Leixin Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Leixin Zhou has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Xiaodong Wu
Department of Electrical and Computer Engineering, University of Iowa, Iowa City, Iowa, USA
3 shared publications - Bensheng Qiu
Medical Imaging Center, Department of Electronic Engineering and Information Science, University of Science and Technology of China, Hefei, China
1 shared publication - Fahim Ahmed Zaman
Department of Electrical and Computer Engineering (F.Z., X.C., X.W.), University of Iowa
1 shared publication - John Michael Buatti
Department of Radiation Oncology, University of Iowa, Iowa City, USA
1 shared publication Wenxiang Deng
Department of ECE University of Iowa 52242 Iowa City IA USA
1 shared publication- Wenxiang Deng
Department of Electrical and Computer Engineering University of Iowa USA
1 shared publication
Latest Publications
- 8 June 2023
- Published by Springer Nature
- p. 822-834
Model-Informed Deep Learning for Surface Segmentation in Medical Imaging
- 8 June 2023
- Published by Springer Nature
- p. 822-834
Model-Informed Deep Learning for Surface Segmentation in Medical Imaging
- Open Access
Globally Optimal Surface Segmentation using Deep Learning with Learnable Smoothness Priors
Automated surface segmentation is important and challenging in many medical image analysis applications. Recent deep learning based methods have been developed for various object segmentation tasks. Most of them are a classification based approach, e.g. U-net, which predicts the probability of being target object or background for each voxel. One problem of those methods is lacking of topology guarantee for segmented objects, and usually post processing is needed to infer the boundary surface of the object. In this paper, a novel model based on convolutional neural network (CNN) followed by a learnable surface smoothing block is proposed to tackle the surface segmentation problem with end-to-end training. To the best of our knowledge, this is the first study to learn smoothness priors end-to-end with CNN for direct surface segmentation with global optimality. Experiments carried out on Spectral Domain Optical Coherence Tomography (SD-OCT) retinal layer segmentation and Intravascular Ultrasound (IVUS) vessel wall segmentation demonstrated very promising results.
Open AccessGlobally Optimal Surface Segmentation using Deep Learning with Learnable Smoothness Priors
Automated surface segmentation is important and challenging in many medical image analysis applications. Recent deep learning based methods have been developed for various object segmentation tasks. Most of them are a classification based approach, e.g. U-net, which predicts the probability of being target object or background for each voxel. One problem of those methods is lacking of topology guarantee for segmented objects, and usually post processing is needed to infer the boundary surface of the object. In this paper, a novel model based on convolutional neural network (CNN) followed by a learnable surface smoothing block is proposed to tackle the surface segmentation problem with end-to-end training. To the best of our knowledge, this is the first study to learn smoothness priors end-to-end with CNN for direct surface segmentation with global optimality. Experiments carried out on Spectral Domain Optical Coherence Tomography (SD-OCT) retinal layer segmentation and Intravascular Ultrasound (IVUS) vessel wall segmentation demonstrated very promising results.
- Open Access
Robust Image Segmentation Quality Assessment
Deep learning based image segmentation methods have achieved great success, even having human-level accuracy in some applications. However, due to the black box nature of deep learning, the best method may fail in some situations. Thus predicting segmentation quality without ground truth would be very crucial especially in clinical practice. Recently, people proposed to train neural networks to estimate the quality score by regression. Although it can achieve promising prediction accuracy, the network suffers robustness problem, e.g. it is vulnerable to adversarial attacks. In this paper, we propose to alleviate this problem by utilizing the difference between the input image and the reconstructed image, which is conditioned on the segmentation to be assessed, to lower the chance to overfit to the undesired image features from the original input image, and thus to increase the robustness. Results on ACDC17 dataset demonstrated our method is promising.
Open AccessRobust Image Segmentation Quality Assessment
Deep learning based image segmentation methods have achieved great success, even having human-level accuracy in some applications. However, due to the black box nature of deep learning, the best method may fail in some situations. Thus predicting segmentation quality without ground truth would be very crucial especially in clinical practice. Recently, people proposed to train neural networks to estimate the quality score by regression. Although it can achieve promising prediction accuracy, the network suffers robustness problem, e.g. it is vulnerable to adversarial attacks. In this paper, we propose to alleviate this problem by utilizing the difference between the input image and the reconstructed image, which is conditioned on the segmentation to be assessed, to lower the chance to overfit to the undesired image features from the original input image, and thus to increase the robustness. Results on ACDC17 dataset demonstrated our method is promising.
- Open Access
Unsupervised anomaly localization using VAE and beta-VAE
Variational Auto-Encoders (VAEs) have shown great potential in the unsupervised learning of data distributions. An VAE trained on normal images is expected to only be able to reconstruct normal images, allowing the localization of anomalous pixels in an image via manipulating information within the VAE ELBO loss. The ELBO consists of KL divergence loss (image-wise) and reconstruction loss (pixel-wise). It is natural and straightforward to use the later as the predictor. However, usually local anomaly added to a normal image can deteriorate the whole reconstructed image, causing segmentation using only naive pixel errors not accurate. Energy based projection was proposed to increase the reconstruction accuracy of normal regions/pixels, which achieved the state-of-the-art localization accuracy on simple natural images. Another possible predictors are ELBO and its components gradients with respect to each pixels. Previous work claimed that KL gradient is a robust predictor. In this paper, we argue that the energy based projection in medical imaging is not as useful as on natural images. Moreover, we observe that the robustness of KL gradient predictor totally depends on the setting of the VAE and dataset. We also explored the effect of the weight of KL loss within beta-VAE and predictor ensemble in anomaly localization.
Open AccessUnsupervised anomaly localization using VAE and beta-VAE
Variational Auto-Encoders (VAEs) have shown great potential in the unsupervised learning of data distributions. An VAE trained on normal images is expected to only be able to reconstruct normal images, allowing the localization of anomalous pixels in an image via manipulating information within the VAE ELBO loss. The ELBO consists of KL divergence loss (image-wise) and reconstruction loss (pixel-wise). It is natural and straightforward to use the later as the predictor. However, usually local anomaly added to a normal image can deteriorate the whole reconstructed image, causing segmentation using only naive pixel errors not accurate. Energy based projection was proposed to increase the reconstruction accuracy of normal regions/pixels, which achieved the state-of-the-art localization accuracy on simple natural images. Another possible predictors are ELBO and its components gradients with respect to each pixels. Previous work claimed that KL gradient is a robust predictor. In this paper, we argue that the energy based projection in medical imaging is not as useful as on natural images. Moreover, we observe that the robustness of KL gradient predictor totally depends on the setting of the VAE and dataset. We also explored the effect of the weight of KL loss within beta-VAE and predictor ensemble in anomaly localization.