Nagesh Nagabhushana Bhat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nagesh Nagabhushana Bhat has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Balvinder Kaur Sapra
Radiological Physics and Advisory Division, Bhabha Atomic Research Centre (BARC), Mumbai, India
9 shared publications - Rajesh Kumar Chaurasia
Radiological Physics and Advisory Division, Bhabha Atomic Research Centre (BARC), Mumbai, India
9 shared publications Usha Yadav
Bhabha Atomic Research Centre (BARC), Mumbai, India
7 shared publicationsKapil B. Shirsath
Radiological Physics and Advisory Division, Bhabha Atomic Research Centre (BARC), Mumbai, India
5 shared publications- Arshad Khan
Radiological Physics and Advisory Division, Bhabha Atomic Research Centre (BARC), Mumbai, India
4 shared publications Balvinder K. Sapra
Radiological Physics and Advisory Division, Bhabha Atomic Research Centre (BARC), Mumbai, India
4 shared publications
Latest Publications
- Open Access
A Rare Constitutional Centromeric Expansion of Chromosome 1 in a Phenotypically Normal Individual: A Comprehensive Cytogenetic Study
Constitutional centromeric heteromorphisms are uncommon chromosomal variants that may complicate cytogenetic interpretation. We report a constitutional enlargement of the centromeric region of one chromosome 1 homologue identified incidentally during biological dose estimation in a suspected occupationally exposed individual. Conventional cytogenetics, pan-centromeric fluorescence in situ hybridization (FISH), and multiplex FISH confirmed the variant and excluded cryptic chromosomal rearrangements. Analysis of 500 metaphases revealed no dicentric chromosomes. Quantitative assessment demonstrated a centromere-to-chromosome length ratio of 0.314 ± 0.019 for the enlarged homologue compared with 0.169 ± 0.019 for the unaffected homologue and 0.161–0.186 in controls, representing an approximately 1.86-fold increase (t = 28.4, p < 0.0001). The findings establish a benign constitutional centromeric heteromorphism of chromosome 1 and highlight the importance of distinguishing such variants from structural chromosomal abnormalities during routine cytogenetic evaluation.
Open AccessA Rare Constitutional Centromeric Expansion of Chromosome 1 in a Phenotypically Normal Individual: A Comprehensive Cytogenetic Study
Constitutional centromeric heteromorphisms are uncommon chromosomal variants that may complicate cytogenetic interpretation. We report a constitutional enlargement of the centromeric region of one chromosome 1 homologue identified incidentally during biological dose estimation in a suspected occupationally exposed individual. Conventional cytogenetics, pan-centromeric fluorescence in situ hybridization (FISH), and multiplex FISH confirmed the variant and excluded cryptic chromosomal rearrangements. Analysis of 500 metaphases revealed no dicentric chromosomes. Quantitative assessment demonstrated a centromere-to-chromosome length ratio of 0.314 ± 0.019 for the enlarged homologue compared with 0.169 ± 0.019 for the unaffected homologue and 0.161–0.186 in controls, representing an approximately 1.86-fold increase (t = 28.4, p < 0.0001). The findings establish a benign constitutional centromeric heteromorphism of chromosome 1 and highlight the importance of distinguishing such variants from structural chromosomal abnormalities during routine cytogenetic evaluation.
- 23 September 2026
- Published by Taylor & Francis in International Journal of Radiation Biology
- p. 1-9
Radiation-induced chromosomal aberrations in pediatric patients with inborn errors of immunity: a G 0 -phase approach to assess radiosensitivity
Ionizing radiation is well known to induce DNA double strand breaks which can be deleterious if induced in large numbers and mis-repaired to produce mutations and chromosomal aberrations (Negrini e...
- 23 September 2026
- Published by Taylor & Francis in International Journal of Radiation Biology
- p. 1-9
Radiation-induced chromosomal aberrations in pediatric patients with inborn errors of immunity: a G 0 -phase approach to assess radiosensitivity
Ionizing radiation is well known to induce DNA double strand breaks which can be deleterious if induced in large numbers and mis-repaired to produce mutations and chromosomal aberrations (Negrini e...
- Open Access
- 2 June 2026
- Published by Springer Nature in Research Square
Establishment of a Dose-Response Curve for ⁶⁰Co γ-radiation-Induced Dicentric plus Ring Chromosomes: An Activity of the Indian Biodosimetry Network (IN-BioDoS)
Background: For precise biological dose measurement during radiation crises, a consistent dose-response curve for dicentric plus ring chromosomes caused by ionizing radiation must be established. This program, which is a part of the Indian Biodosimetry Network (IN-BioDoS), seeks to improve national capability for quick radiation dose estimation, strengthen interlaboratory readiness, and standardize cytogenetic biodosimetry procedures. Purpose: To construct a consistent cytogenetic dose–response curve for ⁶⁰Co γ-radiation utilizing dicentric plus ring chromosomes for reliable biodosimetry and emergency radiation dose assessment. Methods: , as the central coordinating laboratory, performed controlled irradiations (n = 4), followed by whole blood culture and metaphase slide preparation. The prepared slides were then transferred in a blinded manner to Nitte (Deemed to be University) for independent manual scoring under bright-field microscopy. Results: The resulting data were used to construct a dose-response calibration curve [Y = (0.029 ± 0.0006) *D + (0.043 ± 0.003) *D 2 + (0.0001 ± 0.0008)], with the derived coefficients falling within previously reported ranges. Validation using five blinded samples (0.1 - 4 Gy) demonstrated good agreement between estimated and delivered doses. All true doses fell within their respective 95% confidence intervals. Absolute deviations ranged from 0.039 to 0.366 Gy, with all estimates lying within ±0.5 Gy of the true dose. Relative accuracy analysis showed that 80% of estimates are within ±25% of the delivered dose, with the only larger deviation observed at 0.1 Gy (+39.0%), reflecting inherent limitations at very low dose levels. The overall mean absolute deviation was 0.174 Gy, indicating satisfactory accuracy for practical biodosimetry applications. These findings demonstrate the reliability of the established calibration curve for retrospective dose estimation, particularly in clinically relevant dose ranges. Conclusions: The study highlights the importance of methodological harmonization and collaborative frameworks within the IN-BioDoS network to strengthen national preparedness for radiation emergency response and to support informed decision-making in public health and radiation protection.
- 2 June 2026
- Published by Springer Nature in Research Square
Open AccessEstablishment of a Dose-Response Curve for ⁶⁰Co γ-radiation-Induced Dicentric plus Ring Chromosomes: An Activity of the Indian Biodosimetry Network (IN-BioDoS)
Background: For precise biological dose measurement during radiation crises, a consistent dose-response curve for dicentric plus ring chromosomes caused by ionizing radiation must be established. This program, which is a part of the Indian Biodosimetry Network (IN-BioDoS), seeks to improve national capability for quick radiation dose estimation, strengthen interlaboratory readiness, and standardize cytogenetic biodosimetry procedures. Purpose: To construct a consistent cytogenetic dose–response curve for ⁶⁰Co γ-radiation utilizing dicentric plus ring chromosomes for reliable biodosimetry and emergency radiation dose assessment. Methods: , as the central coordinating laboratory, performed controlled irradiations (n = 4), followed by whole blood culture and metaphase slide preparation. The prepared slides were then transferred in a blinded manner to Nitte (Deemed to be University) for independent manual scoring under bright-field microscopy. Results: The resulting data were used to construct a dose-response calibration curve [Y = (0.029 ± 0.0006) *D + (0.043 ± 0.003) *D 2 + (0.0001 ± 0.0008)], with the derived coefficients falling within previously reported ranges. Validation using five blinded samples (0.1 - 4 Gy) demonstrated good agreement between estimated and delivered doses. All true doses fell within their respective 95% confidence intervals. Absolute deviations ranged from 0.039 to 0.366 Gy, with all estimates lying within ±0.5 Gy of the true dose. Relative accuracy analysis showed that 80% of estimates are within ±25% of the delivered dose, with the only larger deviation observed at 0.1 Gy (+39.0%), reflecting inherent limitations at very low dose levels. The overall mean absolute deviation was 0.174 Gy, indicating satisfactory accuracy for practical biodosimetry applications. These findings demonstrate the reliability of the established calibration curve for retrospective dose estimation, particularly in clinically relevant dose ranges. Conclusions: The study highlights the importance of methodological harmonization and collaborative frameworks within the IN-BioDoS network to strengthen national preparedness for radiation emergency response and to support informed decision-making in public health and radiation protection.
- Open Access
- 10 February 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Pan centromeric FISH enhances precision in radiation biodosimetry
Accurate biodosimetry is critical for assessing radiation exposure in radiological emergencies, occupational monitoring, and clinical management, where precise dose estimation informs life-saving decisions and regulatory compliance. Current gold-standard cytogenetic methods face limitations in sensitivity and reproducibility, especially at low doses (< 0.5 Gy) (practical limitations at low doses, including very low dicentric yields, higher statistical noise, and greater scoring uncertainty as aberration frequencies near background levels). This study presents a systematic comparison of pan-centromeric fluorescence in situ hybridization (pan-cent-FISH) and Giemsa staining for detecting dicentric (DC) and ring (R) chromosomes following 60 Co-γ irradiation (0–3 Gy). Analysis of more than 15,000 metaphases per technique revealed enhanced sensitivity of pan-cent-FISH technique, demonstrating a 1.72-fold higher linear coefficient and enhanced (1.13-fold) quadratic coefficient (β), indicating improved sensitivity across both low and high dose ranges. Blind validation with eight samples showed pan-cent-FISH achieved ~ 2-fold greater accuracy, with mean absolute differences of 0.0538 Gy (vs. 0.1105 Gy for Giemsa) and average relative errors of 7.13% (vs. 15.35% for Giemsa). At low doses (0.1 Gy), pan-cent-FISH maintained 9.0% error, while Giemsa exceeded acceptable limits (21.0% error). The standardized fluorescence detection used for the technique eliminated morphological ambiguities, reducing false negatives by ~ 40% and improving first-pass accuracy.
- 10 February 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessPan centromeric FISH enhances precision in radiation biodosimetry
Accurate biodosimetry is critical for assessing radiation exposure in radiological emergencies, occupational monitoring, and clinical management, where precise dose estimation informs life-saving decisions and regulatory compliance. Current gold-standard cytogenetic methods face limitations in sensitivity and reproducibility, especially at low doses (< 0.5 Gy) (practical limitations at low doses, including very low dicentric yields, higher statistical noise, and greater scoring uncertainty as aberration frequencies near background levels). This study presents a systematic comparison of pan-centromeric fluorescence in situ hybridization (pan-cent-FISH) and Giemsa staining for detecting dicentric (DC) and ring (R) chromosomes following 60 Co-γ irradiation (0–3 Gy). Analysis of more than 15,000 metaphases per technique revealed enhanced sensitivity of pan-cent-FISH technique, demonstrating a 1.72-fold higher linear coefficient and enhanced (1.13-fold) quadratic coefficient (β), indicating improved sensitivity across both low and high dose ranges. Blind validation with eight samples showed pan-cent-FISH achieved ~ 2-fold greater accuracy, with mean absolute differences of 0.0538 Gy (vs. 0.1105 Gy for Giemsa) and average relative errors of 7.13% (vs. 15.35% for Giemsa). At low doses (0.1 Gy), pan-cent-FISH maintained 9.0% error, while Giemsa exceeded acceptable limits (21.0% error). The standardized fluorescence detection used for the technique eliminated morphological ambiguities, reducing false negatives by ~ 40% and improving first-pass accuracy.
- Open Access
- 7 July 2025
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 45 (3) , 031501
Strengthening radiation response and expanding cytogenetic applications: Indian biodosimetry network (IN-BioDoS)
As nuclear energy and radiation applications expand, advancing biodosimetry is crucial for assessing radiation exposure, especially during radiological emergencies. The Bhabha Atomic Research Centre’s (BARC) Biodosimetry Laboratory has pioneered dose estimation techniques, including dicentric chromosome assay, cytokinesis block micronucleus assay, Chromosomal translocation by fluorescence in situ hybridisation, γH2AX, 53BP1, and premature chromosome condensation. To enhance preparedness, BARC has launched the Indian biodosimetry network, integrating cytogenetic with an aim to standardise methods, promote collaboration, and ensure accurate dose assessments through inter-laboratory comparisons. Future expansions, including rapid biodosimetry techniques and global partnerships, will strengthen the handling of radiation emergencies. These techniques also hold potential in clinical diagnostics, personalised medicine, and drug testing, reinforcing societal applications in medical care.
- 7 July 2025
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 45 (3) , 031501
Open AccessStrengthening radiation response and expanding cytogenetic applications: Indian biodosimetry network (IN-BioDoS)
As nuclear energy and radiation applications expand, advancing biodosimetry is crucial for assessing radiation exposure, especially during radiological emergencies. The Bhabha Atomic Research Centre’s (BARC) Biodosimetry Laboratory has pioneered dose estimation techniques, including dicentric chromosome assay, cytokinesis block micronucleus assay, Chromosomal translocation by fluorescence in situ hybridisation, γH2AX, 53BP1, and premature chromosome condensation. To enhance preparedness, BARC has launched the Indian biodosimetry network, integrating cytogenetic with an aim to standardise methods, promote collaboration, and ensure accurate dose assessments through inter-laboratory comparisons. Future expansions, including rapid biodosimetry techniques and global partnerships, will strengthen the handling of radiation emergencies. These techniques also hold potential in clinical diagnostics, personalised medicine, and drug testing, reinforcing societal applications in medical care.
- Open Access
- 30 May 2025
- Published by Springer Nature in Research Square
Pan centromeric FISH enhances precision in radiation biodosimetry
Accurate biodosimetry is critical for assessing radiation exposure in radiological emergencies, occupational monitoring, and clinical management, where precise dose estimation informs life-saving decisions and regulatory compliance. Current gold-standard cytogenetic methods face limitations in sensitivity and reproducibility, especially at low doses (< 0.5 Gy). This study presents a systematic comparison of pan-centromeric fluorescence in situ hybridization (pan-cent-FISH) and Giemsa staining for detecting dicentric (DC) and ring (R) chromosomes following 60 Co-γ irradiation (0–3 Gy). Analysis of 3,500 metaphases per technique revealed enhanced sensitivity of pan-cent-FISH technique, demonstrating a 2.1-fold higher linear coefficient and enhanced (1.2-fold) quadratic coefficient (β), indicating improved sensitivity across both low and high dose ranges. Blind validation with eight samples showed pan-cent-FISH achieved 2.3-fold greater accuracy, with mean absolute differences of 0.058 Gy (vs. 0.113 Gy for Giemsa) and relative errors of 6.93% (vs. 16.03% for Giemsa). At low doses (0.1 Gy), pan-cent-FISH maintained 8.0% error, while Giemsa exceeded acceptable limits (23.0% error). The standardized fluorescence detection used for the technique eliminated morphological ambiguities, reducing false negatives by 40% and improving first-pass accuracy.
- 30 May 2025
- Published by Springer Nature in Research Square
Open AccessPan centromeric FISH enhances precision in radiation biodosimetry
Accurate biodosimetry is critical for assessing radiation exposure in radiological emergencies, occupational monitoring, and clinical management, where precise dose estimation informs life-saving decisions and regulatory compliance. Current gold-standard cytogenetic methods face limitations in sensitivity and reproducibility, especially at low doses (< 0.5 Gy). This study presents a systematic comparison of pan-centromeric fluorescence in situ hybridization (pan-cent-FISH) and Giemsa staining for detecting dicentric (DC) and ring (R) chromosomes following 60 Co-γ irradiation (0–3 Gy). Analysis of 3,500 metaphases per technique revealed enhanced sensitivity of pan-cent-FISH technique, demonstrating a 2.1-fold higher linear coefficient and enhanced (1.2-fold) quadratic coefficient (β), indicating improved sensitivity across both low and high dose ranges. Blind validation with eight samples showed pan-cent-FISH achieved 2.3-fold greater accuracy, with mean absolute differences of 0.058 Gy (vs. 0.113 Gy for Giemsa) and relative errors of 6.93% (vs. 16.03% for Giemsa). At low doses (0.1 Gy), pan-cent-FISH maintained 8.0% error, while Giemsa exceeded acceptable limits (23.0% error). The standardized fluorescence detection used for the technique eliminated morphological ambiguities, reducing false negatives by 40% and improving first-pass accuracy.
- Open Access
- 12 July 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-14
G0-PCC-FISH derived multi-parametric biodosimetry methodology for accidental high dose and partial body exposures
High dose radiation exposures are rare. However, medical management of such incidents is crucial due to mortality and tissue injury risks. Rapid radiation biodosimetry of high dose accidental exposures is highly challenging, considering that they usually involve non uniform fields leading to partial body exposures. The gold standard, dicentric assay and other conventional methods have limited application in such scenarios. As an alternative, we propose Premature Chromosome Condensation combined with Fluorescent In-situ Hybridization (G0-PCC-FISH) as a promising tool for partial body exposure biodosimetry. In the present study, partial body exposures were simulated ex-vivo by mixing of uniformly exposed blood with unexposed blood in varying proportions. After G0-PCC-FISH, Dolphin’s approach with background correction was used to provide partial body exposure dose estimates and these were compared with those obtained from conventional dicentric assay and G0-PCC-Fragment assay (conventional G0-PCC). Dispersion analysis of aberrations from partial body exposures was carried out and compared with that of whole-body exposures. The latter was inferred from a multi-donor, wide dose range calibration curve, a-priori established for whole-body exposures. With the dispersion analysis, novel multi-parametric methodology for discerning the partial body exposure from whole body exposure and accurate dose estimation has been formulated and elucidated with the help of an example. Dose and proportion dependent reduction in sensitivity and dose estimation accuracy was observed for Dicentric assay, but not in the two PCC methods. G0-PCC-FISH was found to be most accurate for the dose estimation. G0-PCC-FISH has potential to overcome the shortcomings of current available methods and can provide rapid, accurate dose estimation of partial body and high dose accidental exposures. Biological dose estimation can be useful to predict progression of disease manifestation and can help in pre-planning of appropriate & timely medical intervention.
- 12 July 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-14
Open AccessG0-PCC-FISH derived multi-parametric biodosimetry methodology for accidental high dose and partial body exposures
High dose radiation exposures are rare. However, medical management of such incidents is crucial due to mortality and tissue injury risks. Rapid radiation biodosimetry of high dose accidental exposures is highly challenging, considering that they usually involve non uniform fields leading to partial body exposures. The gold standard, dicentric assay and other conventional methods have limited application in such scenarios. As an alternative, we propose Premature Chromosome Condensation combined with Fluorescent In-situ Hybridization (G0-PCC-FISH) as a promising tool for partial body exposure biodosimetry. In the present study, partial body exposures were simulated ex-vivo by mixing of uniformly exposed blood with unexposed blood in varying proportions. After G0-PCC-FISH, Dolphin’s approach with background correction was used to provide partial body exposure dose estimates and these were compared with those obtained from conventional dicentric assay and G0-PCC-Fragment assay (conventional G0-PCC). Dispersion analysis of aberrations from partial body exposures was carried out and compared with that of whole-body exposures. The latter was inferred from a multi-donor, wide dose range calibration curve, a-priori established for whole-body exposures. With the dispersion analysis, novel multi-parametric methodology for discerning the partial body exposure from whole body exposure and accurate dose estimation has been formulated and elucidated with the help of an example. Dose and proportion dependent reduction in sensitivity and dose estimation accuracy was observed for Dicentric assay, but not in the two PCC methods. G0-PCC-FISH was found to be most accurate for the dose estimation. G0-PCC-FISH has potential to overcome the shortcomings of current available methods and can provide rapid, accurate dose estimation of partial body and high dose accidental exposures. Biological dose estimation can be useful to predict progression of disease manifestation and can help in pre-planning of appropriate & timely medical intervention.
- 18 May 2024
- Published by Springer Nature
- p. 399-422
Biological Retrospective Dosimetry
- 18 May 2024
- Published by Springer Nature
- p. 119-142
Biological Effects of Radiation