Po Xu
Po Xu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Yiming Wang
Research Center, Ginlong Technologies Co., Ltd., Ningbo 315712, China
4 shared publications - Wenping Zhang
School of Electrical and Information Engineering, Tianjin University, Tianjin, China
3 shared publications - Baosong Liu
Research Center, Ginlong Technologies Co., Ltd., Ningbo 315712, China
2 shared publications - Donghui Li
School of Electrical and Information Engineering, Tianjin University, Tianjin 300072, China
2 shared publications - Ke Ma
Key Laboratory of Control of Power Transmission and Conversion, Ministry of Education, Shanghai Jiao Tong University, Shanghai, China
1 shared publication - Na Zhang
Ginlong Technology Co., Ltd., Ningbo 315712, China
1 shared publication
Latest Publications
- Open Access
- 1 January 2025
- Published by SCIE Publishing Limited in Smart Energy System Research
- Vol. 1 (2) , 10007
Review of Ground Insulation Resistance Detection Methods for Photovoltaic (PV) Systems
SCIEPublish is an international open-access journal publishing service provider run by SCIE Publishing Limited, dedicated to supporting and inspiring scientists or institutions/societies who aspire to publish high-quality journals.
- 1 January 2025
- Published by SCIE Publishing Limited in Smart Energy System Research
- Vol. 1 (2) , 10007
Open AccessReview of Ground Insulation Resistance Detection Methods for Photovoltaic (PV) Systems
SCIEPublish is an international open-access journal publishing service provider run by SCIE Publishing Limited, dedicated to supporting and inspiring scientists or institutions/societies who aspire to publish high-quality journals.
- Open Access
A Current Control Method for Grid-Connected Inverters
It is simple to implement conventional current control with a proportional integral (PI) controller. However, system stability and dynamic performance are not perfect, particularly when operating under unfavorable conditions. In this paper, an improved control method is proposed by introducing a compensation unit. The compensation unit can effectively compensate the system’s phase around the crossover frequency, greatly enhancing the system’s phase margin and stability. It is also capable of handling weak-grid conditions. In this paper, the concept of the proposed compensation unit is explained first. Then, the corresponding mathematical model for the current control loop is built, and system bode diagrams for the conventional and proposed methods are compared. Furthermore, the effect of the parameters for the compensation unit is investigated, and an optimization method is proposed to determine optimal parameters. In addition, to handle weak-grid conditions, the proposed scheme is expanded by including the compensation unit in the grid’s feed-forward loop. Finally, an experimental platform is constructed, and the experimental results are presented to validate the proposed method.
Open AccessA Current Control Method for Grid-Connected Inverters
It is simple to implement conventional current control with a proportional integral (PI) controller. However, system stability and dynamic performance are not perfect, particularly when operating under unfavorable conditions. In this paper, an improved control method is proposed by introducing a compensation unit. The compensation unit can effectively compensate the system’s phase around the crossover frequency, greatly enhancing the system’s phase margin and stability. It is also capable of handling weak-grid conditions. In this paper, the concept of the proposed compensation unit is explained first. Then, the corresponding mathematical model for the current control loop is built, and system bode diagrams for the conventional and proposed methods are compared. Furthermore, the effect of the parameters for the compensation unit is investigated, and an optimization method is proposed to determine optimal parameters. In addition, to handle weak-grid conditions, the proposed scheme is expanded by including the compensation unit in the grid’s feed-forward loop. Finally, an experimental platform is constructed, and the experimental results are presented to validate the proposed method.
- Open Access
Performance Analysis and Comprehensive Evaluation of Solar Organic Rankine Cycle Combined with Transcritical CO2 Refrigeration Cycle
In order to achieve efficient utilization of solar energy resources, this study combines the trans-critical organic Rankine cycle (ORC) power cycle (TORC) with the trans-critical CO2 refrigeration cycle (TCO2). Additionally, a comprehensive three-level index decision evaluation system is developed based on system safety and environmental protection, thermodynamics, and techno-economic performance. The evaluation focuses on typical medium- and high-temperature solar energy applications and considers six organic working gases. The evaluation results demonstrate that the R600 + CO2 solution outperformed the others. This solution achieved a maximum net output power (Pnet) of 1531.31 kW and 2306.43 kW, a maximum coefficient of performance (COP) of 3.16, a predicted payback period of 2.651 years and 2.033 years, and a benefit–investment ratio of 4.533 and 5.773.
Open AccessPerformance Analysis and Comprehensive Evaluation of Solar Organic Rankine Cycle Combined with Transcritical CO2 Refrigeration Cycle
In order to achieve efficient utilization of solar energy resources, this study combines the trans-critical organic Rankine cycle (ORC) power cycle (TORC) with the trans-critical CO2 refrigeration cycle (TCO2). Additionally, a comprehensive three-level index decision evaluation system is developed based on system safety and environmental protection, thermodynamics, and techno-economic performance. The evaluation focuses on typical medium- and high-temperature solar energy applications and considers six organic working gases. The evaluation results demonstrate that the R600 + CO2 solution outperformed the others. This solution achieved a maximum net output power (Pnet) of 1531.31 kW and 2306.43 kW, a maximum coefficient of performance (COP) of 3.16, a predicted payback period of 2.651 years and 2.033 years, and a benefit–investment ratio of 4.533 and 5.773.
- Open Access
Evaluation and Improvement of Backup Capacity for Household Electric Vehicle Uninterruptible Power Supply (EV-UPS) Systems
The use of electric vehicles (EVs) for household uninterruptible power supplies (UPSs), particularly in rural areas, can greatly improve household power reliability. However, because EVs are mobile, the evaluation of backup capacity for EV-UPS systems is completely different when compared to traditional UPSs. As a result, the focus of this paper is on the evaluation and improvement of backup capacity for EV-UPS systems. The architectures for EV-UPS systems are presented first. The methodology for calculating backup capacity for EV-UPS systems is then presented, followed by four detailed cases based on different grid failure times. Furthermore, the impact of system operating parameters on backup capacity, such as different load power, EV mobility pattern parameters, and grid outage durations, is investigated. The results of backup capacity in cases of different operating parameters are detailed using an EV mobility model. An improved strategy for increasing backup capacity is proposed, in which more backup energy can be released during a power outage. Meanwhile, the next trip requirement is unaffected. The backup capacity with the improved strategy is then calculated and compared to the results with the traditional strategy. Finally, a 5 kW EV-UPS experimental platform is constructed, and the experimental results are presented to validate the proposed method.
Open AccessEvaluation and Improvement of Backup Capacity for Household Electric Vehicle Uninterruptible Power Supply (EV-UPS) Systems
The use of electric vehicles (EVs) for household uninterruptible power supplies (UPSs), particularly in rural areas, can greatly improve household power reliability. However, because EVs are mobile, the evaluation of backup capacity for EV-UPS systems is completely different when compared to traditional UPSs. As a result, the focus of this paper is on the evaluation and improvement of backup capacity for EV-UPS systems. The architectures for EV-UPS systems are presented first. The methodology for calculating backup capacity for EV-UPS systems is then presented, followed by four detailed cases based on different grid failure times. Furthermore, the impact of system operating parameters on backup capacity, such as different load power, EV mobility pattern parameters, and grid outage durations, is investigated. The results of backup capacity in cases of different operating parameters are detailed using an EV mobility model. An improved strategy for increasing backup capacity is proposed, in which more backup energy can be released during a power outage. Meanwhile, the next trip requirement is unaffected. The backup capacity with the improved strategy is then calculated and compared to the results with the traditional strategy. Finally, a 5 kW EV-UPS experimental platform is constructed, and the experimental results are presented to validate the proposed method.