Arash Ghaffari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Arash Ghaffari has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Ole Rahbek
Aarhus University Hospital
8 shared publications Søren Kold
Interdisciplinary Orthopaedics, Orthopaedic Surgery Department, Aalborg University Hospital, Aalborg, Denmark
8 shared publicationsOle Rahbek
Interdisciplinary Orthopaedics, Orthopaedic Surgery Department, Aalborg University Hospital, Aalborg, Denmark
7 shared publications- Søren Kold
Aalborg University Hospital
6 shared publications O. Rahbek
Interdisciplinary Orthopaedics, Aalborg University Hospital, Aalborg, Denmark
4 shared publicationsS. Kold
Interdisciplinary Orthopaedics, Aalborg University Hospital, Aalborg, Denmark
4 shared publications
Latest Publications
- Open Access
- 1 February 2026
- Published by SAGE Publications in Digital Health
- Vol. 12
Continuous preoperative activity patterns measured by wearable sensors are associated with recovery after total knee arthroplasty
Objective: Physical activity is increasingly recognized as an important factor in recovery after orthopedic surgery, but objective evidence remains limited. This study examined whether wearable-derived preoperative activity levels were associated with recovery outcomes following Total Knee Arthroplasty (TKA). Methods: In this prospective longitudinal study, 30 adults undergoing unilateral TKA for knee osteoarthritis wore validated thigh-mounted accelerometers for up to two weeks preoperatively and for three months postoperatively. Participants were classified into low-, moderate-, and high-activity groups based on preoperative 24-hour activity intensity profiles. Recovery was assessed using continuous accelerometer-derived activity metrics and patient-reported outcomes (PROMs), including the Knee injury and Osteoarthritis Outcome Score (KOOS). Results: Higher preoperative activity levels were associated with more favorable objective recovery after TKA. Compared with the low-activity group, the high-activity group showed higher postoperative activity intensity and total steps, with 2.6-fold higher activity intensity and 2.2-fold higher total steps. During the first postoperative month, the high-activity group also showed faster increases in activity intensity and total steps. In contrast, KOOS subscale scores improved over time but did not differ significantly between activity groups. Conclusion: The findings of this study highlight the importance of accounting for baseline activity when interpreting wearable-derived postoperative recovery patterns. They also suggest that objective monitoring can provide information on functional recovery that may not be captured by PROMs.
- 1 February 2026
- Published by SAGE Publications in Digital Health
- Vol. 12
Open AccessContinuous preoperative activity patterns measured by wearable sensors are associated with recovery after total knee arthroplasty
Objective: Physical activity is increasingly recognized as an important factor in recovery after orthopedic surgery, but objective evidence remains limited. This study examined whether wearable-derived preoperative activity levels were associated with recovery outcomes following Total Knee Arthroplasty (TKA). Methods: In this prospective longitudinal study, 30 adults undergoing unilateral TKA for knee osteoarthritis wore validated thigh-mounted accelerometers for up to two weeks preoperatively and for three months postoperatively. Participants were classified into low-, moderate-, and high-activity groups based on preoperative 24-hour activity intensity profiles. Recovery was assessed using continuous accelerometer-derived activity metrics and patient-reported outcomes (PROMs), including the Knee injury and Osteoarthritis Outcome Score (KOOS). Results: Higher preoperative activity levels were associated with more favorable objective recovery after TKA. Compared with the low-activity group, the high-activity group showed higher postoperative activity intensity and total steps, with 2.6-fold higher activity intensity and 2.2-fold higher total steps. During the first postoperative month, the high-activity group also showed faster increases in activity intensity and total steps. In contrast, KOOS subscale scores improved over time but did not differ significantly between activity groups. Conclusion: The findings of this study highlight the importance of accounting for baseline activity when interpreting wearable-derived postoperative recovery patterns. They also suggest that objective monitoring can provide information on functional recovery that may not be captured by PROMs.
- Open Access
- 23 September 2025
- Published by Springer Nature in BMC Digital Health
- Vol. 3 (1) , 1-11
Assessing within-individual gait acceleration variability: a comparative analysis of remote monitoring and laboratory measurements
- 23 September 2025
- Published by Springer Nature in BMC Digital Health
- Vol. 3 (1) , 1-11
Open AccessAssessing within-individual gait acceleration variability: a comparative analysis of remote monitoring and laboratory measurements
- Open Access
- 10 September 2025
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 43 (12) , 2165-2177
Monitoring Gait Recovery After Total Knee Arthroplasty Using Wearable Sensors: Responsiveness of Gait Accelerations
Functional recovery after total knee arthroplasty (TKA) varies widely among individuals, and traditional assessments often fail to detect subtle changes in real‐world walking ability. Wearable sensors offer continuous and objective tracking of gait outside of clinical settings. In this prospective, longitudinal study, thirty‐one patients undergoing unilateral TKA wore thigh‐mounted accelerometers continuously from 2 weeks before surgery through 90 days postoperatively. We analyzed temporal gait features (stride time and duty factor) and frequency‐domain metrics (power of the first five frequencies of triaxial acceleration), along with weekly EQ‐5D‐3L index scores (a summary measure of health‐related quality of life) and visual analog scale (VAS) ratings (patient's self‐reported health on a 0–100 scale). Gait acceleration profiles demonstrated significant postoperative disruptions, particularly during mid‐stance and terminal swing, followed by gradual normalization, approaching baseline by day 90. Gait temporal parameters also exhibited transient alterations and recovery trends. Using LASSO logistic regression, Fourier‐derived gait features discriminated responders and non‐responders based on improvements in EQ‐5D‐3L outcomes above the minimal clinically important difference (AUC: 0.80–0.81). Specific harmonic changes across the vertical, mediolateral, and anteroposterior axes were significantly associated with the perceived health gains. The results indicated that frequency‐based gait metrics from wearable sensors are sensitive digital biomarkers for short‐term functional improvements.
- 10 September 2025
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 43 (12) , 2165-2177
Open AccessMonitoring Gait Recovery After Total Knee Arthroplasty Using Wearable Sensors: Responsiveness of Gait Accelerations
Functional recovery after total knee arthroplasty (TKA) varies widely among individuals, and traditional assessments often fail to detect subtle changes in real‐world walking ability. Wearable sensors offer continuous and objective tracking of gait outside of clinical settings. In this prospective, longitudinal study, thirty‐one patients undergoing unilateral TKA wore thigh‐mounted accelerometers continuously from 2 weeks before surgery through 90 days postoperatively. We analyzed temporal gait features (stride time and duty factor) and frequency‐domain metrics (power of the first five frequencies of triaxial acceleration), along with weekly EQ‐5D‐3L index scores (a summary measure of health‐related quality of life) and visual analog scale (VAS) ratings (patient's self‐reported health on a 0–100 scale). Gait acceleration profiles demonstrated significant postoperative disruptions, particularly during mid‐stance and terminal swing, followed by gradual normalization, approaching baseline by day 90. Gait temporal parameters also exhibited transient alterations and recovery trends. Using LASSO logistic regression, Fourier‐derived gait features discriminated responders and non‐responders based on improvements in EQ‐5D‐3L outcomes above the minimal clinically important difference (AUC: 0.80–0.81). Specific harmonic changes across the vertical, mediolateral, and anteroposterior axes were significantly associated with the perceived health gains. The results indicated that frequency‐based gait metrics from wearable sensors are sensitive digital biomarkers for short‐term functional improvements.
- Open Access
Feasibility of continuous physical activity monitoring: first-month recovery markers following joint replacement surgery
Background: The role of physical activity (PA) monitoring during the recovery after orthopaedic surgeries is unclear. This study aimed to explore early changes in the pattern and level of PA following orthopedic surgeries. Methods: This observational feasibility study included 11 hip replacement patients (four females) with a mean age of 66 years and five knee replacement patients (four females) with a mean age of 65 years. A PA tracker was used to collect the patients’ daily PA data, including duration of various activity categories, steps taken, and activity intensity count. The PA tracker recorded data from two weeks prior to surgery until four weeks after the surgery. Ratios of PA parameters for each of the first four weeks following surgery were calculated in relation to preoperative measurements. Results: Compared to preoperative measurements, during the first four weeks after the surgery, the time spent in a recumbent position decreased from 112% to 106%, while continuous walking time and activity intensity count increased from 27% to 77% and from 35% to 73%, respectively. Step counts increased from 18% to 67%, and sit-to-stands rose from 65% to 93%. No significant changes were found in sitting, standing, sporadic walk time, and sporadic steps. Conclusion: Continuously measuring PA using wearable sensors was feasible in orthopedic patients during the perioperative period. Continuous step count, walking time, activity intensity count showed noticeable changes and stable patterns demonstrating their potential for remote monitoring of patients during the early postoperative period.
Open AccessFeasibility of continuous physical activity monitoring: first-month recovery markers following joint replacement surgery
Background: The role of physical activity (PA) monitoring during the recovery after orthopaedic surgeries is unclear. This study aimed to explore early changes in the pattern and level of PA following orthopedic surgeries. Methods: This observational feasibility study included 11 hip replacement patients (four females) with a mean age of 66 years and five knee replacement patients (four females) with a mean age of 65 years. A PA tracker was used to collect the patients’ daily PA data, including duration of various activity categories, steps taken, and activity intensity count. The PA tracker recorded data from two weeks prior to surgery until four weeks after the surgery. Ratios of PA parameters for each of the first four weeks following surgery were calculated in relation to preoperative measurements. Results: Compared to preoperative measurements, during the first four weeks after the surgery, the time spent in a recumbent position decreased from 112% to 106%, while continuous walking time and activity intensity count increased from 27% to 77% and from 35% to 73%, respectively. Step counts increased from 18% to 67%, and sit-to-stands rose from 65% to 93%. No significant changes were found in sitting, standing, sporadic walk time, and sporadic steps. Conclusion: Continuously measuring PA using wearable sensors was feasible in orthopedic patients during the perioperative period. Continuous step count, walking time, activity intensity count showed noticeable changes and stable patterns demonstrating their potential for remote monitoring of patients during the early postoperative period.
- Open Access
- 8 August 2024
- Published by Elsevier in Patient Education and Counseling
- Vol. 128, 108393
The use of asynchronous digital two-way communication between patients and healthcare professionals after hospital discharge: A scoping review
- 8 August 2024
- Published by Elsevier in Patient Education and Counseling
- Vol. 128, 108393
Open AccessThe use of asynchronous digital two-way communication between patients and healthcare professionals after hospital discharge: A scoping review
- 2 January 2024
- Published by British Editorial Society of Bone & Joint Surgery in Orthopaedic Proceedings
- Vol. 106-B (SUPP_1) , 113
QUANTIFYING VARIABILITY IN DAILY ACCELERATIONS RECORDED BY INERTIAL SENSORS IN HEALTHY INDIVIDUALS: IMPLICATIONS FOR GAIT MEASUREMENT IN FREE-LIVING ENVIRONMENTS
QUANTIFYING VARIABILITY IN DAILY ACCELERATIONS RECORDED BY INERTIAL SENSORS IN HEALTHY INDIVIDUALS: IMPLICATIONS FOR GAIT MEASUREMENT IN FREE-LIVING ENVIRONMENTS
- 2 January 2024
- Published by British Editorial Society of Bone & Joint Surgery in Orthopaedic Proceedings
- Vol. 106-B (SUPP_1) , 113
QUANTIFYING VARIABILITY IN DAILY ACCELERATIONS RECORDED BY INERTIAL SENSORS IN HEALTHY INDIVIDUALS: IMPLICATIONS FOR GAIT MEASUREMENT IN FREE-LIVING ENVIRONMENTS
QUANTIFYING VARIABILITY IN DAILY ACCELERATIONS RECORDED BY INERTIAL SENSORS IN HEALTHY INDIVIDUALS: IMPLICATIONS FOR GAIT MEASUREMENT IN FREE-LIVING ENVIRONMENTS
- 2 January 2024
- Published by British Editorial Society of Bone & Joint Surgery in Orthopaedic Proceedings
- Vol. 106-B (SUPP_1) , 137
CAN WE USE SMARTPHONES TO MONITOR ORTHOPAEDIC PATIENTS' PHYSICAL ACTIVITIES DURING THE PERIOPERATIVE PERIOD? A PROSPECTIVE OBSERVATIONAL STUDY
CAN WE USE SMARTPHONES TO MONITOR ORTHOPAEDIC PATIENTS' PHYSICAL ACTIVITIES DURING THE PERIOPERATIVE PERIOD? A PROSPECTIVE OBSERVATIONAL STUDY
- 2 January 2024
- Published by British Editorial Society of Bone & Joint Surgery in Orthopaedic Proceedings
- Vol. 106-B (SUPP_1) , 137
CAN WE USE SMARTPHONES TO MONITOR ORTHOPAEDIC PATIENTS' PHYSICAL ACTIVITIES DURING THE PERIOPERATIVE PERIOD? A PROSPECTIVE OBSERVATIONAL STUDY
CAN WE USE SMARTPHONES TO MONITOR ORTHOPAEDIC PATIENTS' PHYSICAL ACTIVITIES DURING THE PERIOPERATIVE PERIOD? A PROSPECTIVE OBSERVATIONAL STUDY
- 2 January 2024
- Published by British Editorial Society of Bone & Joint Surgery in Orthopaedic Proceedings
- Vol. 106-B (SUPP_1) , 53
ACCELERATIONS RECORDED BY LOW-FREQUENCY WEARABLE SENSORS AS EFFECTIVE DISCRIMINATORS OF KNEE AND HIP OSTEOARTHRITIS
Wearable inertial sensors can detect abnormal gait associated with knee or hip osteoarthritis (OA). However, few studies have compared sensor-derived gait parameters between patients with hip and knee OA or evaluated the efficacy of sensors suitable for remote monitoring in distinguishing between the two. Hence, our study seeks to examine the differences in accelerations captured by low-frequency wearable sensors in patients with knee and hip OA and classify their gait patterns.We included patients with unilateral hip and knee OA. Gait analysis was conducted using an accelerometer ipsilateral with the affected joint on the lateral distal thighs. Statistical parametric mapping (SPM) was used to compare acceleration signals. The k-Nearest Neighbor (k-NN) algorithm was trained on 80% of the signals' Fourier coefficients and validated on the remaining 20% using 10-fold cross-validation to classify the gait patterns into hip and knee OA.We included 42 hip OA patients (19 females, age 70 [63–78], BMI of 28.3 [24.8–30.9]) and 59 knee OA patients (31 females, age 68 [62–74], BMI of 29.7 [26.3–32.6]). The SPM results indicated that one cluster (12–20%) along the vertical axis had accelerations exceeding the critical threshold of 2.956 (p=0.024). For the anteroposterior axis, three clusters were observed exceeding the threshold of 3.031 at 5–19% (p = 0.0001), 39–54% (p=0.00005), and 88–96% (p = 0.01). Regarding the mediolateral axis, four clusters were identified exceeding the threshold of 2.875 at 0–9% (p = 0.02), 14–20% (p=0.04), 28–68% (p < 0.00001), and 84–100% (p = 0.004). The k-NN model achieved an AUC of 0.79, an accuracy of 80%, and a precision of 85%.In conclusion, the Fourier coefficients of the signals recorded by wearable sensors can effectively discriminate the gait patterns of knee and hip OA. In addition, the most remarkable differences in the time domain were observed along the mediolateral axis.
- 2 January 2024
- Published by British Editorial Society of Bone & Joint Surgery in Orthopaedic Proceedings
- Vol. 106-B (SUPP_1) , 53
ACCELERATIONS RECORDED BY LOW-FREQUENCY WEARABLE SENSORS AS EFFECTIVE DISCRIMINATORS OF KNEE AND HIP OSTEOARTHRITIS
Wearable inertial sensors can detect abnormal gait associated with knee or hip osteoarthritis (OA). However, few studies have compared sensor-derived gait parameters between patients with hip and knee OA or evaluated the efficacy of sensors suitable for remote monitoring in distinguishing between the two. Hence, our study seeks to examine the differences in accelerations captured by low-frequency wearable sensors in patients with knee and hip OA and classify their gait patterns.We included patients with unilateral hip and knee OA. Gait analysis was conducted using an accelerometer ipsilateral with the affected joint on the lateral distal thighs. Statistical parametric mapping (SPM) was used to compare acceleration signals. The k-Nearest Neighbor (k-NN) algorithm was trained on 80% of the signals' Fourier coefficients and validated on the remaining 20% using 10-fold cross-validation to classify the gait patterns into hip and knee OA.We included 42 hip OA patients (19 females, age 70 [63–78], BMI of 28.3 [24.8–30.9]) and 59 knee OA patients (31 females, age 68 [62–74], BMI of 29.7 [26.3–32.6]). The SPM results indicated that one cluster (12–20%) along the vertical axis had accelerations exceeding the critical threshold of 2.956 (p=0.024). For the anteroposterior axis, three clusters were observed exceeding the threshold of 3.031 at 5–19% (p = 0.0001), 39–54% (p=0.00005), and 88–96% (p = 0.01). Regarding the mediolateral axis, four clusters were identified exceeding the threshold of 2.875 at 0–9% (p = 0.02), 14–20% (p=0.04), 28–68% (p < 0.00001), and 84–100% (p = 0.004). The k-NN model achieved an AUC of 0.79, an accuracy of 80%, and a precision of 85%.In conclusion, the Fourier coefficients of the signals recorded by wearable sensors can effectively discriminate the gait patterns of knee and hip OA. In addition, the most remarkable differences in the time domain were observed along the mediolateral axis.