Thomas Scholbach
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Thomas Scholbach has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- An-Hang Yang
Department of Pathology and Laboratory Medicine, Taipei Veterans General Hospital, Taipei, Taiwan
1 shared publication - Berthold Huppertz
Division of Cell Biology, Histology and Embryology, Gottfried Schatz Research Center, Medical University of Graz, 8010 Graz, Austria
1 shared publication C. Vogel
1 shared publication- Che-Chuan Loong
Division of Transplantation Surgery, Department of Surgery, Taipei Veterans General Hospital, 201 Shih-Pai Road, Sec. 2, Taipei, 11217, Taiwan.
1 shared publication D. Weitzel
Fachbereich Kinderheilkunde und Jugendmedizin, Deutsche Klinik für Diagnostik, Aukamm Allee 33, 65191 Wiesbaden, Germany
1 shared publication- Hsin-Kai Wang
Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan; School of Medicine, National Yang-Ming University, Taipei, Taiwan
1 shared publication
Latest Publications
- 20 February 2014
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 35 (05) , 445-450
Color Doppler Sonographic Dynamic Tissue Perfusion Measurement Demonstrates Significantly Reduced Cortical Perfusion in Children with Diabetes Mellitus Type 1 without Microalbuminuria and Apparently Healthy Kidneys
Motivation: With respect to the devastating consequences of the increasing prevalence of diabetes mellitus, the main reason for end stage renal disease and dialysis in industrialized countries, and the very limited diagnostic and therapeutic possibilities to predict, monitor and prevent diabetic nephropathy (DN), new concepts for early recognition and quantification of the prevailing microvascular changes in DN are urgently needed. Materials and Methods: We present the first study of renal cortical tissue perfusion measurement by means of standardized color Doppler sonographic videos evaluated with the PixelFlux software 1 for Dynamic Tissue Perfusion Measurement (DTPM) in 92 patients with DM1 without MA compared to 71 healthy probands. Results: DTPM reveals a highly significant diminution of cortical perfusion in patients with DM1 compared to healthy probands by 31 %, most pronounced in the distal hemicortex (reduction by 50 %) compared to 21 % within the proximal hemicortex. Conclusion: Thus, DTPM offers a novel means of numerically describing the state of the renal microvasculature in DM in a patient-friendly, non-invasive, non-ionizing manner. Motivation: Die schwerwiegenden Folgen der zunehmenden Prävalenz des Diabetes mellitus, der Hauptursache terminalen Nierenversagens in den Industrieländern und die noch sehr begrenzten Möglichkeiten, die diabetische Nephropathie (DN) vorherzusehen, zu überwachen und zu verhindern verlangen nach neuen Konzepten der Früherkennung und Quantifizierung mikrovaskulärer Veränderungen. Material und Methoden: Wir legen die erste Untersuchung zur standardisierten dynamischen farbdopplersonografischen Gewebsperfusionsmessung (DTPM) des renalen Kortex mit der PixelFlux-Software bei 92 Kindern mit Diabetes mellitus Typ 1 (DM1) ohne Mikroalbuminurie (MA) im Vergleich zu 71 gesunden Probanden vor. Ergebnisse: Dabei fanden wir eine signifikante Perfusionsminderung bei Patienten mit DM1 im Vergleich zu Gesunden um 31 %. Sie war im distalen Hemikortex mit 50 % stärker als im proximalen Hemikortex (21 %) ausgeprägt. Schlussfolgerung: Mit der DTPM kann die Schädigung kleinster renalen Gefäße bei DM patientenschonend quantifiziert werden.
- 20 February 2014
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 35 (05) , 445-450
Color Doppler Sonographic Dynamic Tissue Perfusion Measurement Demonstrates Significantly Reduced Cortical Perfusion in Children with Diabetes Mellitus Type 1 without Microalbuminuria and Apparently Healthy Kidneys
Motivation: With respect to the devastating consequences of the increasing prevalence of diabetes mellitus, the main reason for end stage renal disease and dialysis in industrialized countries, and the very limited diagnostic and therapeutic possibilities to predict, monitor and prevent diabetic nephropathy (DN), new concepts for early recognition and quantification of the prevailing microvascular changes in DN are urgently needed. Materials and Methods: We present the first study of renal cortical tissue perfusion measurement by means of standardized color Doppler sonographic videos evaluated with the PixelFlux software 1 for Dynamic Tissue Perfusion Measurement (DTPM) in 92 patients with DM1 without MA compared to 71 healthy probands. Results: DTPM reveals a highly significant diminution of cortical perfusion in patients with DM1 compared to healthy probands by 31 %, most pronounced in the distal hemicortex (reduction by 50 %) compared to 21 % within the proximal hemicortex. Conclusion: Thus, DTPM offers a novel means of numerically describing the state of the renal microvasculature in DM in a patient-friendly, non-invasive, non-ionizing manner. Motivation: Die schwerwiegenden Folgen der zunehmenden Prävalenz des Diabetes mellitus, der Hauptursache terminalen Nierenversagens in den Industrieländern und die noch sehr begrenzten Möglichkeiten, die diabetische Nephropathie (DN) vorherzusehen, zu überwachen und zu verhindern verlangen nach neuen Konzepten der Früherkennung und Quantifizierung mikrovaskulärer Veränderungen. Material und Methoden: Wir legen die erste Untersuchung zur standardisierten dynamischen farbdopplersonografischen Gewebsperfusionsmessung (DTPM) des renalen Kortex mit der PixelFlux-Software bei 92 Kindern mit Diabetes mellitus Typ 1 (DM1) ohne Mikroalbuminurie (MA) im Vergleich zu 71 gesunden Probanden vor. Ergebnisse: Dabei fanden wir eine signifikante Perfusionsminderung bei Patienten mit DM1 im Vergleich zu Gesunden um 31 %. Sie war im distalen Hemikortex mit 50 % stärker als im proximalen Hemikortex (21 %) ausgeprägt. Schlussfolgerung: Mit der DTPM kann die Schädigung kleinster renalen Gefäße bei DM patientenschonend quantifiziert werden.
- Open Access
- 11 July 2013
- Published by Springer Nature in BMC Nephrology
- Vol. 14 (1) , 143
Correlation of histopathologic and dynamic tissue perfusion measurement findings in transplanted kidneys
Cortical perfusion of the renal transplant can be non-invasively assessed by color Doppler ultrasonography. We performed the Dynamic Tissue Perfusion Measurement (DTPM) of the transplant’s renal cortex using color Doppler ultrasonography (PixelFlux technique), and compared the results with the histopathological findings of transplant biopsies. Ninety-six DTPM studies of the renal transplant’s cortex followed by transplant biopsies were performed in 78 patients. The cortical perfusion data were compared with the parameter of peritubular inflammatory cell accumulation (PTC 0 to 3) based on Banff-classification system. A significant decrease of cortical perfusion could be demonstrated as the inflammatory cells accumulation in peritubular capillaries increased. Increasing peritubulitis caused a perfusion loss from central to distal layers of 79% in PTC 0, of 85% in PTC 1, of 94% in PTC 2, and of 94% in PTC 3. Furthermore, the perfusion loss due to peritubular inflammation was more prominent in the distal cortical layer. The extent of perfusion decline with increasing peritubulitis (from PTC 0 to PTC 3) was 64% in proximal 20% cortical layer (p20), 63% in proximal 50% cortical layer (p50), increased to 76% in distal 50% cortical layer (d50), and peaked at 90% in the distal 20% cortical layer (d20). For those without peritubulitis (PTC 0), the increase in the the Interstitial Fibrosis/Tubular Atrophy (IF/TA) score was accompanied by a significantly increased cortical perfusion. A Polyomavirus infection was associated with an increased cortical perfusion. Our study demonstrated that the perfusion of the renal transplant is associated with certain pathological changes within the graft. DTPM showed a significant reduction of cortical perfusion in the transplant renal cortex related to peritubular capillary inflammation.
- 11 July 2013
- Published by Springer Nature in BMC Nephrology
- Vol. 14 (1) , 143
Open AccessCorrelation of histopathologic and dynamic tissue perfusion measurement findings in transplanted kidneys
Cortical perfusion of the renal transplant can be non-invasively assessed by color Doppler ultrasonography. We performed the Dynamic Tissue Perfusion Measurement (DTPM) of the transplant’s renal cortex using color Doppler ultrasonography (PixelFlux technique), and compared the results with the histopathological findings of transplant biopsies. Ninety-six DTPM studies of the renal transplant’s cortex followed by transplant biopsies were performed in 78 patients. The cortical perfusion data were compared with the parameter of peritubular inflammatory cell accumulation (PTC 0 to 3) based on Banff-classification system. A significant decrease of cortical perfusion could be demonstrated as the inflammatory cells accumulation in peritubular capillaries increased. Increasing peritubulitis caused a perfusion loss from central to distal layers of 79% in PTC 0, of 85% in PTC 1, of 94% in PTC 2, and of 94% in PTC 3. Furthermore, the perfusion loss due to peritubular inflammation was more prominent in the distal cortical layer. The extent of perfusion decline with increasing peritubulitis (from PTC 0 to PTC 3) was 64% in proximal 20% cortical layer (p20), 63% in proximal 50% cortical layer (p50), increased to 76% in distal 50% cortical layer (d50), and peaked at 90% in the distal 20% cortical layer (d20). For those without peritubulitis (PTC 0), the increase in the the Interstitial Fibrosis/Tubular Atrophy (IF/TA) score was accompanied by a significantly increased cortical perfusion. A Polyomavirus infection was associated with an increased cortical perfusion. Our study demonstrated that the perfusion of the renal transplant is associated with certain pathological changes within the graft. DTPM showed a significant reduction of cortical perfusion in the transplant renal cortex related to peritubular capillary inflammation.
- 10 May 2012
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 33 (07) , E88-E94
Pixelwise Quantification of Placental Perfusion Visualized by 3D Power Doppler Sonography
Purpose: We present a new method for noninvasive automatic measurement of perfusion intensity (PixelFlux method) in standardized 3 D power Doppler sonography to quantify differences of perfusion intensities among different placental layers. Materials and Methods: Power Doppler sonographic videos of anterior and central placentas were recorded at various gestational ages (13 to 38 weeks) under defined conditions in 22 women with uncomplicated pregnancies which ended in the delivery of an appropriately grown fetus. Tissue perfusion intensity in four placental layers was calculated as the product of the Doppler amplitude and the perfused area encoded by power Doppler signals related to the area of the respective layer. Measurements are given as the percentage of maximal possible perfusion. Results: Significant differences in placental perfusion intensities in the uterine wall (6.6 %), the maternal flow within the intervillous space (2.4 %), the fetal flow within placental villi (1.6 %) and the chorionic plate (9.3 %) were demonstrated with a continuous increase in the uterine wall and the placental villi. Conclusion: Placental perfusion intensity was quantified noninvasively from 3 D power Doppler signal data in an easily accomplishable manner with a new software-based measurement procedure. There are significant differences in perfusion intensities among placental layers. Placenta perfusion measurement with the PixelFlux method is feasible and can discern significant perfusion differences among different placenta layers. Ziel: Wir stellen eine neue, nicht invasive Methode vor, die eine pixelweise Bemessung der Perfusion verschiedener Plazentaschichten aus standardisierten dreidimensionalen Powerdoppler-Videos ermöglicht (PixelFlux-Methode). Material und Methoden: Standardisierte Powerdoppler-Videos anterior und zentral lokalisierter Plazenten (13.–38. Schwangerschaftswoche) von 22 Schwangeren wurden unter definierten Bedingungen untersucht. Alle Schwangerschaften führten zur Geburt eines normalgewichtigen Kindes. Die Gewebsperfusionsintensität in 4 Plazentaschichten wurde mithilfe der PixelFlux-Software als Produkt der Amplitude der Powerdoppler-Signale und der perfundierten Fläche bezogen auf die Fläche der Untersuchungsregion automatisch berechnet. Die Perfusionsintensität wurde in Prozent der maximal möglichen Perfusion angegeben. Ergebnisse: Zwischen der Uteruswand (6,6 %), der maternalen (2,4 %), der fetalen Schicht (1,6 %) und der Chorionplatte (9,3 %) konnten signifikante Perfusionsintensitätsunterschiede nachgewiesen werden. Im Verlauf der Schwangerschaft kam es zu einem kontinuierlichen Anstieg der Perfusionsintensität in der Uteruswand und den Plazentazotten. Schlussfolgerung: Die PixelFlux-Methode erlaubt die Messung der Plazentaperfusion aus dreidimensionalen Powerdoppler-Ultraschallvideos und kann Unterschiede der Perfusion der Plazentaschichten darstellen.
- 10 May 2012
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 33 (07) , E88-E94
Pixelwise Quantification of Placental Perfusion Visualized by 3D Power Doppler Sonography
Purpose: We present a new method for noninvasive automatic measurement of perfusion intensity (PixelFlux method) in standardized 3 D power Doppler sonography to quantify differences of perfusion intensities among different placental layers. Materials and Methods: Power Doppler sonographic videos of anterior and central placentas were recorded at various gestational ages (13 to 38 weeks) under defined conditions in 22 women with uncomplicated pregnancies which ended in the delivery of an appropriately grown fetus. Tissue perfusion intensity in four placental layers was calculated as the product of the Doppler amplitude and the perfused area encoded by power Doppler signals related to the area of the respective layer. Measurements are given as the percentage of maximal possible perfusion. Results: Significant differences in placental perfusion intensities in the uterine wall (6.6 %), the maternal flow within the intervillous space (2.4 %), the fetal flow within placental villi (1.6 %) and the chorionic plate (9.3 %) were demonstrated with a continuous increase in the uterine wall and the placental villi. Conclusion: Placental perfusion intensity was quantified noninvasively from 3 D power Doppler signal data in an easily accomplishable manner with a new software-based measurement procedure. There are significant differences in perfusion intensities among placental layers. Placenta perfusion measurement with the PixelFlux method is feasible and can discern significant perfusion differences among different placenta layers. Ziel: Wir stellen eine neue, nicht invasive Methode vor, die eine pixelweise Bemessung der Perfusion verschiedener Plazentaschichten aus standardisierten dreidimensionalen Powerdoppler-Videos ermöglicht (PixelFlux-Methode). Material und Methoden: Standardisierte Powerdoppler-Videos anterior und zentral lokalisierter Plazenten (13.–38. Schwangerschaftswoche) von 22 Schwangeren wurden unter definierten Bedingungen untersucht. Alle Schwangerschaften führten zur Geburt eines normalgewichtigen Kindes. Die Gewebsperfusionsintensität in 4 Plazentaschichten wurde mithilfe der PixelFlux-Software als Produkt der Amplitude der Powerdoppler-Signale und der perfundierten Fläche bezogen auf die Fläche der Untersuchungsregion automatisch berechnet. Die Perfusionsintensität wurde in Prozent der maximal möglichen Perfusion angegeben. Ergebnisse: Zwischen der Uteruswand (6,6 %), der maternalen (2,4 %), der fetalen Schicht (1,6 %) und der Chorionplatte (9,3 %) konnten signifikante Perfusionsintensitätsunterschiede nachgewiesen werden. Im Verlauf der Schwangerschaft kam es zu einem kontinuierlichen Anstieg der Perfusionsintensität in der Uteruswand und den Plazentazotten. Schlussfolgerung: Die PixelFlux-Methode erlaubt die Messung der Plazentaperfusion aus dreidimensionalen Powerdoppler-Ultraschallvideos und kann Unterschiede der Perfusion der Plazentaschichten darstellen.
- Open Access
- 1 January 2012
- Published by Hindawi Limited in Scientifica
- Vol. 2012, 1-4
Body-Surface-Area Related Renal Volume: A Common Normal Range from Birth to Adulthood
Renal volume is an important parameter of renal development. Deviations from normal volume may indicate pathologic conditions. Thus, during childhood, the ever changing renal volumes require the continuous referral to normal volume charts in order to classify actual volumes, which is rather inconvenient. In daily practice this is frequently disregarded and kidneys are evaluated by their appearance only. Therefore, we tested the hypothesis that body surface area (BSA) and renal volume grow proportionally from birth to adulthood. We divided the renal volume of a child by its BSA to get the BSA-related renal volume (BSARV) and found no differences between left and right kidneys and a normal distribution for all kidneys regardless of the patient’s age. BSARV has a common normal range for all age groups with the 10th percentile of 45 and the 90th percentile of 85 mL/m2. 80% of all kidneys do not exceed the volume of their counterparts by more than 20%. BSARV alleviates the correct evaluation of a child’s renal volume regardless of age and reveals pathological influences by the simple observation that a kidney deviates from a former percentile orz-value. This is especially valuable in the followup of kidneys with chronic diseases.
- 1 January 2012
- Published by Hindawi Limited in Scientifica
- Vol. 2012, 1-4
Open AccessBody-Surface-Area Related Renal Volume: A Common Normal Range from Birth to Adulthood
Renal volume is an important parameter of renal development. Deviations from normal volume may indicate pathologic conditions. Thus, during childhood, the ever changing renal volumes require the continuous referral to normal volume charts in order to classify actual volumes, which is rather inconvenient. In daily practice this is frequently disregarded and kidneys are evaluated by their appearance only. Therefore, we tested the hypothesis that body surface area (BSA) and renal volume grow proportionally from birth to adulthood. We divided the renal volume of a child by its BSA to get the BSA-related renal volume (BSARV) and found no differences between left and right kidneys and a normal distribution for all kidneys regardless of the patient’s age. BSARV has a common normal range for all age groups with the 10th percentile of 45 and the 90th percentile of 85 mL/m2. 80% of all kidneys do not exceed the volume of their counterparts by more than 20%. BSARV alleviates the correct evaluation of a child’s renal volume regardless of age and reveals pathological influences by the simple observation that a kidney deviates from a former percentile orz-value. This is especially valuable in the followup of kidneys with chronic diseases.
- 16 December 2011
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 32 (S 02) , E122-E128
Three-Dimensional Volumetric Spatially Angle-Corrected Pixelwise Fetal Flow Volume Measurement
Purpose: Early attempts to calculate fetal global perfusion used 2 D images. The results were not sufficiently reliable. That‘s why RI measurements are still in use despite the fact that they do not reflect the amount of blood passing through the fetus. We present a novel three-dimensional approach to overcome these limitations. Materials and Methods: In 124 singleton pregnancies between the 23rd and 4st gestational week, a three-dimensional color Doppler sonographic record of the umbilical cord was made, resulting in 281 volume data sets. With dedicated software (PixelFlux) the spatial angle of the umbilical vein was calculated and the true global fetal perfusion was calculated from its horizontal transection as the product of the area of all pixels and the spatial angle-corrected velocity. To validate the PixelFlux technique, phantom flow measurements were carried out. Results: Phantom flow measurements revealed a highly significant correlation of actual flow volumes and those measured by the PixelFlux technique (p < 0.001; rPearson = 0.987 – 0.991) with an even higher interobserver correlation (p < 0.001; rPearson = 0.997). We found a significant correlation of fetal volume flow to gestational age and weight (r = 0.529 at spatial angles below 30° to r = 0.724 at spatial angles below 5°) and a significant influence of the spatial angle on this correlation (p = 0.003; r = – 0.865). Conclusion: Spatial angle-corrected global fetal perfusion measurement improves existing approaches to fetal perfusion evaluation, and is feasible, simple and fast. Thus, it can be recommended to explore the relationship of fetal perfusion and disturbances of fetal development. Ziel: Frühere Versuche, mithilfe von zweidimensionalen Sonogrammen die fetale Gesamtperfusion zu berechnen, scheiterten an methodischen Grenzen. Daher wird zur fetalen Beurteilung noch heute die Bestimmung des Resistance-Indexes der Nabelarterie benutzt, wenngleich dessen methodische Basis unzureichend ist. Wir entwickelten daher ein neuartiges Verfahren der Flussvolumenkalkulation aus dreidimensionalen Farbdoppler-Bildern der Nabelschnur, welches hier vorgestellt wird. Material und Methoden: Aus 281 dreidimensionalen Farbdoppler-Bildern der Nabelschnur von 124 Einlingen in der 23. – 41. Schwangerschaftswoche wurden mit der PixelFlux-Software der Raumwinkel der Nabelvene und deren horizontale Querschnittsfläche pixelweise bestimmt. Daraus wurde der Volumenfluss errechnet. Zur Evaluierung der PixelFlux-Methode wurden Phantomflussmessungen vorgenommen. Ergebnisse: Die Phantomflussmessungen erbrachten eine hochsignifikante Korrelation der tatsächlichen und der mit der PixelFlux-Methode ermittelten Flussvolumina (p < 0,001; rPearson = 0,987 – 0,991) bei einer exzellenten Interobserver-Korrelation (p < 0,001; rPearson = 0,997). Wir konnten einen signifikanten Zusammenhang der raumwinkelkorrigierten fetalen Globalperfusion mit dem Fetalgewicht (r = 0,529 bei Raumwinkeln kleiner 30° bis zu r = 0,724 bei Raumwinkeln kleiner 5°) und der Schwangerschaftsdauer nachweisen, einen signifikanten Einfluss des Raumwinkels auf diesen Zusammenhang (p = 0,003; r = – 0,865) sowie den Effekt der maximal darstellbaren Flussgeschwindigkeit auf die Messungen beschreiben. Schlussfolgerung: Die neuartige Methode der raumwinkelkorrigierten fetalen globalen Perfusionsmessung überwindet methodische Schwächen herkömmlicher Verfahren der fetalen Perfusionsbeurteilung, ist schnell und einfach durchführbar. Sie kann für weitergehende Untersuchungen von Feten, deren Entwicklung und Erkrankungen empfohlen werden.
- 16 December 2011
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 32 (S 02) , E122-E128
Three-Dimensional Volumetric Spatially Angle-Corrected Pixelwise Fetal Flow Volume Measurement
Purpose: Early attempts to calculate fetal global perfusion used 2 D images. The results were not sufficiently reliable. That‘s why RI measurements are still in use despite the fact that they do not reflect the amount of blood passing through the fetus. We present a novel three-dimensional approach to overcome these limitations. Materials and Methods: In 124 singleton pregnancies between the 23rd and 4st gestational week, a three-dimensional color Doppler sonographic record of the umbilical cord was made, resulting in 281 volume data sets. With dedicated software (PixelFlux) the spatial angle of the umbilical vein was calculated and the true global fetal perfusion was calculated from its horizontal transection as the product of the area of all pixels and the spatial angle-corrected velocity. To validate the PixelFlux technique, phantom flow measurements were carried out. Results: Phantom flow measurements revealed a highly significant correlation of actual flow volumes and those measured by the PixelFlux technique (p < 0.001; rPearson = 0.987 – 0.991) with an even higher interobserver correlation (p < 0.001; rPearson = 0.997). We found a significant correlation of fetal volume flow to gestational age and weight (r = 0.529 at spatial angles below 30° to r = 0.724 at spatial angles below 5°) and a significant influence of the spatial angle on this correlation (p = 0.003; r = – 0.865). Conclusion: Spatial angle-corrected global fetal perfusion measurement improves existing approaches to fetal perfusion evaluation, and is feasible, simple and fast. Thus, it can be recommended to explore the relationship of fetal perfusion and disturbances of fetal development. Ziel: Frühere Versuche, mithilfe von zweidimensionalen Sonogrammen die fetale Gesamtperfusion zu berechnen, scheiterten an methodischen Grenzen. Daher wird zur fetalen Beurteilung noch heute die Bestimmung des Resistance-Indexes der Nabelarterie benutzt, wenngleich dessen methodische Basis unzureichend ist. Wir entwickelten daher ein neuartiges Verfahren der Flussvolumenkalkulation aus dreidimensionalen Farbdoppler-Bildern der Nabelschnur, welches hier vorgestellt wird. Material und Methoden: Aus 281 dreidimensionalen Farbdoppler-Bildern der Nabelschnur von 124 Einlingen in der 23. – 41. Schwangerschaftswoche wurden mit der PixelFlux-Software der Raumwinkel der Nabelvene und deren horizontale Querschnittsfläche pixelweise bestimmt. Daraus wurde der Volumenfluss errechnet. Zur Evaluierung der PixelFlux-Methode wurden Phantomflussmessungen vorgenommen. Ergebnisse: Die Phantomflussmessungen erbrachten eine hochsignifikante Korrelation der tatsächlichen und der mit der PixelFlux-Methode ermittelten Flussvolumina (p < 0,001; rPearson = 0,987 – 0,991) bei einer exzellenten Interobserver-Korrelation (p < 0,001; rPearson = 0,997). Wir konnten einen signifikanten Zusammenhang der raumwinkelkorrigierten fetalen Globalperfusion mit dem Fetalgewicht (r = 0,529 bei Raumwinkeln kleiner 30° bis zu r = 0,724 bei Raumwinkeln kleiner 5°) und der Schwangerschaftsdauer nachweisen, einen signifikanten Einfluss des Raumwinkels auf diesen Zusammenhang (p = 0,003; r = – 0,865) sowie den Effekt der maximal darstellbaren Flussgeschwindigkeit auf die Messungen beschreiben. Schlussfolgerung: Die neuartige Methode der raumwinkelkorrigierten fetalen globalen Perfusionsmessung überwindet methodische Schwächen herkömmlicher Verfahren der fetalen Perfusionsbeurteilung, ist schnell und einfach durchführbar. Sie kann für weitergehende Untersuchungen von Feten, deren Entwicklung und Erkrankungen empfohlen werden.