Annelise E. Barron
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Annelise E. Barron has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
Erin A. S. Doherty
Department of Chemical and Biological Engineering, Northwestern University, Evanston, IL, USA
4 shared publicationsBrett A. Buchholz
Department of Chemical and Biological Engineering, Northwestern University, Evanston, IL, USA
3 shared publicationsCheuk Wai Kan
Department of Chemical and Biological Engineering, Northwestern University, Evanston, IL, USA
3 shared publications- Robert J. Meagher
Sandia National Laboratories
3 shared publications Ronald N. Zuckermann
Chiron Technologies, Chiron Corporation, Emeryville, California 94608
3 shared publicationsCheuk‐Wai Kan
Department of Chemical and Biological Engineering, Northwestern University, Evanston, IL 60208, USA
2 shared publications
Latest Publications
- 9 October 2006
- Published by Wiley in Electrophoresis
- Vol. 27 (19) , 3823-3835
An optimized microchip electrophoresis system for mutation detection by tandem SSCP and heteroduplex analysis for p53 gene exons 5–9
With the complete sequencing of the human genome, there is a growing need for rapid, highly sensitive genetic mutation detection methods suitable for clinical implementation. DNA‐based diagnostics such as single‐strand conformational polymorphism (SSCP) and heteroduplex analysis (HA) are commonly used in research laboratories to screen for mutations, but the slab gel electrophoresis (SGE) format is ill‐suited for routine clinical use. The translation of these assays from SGE to microfluidic chips offers significant speed, cost, and sensitivity advantages; however, numerous parameters must be optimized to provide highly sensitive mutation detection. Here we present a methodical study of system parameters including polymer matrix, wall coating, analysis temperature, and electric field strengths on the effectiveness of mutation detection by tandem SSCP/HA for DNA samples from exons 5–9 of the p53 gene. The effects of polymer matrix concentration and average molar mass were studied for linear polyacrylamide (LPA) solutions. We determined that a matrix of 8% w/v 600 kDa LPA provides the most reliable SSCP/HA mutation detection on chips. The inclusion of a small amount of the dynamic wall‐coating polymer poly‐N‐hydroxyethylacrylamide in the matrix substantially improves the resolution of SSCP conformers and extends the coating lifetime. We investigated electrophoresis temperatures between 17 and 35°C and found that the lowest temperature accessible on our chip electrophoresis system gives the best condition for high sensitivity of the tandem SSCP/HA method, especially for the SSCP conformers. Finally, the use of electrical fields between 350 and 450 V/cm provided rapid separations (<10 min) with well‐resolved DNA peaks for both SSCP and HA.
- 9 October 2006
- Published by Wiley in Electrophoresis
- Vol. 27 (19) , 3823-3835
An optimized microchip electrophoresis system for mutation detection by tandem SSCP and heteroduplex analysis for p53 gene exons 5–9
With the complete sequencing of the human genome, there is a growing need for rapid, highly sensitive genetic mutation detection methods suitable for clinical implementation. DNA‐based diagnostics such as single‐strand conformational polymorphism (SSCP) and heteroduplex analysis (HA) are commonly used in research laboratories to screen for mutations, but the slab gel electrophoresis (SGE) format is ill‐suited for routine clinical use. The translation of these assays from SGE to microfluidic chips offers significant speed, cost, and sensitivity advantages; however, numerous parameters must be optimized to provide highly sensitive mutation detection. Here we present a methodical study of system parameters including polymer matrix, wall coating, analysis temperature, and electric field strengths on the effectiveness of mutation detection by tandem SSCP/HA for DNA samples from exons 5–9 of the p53 gene. The effects of polymer matrix concentration and average molar mass were studied for linear polyacrylamide (LPA) solutions. We determined that a matrix of 8% w/v 600 kDa LPA provides the most reliable SSCP/HA mutation detection on chips. The inclusion of a small amount of the dynamic wall‐coating polymer poly‐N‐hydroxyethylacrylamide in the matrix substantially improves the resolution of SSCP conformers and extends the coating lifetime. We investigated electrophoresis temperatures between 17 and 35°C and found that the lowest temperature accessible on our chip electrophoresis system gives the best condition for high sensitivity of the tandem SSCP/HA method, especially for the SSCP conformers. Finally, the use of electrical fields between 350 and 450 V/cm provided rapid separations (<10 min) with well‐resolved DNA peaks for both SSCP and HA.
- 20 May 2006
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (13) , 4409-4415
Self-Associating Block Copolymer Networks for Microchip Electrophoresis Provide Enhanced DNA Separation via “Inchworm” Chain Dynamics
We describe a novel class of DNA separation media for microchip electrophoresis, “physically cross-linked” block copolymer networks, which provide rapid (co-dihexylacrylamide) (LPA-co-DHA) comprising as little as 0.13 mol % dihexylacrylamide yields substantially improved electrophoretic DNA separations compared to matched molar mass linear polyacrylamide. Single-molecule videomicroscopic images of DNA electrophoresis reveal novel chain dynamics in LPA-co-DHA matrixes, resembling inchworm movement, to which we attribute the increased DNA resolution. Substantial improvements in DNA peak separation are obtained, in particular, in LPA-co-DHA solutions at polymer/copolymer concentrations near the interchain entanglement threshold. Higher polymer concentrations yield enhanced separations only for small DNA molecules (<120 base pairs). Hydrophobically cross-linked networks offer advantages over conventional linear polymers based on enhanced separation performance (or speed) and over chemically cross-linked gels because hydrophobic cross-links can be reversibly broken, allowing facile microchannel loading.
- 20 May 2006
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (13) , 4409-4415
Self-Associating Block Copolymer Networks for Microchip Electrophoresis Provide Enhanced DNA Separation via “Inchworm” Chain Dynamics
We describe a novel class of DNA separation media for microchip electrophoresis, “physically cross-linked” block copolymer networks, which provide rapid (co-dihexylacrylamide) (LPA-co-DHA) comprising as little as 0.13 mol % dihexylacrylamide yields substantially improved electrophoretic DNA separations compared to matched molar mass linear polyacrylamide. Single-molecule videomicroscopic images of DNA electrophoresis reveal novel chain dynamics in LPA-co-DHA matrixes, resembling inchworm movement, to which we attribute the increased DNA resolution. Substantial improvements in DNA peak separation are obtained, in particular, in LPA-co-DHA solutions at polymer/copolymer concentrations near the interchain entanglement threshold. Higher polymer concentrations yield enhanced separations only for small DNA molecules (<120 base pairs). Hydrophobically cross-linked networks offer advantages over conventional linear polymers based on enhanced separation performance (or speed) and over chemically cross-linked gels because hydrophobic cross-links can be reversibly broken, allowing facile microchannel loading.
- 27 April 2006
- Published by Wiley in Electrophoresis
- Vol. 27 (9) , 1702-1712
Free‐solution electrophoresis of DNA modified with drag‐tags at both ends
In end‐labeled free‐solution electrophoresis (ELFSE), DNA molecules are labeled with a frictional modifier or “drag‐tag”, allowing their size‐based electrophoretic separation in free solution. Among the interesting observations from early work with dsDNA using streptavidin as a drag‐tag was that the drag induced by including a streptavidin label at both ends was significantly more than double that from a single streptavidin (Heller, C. et al.., J. Chromatogr. A 1998, 806, 113–121). This finding was assumed to be in error, and subsequent work focused on experiments in which only a single drag‐tag is appended to one end of the DNA molecule. Recent theoretical work (McCormick, L. C., Slater, G. W., Electrophoresis 2005, 26, 1659–1667) has examined the contribution of end‐effects to the free‐solution electrophoretic mobility of charged‐uncharged polymer conjugates, reopening the question of enhanced drag from placing a drag‐tag at both ends. In this study, this effect is investigated experimentally, using custom‐synthesized ssDNA oligonucleotides allowing the attachment of drag‐tags to one or both ends, as well as dsDNA PCR products generated with primers appropriate for the attachment of drag‐tags at one or both ends. A range of sizes of drag‐tags are used, including synthetic polypeptoid drag‐tags as well as genetically engineered protein polymer drag‐tags. The enhanced drag arising from labeling both ends has been confirmed, with 6–9% additional drag for the ssDNA and 10–23% additional drag for the dsDNA arising from labeling both ends than would be expected from simply doubling the size of the drag‐tag at one end. The experimental results for ssDNA labeled at both ends are compared to the predictions of the recent theory of end‐effects, with reasonably good quantitative agreement. These experimental findings demonstrate the feasibility of enhancing ELFSE separations by labeling both ends of the DNA molecule, leading to greater resolving power and a wider range of applications for this technique.
- 27 April 2006
- Published by Wiley in Electrophoresis
- Vol. 27 (9) , 1702-1712
Free‐solution electrophoresis of DNA modified with drag‐tags at both ends
In end‐labeled free‐solution electrophoresis (ELFSE), DNA molecules are labeled with a frictional modifier or “drag‐tag”, allowing their size‐based electrophoretic separation in free solution. Among the interesting observations from early work with dsDNA using streptavidin as a drag‐tag was that the drag induced by including a streptavidin label at both ends was significantly more than double that from a single streptavidin (Heller, C. et al.., J. Chromatogr. A 1998, 806, 113–121). This finding was assumed to be in error, and subsequent work focused on experiments in which only a single drag‐tag is appended to one end of the DNA molecule. Recent theoretical work (McCormick, L. C., Slater, G. W., Electrophoresis 2005, 26, 1659–1667) has examined the contribution of end‐effects to the free‐solution electrophoretic mobility of charged‐uncharged polymer conjugates, reopening the question of enhanced drag from placing a drag‐tag at both ends. In this study, this effect is investigated experimentally, using custom‐synthesized ssDNA oligonucleotides allowing the attachment of drag‐tags to one or both ends, as well as dsDNA PCR products generated with primers appropriate for the attachment of drag‐tags at one or both ends. A range of sizes of drag‐tags are used, including synthetic polypeptoid drag‐tags as well as genetically engineered protein polymer drag‐tags. The enhanced drag arising from labeling both ends has been confirmed, with 6–9% additional drag for the ssDNA and 10–23% additional drag for the dsDNA arising from labeling both ends than would be expected from simply doubling the size of the drag‐tag at one end. The experimental results for ssDNA labeled at both ends are compared to the predictions of the recent theory of end‐effects, with reasonably good quantitative agreement. These experimental findings demonstrate the feasibility of enhancing ELFSE separations by labeling both ends of the DNA molecule, leading to greater resolving power and a wider range of applications for this technique.
- 14 January 2006
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 128 (5) , 1733-1738
A Threaded Loop Conformation Adopted by a Family of Peptoid Nonamers
Non-natural polymers with well-defined three-dimensional folds offer considerable potential for engineering novel functions that are outside the scope of biological polymers. Here we describe a family of N-substituted glycine or “peptoid” nonamers that folds into an unusual “threaded loop” structure of exceptional thermal stability and conformational homogeneity in acetonitrile. The structure is chain-length-specific and relies on bulky, chiral side chains and chain-terminating functional groups for stability. Notable elements of the structure include the engagement of the positively charged amino terminus by carbonyl groups of the backbone through hydrogen bonding interactions and shielding of polar groups from and near-complete exposure of hydrophobic groups to solvent, in a manner resembling a folded polypeptide globular domain turned inside-out. The structure is stable in a variety of organic solvents but is readily denatured in any solvent/cosolvent milieu with hydrogen bonding potential. The structure could serve as a scaffold for the elaboration of novel functions and could be used to test methodologies for predicting solvent-dependent polymer folding.
- 14 January 2006
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 128 (5) , 1733-1738
A Threaded Loop Conformation Adopted by a Family of Peptoid Nonamers
Non-natural polymers with well-defined three-dimensional folds offer considerable potential for engineering novel functions that are outside the scope of biological polymers. Here we describe a family of N-substituted glycine or “peptoid” nonamers that folds into an unusual “threaded loop” structure of exceptional thermal stability and conformational homogeneity in acetonitrile. The structure is chain-length-specific and relies on bulky, chiral side chains and chain-terminating functional groups for stability. Notable elements of the structure include the engagement of the positively charged amino terminus by carbonyl groups of the backbone through hydrogen bonding interactions and shielding of polar groups from and near-complete exposure of hydrophobic groups to solvent, in a manner resembling a folded polypeptide globular domain turned inside-out. The structure is stable in a variety of organic solvents but is readily denatured in any solvent/cosolvent milieu with hydrogen bonding potential. The structure could serve as a scaffold for the elaboration of novel functions and could be used to test methodologies for predicting solvent-dependent polymer folding.
- 27 May 2005
- Published by Wiley in Electrophoresis
- Vol. 26 (11) , 2138-2148
Protein polymer drag-tags for DNA separations by end-labeled free-solution electrophoresis
- 27 May 2005
- Published by Wiley in Electrophoresis
- Vol. 26 (11) , 2138-2148
Protein polymer drag-tags for DNA separations by end-labeled free-solution electrophoresis
- 13 April 2004
- Published by Wiley in Electrophoresis
- Vol. 25 (7-8) , 1007-1015
Thermoresponsive N,N‐dialkylacrylamide copolymer blends as DNA sieving matrices with a thermally tunable mesh size
In an earlier study we showed that a blend of thermoresponsive and nonthermoresponsive hydroxyalkylcelluloses could be used to create a thermally tunable polymer network for double-stranded (ds) DNA separation. Here, we show the generality of this approach using a family of polymers suited to a wider range of DNA separations: a blended mixture of N,N-dialkylacrylamide copolymers with different thermoresponsive behaviors. A mixture of 47% w/w N,N-diethylacrylamide (DEA)/53% w/w N,N-dimethylacrylamide (DMA) (DEA47; thermoresponsive, transition temperature = 55°C in water) and 30% w/w DEA/70% w/w DMA (DEA30; nonthermoresponsive, transition temperature > 85°C in water) copolymers in the ratio of 1:5 w/w DEA47:DEA30 was used to separate a dsDNA restriction digest (ΦX174-HaeIII). We investigated the effects of changing mesh size on dsDNA separation, as controlled by temperature. We observed good DNA separation performance with the copolymer blend at temperatures ranging from 25°C to 48°C. The separation selectivity was evaluated quantitatively for certain DNA fragment pairs as a function of temperature. The results were compared with those obtained with a control matrix consisting only of the nonthermoresponsive DEA30. Different DNA fragment pairs of various sizes show distinct temperature-dependent selectivities. Over the same temperature range, no significant temperature dependence of selectivity is observed for these DNA fragment pairs in the nonthermoresponsive control matrix. Overall, the results show similar trends in the temperature dependency of separation selectivity to what was previously observed in hydroxyalkylcellulose blends, for the same DNA fragment pairs. Finally, we showed that a ramped temperature scheme enables improved separation in the blended copolymer matrix for both small and large DNA fragments, simultaneously in a single capillary electrophoresis (CE) run.
- 13 April 2004
- Published by Wiley in Electrophoresis
- Vol. 25 (7-8) , 1007-1015
Thermoresponsive N,N‐dialkylacrylamide copolymer blends as DNA sieving matrices with a thermally tunable mesh size
In an earlier study we showed that a blend of thermoresponsive and nonthermoresponsive hydroxyalkylcelluloses could be used to create a thermally tunable polymer network for double-stranded (ds) DNA separation. Here, we show the generality of this approach using a family of polymers suited to a wider range of DNA separations: a blended mixture of N,N-dialkylacrylamide copolymers with different thermoresponsive behaviors. A mixture of 47% w/w N,N-diethylacrylamide (DEA)/53% w/w N,N-dimethylacrylamide (DMA) (DEA47; thermoresponsive, transition temperature = 55°C in water) and 30% w/w DEA/70% w/w DMA (DEA30; nonthermoresponsive, transition temperature > 85°C in water) copolymers in the ratio of 1:5 w/w DEA47:DEA30 was used to separate a dsDNA restriction digest (ΦX174-HaeIII). We investigated the effects of changing mesh size on dsDNA separation, as controlled by temperature. We observed good DNA separation performance with the copolymer blend at temperatures ranging from 25°C to 48°C. The separation selectivity was evaluated quantitatively for certain DNA fragment pairs as a function of temperature. The results were compared with those obtained with a control matrix consisting only of the nonthermoresponsive DEA30. Different DNA fragment pairs of various sizes show distinct temperature-dependent selectivities. Over the same temperature range, no significant temperature dependence of selectivity is observed for these DNA fragment pairs in the nonthermoresponsive control matrix. Overall, the results show similar trends in the temperature dependency of separation selectivity to what was previously observed in hydroxyalkylcellulose blends, for the same DNA fragment pairs. Finally, we showed that a ramped temperature scheme enables improved separation in the blended copolymer matrix for both small and large DNA fragments, simultaneously in a single capillary electrophoresis (CE) run.
- 17 February 2004
- Published by Wiley
- p. 1-31
Versatile Oligo( N ‐Substituted) Glycines: The Many Roles of Peptoids in Drug Discovery
- 17 February 2004
- Published by Wiley
- p. 1-31
Versatile Oligo( N ‐Substituted) Glycines: The Many Roles of Peptoids in Drug Discovery
- 29 January 2004
- Published by Wiley in Electrophoresis
- Vol. 25 (3) , 405-414
A very thin coating for capillary zone electrophoresis of proteins based on a tri(ethylene glycol)‐terminated alkyltrichlorosilane
We describe the use of a tri(ethylene glycol)-terminated alkyltrichlorosilane to create a very thin, protein-resistant “self-assembled monolayer” coating on the inner surface of a fused-silica capillary. The same compound has been demonstrated previously on flat silica substrates to resist adsorption of many proteins. As a covalently bound capillary coating, it displays good resistance to the adsorption of cationic proteins, providing clean separations of a mixture of lysozyme, cytochrome c, ribonuclease A, and myoglobin for more than 200 consecutive runs. Electroosmotic flow (EOF) was measured as a function of pH; the coated capillary retains significant cathodal EOF, with roughly 50% of the EOF of an uncoated capillary at neutral pH, making this coating promising for applications requiring some EOF. The EOF was reasonably stable, with a 2.9% relative standard deviation during a 24 h period consisting of 72 consecutive separations of cationic proteins. Efficiencies for cationic protein separations were moderate, in the range of 190 000–290 000 theoretical plates per meter. The coating procedure was simple, requiring only a standard cleaning procedure followed by a rinse with the silane reagent at room temperature. No buffer additives are required to maintain the stability of the coating, making it flexible for a range of applications, potentially including capillary electrophoresis-mass spectrometry (CE-MS).
- 29 January 2004
- Published by Wiley in Electrophoresis
- Vol. 25 (3) , 405-414
A very thin coating for capillary zone electrophoresis of proteins based on a tri(ethylene glycol)‐terminated alkyltrichlorosilane
We describe the use of a tri(ethylene glycol)-terminated alkyltrichlorosilane to create a very thin, protein-resistant “self-assembled monolayer” coating on the inner surface of a fused-silica capillary. The same compound has been demonstrated previously on flat silica substrates to resist adsorption of many proteins. As a covalently bound capillary coating, it displays good resistance to the adsorption of cationic proteins, providing clean separations of a mixture of lysozyme, cytochrome c, ribonuclease A, and myoglobin for more than 200 consecutive runs. Electroosmotic flow (EOF) was measured as a function of pH; the coated capillary retains significant cathodal EOF, with roughly 50% of the EOF of an uncoated capillary at neutral pH, making this coating promising for applications requiring some EOF. The EOF was reasonably stable, with a 2.9% relative standard deviation during a 24 h period consisting of 72 consecutive separations of cationic proteins. Efficiencies for cationic protein separations were moderate, in the range of 190 000–290 000 theoretical plates per meter. The coating procedure was simple, requiring only a standard cleaning procedure followed by a rinse with the silane reagent at room temperature. No buffer additives are required to maintain the stability of the coating, making it flexible for a range of applications, potentially including capillary electrophoresis-mass spectrometry (CE-MS).
- 12 December 2003
- Published by Wiley in Electrophoresis
- Vol. 24 (24) , 4170-4180
Sparsely cross-linked“nanogels” for microchannel DNA sequencing
We have developed sparsely cross-linked “nanogels”, sub-colloidal polymer structures composed of covalently linked, linear polyacrylamide chains, as novel DNA sequencing matrices for capillary electrophoresis. The presence of covalent cross-links affords nanogel matrices with enhanced network stability relative to standard, linear polyacrylamide (LPA), improving the separation of large DNA fragments. Nanogels were synthesized via inverse emulsion (water-in-oil) copolymerization of acrylamide and N,N-methylenebisacrylamide (Bis). In order to retain the fluidity necessary in a replaceable polymer matrix for capillary array electrophoresis (CAE), a low percentage of the Bis cross-linker (< 10−4 mol%) was used. Nanogels were characterized by multiangle laser light scattering and rheometry, and were tested for DNA sequencing by CAE with four-color laser-induced fluorescence (LIF) detection. The properties and performance of nanogel matrices were compared to those of a commercially available LPA network, which was matched for both weight-average molar mass (Mw) and extent of interchain entanglements (c/c*). Nanogels presented in this work have an average radius of gyration of 226 nm and a weight-average molar mass of 8.8×106 g/mol. At concentrations above the overlap threshold, nanogels form a clear, viscous solution, similar to the LPA matrix (Mw ∼ 8.9×106 g/mol). The two matrices have similar flow and viscosity characteristics. However, because of the physical network stability provided by the internally cross-linked structure of the nanogels, a substantially longer read length (∼ 63 bases, a 10.4% improvement) is obtained with the nanogel matrix at 98.5% accuracy of base-calling. The nanogel network provides higher-selectivity separation of ssDNA sequencing fragments longer than 375 bases. Moreover, nanogel matrices require 30% less polymer per unit volume than LPA. This is the first report of a sequencing matrix that provides better performance than LPA, in a side-by-side comparison of polymer matrices matched for Mw and extent of interchain entanglements.
- 12 December 2003
- Published by Wiley in Electrophoresis
- Vol. 24 (24) , 4170-4180
Sparsely cross-linked“nanogels” for microchannel DNA sequencing
We have developed sparsely cross-linked “nanogels”, sub-colloidal polymer structures composed of covalently linked, linear polyacrylamide chains, as novel DNA sequencing matrices for capillary electrophoresis. The presence of covalent cross-links affords nanogel matrices with enhanced network stability relative to standard, linear polyacrylamide (LPA), improving the separation of large DNA fragments. Nanogels were synthesized via inverse emulsion (water-in-oil) copolymerization of acrylamide and N,N-methylenebisacrylamide (Bis). In order to retain the fluidity necessary in a replaceable polymer matrix for capillary array electrophoresis (CAE), a low percentage of the Bis cross-linker (< 10−4 mol%) was used. Nanogels were characterized by multiangle laser light scattering and rheometry, and were tested for DNA sequencing by CAE with four-color laser-induced fluorescence (LIF) detection. The properties and performance of nanogel matrices were compared to those of a commercially available LPA network, which was matched for both weight-average molar mass (Mw) and extent of interchain entanglements (c/c*). Nanogels presented in this work have an average radius of gyration of 226 nm and a weight-average molar mass of 8.8×106 g/mol. At concentrations above the overlap threshold, nanogels form a clear, viscous solution, similar to the LPA matrix (Mw ∼ 8.9×106 g/mol). The two matrices have similar flow and viscosity characteristics. However, because of the physical network stability provided by the internally cross-linked structure of the nanogels, a substantially longer read length (∼ 63 bases, a 10.4% improvement) is obtained with the nanogel matrix at 98.5% accuracy of base-calling. The nanogel network provides higher-selectivity separation of ssDNA sequencing fragments longer than 375 bases. Moreover, nanogel matrices require 30% less polymer per unit volume than LPA. This is the first report of a sequencing matrix that provides better performance than LPA, in a side-by-side comparison of polymer matrices matched for Mw and extent of interchain entanglements.
- 12 December 2003
- Published by Wiley in Electrophoresis
- Vol. 24 (24) , 4161-4169
A novel thermogelling matrix for microchannel DNA sequencing based on poly‐N‐alkoxyalkylacrylamide copolymers
We have developed a novel class of thermogelling polymer networks based on poly‐N‐alkoxyalkylacrylamides, and demonstrated their use as DNA sequencing matrices for high‐throughput microchannel electrophoresis in capillary arrays. Polymers and copolymers of N‐ethoxyethylacrylamide (NEEA) and N‐methoxyethylacrylamide (NMEA) were synthesized by aqueous‐phase free‐radical polymerization and characterized by tandem gel permeation chromatography‐multi‐angle laser light scattering. These copolymer matrices exhibit “re‐entrant”‐type volume phase transitions, forming entangled networks with high shear viscosity at low (< 20°C) and high (> 35°C) temperatures, and undergoing a “coil‐to‐globular”, lower critical solution temperature (LCST)‐like phase transition over an intermediate temperature range (20–35°C). Hence, matrix viscosity is relatively low at room temperature (25°C), and increases rapidly above 35°C. The material properties and phase behavior of these thermogelling polymer networks were studied by steady‐shear rheometry. These matrices are easily loaded into capillary arrays at room temperature while existing as viscous fluids, but thermogel above 35°C to form transparent hydrogels via a thermo‐associative phase transition. The extent of the intermediate viscosity drop and the final viscosity increase depends on the composition of the copolymers. DNA sequencing by capillary array electrophoresis with four‐color laser‐induced fluorescence (LIF) detection shows that these thermogelling networks provide enhanced resolution of both small and large DNA sequencing fragments and longer sequencing read lengths, in comparison to appropriate control (closely related, nonthermogelling) polymer networks. In particular, a copolymer comprised of 90% w/w NMEA and 10% w/w NEEA, with a molecular mass of ∼ 2 MDa, delivers around 600 bases at 98.5% base‐calling accuracy in 100 min of electrophoresis.
- 12 December 2003
- Published by Wiley in Electrophoresis
- Vol. 24 (24) , 4161-4169
A novel thermogelling matrix for microchannel DNA sequencing based on poly‐N‐alkoxyalkylacrylamide copolymers
We have developed a novel class of thermogelling polymer networks based on poly‐N‐alkoxyalkylacrylamides, and demonstrated their use as DNA sequencing matrices for high‐throughput microchannel electrophoresis in capillary arrays. Polymers and copolymers of N‐ethoxyethylacrylamide (NEEA) and N‐methoxyethylacrylamide (NMEA) were synthesized by aqueous‐phase free‐radical polymerization and characterized by tandem gel permeation chromatography‐multi‐angle laser light scattering. These copolymer matrices exhibit “re‐entrant”‐type volume phase transitions, forming entangled networks with high shear viscosity at low (< 20°C) and high (> 35°C) temperatures, and undergoing a “coil‐to‐globular”, lower critical solution temperature (LCST)‐like phase transition over an intermediate temperature range (20–35°C). Hence, matrix viscosity is relatively low at room temperature (25°C), and increases rapidly above 35°C. The material properties and phase behavior of these thermogelling polymer networks were studied by steady‐shear rheometry. These matrices are easily loaded into capillary arrays at room temperature while existing as viscous fluids, but thermogel above 35°C to form transparent hydrogels via a thermo‐associative phase transition. The extent of the intermediate viscosity drop and the final viscosity increase depends on the composition of the copolymers. DNA sequencing by capillary array electrophoresis with four‐color laser‐induced fluorescence (LIF) detection shows that these thermogelling networks provide enhanced resolution of both small and large DNA sequencing fragments and longer sequencing read lengths, in comparison to appropriate control (closely related, nonthermogelling) polymer networks. In particular, a copolymer comprised of 90% w/w NMEA and 10% w/w NEEA, with a molecular mass of ∼ 2 MDa, delivers around 600 bases at 98.5% base‐calling accuracy in 100 min of electrophoresis.