NPNasful Huda Prince

Nasful Huda Prince

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nasful Huda Prince has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Aberration-free Volumetric Imaging via Axial Scanning in Lattice Light-sheet Microscope

    by Md. Nasful Huda Prince, Wishwa Herath, Rachel Grattan, Shayna Lucero, Muthubharathi Balasubramanian, Keith Lidke, Olga Ponomarova, Diane Lidke, Tonmoy Chakraborty

    The lattice light-sheet microscope (LLSM) has become increasingly popular for its ability to provide gentle excitation, rapid high-resolution imaging, and structured illumination to achieve super-resolution. Despite numerous refinements over the past decade, volumetric imaging with LLSM still relies on either translating the specimen through the light-sheet or synchronously scanning the detection objective, both of which introduce vibrations into the sample media and can lead to errors in intracellular activity analysis, long-term imaging, and imaging speed. In addition, current implementations require image deskewing, adding a significant computational burden due to bottom-mounted sample geometries. Here, we present a simple, compact, and lossless optical design that enables volumetric imaging with LLSM across an axial depth of 110 μm without moving the specimen or the objective, while preserving diffraction-limited imaging performance. This design also eliminates the need for computational deskewing. We experimentally validated the performance of our system by imaging HeLa cells with multiple targets and live adult C. elegans containing embryos in situ , demonstrating its capability to achieve super-resolved imaging at the organismal scale.

  • Reflected inline detection in epi-oblique plane microscopy

    by Md. Nasful Huda Prince, Wishwa Herath, Balasubramanian Chellammal Muthubharathi, Nikhil Sain, Chitra Shaji, Md Rafiqul Islam Rupam, Aadil Qadir Bhat, Adil R. Wani, Mubarak Hussain Syed, Tae-Hyung Kim, et al.

    Epi-oblique illumination selective plane microscopy (OPM) facilitates open-top, straightforward sample mounting, enabling high-resolution, high-speed imaging without perturbing biological specimens. However, current OPM systems typically require three separate microscopes equipped with specialized objectives. This configuration leads to complex and costly setups, significant long-term drift during imaging, reduced numerical aperture, and limited flexibility in adjusting the illumination tilt angle. We introduce Reflected Inline Detection in Epi-Oblique Plane Microscopy (RIDE-OPM), a simplified, and cost-effective design that removes the necessity for a separate inline tertiary microscope and specialized objectives. Our tilt-angle-independent approach leverages the maximum NA of standard objectives, ensuring optimal illumination across the entire field of view without compromising imaging speed or quality, while significantly reducing long-term system drift. The compact and stable RIDE-OPM platform demonstrates robust, unsupervised long-term imaging capabilities. We validated this performance by successfully imaging various biological specimens, including C. elegans , Drosophila fly brain, human and mouse epithelial cells, and live E. coli , underscoring its suitability for advanced long-term biological imaging applications.


  • Open Access

    Reflected Inline Detection in Epi Oblique Plane Microscopy

    by Nasful Huda Prince, Balasubramanian Chellammal Muthubharathi, Wishwa Herath, Nikhil Sain, Rafiqul Islam Rupam, Aadil Qadir Bhat, Adil R. Wani, Mubarak Hussain Syed, Tae-Hyung Kim, Mark C. Walker, et al.

    Epi oblique illumination selective plane microscopy (OPM) facilitates open-top, straightforward sample mounting, enabling high-resolution and high-speed imaging without perturbing biological specimens. However, current OPM systems typically require three separate microscopes equipped with specialized objectives. This configuration leads to complex and costly setups, significant long-term drift during imaging, reduced numerical aperture, and limited flexibility in adjusting the illumination tilt angle. We introduce Reflected Inline Detection in Epi-Oblique Plane Microscopy (RIDE-OPM), a novel, simplified, and cost-effective design that removes the necessity for a separate inline tertiary microscope and specialized objectives. Our tilt-angle-independent approach leverages the maximum NA of standard objectives, ensuring optimal illumination across the entire field of view without compromising imaging speed or quality, while significantly reducing long-term system drift. The compact and stable RIDE-OPM platform demonstrates robust, unsupervised long-term imaging capabilities. We validated this performance by successfully imaging various biological specimens, including C. elegans , Drosophila fly brain, human and mouse epithelial cells, and live E. coli , underscoring its suitability for advanced long-term biological imaging applications.

  • Open Access

    Remote refocusing for multi-scale imaging

    by Nasful Huda Prince, Nikhil Sain, Tonmoy Chakraborty

    SignificanceThe technique of remote focusing (RF) has attracted considerable attention among microscopists due to its ability to quickly adjust focus across different planes, thus facilitating quicker volumetric imaging. However, the difficulty in changing objectives to align with a matching objective in a remote setting while upholding key requirements remains a challenge.AimWe aim to propose a customized yet straightforward technique to align multiple objectives with a remote objective, employing an identical set of optical elements to ensure meeting the criteria of remote focusing.ApproachWe propose a simple optical approach for aligning multiple objectives with a singular remote objective to achieve a perfect imaging system. This method utilizes readily accessible, commercial optical components to meet the fundamental requirements of remote focusing.ResultsOur experimental observations indicate that the proposed RF technique offers at least comparable, if not superior, performance over a significant axial depth compared with the conventional RF technique based on commercial lenses while offering the flexibility to switch the objective for multi-scale imaging.ConclusionsThe proposed technique addresses various microscopy challenges, particularly in the realm of multi-resolution imaging. We have experimentally demonstrated the efficacy of this technique by capturing images of focal volumes generated by two distinct objectives in a water medium.


  • Open Access

    Signal improved ultra-fast light-sheet microscope for large tissue imaging

    by Nasful Huda Prince, Benjamin Garcia, Cory Henn, Yating Yi, Etsuo A. Susaki, Yuki Watakabe, Tomomi Nemoto, Keith A. Lidke, Hu Zhao, Irene Salinas Remiro, et al.

    Axially swept light-sheet microscope in conjunction with tissue clearing enables three-dimensional morphological investigation of millimeter-scaled tissues at isotropic sub-micron resolution. However, these microscopes suffer from low detection signal and slow imaging speed. Here we report a simple and efficient imaging platform that employs precise control of two fixed distant light-sheet foci for axial sweeping. This enables full field of view imaging at 40 frames per second, a four-fold improvement over the current state-of-the-art. In addition, in a particular frame rate, our method doubles the signal compared to the existing techniques. To augment the overall imaging performance, we also developed a deep learning based tissue information classifier that enables faster determination of tissue boundary. We demonstrated the performance of our imaging platform on various cleared tissue samples and delineated its robustness over a wide range of clearing protocols.


  • Open Access

    Signal Improved ultra-Fast Light-sheet Microscope (SIFT) for large tissue imaging

    by Nasful Huda Prince, Benjamin Garcia, Cory Henn, Yating Yi, Etsuo A. Susaki, Yuki Watakabe, Tomomi Nemoto, Keith A Lidke, Hu Zhao, Irene Salinas Remiro, et al.

    Light-sheet fluorescence microscopy (LSFM) in conjunction with tissue clearing techniques enables morphological investigation of large tissues faster and with excellent optical sectioning. Recently, cleared tissue axially swept light-sheet microscope (ctASLM) demonstrated three-dimensional isotropic resolution in millimeter-scaled tissues. But ASLM based microscopes suffer from low detection signal and slow imaging speed. Here we report a simple and efficient imaging platform that employs precise control of two fixed distant light-sheet foci to carry out ASLM. This allowed us to carry out full field of view (FOV) imaging at 40 frames per second (fps) which is a four-fold improvement compared to the current state-of-the-art. In addition, in a particular frame rate, our method doubles the signal compared to the current ASLM technique. To augment the overall imaging performance, we also developed a deep learning based tissue information classifier that enables faster determination of tissue boundary. We demonstrated the performance of our imaging platform on various cleared tissue samples and demonstrated its robustness over a wide range of clearing protocols.


  • Open Access

    Axial scanning of dual focus to improve light sheet microscopy

    by Hassan Dibaji, Nasful Huda Prince, Yating Yi, Hu Zhao, Tonmoy Chakraborty

    Axially swept light sheet microscopy (ASLM) is an emerging technique that enables isotropic, subcellular resolution imaging with high optical sectioning capability over a large field-of-view (FOV). Due to its versatility across a broad range of immersion media, it has been utilized to image specimens that may range from live cells to intact chemically cleared organs. However, because of its design, the performance of ASLM-based microscopes is impeded by a low detection signal and the maximum achievable frame-rate for full FOV imaging. Here we present a new optical concept that pushes the limits of ASLM further by scanning two staggered light sheets and simultaneously synchronizing the rolling shutter of a scientific camera. For a particular peak-illumination-intensity, this idea can make ASLMs image twice as fast without compromising the detection signal. Alternately, for a particular frame rate our method doubles the detection signal without requiring to double the peak-illumination-power, thereby offering a gentler illumination scheme compared to tradition single-focus ASLM. We demonstrate the performance of our instrument by imaging fluorescent beads and a PEGASOS cleared-tissue mouse brain.