Ming-Chun Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ming-Chun Lu has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
Chia-Chi Su
Department of Environmental Resources Management, Chia Nan University of Pharmacy and Science, Tainan 717, Taiwan
6 shared publicationsChia‐Chi Su
Department of Environmental Resources Management Chia‐Nan University of Pharmacy and Science Tainan 71710 Taiwan
4 shared publicationsJin Anotai
National Center of Excellence for Environmental and Hazardous Waste Management, Department of Environmental Engineering, Faculty of Engineering, King Mongkut 's University of Technology, Thonburi, Bangkok 10140, Thailand
4 shared publicationsNalinrut Masomboon
Department of Interdisciplinary programs in Environmental Science Graduate School Chulalongkorn University
4 shared publicationsChavalit Ratanatamskul
Department of Environmental Engineering, Chulalongkorn University, 254 Phayathai Rd., Pathumwan, Bangkok 10330, Thailand
3 shared publicationsLuzvisminda M. Bellotindos
Archie Eustaquio Research Laboratory, Universidad de ZamboangaZamboanga City, Philippines
3 shared publications
Latest Publications
- Open Access
- 1 March 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (11) , 5108-5118
Adsorption of dibenzothiophene sulfone from fuel using chitosan-coated bentonite (CCB) as biosorbent
Removal of dibenzothiophene sulfone (DBTS) from fuel onto chitosan-coated bentonite (CCB) was investigated using a fixed-bed column system. The experiments were carried out as a function of flow rate, particle size, and initial feed of DBTS concentration. The bed adsorption capacities were found to increase with the decreasing flow rate and particle size. Maximum bed adsorption capacities for the various flow rates were found to be 4.30, 3.09, and 2.44 mg DBTS/g CCB at 1, 5, and 10 mL/min, respectively. When the initial DBTS concentration was increased from 500 to 1,000 mg/L, the corresponding adsorption bed capacity appears to increase from 4.31 to 5.55 mg/g. Spectra studies showed possible involvement of hydroxyl groups in the biosorption. The Thomas model was used to predict the breakthrough curves under varying experimental conditions. Results indicate a good agreement between the experimental data and predicted breakthrough curves generated by the Thomas model.
- 1 March 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (11) , 5108-5118
Open AccessAdsorption of dibenzothiophene sulfone from fuel using chitosan-coated bentonite (CCB) as biosorbent
Removal of dibenzothiophene sulfone (DBTS) from fuel onto chitosan-coated bentonite (CCB) was investigated using a fixed-bed column system. The experiments were carried out as a function of flow rate, particle size, and initial feed of DBTS concentration. The bed adsorption capacities were found to increase with the decreasing flow rate and particle size. Maximum bed adsorption capacities for the various flow rates were found to be 4.30, 3.09, and 2.44 mg DBTS/g CCB at 1, 5, and 10 mL/min, respectively. When the initial DBTS concentration was increased from 500 to 1,000 mg/L, the corresponding adsorption bed capacity appears to increase from 4.31 to 5.55 mg/g. Spectra studies showed possible involvement of hydroxyl groups in the biosorption. The Thomas model was used to predict the breakthrough curves under varying experimental conditions. Results indicate a good agreement between the experimental data and predicted breakthrough curves generated by the Thomas model.
- 11 September 2014
- Published by Taylor & Francis in Journal of Toxicology and Environmental Health, Part A
- Vol. 77 (20) , 1222-1228
Seasonal Variations of Heavy Metals Content in Muscle and Viscera of Green-Lipped MusselPerna viridisFrom Da-Peng Bay Lagoon in Taiwan
As a natural lagoon, rich in biological resources including fish, crabs, and bivalves, Da-Peng Bay Lagoon receives the discharges from the neighboring rivers, Kao-ping, Dong-gang, and Lin-Bian, which have harmed the ecology and reduced the water quality of the lagoon. This study analyzes seasonal variation of heavy metals concentration (As, Cd, Cr, Cu, Hg, Ni, Pb, and Zn) in the muscle and viscera of the green-lipped mussel Perna viridis from Da-Peng Bay Lagoon. Data from this study may provide information on the use of Perna viridis as a bioindicator for heavy metals pollution in the lagoon. The heavy metals concentrations were greater in viscera than in muscles of the green-lipped mussel Perna viridis. Results showed that the mussel is capable of accumulating high contents of Cu and Zn. Generally, the order of concentrations in the muscle by season was Zn > Cu > Cr or As. In viscera, the general order of concentrations was Zn > Cu > Pb or Cr or As. Mercury was not detected in winter and spring in muscle and viscera. Cadmium displayed significant variation with season. There was also significant correlation between tissue concentration and heavy metals, including Cu, Pb, Zn, Ni, Cd, and As.
- 11 September 2014
- Published by Taylor & Francis in Journal of Toxicology and Environmental Health, Part A
- Vol. 77 (20) , 1222-1228
Seasonal Variations of Heavy Metals Content in Muscle and Viscera of Green-Lipped MusselPerna viridisFrom Da-Peng Bay Lagoon in Taiwan
As a natural lagoon, rich in biological resources including fish, crabs, and bivalves, Da-Peng Bay Lagoon receives the discharges from the neighboring rivers, Kao-ping, Dong-gang, and Lin-Bian, which have harmed the ecology and reduced the water quality of the lagoon. This study analyzes seasonal variation of heavy metals concentration (As, Cd, Cr, Cu, Hg, Ni, Pb, and Zn) in the muscle and viscera of the green-lipped mussel Perna viridis from Da-Peng Bay Lagoon. Data from this study may provide information on the use of Perna viridis as a bioindicator for heavy metals pollution in the lagoon. The heavy metals concentrations were greater in viscera than in muscles of the green-lipped mussel Perna viridis. Results showed that the mussel is capable of accumulating high contents of Cu and Zn. Generally, the order of concentrations in the muscle by season was Zn > Cu > Cr or As. In viscera, the general order of concentrations was Zn > Cu > Pb or Cr or As. Mercury was not detected in winter and spring in muscle and viscera. Cadmium displayed significant variation with season. There was also significant correlation between tissue concentration and heavy metals, including Cu, Pb, Zn, Ni, Cd, and As.
- 25 July 2014
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 21 (24) , 14158-14165
Factors affecting degradation of dimethyl sulfoxide (DMSO) by fluidized-bed Fenton process
In this study, the target compound is dimethyl sulfoxide (DMSO), which is used as a photoresist stripping solvent in the semiconductor and thin-film transistor liquid crystal display (TFT-LCD) manufacturing processes. The effects of the operating parameters (pH, Fe2+ and H2O2 concentrations) on the degradation of DMSO in the fluidized-bed Fenton process were examined. This study used the Box-Behnken design (BBD) to investigate the optimum conditions of DMSO degradation. The highest DMSO removal was 98 % for pH 3, when the H2O2 to Fe2+ molar ratio was 12. At pH 2 and 4, the highest DMSO removal was 82 %, when the H2O2 to Fe2+ molar ratio was 6.5. The correlation of DMSO removal showed that the effect of the parameters on DMSO removal followed the order Fe2+ > H2O2 > pH. From the BBD prediction, the optimum conditions were pH 3, 5 mM of Fe2+, and 60 mM of H2O2. The difference between the experimental value (98 %) and the predicted value (96 %) was not significant. The removal efficiencies of DMSO, chemical oxygen demand (COD), total organic carbon (TOC), and iron in the fluidized-bed Fenton process were higher than those in the traditional Fenton process.
- 25 July 2014
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 21 (24) , 14158-14165
Factors affecting degradation of dimethyl sulfoxide (DMSO) by fluidized-bed Fenton process
In this study, the target compound is dimethyl sulfoxide (DMSO), which is used as a photoresist stripping solvent in the semiconductor and thin-film transistor liquid crystal display (TFT-LCD) manufacturing processes. The effects of the operating parameters (pH, Fe2+ and H2O2 concentrations) on the degradation of DMSO in the fluidized-bed Fenton process were examined. This study used the Box-Behnken design (BBD) to investigate the optimum conditions of DMSO degradation. The highest DMSO removal was 98 % for pH 3, when the H2O2 to Fe2+ molar ratio was 12. At pH 2 and 4, the highest DMSO removal was 82 %, when the H2O2 to Fe2+ molar ratio was 6.5. The correlation of DMSO removal showed that the effect of the parameters on DMSO removal followed the order Fe2+ > H2O2 > pH. From the BBD prediction, the optimum conditions were pH 3, 5 mM of Fe2+, and 60 mM of H2O2. The difference between the experimental value (98 %) and the predicted value (96 %) was not significant. The removal efficiencies of DMSO, chemical oxygen demand (COD), total organic carbon (TOC), and iron in the fluidized-bed Fenton process were higher than those in the traditional Fenton process.
- 1 June 2014
- Published by Elsevier in Chemosphere
- Vol. 105, 100-105
Barium recovery by crystallization in a fluidized-bed reactor: Effects of pH, Ba/P molar ratio and seed
- 1 June 2014
- Published by Elsevier in Chemosphere
- Vol. 105, 100-105
Barium recovery by crystallization in a fluidized-bed reactor: Effects of pH, Ba/P molar ratio and seed
- 24 April 2014
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part B
- Vol. 49 (6) , 432-438
Tributyltin distribution and producing androgenic activity in water, sediment, and fish muscle
This study investigated the concentrations of Tributyltin (TBT) in water, sediment, and fish muscle samples taken from Kaohsiung Harbor and Kaoping River estuary, Taiwan. TBT concentrations in water and sediment samples ranged from less than 18.5 to 34.1 ng Sn L−1 and from 2.44 to 29.7 ng Sn g−1 weight per weight (w/w), respectively. Concentrations in the TBT‐contaminated fish muscle samples ranged from 10.8 to 79.6 ng Sn g−1 w/w. The TBT concentrations in fish muscle were higher than those in water and sediment samples. The fish muscle/water TBT bioconcentration factor (BCF) ranged from 590 to 3363 L kg−1. Additionally, the water samples were assessed for androgenic activity with an MCF7‐AR1 human breast cancer cell line. The androgenic activity ranged from 0.94 to 3.1 ng‐dihydrotestosterone per litre water (ng‐DHT L−1). Higher concentrations of TBT in water and sediment samples occurred in the dry season, but the androgenic activity had higher values in the rainy season.
- 24 April 2014
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part B
- Vol. 49 (6) , 432-438
Tributyltin distribution and producing androgenic activity in water, sediment, and fish muscle
This study investigated the concentrations of Tributyltin (TBT) in water, sediment, and fish muscle samples taken from Kaohsiung Harbor and Kaoping River estuary, Taiwan. TBT concentrations in water and sediment samples ranged from less than 18.5 to 34.1 ng Sn L−1 and from 2.44 to 29.7 ng Sn g−1 weight per weight (w/w), respectively. Concentrations in the TBT‐contaminated fish muscle samples ranged from 10.8 to 79.6 ng Sn g−1 w/w. The TBT concentrations in fish muscle were higher than those in water and sediment samples. The fish muscle/water TBT bioconcentration factor (BCF) ranged from 590 to 3363 L kg−1. Additionally, the water samples were assessed for androgenic activity with an MCF7‐AR1 human breast cancer cell line. The androgenic activity ranged from 0.94 to 3.1 ng‐dihydrotestosterone per litre water (ng‐DHT L−1). Higher concentrations of TBT in water and sediment samples occurred in the dry season, but the androgenic activity had higher values in the rainy season.
- 26 July 2013
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 21 (2) , 1208-1216
Photocatalytic degradation of acetaminophen in modified TiO2 under visible irradiation
This study investigated the photocatalytic degradation of acetaminophen (ACT) in synthetic titanium dioxide (TiO2) solution under a visible light (λ >440 nm). The TiO2 photocatalyst used in this study was synthesized via sol–gel method and doped with potassium aluminum sulfate (KAl(SO4)2) and sodium aluminate (NaAlO2). The influence of some parameters on the degradation of acetaminophen was examined, such as initial pH, photocatalyst dosage, and initial ACT concentration. The optimal operational conditions were also determined. Results showed that synthetic TiO2 catalysts presented mainly as anatase phase and no rutile phase was observed. The results of photocatalytic degradation showed that LED alone degraded negligible amount of ACT but with the presence of TiO2/KAl(SO4)2, 95 % removal of 0.10-mM acetaminophen in 540-min irradiation time was achieved. The synthetic TiO2/KAl(SO4)2 presented better photocatalytic degradation of acetaminophen than commercially available Degussa P-25. The weak crystallinity of synthesized TiO2/NaAlO2 photocatalyst showed low photocatalytic degradation than TiO2/KAl(SO4)2. The optimal operational conditions were obtained in pH 6.9 with a dose of 1.0 g/L TiO2/KAl(SO4)2 at 30 °C. Kinetic study illustrated that photocatalytic degradation of acetaminophen fits well in the pseudo-first order model. Competitive reactions from intermediates affected the degradation rate of ACT, and were more obvious as the initial ACT concentration increased.
- 26 July 2013
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 21 (2) , 1208-1216
Photocatalytic degradation of acetaminophen in modified TiO2 under visible irradiation
This study investigated the photocatalytic degradation of acetaminophen (ACT) in synthetic titanium dioxide (TiO2) solution under a visible light (λ >440 nm). The TiO2 photocatalyst used in this study was synthesized via sol–gel method and doped with potassium aluminum sulfate (KAl(SO4)2) and sodium aluminate (NaAlO2). The influence of some parameters on the degradation of acetaminophen was examined, such as initial pH, photocatalyst dosage, and initial ACT concentration. The optimal operational conditions were also determined. Results showed that synthetic TiO2 catalysts presented mainly as anatase phase and no rutile phase was observed. The results of photocatalytic degradation showed that LED alone degraded negligible amount of ACT but with the presence of TiO2/KAl(SO4)2, 95 % removal of 0.10-mM acetaminophen in 540-min irradiation time was achieved. The synthetic TiO2/KAl(SO4)2 presented better photocatalytic degradation of acetaminophen than commercially available Degussa P-25. The weak crystallinity of synthesized TiO2/NaAlO2 photocatalyst showed low photocatalytic degradation than TiO2/KAl(SO4)2. The optimal operational conditions were obtained in pH 6.9 with a dose of 1.0 g/L TiO2/KAl(SO4)2 at 30 °C. Kinetic study illustrated that photocatalytic degradation of acetaminophen fits well in the pseudo-first order model. Competitive reactions from intermediates affected the degradation rate of ACT, and were more obvious as the initial ACT concentration increased.
- 14 June 2013
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 33 (2) , 410-418
Degradation of aniline by plate and rod electrode fered‐fenton reactors: Effects of current density, Fe2+, H2O2, and aniline concentrations
This study investigates the degradation of aniline by the Fered‐Fenton process with a plate and rod electrode. The effects of electric current, H2O2, Fe2+, and aniline concentrations on the kinetic models, H2O2 efficiency, and energy consumption in aniline and chemical oxygen demand (COD) removal were examined. The kinetics of aniline degradation using the Fered‐Fenton process was second‐order. The H2O2, Fe2+, and aniline concentrations affected the COD removal efficiency more than electric current. The kinetics of aniline degradation using the Fered‐Fenton process was second‐order. In both Fered‐Fenton reactor systems, increasing the electric current, H2O2, Fe2+ and aniline concentrations significantly decreased the efficiency of H2O2 in reducing aniline and COD. The reactor design substantially affected the rate constant of aniline degradation. In general, the rate constants of aniline degradation in the plate electrode Fered‐Fenton reactor were around 1.1–6.3 times higher than that in the rod electrode Fered‐Fenton reactor. At various H2O2 concentrations, the rod electrode Fered‐Fenton reactor consumed twice as much energy in removing aniline and COD compared with the plate electrode Fered‐Fenton reactor. Additionally, COD removal required twice the energy needed to remove aniline. © 2013 American Institute of Chemical Engineers Environ Prog, 33: 410–418, 2014
- 14 June 2013
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 33 (2) , 410-418
Degradation of aniline by plate and rod electrode fered‐fenton reactors: Effects of current density, Fe2+, H2O2, and aniline concentrations
This study investigates the degradation of aniline by the Fered‐Fenton process with a plate and rod electrode. The effects of electric current, H2O2, Fe2+, and aniline concentrations on the kinetic models, H2O2 efficiency, and energy consumption in aniline and chemical oxygen demand (COD) removal were examined. The kinetics of aniline degradation using the Fered‐Fenton process was second‐order. The H2O2, Fe2+, and aniline concentrations affected the COD removal efficiency more than electric current. The kinetics of aniline degradation using the Fered‐Fenton process was second‐order. In both Fered‐Fenton reactor systems, increasing the electric current, H2O2, Fe2+ and aniline concentrations significantly decreased the efficiency of H2O2 in reducing aniline and COD. The reactor design substantially affected the rate constant of aniline degradation. In general, the rate constants of aniline degradation in the plate electrode Fered‐Fenton reactor were around 1.1–6.3 times higher than that in the rod electrode Fered‐Fenton reactor. At various H2O2 concentrations, the rod electrode Fered‐Fenton reactor consumed twice as much energy in removing aniline and COD compared with the plate electrode Fered‐Fenton reactor. Additionally, COD removal required twice the energy needed to remove aniline. © 2013 American Institute of Chemical Engineers Environ Prog, 33: 410–418, 2014
- 28 May 2013
- Published by Taylor & Francis in Environmental Technology
- Vol. 35 (1) , 89-94
Effect of the iron oxide catalyst ono-toluidine oxidation by the fluidized-bed Fenton process
This study investigates the effects of the Fe2+ concentration and synthetic iron oxide catalysts on o-toluidine degradation using a fluidized-bed Fenton process. The mineralization of o-toluidine in the synthetic catalyst system is also examined. The H3.5 and H7.3 Fe/SiO2 and A7.8 and A12.5 Fe/SiO2 catalysts were successfully synthesized by adding H2O2 and injecting air process, respectively. The optimum initial ferrous ion concentration for degradation of 1 mM o-toluidine was 1 mM. Experimental results reveal that 1 mM o-toluidine can be 100% degraded at 60 and 120 min in the modified fluidized-bed Fenton process with A7.8 Fe/SiO2 and the conventional fluidized-bed Fenton process with SiO2 carrier, respectively, when the optimum conditions of 1 mM Fe2+ and 17 mM H2O2 at pH 3 were used. The A7.8 Fe/SiO2 catalyst had a stronger oxidation ability than the H3.5 Fe/SiO2, H7.3 Fe/SiO2 and A12.5 Fe/SiO2 catalysts, and was attributed to the high iron content on the surface of the SiO2 support. The Fenton and Fenton-like reactions occurred in the A7.8 Fe/SiO2 catalyst system. Degradation of o-toluidine in the Fenton-like process follows pseudo-first-order kinetics. The A7.8 Fe/SiO2 catalyst efficiently enhanced o-toluidine oxidation under the pH range of 2–4.
- 28 May 2013
- Published by Taylor & Francis in Environmental Technology
- Vol. 35 (1) , 89-94
Effect of the iron oxide catalyst ono-toluidine oxidation by the fluidized-bed Fenton process
This study investigates the effects of the Fe2+ concentration and synthetic iron oxide catalysts on o-toluidine degradation using a fluidized-bed Fenton process. The mineralization of o-toluidine in the synthetic catalyst system is also examined. The H3.5 and H7.3 Fe/SiO2 and A7.8 and A12.5 Fe/SiO2 catalysts were successfully synthesized by adding H2O2 and injecting air process, respectively. The optimum initial ferrous ion concentration for degradation of 1 mM o-toluidine was 1 mM. Experimental results reveal that 1 mM o-toluidine can be 100% degraded at 60 and 120 min in the modified fluidized-bed Fenton process with A7.8 Fe/SiO2 and the conventional fluidized-bed Fenton process with SiO2 carrier, respectively, when the optimum conditions of 1 mM Fe2+ and 17 mM H2O2 at pH 3 were used. The A7.8 Fe/SiO2 catalyst had a stronger oxidation ability than the H3.5 Fe/SiO2, H7.3 Fe/SiO2 and A12.5 Fe/SiO2 catalysts, and was attributed to the high iron content on the surface of the SiO2 support. The Fenton and Fenton-like reactions occurred in the A7.8 Fe/SiO2 catalyst system. Degradation of o-toluidine in the Fenton-like process follows pseudo-first-order kinetics. The A7.8 Fe/SiO2 catalyst efficiently enhanced o-toluidine oxidation under the pH range of 2–4.
- Open Access
- 1 March 2013
- Published by Elsevier in Desalination and Water Treatment
- Vol. 51 (13-15) , 2820-2825
Treatment of explosive-contaminated wastewater through the Fenton process
Owing to the extremely high chemical oxygen demand (COD), toxicity, and acidity of the explosive-contaminated wastewater, biological processes cannot be directly applied for its treatment. Therefore, Fenton’s reagent was employed to treat the explosive wastewater before discharge. The Fenton process is also the easiest and most reliable method of advanced oxidation. The treatment of this wastewater with pH, COD, acetate, nitrate, and sulfate contents of 2.32, 200 g L−1, 160 g L−1, 40 g L−1, and 35 g L−1, respectively, was investigated in this study. The effects of the hydrogen peroxide feeding rate, ferrous ion dosage, and hydrogen peroxide dosage on the efficiency of the Fenton process were investigated. The optimal conditions obtained in this study for the treatment of explosive wastewater were 358 mM of Fe2+ and continuous feeding of hydrogen peroxide (0.33 mL min−1), without pH adjustment or temperature control. The highest COD removal efficiency was 70% with an oxidation efficiency (OE) of 75% in 3 h. The addition of hydrogen peroxide had no impact on the observed COD conversion.
- 1 March 2013
- Published by Elsevier in Desalination and Water Treatment
- Vol. 51 (13-15) , 2820-2825
Open AccessTreatment of explosive-contaminated wastewater through the Fenton process
Owing to the extremely high chemical oxygen demand (COD), toxicity, and acidity of the explosive-contaminated wastewater, biological processes cannot be directly applied for its treatment. Therefore, Fenton’s reagent was employed to treat the explosive wastewater before discharge. The Fenton process is also the easiest and most reliable method of advanced oxidation. The treatment of this wastewater with pH, COD, acetate, nitrate, and sulfate contents of 2.32, 200 g L−1, 160 g L−1, 40 g L−1, and 35 g L−1, respectively, was investigated in this study. The effects of the hydrogen peroxide feeding rate, ferrous ion dosage, and hydrogen peroxide dosage on the efficiency of the Fenton process were investigated. The optimal conditions obtained in this study for the treatment of explosive wastewater were 358 mM of Fe2+ and continuous feeding of hydrogen peroxide (0.33 mL min−1), without pH adjustment or temperature control. The highest COD removal efficiency was 70% with an oxidation efficiency (OE) of 75% in 3 h. The addition of hydrogen peroxide had no impact on the observed COD conversion.
- 18 December 2012
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 32 (4) , 1111-1117
Comparison of Aniline Degradation by Fenton and Electro‐Fenton Reactors Using Plate and Rod Electrodes
Aniline degradation was investigated using the conventional Fenton process and an electro‐Fenton (EF) process with plate and rod electrode EF reactors. The performance of the two EF reactors was evaluated by determining the effect of important parameters (Fe2+, H2O2, and aniline concentrations) on the aniline removal efficiency and the initial aniline degradation rate. The change in the biochemical oxygen demand (BOD5) and ratio BOD5/COD of a high concentration of aniline were also studied.Experimental results reveal that compared with conventional Fenton process, aniline degradation and chemical oxygen demand (COD) removal in the EF process increased 43% and 10%, respectively. In the two EF reactors, the aniline was completely degraded (100%) when the ratio of [H2O2]:[Fe2+]:[aniline] was 5.8:0.1:1. Within the range of Fenton's reagent used in the two reactors, controlling the H2O2 concentration was the key point of promoting the aniline oxidation. The plate electrode system had a higher efficiency than rod electrode system in terms of H2O2 efficiency, due to the reactor design of decreasing the electrical resistance. Treatment with a high concentration aniline increased biodegradability (BOD5 and ratio BOD5/COD) of pollutant when plate and rod electrode EF reactors were used. © 2012 American Institute of Chemical Engineers Environ Prog, 32: 1111–1117, 2013
- 18 December 2012
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 32 (4) , 1111-1117
Comparison of Aniline Degradation by Fenton and Electro‐Fenton Reactors Using Plate and Rod Electrodes
Aniline degradation was investigated using the conventional Fenton process and an electro‐Fenton (EF) process with plate and rod electrode EF reactors. The performance of the two EF reactors was evaluated by determining the effect of important parameters (Fe2+, H2O2, and aniline concentrations) on the aniline removal efficiency and the initial aniline degradation rate. The change in the biochemical oxygen demand (BOD5) and ratio BOD5/COD of a high concentration of aniline were also studied.Experimental results reveal that compared with conventional Fenton process, aniline degradation and chemical oxygen demand (COD) removal in the EF process increased 43% and 10%, respectively. In the two EF reactors, the aniline was completely degraded (100%) when the ratio of [H2O2]:[Fe2+]:[aniline] was 5.8:0.1:1. Within the range of Fenton's reagent used in the two reactors, controlling the H2O2 concentration was the key point of promoting the aniline oxidation. The plate electrode system had a higher efficiency than rod electrode system in terms of H2O2 efficiency, due to the reactor design of decreasing the electrical resistance. Treatment with a high concentration aniline increased biodegradability (BOD5 and ratio BOD5/COD) of pollutant when plate and rod electrode EF reactors were used. © 2012 American Institute of Chemical Engineers Environ Prog, 32: 1111–1117, 2013