Mary J. Cole
Mary J. Cole has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Paul M. W. French
Imperial College London
4 shared publications D. Parsons-Karavassilis
Department of Biological Sciences, Imperial College of Science, Technology and Medicine, London SW7 2BW, U
3 shared publications- Mael Lever
Department of Ophthalmology, University Hospital Essen, 45147 Essen, Germany
3 shared publications - Richard Jones
Boston University Boston University MIT CSAIL Boston University Boston University Red Hat Boston University Boston University Boston University
3 shared publications - Jan Siegel
Laser Processing Group, Instituto de Óptica, IO-CSIC, Serrano 121, 28006 Madrid, Spain
2 shared publications - Sandrine Lévêque-Fort
Université Paris Saclay, CNRS, Institut des Sciences Moléculaires d'Orsay, Orsay, France.
2 shared publications
Latest Publications
- Open Access
- 4 February 2025
- Published by Elsevier in American Journal of Infection Control
- Vol. 53 (5) , 659-661
Mitigating COVID-19 transmission in long-term care: A facility’s experience with dry hydrogen peroxide
- 4 February 2025
- Published by Elsevier in American Journal of Infection Control
- Vol. 53 (5) , 659-661
Open AccessMitigating COVID-19 transmission in long-term care: A facility’s experience with dry hydrogen peroxide
- Open Access
- 7 June 2023
- Published by Elsevier in American Journal of Infection Control
- Vol. 51 (12) , 1344-1349
Impact of dry hydrogen peroxide on environmental bioburden reduction in a long-term care facility
- 7 June 2023
- Published by Elsevier in American Journal of Infection Control
- Vol. 51 (12) , 1344-1349
Open AccessImpact of dry hydrogen peroxide on environmental bioburden reduction in a long-term care facility
- Open Access
- 1 April 2002
- Published by Taylor & Francis in Journal of Modern Optics
- Vol. 49 (5-6) , 985-995
Wide-field fluorescence lifetime imaging with optical sectioning and spectral resolution applied to biological samples
Wide-field fluorescence lifetime imaging with spectral resolution and optical sectioning has been performed to achieve five-dimensional fluorescence microscopy. Spectral filtering has been shown to have the potential to provide functional information about biological tissue by simultaneously measuring the spectral/lifetime signature of the sample. The potential to use multispectral imaging to separate cellular components spatially by their different emission wavelengths has also been demonstrated thus reducing artefacts in the calculated lifetime maps. The instrument is based on diode-pumped solid-state laser technology and an ultrafast gated optical image intensifier. Also reported is the use of a picosecond blue laser diode as the excitation source to produce a fluorescence lifetime microscope with a footprint of less than 0.25m2.
- 1 April 2002
- Published by Taylor & Francis in Journal of Modern Optics
- Vol. 49 (5-6) , 985-995
Open AccessWide-field fluorescence lifetime imaging with optical sectioning and spectral resolution applied to biological samples
Wide-field fluorescence lifetime imaging with spectral resolution and optical sectioning has been performed to achieve five-dimensional fluorescence microscopy. Spectral filtering has been shown to have the potential to provide functional information about biological tissue by simultaneously measuring the spectral/lifetime signature of the sample. The potential to use multispectral imaging to separate cellular components spatially by their different emission wavelengths has also been demonstrated thus reducing artefacts in the calculated lifetime maps. The instrument is based on diode-pumped solid-state laser technology and an ultrafast gated optical image intensifier. Also reported is the use of a picosecond blue laser diode as the excitation source to produce a fluorescence lifetime microscope with a footprint of less than 0.25m2.
- 2 November 2001
- Published by SPIE-Intl Soc Optical Eng
- p. 99-107
Application of the stretched exponential function to fluorescence lifetime imaging of biological tissue
The fluorescence decay in fluorescence lifetime imaging (FLIM) is typically fitted to a multi-exponential model with discrete lifetimes. The interaction between fluorophores in heterogeneous samples (e.g. biological tissue) can, however, produce complex decay characteristics that do not correspond to such models. Although they appear to provide a better fit to fluorescence decay data than the assumption of a mono-exponential decay, the assumption of multiple discrete components is essentially arbitrary and often erroneous. The stretched exponential function (StrEF) describes fluorescence decay profiles using a continuous lifetime distribution as has been reported for tryptophan, being one of the main fluorophores in tissue. We have demonstrated that this model represents our time-domain FLIM data better than multi-exponential discrete decay components, yielding excellent contrast in tissue discrimination without compromising the goodness of fit, and it significantly decreases the required processing time. In addition, the stretched exponential decay model can provide a direct measure of the sample heterogeneity and the resulting heterogeneity map can reveal subtle tissue differences that other models fail to show.
- 2 November 2001
- Published by SPIE-Intl Soc Optical Eng
- p. 99-107
Application of the stretched exponential function to fluorescence lifetime imaging of biological tissue
The fluorescence decay in fluorescence lifetime imaging (FLIM) is typically fitted to a multi-exponential model with discrete lifetimes. The interaction between fluorophores in heterogeneous samples (e.g. biological tissue) can, however, produce complex decay characteristics that do not correspond to such models. Although they appear to provide a better fit to fluorescence decay data than the assumption of a mono-exponential decay, the assumption of multiple discrete components is essentially arbitrary and often erroneous. The stretched exponential function (StrEF) describes fluorescence decay profiles using a continuous lifetime distribution as has been reported for tryptophan, being one of the main fluorophores in tissue. We have demonstrated that this model represents our time-domain FLIM data better than multi-exponential discrete decay components, yielding excellent contrast in tissue discrimination without compromising the goodness of fit, and it significantly decreases the required processing time. In addition, the stretched exponential decay model can provide a direct measure of the sample heterogeneity and the resulting heterogeneity map can reveal subtle tissue differences that other models fail to show.
- 1 March 2000
- Published by Elsevier in Optics Communications
- Vol. 175 (4-6) , 389-396
Diode-pumped all-solid-state ultrafast Cr:LiSGAF laser oscillator–amplifier system applied to laser ablation
- 1 March 2000
- Published by Elsevier in Optics Communications
- Vol. 175 (4-6) , 389-396
Diode-pumped all-solid-state ultrafast Cr:LiSGAF laser oscillator–amplifier system applied to laser ablation
- 18 February 1999
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 35 (4) , 256-258
Fluorescence lifetime imaging using a diode-pumpedall-solid-state lasersystem
A whole-field fluorescence lifetime imaging system is presented which is based, for the first time, on an all-solid-state diode-pumped oscillator/amplifier system. Fluorescence lifetime imaging of unstained biological tissue in vitro using this instrument demonstrated contrast between different tissue constituents.
- 18 February 1999
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 35 (4) , 256-258
Fluorescence lifetime imaging using a diode-pumpedall-solid-state lasersystem
A whole-field fluorescence lifetime imaging system is presented which is based, for the first time, on an all-solid-state diode-pumped oscillator/amplifier system. Fluorescence lifetime imaging of unstained biological tissue in vitro using this instrument demonstrated contrast between different tissue constituents.