Zhe Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhe Zhang has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Xiang Luo
Beihang University
2 shared publications - Weitong Liu
Research Institute of Aero-Engine, Beihang University, Beijing 100191, China
1 shared publication - Yubo Peng
School of Energy and Power Engineering, Beihang University, Beijing 100191, China
1 shared publication - Zeyu Wu
Beihang University
1 shared publication
Latest Publications
- Open Access
- 28 March 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (4) , 452
Study on the Particle Deposition Characteristics of Transpiration Cooling Structures with Sintered Wire Mesh
Transpiration cooling based on a porous structure has an ultra-high cooling efficiency, which is expected to be one solution to improve the cooling technology of aero-engine turbine blades. However, particulate impurities in the gas flow channel continue to deposit on the surface of turbine components, blocking cooling holes, which causes great harm to the cooling of turbine blades. In this study, a sintered metal mesh plate was selected as the transpiration cooling structure, and the evolution of particle deposition quality and deposition thickness on the transpiration cooling surface with time, as well as spatial distributions of particle deposition thickness at different times, were explored through experimental and simulation methods. The results showed that, with the increase in spray time, deposition quality and maximum deposition thickness of the transpiration cooling surface gradually increased. Along the main-stream direction, when spray time was short, deposition thickness was higher in a narrow range upstream of the experimental specimen. With the increase in spray time, deposition thickness gradually decreased along the direction of the transpiration cooling mainstream. In the spanwise direction, when spray time was very short, deposition thickness in the spanwise direction was more consistent and, after spray time increased further, the deposition thickness distribution began to tend to a “∩”-type distribution. It can be seen from the simulation results of the metal wire mesh particle deposition that particles were easily deposited on the windward side of the metal wire in the main-stream direction, which agreed with the experimental distribution characteristics of the metal wire mesh deposition. Moreover, the increase in blowing ratio reduced the deposition of particles on the wall of the metal wire mesh.
- 28 March 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (4) , 452
Open AccessStudy on the Particle Deposition Characteristics of Transpiration Cooling Structures with Sintered Wire Mesh
Transpiration cooling based on a porous structure has an ultra-high cooling efficiency, which is expected to be one solution to improve the cooling technology of aero-engine turbine blades. However, particulate impurities in the gas flow channel continue to deposit on the surface of turbine components, blocking cooling holes, which causes great harm to the cooling of turbine blades. In this study, a sintered metal mesh plate was selected as the transpiration cooling structure, and the evolution of particle deposition quality and deposition thickness on the transpiration cooling surface with time, as well as spatial distributions of particle deposition thickness at different times, were explored through experimental and simulation methods. The results showed that, with the increase in spray time, deposition quality and maximum deposition thickness of the transpiration cooling surface gradually increased. Along the main-stream direction, when spray time was short, deposition thickness was higher in a narrow range upstream of the experimental specimen. With the increase in spray time, deposition thickness gradually decreased along the direction of the transpiration cooling mainstream. In the spanwise direction, when spray time was very short, deposition thickness in the spanwise direction was more consistent and, after spray time increased further, the deposition thickness distribution began to tend to a “∩”-type distribution. It can be seen from the simulation results of the metal wire mesh particle deposition that particles were easily deposited on the windward side of the metal wire in the main-stream direction, which agreed with the experimental distribution characteristics of the metal wire mesh deposition. Moreover, the increase in blowing ratio reduced the deposition of particles on the wall of the metal wire mesh.
- Open Access
Numerical Study on Convective Heat Transfer of Liquid Metal Gallium in Turbine Guide Vane
The traditional blade cooling method can no longer meet the requirements of high cooling efficiency in modern engines. In order to solve this cooling problem, this paper proposes cooling turbine guide blades based on liquid metal. The feasibility was preliminarily verified using a one-dimensional heat conduction model. Then, using a numerical method, we found that the cooling effect of liquid metal is much better than that of air cooling. The main reason for its good cooling effect is that the heat transfer coefficient of liquid metal reaches a magnitude of tens of thousands. Moreover, as the inlet temperature of the liquid metal decreases and the inlet Reynolds number increases, the liquid cooling effect becomes better. The definition of the heat transfer quality factor can reflect the reasons for the influence of the inlet temperature of the liquid metal.
Open AccessNumerical Study on Convective Heat Transfer of Liquid Metal Gallium in Turbine Guide Vane
The traditional blade cooling method can no longer meet the requirements of high cooling efficiency in modern engines. In order to solve this cooling problem, this paper proposes cooling turbine guide blades based on liquid metal. The feasibility was preliminarily verified using a one-dimensional heat conduction model. Then, using a numerical method, we found that the cooling effect of liquid metal is much better than that of air cooling. The main reason for its good cooling effect is that the heat transfer coefficient of liquid metal reaches a magnitude of tens of thousands. Moreover, as the inlet temperature of the liquid metal decreases and the inlet Reynolds number increases, the liquid cooling effect becomes better. The definition of the heat transfer quality factor can reflect the reasons for the influence of the inlet temperature of the liquid metal.