Sriram Sripadmanabhan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sriram Sripadmanabhan has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Ravinder K. Banyal
Indian Institute of Astrophysics, Bangalore (India)
3 shared publications- Sireesha Chamarthi
Indian Institute of Astrophysics, Bangalore (India)
3 shared publications Vineeth Valsan
Department of Physics and Electronics, Christ University, Bengaluru, India
3 shared publicationsC Chethan
Indian Institute of Astrophysics, Bengaluru, India
2 shared publicationsFrancis Xavier Rozario J
Indian Institute of Astrophysics, Bengaluru, India
2 shared publicationsG. Nataraj
Indian Institute of Astrophysics, Bengaluru, India
2 shared publications
Latest Publications
- 8 October 2025
- Published by Springer Nature in Experimental Astronomy
- Vol. 60 (2) , 1-26
DMD-based Multi-Object Spectrograph (D-MOS): AIV and first light results
- 8 October 2025
- Published by Springer Nature in Experimental Astronomy
- Vol. 60 (2) , 1-26
DMD-based Multi-Object Spectrograph (D-MOS): AIV and first light results
- 4 September 2025
- Published by Springer Nature in Experimental Astronomy
- Vol. 60 (2) , 1-19
Digital micromirror device characterization in optical band for astronomical multi-object spectrograph
- 4 September 2025
- Published by Springer Nature in Experimental Astronomy
- Vol. 60 (2) , 1-19
Digital micromirror device characterization in optical band for astronomical multi-object spectrograph
- 23 June 2025
- Published by Springer Nature in Experimental Astronomy
- Vol. 60 (1) , 1-22
Design and fabrication of a lightweight three-lens corrector system for the 2.34-m Vainu Bappu telescope
- 23 June 2025
- Published by Springer Nature in Experimental Astronomy
- Vol. 60 (1) , 1-22
Design and fabrication of a lightweight three-lens corrector system for the 2.34-m Vainu Bappu telescope
- Open Access
Design and Fabrication of a lightweight three-lens corrector system for the 2.34-m Vainu Bappu Telescope
The Vainu Bappu Telescope (VBT) is a 2.34-m reflector, primarily supported on-axis field of view, offering high-resolution and low-to-medium resolution spectroscopic observations in its prime and Cassegrain configurations. This study presents the design and fabrication of a compact, lightweight, three-element wide-field corrector (WFC) utilizing three spherical lenses to cover a polychromatic wavelength range over a 30$'$ FoV at prime focus. The WFC design was optimized using ZEMAX, ensuring precision in aberrations, tolerances, and atmospheric dispersion. The fabricated lenses met stringent tolerances, with a $\pm$1 mm deviation in radius of curvature and $\pm$2 mm deviation in center thickness. A mechanical mount was developed to integrate all the WFC lenses, and wavefront error testing for the WFC system was performed using ZYGO interferometry, yielding a Wavefront Error of 0.05 $λ$. Laboratory performance tests were designed and conducted using a dedicated setup with achromatic lenses and 100 $μm$ fiber-coupled polychromatic light source showed a deviation of 0.1 pixel on-axis and 0.5 pixel at the extreme off-axis field compared to the ZEMAX design, demonstrating that the optical performance of WFC is with minimal aberrations across the entire FoV. The successful integration of the WFC at the VBT prime focus will increase the FoV, enabling the multi-fiber, multi-spectrograph setup in 30$'$ field that will facilitate both OMR and Echelle spectrograph to be used on the same night along with the addition of new multi-object spectrograph and an integral field unit instrument. This will mark a significant upgrade for the VBT, broadening its research potential, and expanding its observational versatility.Open AccessDesign and Fabrication of a lightweight three-lens corrector system for the 2.34-m Vainu Bappu Telescope
The Vainu Bappu Telescope (VBT) is a 2.34-m reflector, primarily supported on-axis field of view, offering high-resolution and low-to-medium resolution spectroscopic observations in its prime and Cassegrain configurations. This study presents the design and fabrication of a compact, lightweight, three-element wide-field corrector (WFC) utilizing three spherical lenses to cover a polychromatic wavelength range over a 30$'$ FoV at prime focus. The WFC design was optimized using ZEMAX, ensuring precision in aberrations, tolerances, and atmospheric dispersion. The fabricated lenses met stringent tolerances, with a $\pm$1 mm deviation in radius of curvature and $\pm$2 mm deviation in center thickness. A mechanical mount was developed to integrate all the WFC lenses, and wavefront error testing for the WFC system was performed using ZYGO interferometry, yielding a Wavefront Error of 0.05 $λ$. Laboratory performance tests were designed and conducted using a dedicated setup with achromatic lenses and 100 $μm$ fiber-coupled polychromatic light source showed a deviation of 0.1 pixel on-axis and 0.5 pixel at the extreme off-axis field compared to the ZEMAX design, demonstrating that the optical performance of WFC is with minimal aberrations across the entire FoV. The successful integration of the WFC at the VBT prime focus will increase the FoV, enabling the multi-fiber, multi-spectrograph setup in 30$'$ field that will facilitate both OMR and Echelle spectrograph to be used on the same night along with the addition of new multi-object spectrograph and an integral field unit instrument. This will mark a significant upgrade for the VBT, broadening its research potential, and expanding its observational versatility. - 8 June 2023
- Published by Springer Nature in Journal of Astrophysics and Astronomy
- Vol. 44 (2) , 1-23
Indian spectroscopic and imaging space telescope (INSIST): An optics design trade-off study
- 8 June 2023
- Published by Springer Nature in Journal of Astrophysics and Astronomy
- Vol. 44 (2) , 1-23
Indian spectroscopic and imaging space telescope (INSIST): An optics design trade-off study
- 10 June 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 5 (03) , 038003-10
Estimation and correction of the instrumental perturbations of Vainu Bappu Telescope Echelle spectrograph using a model-based approach
The Echelle spectrograph operating at Vainu Bappu Telescope, India, is a general purpose instrument used for many high-resolution spectroscopic observations. A concerted effort is being made to expand the scientific capability of the instrument in emerging areas of observational astronomy. We aim at evaluating the feasibility of the spectrograph to carry out precision radial velocity (RV) measurements. In the current design, major factors limiting the RV precision of the spectrograph arise from the movable grating and slit, optical aberrations, positional uncertainty associated with optomechanical mounts, and environmental and thermal instabilities in the spectrograph room. RV instabilities due to temperature and pressure variations in the environment are estimated to vary between 120 and 400 ms − 1, respectively. The positional uncertainty of the grating in the spectrograph could induce a spectral shift of ∼1.4 km s − 1 across the Echelle orders. A Zemax model is used to overcome the uncertainty in the zero-positioning and lack of repeatability of the moving components. We propose to obtain the Th-Ar lamp observations and using the Zemax model as the reference, predict the drifts in the positions of the optical components. The perturbations of the optical components from the nominal position are corrected at the beginning of the observational run. After a good match is obtained between the model and the observations, we propose to use a Zemax model to improve the wavelength calibration solution. We could match the observations and model within ±1 pixels accuracy after the model parameters are perturbed in a real-time setup of the spectrograph. We present the estimation of the perturbations of optical components and the effect on the RV obtained.
- 10 June 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 5 (03) , 038003-10
Estimation and correction of the instrumental perturbations of Vainu Bappu Telescope Echelle spectrograph using a model-based approach
The Echelle spectrograph operating at Vainu Bappu Telescope, India, is a general purpose instrument used for many high-resolution spectroscopic observations. A concerted effort is being made to expand the scientific capability of the instrument in emerging areas of observational astronomy. We aim at evaluating the feasibility of the spectrograph to carry out precision radial velocity (RV) measurements. In the current design, major factors limiting the RV precision of the spectrograph arise from the movable grating and slit, optical aberrations, positional uncertainty associated with optomechanical mounts, and environmental and thermal instabilities in the spectrograph room. RV instabilities due to temperature and pressure variations in the environment are estimated to vary between 120 and 400 ms − 1, respectively. The positional uncertainty of the grating in the spectrograph could induce a spectral shift of ∼1.4 km s − 1 across the Echelle orders. A Zemax model is used to overcome the uncertainty in the zero-positioning and lack of repeatability of the moving components. We propose to obtain the Th-Ar lamp observations and using the Zemax model as the reference, predict the drifts in the positions of the optical components. The perturbations of the optical components from the nominal position are corrected at the beginning of the observational run. After a good match is obtained between the model and the observations, we propose to use a Zemax model to improve the wavelength calibration solution. We could match the observations and model within ±1 pixels accuracy after the model parameters are perturbed in a real-time setup of the spectrograph. We present the estimation of the perturbations of optical components and the effect on the RV obtained.
- Open Access
- 5 June 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 5 (02) , 029801-1
Toward precision radial velocity measurements using Echelle spectrograph at Vainu Bappu Telescope (Erratum)
This erratum corrects an error in the composition of Table 2. This article [J. Astron. Telesc. Instrum. Syst. 5(2), 028004 (2019), doi: 10.1117/1.JATIS.5.2.028004] was originally published online with an error in Table 2. The data in the column labeled “JD (2000)” did not correspond to the data in the columns labeled “Radial velocity” and “Uncertainty.” The table has been corrected as shown below: Table 2 Julian date of observations and corresponding radial velocities obtained for Tau Boötis. JD (2000) Radial velocity (km s−1) Uncertainty (km s−1) 2457871.1843 0.05995 0.03 2457871.2022 0.05270 0.04 2457871.2186 0.06292 0.03 2457871.2366 0.06267 0.02 2457871.2545 0.05602 0.02 2457871.2715 0.04926 0.04 2457871.2892 0.04884 0.02 2458181.3911 0.31474 0.02 2458181.4122 0.33236 0.02 2458181.4205 0.29238 0.01 2458181.4379 0.31520 0.02 2458181.4463 0.34261 0.03 2458181.4626 0.35096 0.04 2458181.4719 0.34691 0.02 2458181.49 0.39545 0.01 2458182.2818 0.29121 0.04 2458182.2902 0.35849 0.04 2458182.307 0.31847 0.05 2458182.3153 0.24898 0.04 2458182.331 0.18770 0.03 2458182.3392 0.24593 0.01 2458182.3527 0.17042 0.03 2458182.3615 0.36236 0.04 2458182.3797 0.26432 0.02 2458182.3881 0.25536 0.01 2458182.4023 0.22777 0.05 2458182.4106 0.18878 0.03 2458182.425 0.19093 0.03 2458182.4333 0.14799 0.04 2458182.4584 0.09066 0.02 2458182.4697 0.11465 0.04 2458182.4834 0.03204 0.01 All online versions of the article were corrected on 22 May 2019. The article appears correctly in print.
- 5 June 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 5 (02) , 029801-1
Open AccessToward precision radial velocity measurements using Echelle spectrograph at Vainu Bappu Telescope (Erratum)
This erratum corrects an error in the composition of Table 2. This article [J. Astron. Telesc. Instrum. Syst. 5(2), 028004 (2019), doi: 10.1117/1.JATIS.5.2.028004] was originally published online with an error in Table 2. The data in the column labeled “JD (2000)” did not correspond to the data in the columns labeled “Radial velocity” and “Uncertainty.” The table has been corrected as shown below: Table 2 Julian date of observations and corresponding radial velocities obtained for Tau Boötis. JD (2000) Radial velocity (km s−1) Uncertainty (km s−1) 2457871.1843 0.05995 0.03 2457871.2022 0.05270 0.04 2457871.2186 0.06292 0.03 2457871.2366 0.06267 0.02 2457871.2545 0.05602 0.02 2457871.2715 0.04926 0.04 2457871.2892 0.04884 0.02 2458181.3911 0.31474 0.02 2458181.4122 0.33236 0.02 2458181.4205 0.29238 0.01 2458181.4379 0.31520 0.02 2458181.4463 0.34261 0.03 2458181.4626 0.35096 0.04 2458181.4719 0.34691 0.02 2458181.49 0.39545 0.01 2458182.2818 0.29121 0.04 2458182.2902 0.35849 0.04 2458182.307 0.31847 0.05 2458182.3153 0.24898 0.04 2458182.331 0.18770 0.03 2458182.3392 0.24593 0.01 2458182.3527 0.17042 0.03 2458182.3615 0.36236 0.04 2458182.3797 0.26432 0.02 2458182.3881 0.25536 0.01 2458182.4023 0.22777 0.05 2458182.4106 0.18878 0.03 2458182.425 0.19093 0.03 2458182.4333 0.14799 0.04 2458182.4584 0.09066 0.02 2458182.4697 0.11465 0.04 2458182.4834 0.03204 0.01 All online versions of the article were corrected on 22 May 2019. The article appears correctly in print.
- 20 May 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 5 (02) , 028004-9
Toward precision radial velocity measurements using Echelle spectrograph at Vainu Bappu Telescope
The Echelle spectrograph operating at Vainu Bappu Telescope is a general purpose instrument designed for high-resolution spectroscopy. It is being considered for precision Doppler measurements without altering the existing design and basic usage. However, the design level limitations and environmental perturbations are a major source of instability and systematic errors. As a result, a small Doppler signal in the stellar spectra is completely swamped by the large and uncontrolled instrumental drift. We discuss some of the remedial measures we took to improve the radial velocity performance of the spectrograph. We show that an autoguider assembly has greatly reduced the mechanical jitter of the star image at the fiber input, making the illumination of the spectrograph slit at the other end stable. We have also installed an iodine absorption cell to track and eliminate the instrumental drifts to facilitate precision radial velocity observations. Furthermore, we have developed a generic algorithm that uses iodine exposures to extract the stellar radial velocities without the need for the complex forward modeling. Our algorithm is not accurate to the level of traditional iodine technique. However, it is convenient to use on a low-cost general-purpose spectrograph targeting a moderate radial velocity (RV) precision at a few 10 to 100 ms − 1 level. Finally, we have demonstrated the usefulness of our approach by measuring the RV signal of a well-known short-period, planet-hosting star.
- 20 May 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 5 (02) , 028004-9
Toward precision radial velocity measurements using Echelle spectrograph at Vainu Bappu Telescope
The Echelle spectrograph operating at Vainu Bappu Telescope is a general purpose instrument designed for high-resolution spectroscopy. It is being considered for precision Doppler measurements without altering the existing design and basic usage. However, the design level limitations and environmental perturbations are a major source of instability and systematic errors. As a result, a small Doppler signal in the stellar spectra is completely swamped by the large and uncontrolled instrumental drift. We discuss some of the remedial measures we took to improve the radial velocity performance of the spectrograph. We show that an autoguider assembly has greatly reduced the mechanical jitter of the star image at the fiber input, making the illumination of the spectrograph slit at the other end stable. We have also installed an iodine absorption cell to track and eliminate the instrumental drifts to facilitate precision radial velocity observations. Furthermore, we have developed a generic algorithm that uses iodine exposures to extract the stellar radial velocities without the need for the complex forward modeling. Our algorithm is not accurate to the level of traditional iodine technique. However, it is convenient to use on a low-cost general-purpose spectrograph targeting a moderate radial velocity (RV) precision at a few 10 to 100 ms − 1 level. Finally, we have demonstrated the usefulness of our approach by measuring the RV signal of a well-known short-period, planet-hosting star.
- 17 May 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 4 (02) , 025001-9
Design and modeling of a tunable spatial heterodyne spectrometer for emission line studies
Spatial heterodyne spectroscopy (SHS) is an interferometric technique similar to the Fourier transform spectroscopy with heritage from the Michelson interferometer. An imaging detector is used at the output of an SHS to record the spatially heterodyned interference pattern. The spectrum of the source is obtained by Fourier transforming the recorded interferogram. The merits of the SHS—its design, including the absence of moving parts, compactness, high throughput, high SNR, and instantaneous spectral measurements—make it suitable for space as well as for ground observatories. The small bandwidth limitation of the SHS can be overcome by building it in tunable configuration [tunable spatial heterodyne spectrometer (TSHS)]. We describe the design, development, and simulation of a TSHS in refractive configuration suitable for optical wavelength regime. Here we use a beam splitter to split the incoming light compared with all-reflective SHS where a reflective grating does the beam splitting. Hence, the alignment of this instrument is simple compared with all-reflective SHS where a fold mirror and a roof mirror are used to combine the beam. This instrument is intended to study faint diffuse extended celestial objects with a resolving power above 20,000 and can cover a wavelength range from 350 to 700 nm by tuning. It is compact and rugged compared with other instruments having similar configurations.
- 17 May 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 4 (02) , 025001-9
Design and modeling of a tunable spatial heterodyne spectrometer for emission line studies
Spatial heterodyne spectroscopy (SHS) is an interferometric technique similar to the Fourier transform spectroscopy with heritage from the Michelson interferometer. An imaging detector is used at the output of an SHS to record the spatially heterodyned interference pattern. The spectrum of the source is obtained by Fourier transforming the recorded interferogram. The merits of the SHS—its design, including the absence of moving parts, compactness, high throughput, high SNR, and instantaneous spectral measurements—make it suitable for space as well as for ground observatories. The small bandwidth limitation of the SHS can be overcome by building it in tunable configuration [tunable spatial heterodyne spectrometer (TSHS)]. We describe the design, development, and simulation of a TSHS in refractive configuration suitable for optical wavelength regime. Here we use a beam splitter to split the incoming light compared with all-reflective SHS where a reflective grating does the beam splitting. Hence, the alignment of this instrument is simple compared with all-reflective SHS where a fold mirror and a roof mirror are used to combine the beam. This instrument is intended to study faint diffuse extended celestial objects with a resolving power above 20,000 and can cover a wavelength range from 350 to 700 nm by tuning. It is compact and rugged compared with other instruments having similar configurations.
- Open Access
Stability analysis of VBT Echelle spectrograph for precise radial velocity measurements
A fiber-fed Echelle spectrograph at 2.3 m Vainu Bappu Telescope (VBT), Kavalur, has been in operation since 2005. Owing to various technological advancements in precision spectroscopy in recent years, several research avenues have been opened in observational astronomy. These developments have created a demand to improve the Doppler precision of our spectrograph. Currently, the stability of the instrument is compromised by the temperature and pressure fluctuations inside the Echelle room. Further, a better wavelength calibration approach is needed to carefully track and disentangle the instrumental effects from stellar spectra. While planning a possible upgrade with an Iodine absorption gas cell, we measured the raw stability of the spectrograph using a series of calibration frames taken with the ThAr gas discharge lamp. The time series data were analysed with cross-correlation method and the shift in ThAr emission lines was accurately measured across different Echelle orders. In this paper, we present our stability analysis methodology and results for the Kavalur spectrograph. We also identify possible sources of error and discuss our strategy to mitigate them.
Open AccessStability analysis of VBT Echelle spectrograph for precise radial velocity measurements
A fiber-fed Echelle spectrograph at 2.3 m Vainu Bappu Telescope (VBT), Kavalur, has been in operation since 2005. Owing to various technological advancements in precision spectroscopy in recent years, several research avenues have been opened in observational astronomy. These developments have created a demand to improve the Doppler precision of our spectrograph. Currently, the stability of the instrument is compromised by the temperature and pressure fluctuations inside the Echelle room. Further, a better wavelength calibration approach is needed to carefully track and disentangle the instrumental effects from stellar spectra. While planning a possible upgrade with an Iodine absorption gas cell, we measured the raw stability of the spectrograph using a series of calibration frames taken with the ThAr gas discharge lamp. The time series data were analysed with cross-correlation method and the shift in ThAr emission lines was accurately measured across different Echelle orders. In this paper, we present our stability analysis methodology and results for the Kavalur spectrograph. We also identify possible sources of error and discuss our strategy to mitigate them.