorbidities were major determinants of treatment strategies. Guideline-adherent therapies should be further promoted. Study registration number: NCT02309398 .