Yüksel Özbay
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yüksel Özbay has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Gülay Tezel
Computer Engineering Department, Selcuk, University, Konya, Turkey
2 shared publications Murat Ceylan
Selcuk University, Department of Electronics Engineering, 42075 Konya, Turkey
2 shared publications- Murat Ceylan
Selcuk University
2 shared publications Rahime Ceylan
Selcuk University, Department of Electronics Engineering, 42075 Konya, Turkey
2 shared publications- Sadık Kara
Institute of Biomedical Engineering, Fatih University, Istanbul, Turkey
2 shared publications - Ahmet Reşit Kavsaoğlu
Karabük Üniversitesi, Mühendislik Fakültesi
1 shared publication
Latest Publications
- 31 December 2011
- Published by Elsevier in Expert Systems with Applications
- Vol. 38 (12) , 15595-15598
Corrigendum to “Fuzzy clustering complex-valued neural network to diagnose cirrhosis disease” [Expert Systems with Applications 38 (2011) 9744–9751]
- 31 December 2011
- Published by Elsevier in Expert Systems with Applications
- Vol. 38 (12) , 15595-15598
Corrigendum to “Fuzzy clustering complex-valued neural network to diagnose cirrhosis disease” [Expert Systems with Applications 38 (2011) 9744–9751]
- 1 January 2010
- Published by Elsevier in Digital Signal Processing
- Vol. 20 (1) , 133-148
An optimum algorithm for adaptive filtering on acoustic echo cancellation using TMS320C6713 DSP
- 1 January 2010
- Published by Elsevier in Digital Signal Processing
- Vol. 20 (1) , 133-148
An optimum algorithm for adaptive filtering on acoustic echo cancellation using TMS320C6713 DSP
- 1 January 2010
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in Turkish Journal of Electrical Engineering and Computer Sciences
- Vol. 18 (4) , 613-624
A novel method for lung segmentation on chest CT images: complex-valued artificial neural network with complex wavelet transform
Image segmentation is an important step in many computer vision algorithms. The objective of segmentation is to obtained an optimal region of convergences (ROC). Error in this stage will impact all higher level activities. This paper focuses on a new efficient method denoted as Complex-Valued Artificial Neural Network with Complex Wavelet Transform (CWT-CVANN) for the segmentation of lung region on chest CT images. In this combined architecture is composed of two cascade stages: feature extraction with various levels of complex wavelet transform and segmentation with complex-valued artificial neural network. Here, 32 CT images of 6 female and 26 male patients were recorded from Baskent University Radiology Department. (This collection includes 10 images with benign nodules and 22 images with malign nodules. Averaged age of patients is 64. Each CT slice used in this study has dimensions of 752\times 752 pixels with grey level) In only two seconds of processing time per each CT image, 99.79% averaged accuracy rate is obtained using 3^{rd} level CWT-CVANN for segmentation of the lung region. Thus, it is concluded that CWT-CVANN is a comprising method in lung region segmentation problem.
- 1 January 2010
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in Turkish Journal of Electrical Engineering and Computer Sciences
- Vol. 18 (4) , 613-624
A novel method for lung segmentation on chest CT images: complex-valued artificial neural network with complex wavelet transform
Image segmentation is an important step in many computer vision algorithms. The objective of segmentation is to obtained an optimal region of convergences (ROC). Error in this stage will impact all higher level activities. This paper focuses on a new efficient method denoted as Complex-Valued Artificial Neural Network with Complex Wavelet Transform (CWT-CVANN) for the segmentation of lung region on chest CT images. In this combined architecture is composed of two cascade stages: feature extraction with various levels of complex wavelet transform and segmentation with complex-valued artificial neural network. Here, 32 CT images of 6 female and 26 male patients were recorded from Baskent University Radiology Department. (This collection includes 10 images with benign nodules and 22 images with malign nodules. Averaged age of patients is 64. Each CT slice used in this study has dimensions of 752\times 752 pixels with grey level) In only two seconds of processing time per each CT image, 99.79% averaged accuracy rate is obtained using 3^{rd} level CWT-CVANN for segmentation of the lung region. Thus, it is concluded that CWT-CVANN is a comprising method in lung region segmentation problem.
- 31 January 2009
- Published by Elsevier in Expert Systems with Applications
- Vol. 36 (1) , 172-180
A new approach for epileptic seizure detection using adaptive neural network
- 31 January 2009
- Published by Elsevier in Expert Systems with Applications
- Vol. 36 (1) , 172-180
A new approach for epileptic seizure detection using adaptive neural network
- 4 September 2008
- Published by Springer Nature in Journal of Medical Systems
- Vol. 33 (6) , 435-445
A New Approach to Detection of ECG Arrhythmias: Complex Discrete Wavelet Transform Based Complex Valued Artificial Neural Network
This paper presents the new automated detection method for electrocardiogram (ECG) arrhythmias. The detection system is implemented with integration of complex valued feature extraction and classification parts. In feature extraction phase of proposed method, the feature values for each arrhythmia are extracted using complex discrete wavelet transform (CWT). The aim of using CWT is to compress data and to reduce training time of network without decreasing accuracy rate. Obtained complex valued features are used as input to the complex valued artificial neural network (CVANN) for classification of ECG arrhythmias. Ten types of the ECG arrhythmias used in this study were selected from MIT-BIH ECG Arrhythmias Database. Two different classification tasks were performed by the proposed method. In first classification task (CT-1), whether CWT-CVANN can distinguish ECG arrhythmia from normal sinus rhythm was examined one by one. For this purpose, nine classifiers were improved and executed in CT-1. Second classification task (CT-2) was to recognize ten different ECG arrhythmias by one complex valued classifier with ten outputs. Training and test sets were formed by mixing the arrhythmias in a certain order. Accuracy rates were obtained as 99.8% (averaged) and 99.2% for the first and second classification tasks, respectively. All arrhythmias in training and test phases were classified correctly for both of the classification tasks.
- 4 September 2008
- Published by Springer Nature in Journal of Medical Systems
- Vol. 33 (6) , 435-445
A New Approach to Detection of ECG Arrhythmias: Complex Discrete Wavelet Transform Based Complex Valued Artificial Neural Network
This paper presents the new automated detection method for electrocardiogram (ECG) arrhythmias. The detection system is implemented with integration of complex valued feature extraction and classification parts. In feature extraction phase of proposed method, the feature values for each arrhythmia are extracted using complex discrete wavelet transform (CWT). The aim of using CWT is to compress data and to reduce training time of network without decreasing accuracy rate. Obtained complex valued features are used as input to the complex valued artificial neural network (CVANN) for classification of ECG arrhythmias. Ten types of the ECG arrhythmias used in this study were selected from MIT-BIH ECG Arrhythmias Database. Two different classification tasks were performed by the proposed method. In first classification task (CT-1), whether CWT-CVANN can distinguish ECG arrhythmia from normal sinus rhythm was examined one by one. For this purpose, nine classifiers were improved and executed in CT-1. Second classification task (CT-2) was to recognize ten different ECG arrhythmias by one complex valued classifier with ten outputs. Training and test sets were formed by mixing the arrhythmias in a certain order. Accuracy rates were obtained as 99.8% (averaged) and 99.2% for the first and second classification tasks, respectively. All arrhythmias in training and test phases were classified correctly for both of the classification tasks.
- 2 April 2008
- Published by Springer Nature in Journal of Medical Systems
- Vol. 32 (5) , 369-377
A New Method for Diagnosis of Cirrhosis Disease: Complex-valued Artificial Neural Network
In this study, complex-valued artificial neural network (CVANN) that is a new technique for biomedical pattern classification was proposed for classifying portal vein Doppler signals recorded from 54 patients with cirrhosis and 36 healthy subjects. Fast Fourier transform values of Doppler signals were calculated for pre-processing and obtained values, which include real and imaginary components, were used as the inputs of the CVANN for classification of Doppler signals. Classification results of CVANN show that Doppler signals were classified successfully with 100% correct classification rate using leave-one-out cross-validation. Besides, CVANN has 100% sensitivity and 100% specificity. These results were found to be compliant with the expected results that are derived from physician’s direct diagnosis. This method would be to assist the physician to make the final decision.
- 2 April 2008
- Published by Springer Nature in Journal of Medical Systems
- Vol. 32 (5) , 369-377
A New Method for Diagnosis of Cirrhosis Disease: Complex-valued Artificial Neural Network
In this study, complex-valued artificial neural network (CVANN) that is a new technique for biomedical pattern classification was proposed for classifying portal vein Doppler signals recorded from 54 patients with cirrhosis and 36 healthy subjects. Fast Fourier transform values of Doppler signals were calculated for pre-processing and obtained values, which include real and imaginary components, were used as the inputs of the CVANN for classification of Doppler signals. Classification results of CVANN show that Doppler signals were classified successfully with 100% correct classification rate using leave-one-out cross-validation. Besides, CVANN has 100% sensitivity and 100% specificity. These results were found to be compliant with the expected results that are derived from physician’s direct diagnosis. This method would be to assist the physician to make the final decision.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A New Approach for Classification of EEG Signals
This study presents a comparative study of the classification accuracy and speed of performance of epileptic Electroensefalogram (EEG) signals using a traditional neural network architecture based on backpropagation training algorithm, and a new neural network. The proposed network is called adaptive neural network with activation function (AAF-NN) in which adjustable parameters, It is used two different activation functions for developed study. One of theese adaptive activation functions is sigmoid function with free parameters and the other one is sum of sinusoidal function with free parameters and sigmoid function with free parameters. The adaptive activation function with free parameters is used in the hidden layer for the proposed structures based on the feed-forward neural network Experimental results have revealed that neural network with adaptive activation function is more suitable for classification EEG signals and training speed is much faster than traditional neural network with fixed sigmoid activation function.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A New Approach for Classification of EEG Signals
This study presents a comparative study of the classification accuracy and speed of performance of epileptic Electroensefalogram (EEG) signals using a traditional neural network architecture based on backpropagation training algorithm, and a new neural network. The proposed network is called adaptive neural network with activation function (AAF-NN) in which adjustable parameters, It is used two different activation functions for developed study. One of theese adaptive activation functions is sigmoid function with free parameters and the other one is sum of sinusoidal function with free parameters and sigmoid function with free parameters. The adaptive activation function with free parameters is used in the hidden layer for the proposed structures based on the feed-forward neural network Experimental results have revealed that neural network with adaptive activation function is more suitable for classification EEG signals and training speed is much faster than traditional neural network with fixed sigmoid activation function.
- 2 April 2007
- Published by Elsevier in Artificial Intelligence in Medicine
- Vol. 40 (2) , 143-156
Complex-valued wavelet artificial neural network for Doppler signals classifying
- 2 April 2007
- Published by Elsevier in Artificial Intelligence in Medicine
- Vol. 40 (2) , 143-156
Complex-valued wavelet artificial neural network for Doppler signals classifying
- 1 March 2007
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 37 (3) , 287-295
Effects of window types on classification of carotid artery Doppler signals in the early phase of atherosclerosis using complex-valued artificial neural network
- 1 March 2007
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 37 (3) , 287-295
Effects of window types on classification of carotid artery Doppler signals in the early phase of atherosclerosis using complex-valued artificial neural network
- 1 April 2006
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 36 (4) , 376-388
A fuzzy clustering neural network architecture for classification of ECG arrhythmias
- 1 April 2006
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 36 (4) , 376-388
A fuzzy clustering neural network architecture for classification of ECG arrhythmias