Vishwanath Golash
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Vishwanath Golash has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
P. D. Willson
Kingston Hospital
1 shared publicationR. Cutress
1 shared publicationS Rahman
Departments of Surgery, Sultan Qaboos Hospital, P. O. Box No. 98, Salalah - 211, Sultanate of Oman
1 shared publication
Latest Publications
- Open Access
- 1 July 2010
- Published by Oman Medical Journal in Oman Medical Journal
- Vol. 25 (3) , 234-237
Laparo-endoscopic Assisted Percutaneous Drainage Gastrostomy and Feeding Jejunostomy
- 1 July 2010
- Published by Oman Medical Journal in Oman Medical Journal
- Vol. 25 (3) , 234-237
Open AccessLaparo-endoscopic Assisted Percutaneous Drainage Gastrostomy and Feeding Jejunostomy
- 1 July 2008
- Vol. 23 (3) , 166-9
Laparoscopic assisted two port open appendicectomy.
The laparoscopic appendicectomy can be performed using one to several ports. We present our experience of two port laparoscopic assisted open appendicectomy. The objective was to assess the results retrospectively in terms of complications and its limitations. Between years 1998-2007, a two port laparoscopic assisted appendectomy was attempted in 2380 adult patients with suspected appendicitis. The patients with localized or generalized peritonitis were included. The appendicectomy was performed via an assisted two port method using 10 mm umbilical optical port and another 10 mm port in right iliac fossa. The children aged 12 and below and pregnant patients were excluded. All patients had their laparoscopic appendicectomy within 48 hours of admission. Two port laparoscopic assisted appendicectomy was successful in 86.9% of cases. Acute appendicitis was the cause of acute abdomen in 88.9% of the patients. The accessory port was required in 8.5% of patients to complete the appendicectomy and the conversion rate to open was 4.6%. The mean operation time was 25 minutes and the mean hospital stay was 1.5 days. The port site infection was seen in 14, bleeding in 20, parietal wall abscess in three cases and intra-abdominal abscesses in 4 patients. This approach is simple, can be converted to total intracorporeal by inserting accessory port or to open appendicectomy when required and has advantage of full laparoscopy of abdomen. It has its limitations in cases of extreme obesity, thick mesentery, gangrenous appendix, very large and thick appendix, and difficulty in finding the appendix, control of bleeding, division of adhesions and to deal with other associated pathology. Cost was minimized by using non-disposable port. The overall morbidity was low. There were no specific complications related to this technique and incidence of port site infection was similar to other approaches of laparoscopic appendicectomy.
- 1 July 2008
- Vol. 23 (3) , 166-9
Laparoscopic assisted two port open appendicectomy.
The laparoscopic appendicectomy can be performed using one to several ports. We present our experience of two port laparoscopic assisted open appendicectomy. The objective was to assess the results retrospectively in terms of complications and its limitations. Between years 1998-2007, a two port laparoscopic assisted appendectomy was attempted in 2380 adult patients with suspected appendicitis. The patients with localized or generalized peritonitis were included. The appendicectomy was performed via an assisted two port method using 10 mm umbilical optical port and another 10 mm port in right iliac fossa. The children aged 12 and below and pregnant patients were excluded. All patients had their laparoscopic appendicectomy within 48 hours of admission. Two port laparoscopic assisted appendicectomy was successful in 86.9% of cases. Acute appendicitis was the cause of acute abdomen in 88.9% of the patients. The accessory port was required in 8.5% of patients to complete the appendicectomy and the conversion rate to open was 4.6%. The mean operation time was 25 minutes and the mean hospital stay was 1.5 days. The port site infection was seen in 14, bleeding in 20, parietal wall abscess in three cases and intra-abdominal abscesses in 4 patients. This approach is simple, can be converted to total intracorporeal by inserting accessory port or to open appendicectomy when required and has advantage of full laparoscopy of abdomen. It has its limitations in cases of extreme obesity, thick mesentery, gangrenous appendix, very large and thick appendix, and difficulty in finding the appendix, control of bleeding, division of adhesions and to deal with other associated pathology. Cost was minimized by using non-disposable port. The overall morbidity was low. There were no specific complications related to this technique and incidence of port site infection was similar to other approaches of laparoscopic appendicectomy.
- 1 April 2008
- Published by Wolters Kluwer Health in Surgical Laparoscopy, Endoscopy & Percutaneous Techniques
- Vol. 18 (2) , 155-156
An Experience With 1000 Consecutive Cystic Duct Ligation in Laparoscopic Cholecystectomy
Although rare, the clips are known to slip, dislodge, ulcerate, migrate, internalize, embolize, and give rise to necrosis of the cystic duct with resultant bile leak and other complications. Ligation of cystic duct has been practiced since long time with several modifications of intracorporeal and extracorporeal techniques. We have used a standard 'C' technique of intracorporeal knotting of cystic duct in 1000 consecutive patients of laparoscopic cholecystectomy. There was no case of bile leak in cystic duct ligation and no other related complications. The mean time taken for the cystic duct ligation was 3.5 minutes. This technique of total intracorporeal cystic duct and artery ligation in laparoscopic cholecystectomy is simple, secure, and economical.
- 1 April 2008
- Published by Wolters Kluwer Health in Surgical Laparoscopy, Endoscopy & Percutaneous Techniques
- Vol. 18 (2) , 155-156
An Experience With 1000 Consecutive Cystic Duct Ligation in Laparoscopic Cholecystectomy
Although rare, the clips are known to slip, dislodge, ulcerate, migrate, internalize, embolize, and give rise to necrosis of the cystic duct with resultant bile leak and other complications. Ligation of cystic duct has been practiced since long time with several modifications of intracorporeal and extracorporeal techniques. We have used a standard 'C' technique of intracorporeal knotting of cystic duct in 1000 consecutive patients of laparoscopic cholecystectomy. There was no case of bile leak in cystic duct ligation and no other related complications. The mean time taken for the cystic duct ligation was 3.5 minutes. This technique of total intracorporeal cystic duct and artery ligation in laparoscopic cholecystectomy is simple, secure, and economical.
- 1 January 2008
- Vol. 23 (1) , 42-5
Laparoscopic removal of large and sharp foreign bodies from the stomach.
Ingestion of foreign bodies is a common occurrence. Majority would pass spontaneously without any complications. Occasionally large and sharp foreign bodies may get stuck and give rise to complications. Removal of large sharp foreign bodies is recommended due to their potential of danger. Foreign bodies can be removed by endoscopy or by laparotomy. We present the two cases of laparoscopic removal of large sharp foreign bodies from the stomach. Laparoscopic removal of large sharp foreign bodies from the stomach is safe.
- 1 January 2008
- Vol. 23 (1) , 42-5
Laparoscopic removal of large and sharp foreign bodies from the stomach.
Ingestion of foreign bodies is a common occurrence. Majority would pass spontaneously without any complications. Occasionally large and sharp foreign bodies may get stuck and give rise to complications. Removal of large sharp foreign bodies is recommended due to their potential of danger. Foreign bodies can be removed by endoscopy or by laparotomy. We present the two cases of laparoscopic removal of large sharp foreign bodies from the stomach. Laparoscopic removal of large sharp foreign bodies from the stomach is safe.
- Open Access
- 1 January 2008
- Published by Medknow in Journal of Minimal Access Surgery
- Vol. 4 (2) , 54-56
A handy balloon for total extraperitoneal repair of inguinal hernia
Background: The creation of extraperitoneal space with the help of balloon is helpful in the learning curve of total extraperitoneal repair of inguinal hernia. But the cost of the balloon with other disposable items is one of the limiting factors in the popularity of this operation. By using a homemade balloon, nondispoasable ports and suturing the mesh we have been able to reduce the cost considerably. We would like to present our technique of making the balloon. Materials and Methods: Between September 2005 and November 2006 we operated 65 consecutive patients of inguinal hernia using the balloon made from the 'video camera drape'. The drape was cut and fixed on a 10 mm suction irrigation cannula. The suction irrigation cannula was used as an obturator as well to inflate the balloon in the extraperitoneal space.Results: We succeeded in creating the extraperitoneal space in all patients with the help of this balloon without any complications and conversion to open. There was no leak and bursting of the balloon. Conclusion: It is cheap, strong, sterile and readily available material for making the balloon for creating the extraperitoneal space in the laparoscopic repair of the inguinal hernia.
- 1 January 2008
- Published by Medknow in Journal of Minimal Access Surgery
- Vol. 4 (2) , 54-56
Open AccessA handy balloon for total extraperitoneal repair of inguinal hernia
Background: The creation of extraperitoneal space with the help of balloon is helpful in the learning curve of total extraperitoneal repair of inguinal hernia. But the cost of the balloon with other disposable items is one of the limiting factors in the popularity of this operation. By using a homemade balloon, nondispoasable ports and suturing the mesh we have been able to reduce the cost considerably. We would like to present our technique of making the balloon. Materials and Methods: Between September 2005 and November 2006 we operated 65 consecutive patients of inguinal hernia using the balloon made from the 'video camera drape'. The drape was cut and fixed on a 10 mm suction irrigation cannula. The suction irrigation cannula was used as an obturator as well to inflate the balloon in the extraperitoneal space.Results: We succeeded in creating the extraperitoneal space in all patients with the help of this balloon without any complications and conversion to open. There was no leak and bursting of the balloon. Conclusion: It is cheap, strong, sterile and readily available material for making the balloon for creating the extraperitoneal space in the laparoscopic repair of the inguinal hernia.
- Open Access
- 1 January 2007
- Published by Medknow in Journal of Minimal Access Surgery
- Vol. 3 (3) , 104-7
Recurrent achalasia after Heller-Toupet procedure: Laparoscopic extended redo heller myotomy and floppy Dor
Recurrences of symptoms after the surgery for achalasia cardia are not uncommon. There are several causes of recurrences but the early recurrences are speculated to be secondary to incomplete myotomy and late recurrence due to fibrosis after the myotomy or megaesophagus. These recurrences can be managed by regular dilation failing which a redo surgery is indicated. Laparoscopic approach is now standard because of the obvious benefits for patients and surgeons. Extent of myotomy and addition of fundoplication are debatable issue in the management of achalasia cardia but evidence suggests that some kind of fundoplication would be necessary after the complete division of lower esophageal sphincter. We present our experience in a case of recurrent achalasia, secondary to incomplete myotomy managed laparoscopically by extended myotomy and a floppy anterior fundoplication. Patient is asymptomatic six months after the surgery and radiologically there is free passage of barium in the stomach.
- 1 January 2007
- Published by Medknow in Journal of Minimal Access Surgery
- Vol. 3 (3) , 104-7
Open AccessRecurrent achalasia after Heller-Toupet procedure: Laparoscopic extended redo heller myotomy and floppy Dor
Recurrences of symptoms after the surgery for achalasia cardia are not uncommon. There are several causes of recurrences but the early recurrences are speculated to be secondary to incomplete myotomy and late recurrence due to fibrosis after the myotomy or megaesophagus. These recurrences can be managed by regular dilation failing which a redo surgery is indicated. Laparoscopic approach is now standard because of the obvious benefits for patients and surgeons. Extent of myotomy and addition of fundoplication are debatable issue in the management of achalasia cardia but evidence suggests that some kind of fundoplication would be necessary after the complete division of lower esophageal sphincter. We present our experience in a case of recurrent achalasia, secondary to incomplete myotomy managed laparoscopically by extended myotomy and a floppy anterior fundoplication. Patient is asymptomatic six months after the surgery and radiologically there is free passage of barium in the stomach.
- Open Access
- 1 January 2007
- Published by Medknow in Journal of Minimal Access Surgery
- Vol. 3 (2) , 73-4
Laparoscopic management of an incarcerated trocar site hernia occurred on the first postoperative day
Journal of Minimal Access Surgery (JMAS), the official publication of Indian Association of Gastrointestinal Endo Surgeons.
- 1 January 2007
- Published by Medknow in Journal of Minimal Access Surgery
- Vol. 3 (2) , 73-4
Open AccessLaparoscopic management of an incarcerated trocar site hernia occurred on the first postoperative day
Journal of Minimal Access Surgery (JMAS), the official publication of Indian Association of Gastrointestinal Endo Surgeons.
- Open Access
- 1 January 2007
- Published by Medknow in Journal of Minimal Access Surgery
- Vol. 3 (2) , 64-5
Rectus sheath abscess after laparoscopic appendicectomy
Port site wound infection, abdominal wall hematoma and intraabdominal abscess formation has been reported after laparoscopic appendicectomy. We describe here a rectus sheath abscess which occurred three weeks after the laparoscopic appendicectomy. It was most likely the result of secondary infection of the rectus sheath hematoma due to bleeding into the rectus sheath from damage to the inferior epigastric arteries or a direct tear of the rectus muscle. As far as we are aware this complication has not been reported after laparoscopic appendicectomy.
- 1 January 2007
- Published by Medknow in Journal of Minimal Access Surgery
- Vol. 3 (2) , 64-5
Open AccessRectus sheath abscess after laparoscopic appendicectomy
Port site wound infection, abdominal wall hematoma and intraabdominal abscess formation has been reported after laparoscopic appendicectomy. We describe here a rectus sheath abscess which occurred three weeks after the laparoscopic appendicectomy. It was most likely the result of secondary infection of the rectus sheath hematoma due to bleeding into the rectus sheath from damage to the inferior epigastric arteries or a direct tear of the rectus muscle. As far as we are aware this complication has not been reported after laparoscopic appendicectomy.
- Open Access
- 1 January 2007
- Published by Medknow in Journal of Minimal Access Surgery
- Vol. 3 (1) , 26-8
Necrotizing fasciitis following laparoscopic total extra peritoneal repair of left inguinal hernia
There are rare reports of necrotizing fasciitis (NF) following laparoscopic surgery. The clinical presentation of this condition may be delayed due to non-specific symptoms and sign. The diagnosis is essentially clinical and early recognition is crucial in the management. We present a case of NF of the lower abdominal wall extending to thigh, scrotum and perianal area following the laparoscopic extraperitoneal repair of left inguinal hernia managed with extensive debridment, removal of mesh, antibiotic, and skin grafting. He was seen 6 months after his surgeries and had no disability. The extensive search on Medline, Medscape, and Google engine revealed only one case report of NF following laparoscopic total extraperitoneal repair of inguinal hernia that died and this is the second case report and the only surviving one.
- 1 January 2007
- Published by Medknow in Journal of Minimal Access Surgery
- Vol. 3 (1) , 26-8
Open AccessNecrotizing fasciitis following laparoscopic total extra peritoneal repair of left inguinal hernia
There are rare reports of necrotizing fasciitis (NF) following laparoscopic surgery. The clinical presentation of this condition may be delayed due to non-specific symptoms and sign. The diagnosis is essentially clinical and early recognition is crucial in the management. We present a case of NF of the lower abdominal wall extending to thigh, scrotum and perianal area following the laparoscopic extraperitoneal repair of left inguinal hernia managed with extensive debridment, removal of mesh, antibiotic, and skin grafting. He was seen 6 months after his surgeries and had no disability. The extensive search on Medline, Medscape, and Google engine revealed only one case report of NF following laparoscopic total extraperitoneal repair of inguinal hernia that died and this is the second case report and the only surviving one.
- 17 June 2006
- Published by Springer Nature in Surgical Endoscopy
- Vol. 20 (10) , 1619-1620
Modification of Gore suture passer instrument
The Gore suture passer instrument is an ideal reusable device for various laparoscopic procedures albeit with a few drawbacks. The needle is not self-retracting inside the sheath and this leads to incomplete (manual) retraction of the needle, causing bending and breakage of the needle tip. The intracorporeal orientation of the suture grasper is difficult to maintain because the needle and suture grasper is fully rotational inside the handle. We rectified these drawbacks by inserting a spring below the connecting nut in the handle component to make the needle self-retracting. The needle and suture grasper was stabilized by a screw in the main body of the handle to fit in a longitudinal slot cut on the brass connecting nut. Our modification made the needle and suture grasper self-retracting inside the sheath and stabilize the needle during the insertion. We have used this modified suture passer on 80 patients without breakage and bending of the needle. This modification has made this device user friendly, steady, and has reduced the operation time.
- 17 June 2006
- Published by Springer Nature in Surgical Endoscopy
- Vol. 20 (10) , 1619-1620
Modification of Gore suture passer instrument
The Gore suture passer instrument is an ideal reusable device for various laparoscopic procedures albeit with a few drawbacks. The needle is not self-retracting inside the sheath and this leads to incomplete (manual) retraction of the needle, causing bending and breakage of the needle tip. The intracorporeal orientation of the suture grasper is difficult to maintain because the needle and suture grasper is fully rotational inside the handle. We rectified these drawbacks by inserting a spring below the connecting nut in the handle component to make the needle self-retracting. The needle and suture grasper was stabilized by a screw in the main body of the handle to fit in a longitudinal slot cut on the brass connecting nut. Our modification made the needle and suture grasper self-retracting inside the sheath and stabilize the needle during the insertion. We have used this modified suture passer on 80 patients without breakage and bending of the needle. This modification has made this device user friendly, steady, and has reduced the operation time.