Nikita Denisov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nikita Denisov has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Andrey Sergeevich Orekhov
EMAT, University of Antwerp, 2020 Antwerp, Belgium
2 shared publications - Johan Verbeeck
University of Antwerp
2 shared publications Andrey Orekhov
EMAT University of Antwerp Groenenborgerlaan 171 2020 Antwerp Belgium
1 shared publication- Daen Jannis
EMAT, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium; NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium
1 shared publication Johan Verbeeck
EMAT University of Antwerp Groenenborgerlaan 171 2020 Antwerp Belgium
1 shared publication- Knut Müller-Caspary
Department of Chemistry and Center for Nanoscience, Ludwig-Maximilians-Universität München, Butenandtstr. 11, 81377 München, Germany
1 shared publication
Latest Publications
- Open Access
- 18 February 2025
- Published by EDP Sciences in The European Physical Journal Applied Physics
- Vol. 100
Edge-Detected 4DSTEM - effective low-dose diffraction data acquisition method for nanopowder samples in an SEM instrument
The appearance of direct electron detectors marked a new era for electron diffraction. Their high sensitivity and low noise opens the possibility to extend electron diffraction from transmission electron microscopes (TEM) to lower energies such as those found in commercial scanning electron microscopes (SEM). The lower acceleration voltage does however put constraints on the maximum sample thickness and it is a-priori unclear how useful such a diffraction setup could be. On the other hand, nanoparticles are increasingly appearing in consumer products and could form an attractive class of naturally thin samples to investigate with this setup. In this work we present such a diffraction setup and discuss methods to effectively collect and process diffraction data from dispersed crystalline nanoparticles in a commercial SEM instrument. We discuss ways to drastically reduce acquisition time while at the same time lowering beam damage and contamination issues as well as providing significant data reduction leading to fast processing and modest data storage needs. These approaches are also amenable to TEM and could be especially useful in the case of beam-sensitive objects.
- 18 February 2025
- Published by EDP Sciences in The European Physical Journal Applied Physics
- Vol. 100
Open AccessEdge-Detected 4DSTEM - effective low-dose diffraction data acquisition method for nanopowder samples in an SEM instrument
The appearance of direct electron detectors marked a new era for electron diffraction. Their high sensitivity and low noise opens the possibility to extend electron diffraction from transmission electron microscopes (TEM) to lower energies such as those found in commercial scanning electron microscopes (SEM). The lower acceleration voltage does however put constraints on the maximum sample thickness and it is a-priori unclear how useful such a diffraction setup could be. On the other hand, nanoparticles are increasingly appearing in consumer products and could form an attractive class of naturally thin samples to investigate with this setup. In this work we present such a diffraction setup and discuss methods to effectively collect and process diffraction data from dispersed crystalline nanoparticles in a commercial SEM instrument. We discuss ways to drastically reduce acquisition time while at the same time lowering beam damage and contamination issues as well as providing significant data reduction leading to fast processing and modest data storage needs. These approaches are also amenable to TEM and could be especially useful in the case of beam-sensitive objects.
- Open Access
Edge-Detected 4DSTEM -- effective low-dose diffraction data acquisition method for nanopowder samples in a SEM instrument
The appearance of direct electron detectors marked a new era for electron diffraction. Their high sensitivity and low noise opens the possibility to extend electron diffraction from transmission electron microscopes (TEM) to lower energies such as those found in commercial scanning electron microscopes (SEM).The lower acceleration voltage does however put constraints on the maximum sample thickness and it is a-priori unclear how useful such a diffraction setup could be. On the other hand, nanoparticles are increasingly appearing in consumer products and could form an attractive class of naturally thin samples to investigate with this setup.In this work we present such a diffraction setup and discuss methods to effectively collect and process diffraction data from dispersed crystalline nanoparticles in a commercial SEM instrument. We discuss ways to drastically reduce acquisition time while at the same time lowering beam damage and contamination issues as well as providing significant data reduction leading to fast processing and modest data storage needs. These approaches are also amenable to TEM and could be especially useful in the case of beam-sensitive objects.
Open AccessEdge-Detected 4DSTEM -- effective low-dose diffraction data acquisition method for nanopowder samples in a SEM instrument
The appearance of direct electron detectors marked a new era for electron diffraction. Their high sensitivity and low noise opens the possibility to extend electron diffraction from transmission electron microscopes (TEM) to lower energies such as those found in commercial scanning electron microscopes (SEM).The lower acceleration voltage does however put constraints on the maximum sample thickness and it is a-priori unclear how useful such a diffraction setup could be. On the other hand, nanoparticles are increasingly appearing in consumer products and could form an attractive class of naturally thin samples to investigate with this setup.In this work we present such a diffraction setup and discuss methods to effectively collect and process diffraction data from dispersed crystalline nanoparticles in a commercial SEM instrument. We discuss ways to drastically reduce acquisition time while at the same time lowering beam damage and contamination issues as well as providing significant data reduction leading to fast processing and modest data storage needs. These approaches are also amenable to TEM and could be especially useful in the case of beam-sensitive objects.
- 8 June 2023
- Published by Elsevier in Ultramicroscopy
- Vol. 253, 113777
Characterization of a Timepix detector for use in SEM acceleration voltage range
- 8 June 2023
- Published by Elsevier in Ultramicroscopy
- Vol. 253, 113777
Characterization of a Timepix detector for use in SEM acceleration voltage range
- 1 January 2021
- Published by The Russian Academy of Sciences in Физика металлов и металловедение
- Vol. 122 (11) , 1142-1148
Взаимодействие поверхности ленты с ацетоном и магнитные характеристики аморфного магнитомягкого сплава на основе кобальта
Проведенные исследования показали, что обработка ацетоном ленты аморфного магнитомягкого сплава Co–Ni–Fe–Cr–Mn–Si–B оказывает влияние на ее магнитные характеристики. Оно различно для состояний ленты с разными знаками константы магнитострикции (λs). В состоянии с λs > 0 наблюдается увеличение объема доменов с ортогональной намагниченностью и остроты магнитной текстуры в плоскости ленты; с λs < 0 имеет место уменьшение объема доменов с ортогональной намагниченностью, снижение остроты магнитной текстуры в плоскости ленты и повышение максимальной магнитной проницаемости. Увеличение длительности обработки усиливает ее влияние на объемную компоненту намагниченности и ослабляет воздействие на перераспределение намагниченности в плоскости ленты. Это может быть связано с повышением уровня сжимающих напряжений, индуцированных каталитическим окислением и гидрированием ацетона.
- 1 January 2021
- Published by The Russian Academy of Sciences in Физика металлов и металловедение
- Vol. 122 (11) , 1142-1148
Взаимодействие поверхности ленты с ацетоном и магнитные характеристики аморфного магнитомягкого сплава на основе кобальта
Проведенные исследования показали, что обработка ацетоном ленты аморфного магнитомягкого сплава Co–Ni–Fe–Cr–Mn–Si–B оказывает влияние на ее магнитные характеристики. Оно различно для состояний ленты с разными знаками константы магнитострикции (λs). В состоянии с λs > 0 наблюдается увеличение объема доменов с ортогональной намагниченностью и остроты магнитной текстуры в плоскости ленты; с λs < 0 имеет место уменьшение объема доменов с ортогональной намагниченностью, снижение остроты магнитной текстуры в плоскости ленты и повышение максимальной магнитной проницаемости. Увеличение длительности обработки усиливает ее влияние на объемную компоненту намагниченности и ослабляет воздействие на перераспределение намагниченности в плоскости ленты. Это может быть связано с повышением уровня сжимающих напряжений, индуцированных каталитическим окислением и гидрированием ацетона.