Roberto Civinini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Roberto Civinini has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Massimo Innocenti
Orthopedic Unit, Department of Health Sciences, University of Florence, C.T.O. Largo Palagi 1, 50139 Firenze, Italy
7 shared publications - Christian Carulli
Orthopaedic Clinic University of Florence Florence Italy
6 shared publications - Fabrizio Matassi
Department of Clinical Orthopaedic University of Florence Florence Italy
5 shared publications Lorenzo Nistri
4 shared publications- Andrea Cozzi Lepri
Orthopedic Unit, Department of Health Sciences, University of Florence, Firenze, Italy
2 shared publications Birgit Redl
2 shared publications
Latest Publications
- 1 February 2017
- Published by SAGE Publications in HSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery
- Vol. 13 (1) , 28-31
The Survival of Total Knee Arthroplasty: Current Data from Registries on Tribology
Background: Polyethylene (PE) wear is a major contributor to implant loosening following total knee arthroplasty (TKA), and advanced bearings in TKA are being investigated with hopes of reducing or eliminate wear-related loosening. Currently, information on knee tribology is available from national joint registries and may be the best tools to evaluate the efficacy and safety of design innovations in joint arthroplasty. Questions/Purposes: We performed a review of national joint registries trying to answer the following questions: “Which is the main factor directly related to revisions rate in TKA?” and “Are there new bearing options better than conventional ones?” Methods: A review was performed of all published annual reports of National Joint Registers, as well as of the literature. The search was carried out using and comparing the National Joint Registers. Results: Current data from registries for total knee arthroplasty indicates that age is the major factor affecting the outcome of primary total knee replacement. The 10-year cumulative revision rate for non-cross-linked PE was 5.8% and for XLPE it was 3.5%. The effect of cross-linked polyethylene was more evident in the younger patients. The survival of the oxidized zirconium (OxZr) femoral component appears better when compared to a similar age group of patients with conventional group of prostheses. Our review suggests that the revision rates are half for the OxZr components compared to conventional CoCr femoral components. Conclusions: Age is the most relevant single factor related to revision rate. Cross-linked PE has a statistical lower revision rate at 10 years compared to conventional PE and, in the OxZr group, the revision rate is 2 times lower than Co-Cr in the same group of age.
- 1 February 2017
- Published by SAGE Publications in HSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery
- Vol. 13 (1) , 28-31
The Survival of Total Knee Arthroplasty: Current Data from Registries on Tribology
Background: Polyethylene (PE) wear is a major contributor to implant loosening following total knee arthroplasty (TKA), and advanced bearings in TKA are being investigated with hopes of reducing or eliminate wear-related loosening. Currently, information on knee tribology is available from national joint registries and may be the best tools to evaluate the efficacy and safety of design innovations in joint arthroplasty. Questions/Purposes: We performed a review of national joint registries trying to answer the following questions: “Which is the main factor directly related to revisions rate in TKA?” and “Are there new bearing options better than conventional ones?” Methods: A review was performed of all published annual reports of National Joint Registers, as well as of the literature. The search was carried out using and comparing the National Joint Registers. Results: Current data from registries for total knee arthroplasty indicates that age is the major factor affecting the outcome of primary total knee replacement. The 10-year cumulative revision rate for non-cross-linked PE was 5.8% and for XLPE it was 3.5%. The effect of cross-linked polyethylene was more evident in the younger patients. The survival of the oxidized zirconium (OxZr) femoral component appears better when compared to a similar age group of patients with conventional group of prostheses. Our review suggests that the revision rates are half for the OxZr components compared to conventional CoCr femoral components. Conclusions: Age is the most relevant single factor related to revision rate. Cross-linked PE has a statistical lower revision rate at 10 years compared to conventional PE and, in the OxZr group, the revision rate is 2 times lower than Co-Cr in the same group of age.
- 1 February 2017
- Published by SAGE Publications in HSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery
- Vol. 13 (1) , 32-34
Clinical Results of Oxidized Zirconium Femoral Component in TKA. A Review of Long-Term Survival
Background: Oxidized zirconium (OxZr) femoral component for total knee arthroplasty (TKA) have been introduced in an attempt to reduce polyethylene wear and secondary osteolysis and improve longevity of implants. Questions/Purposes: We reviewed clinical studies in literature evaluating OxZr femoral component for TKA. The aim of this review was to evaluate the clinical outcome and survival rate of TKA with an OxZr femoral component. Methods: A review of the existing literature was undertaken to collect data on the OxZr femoral component in order to provide a better understanding of its performance. Of 34 studies published in the literature, 8 met the eligibility criteria and were included in the final analysis. Results: Findings indicated that the mean Knee Society knee score improved in all series from preoperative to postoperative evaluation. The postoperative Knee Society knee score reported range from 84 to 95 and mean postoperative Knee Society functional score range from 74 to 90. The revision rate with this implant is low with up to 12.6 years of follow-up, with three revisions in total. The survival rate ranged from 100–98.7% at 5–7 years to 97.8% at 10 years. Conclusions: Excellent clinical outcome and high survival rate has been demonstrated for OxZr femoral component in TKA. No adverse reaction has been described for this new material.
- 1 February 2017
- Published by SAGE Publications in HSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery
- Vol. 13 (1) , 32-34
Clinical Results of Oxidized Zirconium Femoral Component in TKA. A Review of Long-Term Survival
Background: Oxidized zirconium (OxZr) femoral component for total knee arthroplasty (TKA) have been introduced in an attempt to reduce polyethylene wear and secondary osteolysis and improve longevity of implants. Questions/Purposes: We reviewed clinical studies in literature evaluating OxZr femoral component for TKA. The aim of this review was to evaluate the clinical outcome and survival rate of TKA with an OxZr femoral component. Methods: A review of the existing literature was undertaken to collect data on the OxZr femoral component in order to provide a better understanding of its performance. Of 34 studies published in the literature, 8 met the eligibility criteria and were included in the final analysis. Results: Findings indicated that the mean Knee Society knee score improved in all series from preoperative to postoperative evaluation. The postoperative Knee Society knee score reported range from 84 to 95 and mean postoperative Knee Society functional score range from 74 to 90. The revision rate with this implant is low with up to 12.6 years of follow-up, with three revisions in total. The survival rate ranged from 100–98.7% at 5–7 years to 97.8% at 10 years. Conclusions: Excellent clinical outcome and high survival rate has been demonstrated for OxZr femoral component in TKA. No adverse reaction has been described for this new material.
- 1 January 2013
- Published by Edikta s.r.l. in Bone Abstracts
- Vol. 10 (1) , 26-29
Growth factors in the treatment of early osteoarthritis
Regenerative medicine is the science that studies the regeneration of biological tissues obtained through use of cells, with the aid of support structures and with biomolecules such as growth factors.
- 1 January 2013
- Published by Edikta s.r.l. in Bone Abstracts
- Vol. 10 (1) , 26-29
Growth factors in the treatment of early osteoarthritis
Regenerative medicine is the science that studies the regeneration of biological tissues obtained through use of cells, with the aid of support structures and with biomolecules such as growth factors.
- 1 December 2012
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 470 (12) , 3542-3548
A Dual-mobility Cup Reduces Risk of Dislocation in Isolated Acetabular Revisions
Isolated acetabular revisions using standard cups are at risk of dislocation. The introduction of a nonconstrained dual-mobility cup was designed to improve prosthetic stability without increasing loosening rates, but it is unclear whether the risk of dislocation is reduced. We therefore determined: (1) if the rate of dislocation in isolated acetabular revisions is lower with a dual-mobility cup, (2) implant survival, (3) patient function, and (4) radiographic incidence of migration, loosening, and osteolysis. We prospectively followed 33 selected patients who underwent isolated acetabular revisions with a minimum of 2 years’ followup (mean, 3 years; range, 2–5 years). In 24 patients a stainless steel dual-mobility cup was cemented into an antiprotrusio cage, whereas in nine we used a hyaluronan dual-mobility revision cup with a foramen hook and superior and posterior flanges screw fixations. We determined Harris hip (HHS) and WOMAC scores and examined radiographs for migration, loosening, and osteolysis. There were no dislocations. Survivorship rates of the femoral and acetabular components were 97% at 5 years; the rerevision rate for any reason was 3%. At last followup, the mean HHS increased from 48 points preoperatively to 86 points. No patients had progressive osteolysis, component migration, or loosening on radiographs. In this select group of isolated acetabular revisions, our data suggest the use of a dual-mobility cup reduced the risk of dislocation without increasing loosening from 2 to 5 years. Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
- 1 December 2012
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 470 (12) , 3542-3548
A Dual-mobility Cup Reduces Risk of Dislocation in Isolated Acetabular Revisions
Isolated acetabular revisions using standard cups are at risk of dislocation. The introduction of a nonconstrained dual-mobility cup was designed to improve prosthetic stability without increasing loosening rates, but it is unclear whether the risk of dislocation is reduced. We therefore determined: (1) if the rate of dislocation in isolated acetabular revisions is lower with a dual-mobility cup, (2) implant survival, (3) patient function, and (4) radiographic incidence of migration, loosening, and osteolysis. We prospectively followed 33 selected patients who underwent isolated acetabular revisions with a minimum of 2 years’ followup (mean, 3 years; range, 2–5 years). In 24 patients a stainless steel dual-mobility cup was cemented into an antiprotrusio cage, whereas in nine we used a hyaluronan dual-mobility revision cup with a foramen hook and superior and posterior flanges screw fixations. We determined Harris hip (HHS) and WOMAC scores and examined radiographs for migration, loosening, and osteolysis. There were no dislocations. Survivorship rates of the femoral and acetabular components were 97% at 5 years; the rerevision rate for any reason was 3%. At last followup, the mean HHS increased from 48 points preoperatively to 86 points. No patients had progressive osteolysis, component migration, or loosening on radiographs. In this select group of isolated acetabular revisions, our data suggest the use of a dual-mobility cup reduced the risk of dislocation without increasing loosening from 2 to 5 years. Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
- 17 March 2012
- Published by Springer Nature in International Orthopaedics
- Vol. 36 (8) , 1583-1588
The use of an injectable calcium sulphate/calcium phosphate bioceramic in the treatment of osteonecrosis of the femoral head
Purpose The purpose of our study is to describe the rationale, the surgical technique and the early clinical and radiographic results of the treatment of patients with early stage osteonecrosis of the femoral head (ONFH) by performing: core decompression, injection of autologous bone marrow concentrate and the use of a new composite injectable bone substitute (PRO-DENSE®), as a mechanical supplementation associated with decompression. Methods The study included 37 hips (31 patients, 14 females, 17 males; mean age 43.9 years, range 24–56 years) with stages IC–IIIA ONFH. The outcome was determined by the changes in the Harris hip score (HHS), by progression in radiographic stages and by the need for hip replacement. The mean follow-up was 20.6 months (range 12–32 months). Results At final follow-up the mean HHS increased from 68 points pre-operatively to 86 points post-operatively. The radiological results showed that 29 hips (78.4 %) improved or had no further collapse. The overall clinical success rate of the procedure was 86.5 %, with three conversions to THA, and a failure rate of only 3.3 % in the pre-collapse group. Conclusions We are encouraged by these early results using core decompression, injection of the autologous bone marrow concentrate and backfilling the defect with an injectable bioceramic for the treatment of early stages of ONFH; as far as a conclusion can be drawn from the current data, this treatment seems to relieve hip pain and prevent the progression of ONFH in the majority of the cases.
- 17 March 2012
- Published by Springer Nature in International Orthopaedics
- Vol. 36 (8) , 1583-1588
The use of an injectable calcium sulphate/calcium phosphate bioceramic in the treatment of osteonecrosis of the femoral head
Purpose The purpose of our study is to describe the rationale, the surgical technique and the early clinical and radiographic results of the treatment of patients with early stage osteonecrosis of the femoral head (ONFH) by performing: core decompression, injection of autologous bone marrow concentrate and the use of a new composite injectable bone substitute (PRO-DENSE®), as a mechanical supplementation associated with decompression. Methods The study included 37 hips (31 patients, 14 females, 17 males; mean age 43.9 years, range 24–56 years) with stages IC–IIIA ONFH. The outcome was determined by the changes in the Harris hip score (HHS), by progression in radiographic stages and by the need for hip replacement. The mean follow-up was 20.6 months (range 12–32 months). Results At final follow-up the mean HHS increased from 68 points pre-operatively to 86 points post-operatively. The radiological results showed that 29 hips (78.4 %) improved or had no further collapse. The overall clinical success rate of the procedure was 86.5 %, with three conversions to THA, and a failure rate of only 3.3 % in the pre-collapse group. Conclusions We are encouraged by these early results using core decompression, injection of the autologous bone marrow concentrate and backfilling the defect with an injectable bioceramic for the treatment of early stages of ONFH; as far as a conclusion can be drawn from the current data, this treatment seems to relieve hip pain and prevent the progression of ONFH in the majority of the cases.
- 1 January 2011
- Vol. 8 (1) , 25-31
The use of autologous blood-derived growth factors in bone regeneration.
Platelet-rich plasma (PRP) is defined as a portion of the plasma fraction of autologous blood having platelet concentrations above baseline. When activated the platelets release growth factors that play an essential role in bone healing such as Platelet-derived Growth Factor, Transforming Growth Factor-β, Vascular Endothelial Growth Factor and others.Multiple basic science and in vivo animal studies agree that PRP has a role in the stimulation of the healing cascade in ligament, tendon, muscle cartilage and in bone regeneration in the last years PRP had a widespread diffusion in the treatment of soft tissue and bone healing.The purpose of this review is to describe the biological properties of platelets and its factors, the methods used for producing PRP, to provide a background on the underlying basic science and an overview of evidence based medicine on clinical application of PRP in bone healing.
- 1 January 2011
- Vol. 8 (1) , 25-31
The use of autologous blood-derived growth factors in bone regeneration.
Platelet-rich plasma (PRP) is defined as a portion of the plasma fraction of autologous blood having platelet concentrations above baseline. When activated the platelets release growth factors that play an essential role in bone healing such as Platelet-derived Growth Factor, Transforming Growth Factor-β, Vascular Endothelial Growth Factor and others.Multiple basic science and in vivo animal studies agree that PRP has a role in the stimulation of the healing cascade in ligament, tendon, muscle cartilage and in bone regeneration in the last years PRP had a widespread diffusion in the treatment of soft tissue and bone healing.The purpose of this review is to describe the biological properties of platelets and its factors, the methods used for producing PRP, to provide a background on the underlying basic science and an overview of evidence based medicine on clinical application of PRP in bone healing.
- 1 May 2010
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 468 (5) , 1258-1263
The 5-year Results of an Oxidized Zirconium Femoral Component for TKA
Osteolysis secondary to polyethylene wear is one of the major factors limiting long-term performance of TKA. Oxidized zirconium is a new material that combines the strength of a metal with the wear properties of a ceramic. It remains unknown whether implants with a zirconium femoral component can be used safely in TKA. To answer that question, we reviewed, at a minimum of 5 years, the clinical outcome and survivorship of a ceramic-surfaced oxidized zirconium femoral component implanted during 98 primary TKAs between April 2001 and December 2003. Survivorship was 98.7% at 7 years postoperatively. No revision was necessary and only one component failed because of aseptic loosening. Mean Knee Society score improved from 36 to 89. No adverse events were observed clinically or radiologically. These results justify pursuing the use of oxidized zirconium as an alternative bearing surface for a femoral component in TKA. Level of Evidence: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
- 1 May 2010
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 468 (5) , 1258-1263
The 5-year Results of an Oxidized Zirconium Femoral Component for TKA
Osteolysis secondary to polyethylene wear is one of the major factors limiting long-term performance of TKA. Oxidized zirconium is a new material that combines the strength of a metal with the wear properties of a ceramic. It remains unknown whether implants with a zirconium femoral component can be used safely in TKA. To answer that question, we reviewed, at a minimum of 5 years, the clinical outcome and survivorship of a ceramic-surfaced oxidized zirconium femoral component implanted during 98 primary TKAs between April 2001 and December 2003. Survivorship was 98.7% at 7 years postoperatively. No revision was necessary and only one component failed because of aseptic loosening. Mean Knee Society score improved from 36 to 89. No adverse events were observed clinically or radiologically. These results justify pursuing the use of oxidized zirconium as an alternative bearing surface for a femoral component in TKA. Level of Evidence: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
- 13 January 2007
- Published by Springer Nature in International Orthopaedics
- Vol. 32 (2) , 189-193
Acetabular revisions using a cementless oblong cup: five to ten year results
The purpose of this paper was to evaluate the results of acetabular revisions with the use of an oblong revision cup that is designed with its longitudinal diameter elongated relative to its transverse diameter. Between 1996 and 2001, 62 hips in 60 patients underwent an acetabular revision with the insertion of a LOR acetabular component. Seven hips were lost to follow-up or the patients died; the remaining 55 hips (53 patients) remained in follow-up for an average of 7.2 years (range: 5.0–10.1 years). One socket was revised for aseptic loosening, and another was operated on for a late polyethylene liner dissociation. The average Harris hip score (HHS) improved from 34 to 79. Results were rated as excellent in 16 hips, good in 28, fair in six and poor in three. Radiographic analysis demonstrated an improvement in the average vertical displacement of the hip centre: 49 hips had a well-fixed, bone-ingrown cup and four had a stable fibrous union. For large superolateral acetabular bone deficiencies, this implant facilitated a complex reconstruction without the need for bulk structural acetabular bone grafts, provided good clinical results and showed satisfactory stability at the midterm follow-up.
- 13 January 2007
- Published by Springer Nature in International Orthopaedics
- Vol. 32 (2) , 189-193
Acetabular revisions using a cementless oblong cup: five to ten year results
The purpose of this paper was to evaluate the results of acetabular revisions with the use of an oblong revision cup that is designed with its longitudinal diameter elongated relative to its transverse diameter. Between 1996 and 2001, 62 hips in 60 patients underwent an acetabular revision with the insertion of a LOR acetabular component. Seven hips were lost to follow-up or the patients died; the remaining 55 hips (53 patients) remained in follow-up for an average of 7.2 years (range: 5.0–10.1 years). One socket was revised for aseptic loosening, and another was operated on for a late polyethylene liner dissociation. The average Harris hip score (HHS) improved from 34 to 79. Results were rated as excellent in 16 hips, good in 28, fair in six and poor in three. Radiographic analysis demonstrated an improvement in the average vertical displacement of the hip centre: 49 hips had a well-fixed, bone-ingrown cup and four had a stable fibrous union. For large superolateral acetabular bone deficiencies, this implant facilitated a complex reconstruction without the need for bulk structural acetabular bone grafts, provided good clinical results and showed satisfactory stability at the midterm follow-up.