NDNikita Denisov

Nikita Denisov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nikita Denisov has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Edge-Detected 4DSTEM - effective low-dose diffraction data acquisition method for nanopowder samples in an SEM instrument

    by Nikita Denisov, Andrey Orekhov, Johan Verbeeck

    The appearance of direct electron detectors marked a new era for electron diffraction. Their high sensitivity and low noise opens the possibility to extend electron diffraction from transmission electron microscopes (TEM) to lower energies such as those found in commercial scanning electron microscopes (SEM). The lower acceleration voltage does however put constraints on the maximum sample thickness and it is a-priori unclear how useful such a diffraction setup could be. On the other hand, nanoparticles are increasingly appearing in consumer products and could form an attractive class of naturally thin samples to investigate with this setup. In this work we present such a diffraction setup and discuss methods to effectively collect and process diffraction data from dispersed crystalline nanoparticles in a commercial SEM instrument. We discuss ways to drastically reduce acquisition time while at the same time lowering beam damage and contamination issues as well as providing significant data reduction leading to fast processing and modest data storage needs. These approaches are also amenable to TEM and could be especially useful in the case of beam-sensitive objects.


  • Open Access

    Edge-Detected 4DSTEM -- effective low-dose diffraction data acquisition method for nanopowder samples in a SEM instrument

    by Nikita Denisov, Andrey Orekhov, Johan Verbeeck

    The appearance of direct electron detectors marked a new era for electron diffraction. Their high sensitivity and low noise opens the possibility to extend electron diffraction from transmission electron microscopes (TEM) to lower energies such as those found in commercial scanning electron microscopes (SEM).The lower acceleration voltage does however put constraints on the maximum sample thickness and it is a-priori unclear how useful such a diffraction setup could be. On the other hand, nanoparticles are increasingly appearing in consumer products and could form an attractive class of naturally thin samples to investigate with this setup.In this work we present such a diffraction setup and discuss methods to effectively collect and process diffraction data from dispersed crystalline nanoparticles in a commercial SEM instrument. We discuss ways to drastically reduce acquisition time while at the same time lowering beam damage and contamination issues as well as providing significant data reduction leading to fast processing and modest data storage needs. These approaches are also amenable to TEM and could be especially useful in the case of beam-sensitive objects.

  • Characterization of a Timepix detector for use in SEM acceleration voltage range

    by Nikita Denisov, Daen Jannis, Andrey Orekhov, Knut Müller-Caspary, Johan Verbeeck


  • Взаимодействие поверхности ленты с ацетоном и магнитные характеристики аморфного магнитомягкого сплава на основе кобальта

    by Н. А. Скулкина, Н. Д. Денисов, Е. С. Некрасов

    Проведенные исследования показали, что обработка ацетоном ленты аморфного магнитомягкого сплава Co–Ni–Fe–Cr–Mn–Si–B оказывает влияние на ее магнитные характеристики. Оно различно для состояний ленты с разными знаками константы магнитострикции (λs). В состоянии с λs > 0 наблюдается увеличение объема доменов с ортогональной намагниченностью и остроты магнитной текстуры в плоскости ленты; с λs < 0 имеет место уменьшение объема доменов с ортогональной намагниченностью, снижение остроты магнитной текстуры в плоскости ленты и повышение максимальной магнитной проницаемости. Увеличение длительности обработки усиливает ее влияние на объемную компоненту намагниченности и ослабляет воздействие на перераспределение намагниченности в плоскости ленты. Это может быть связано с повышением уровня сжимающих напряжений, индуцированных каталитическим окислением и гидрированием ацетона.