Peizhan Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Peizhan Li has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Jing Li
Chinese Academy of Sciences
4 shared publicationsShengcai Shi
Chinese Academy of Sciences
4 shared publications- Wen Zhang
Chinese Academy of Sciences
4 shared publications Qijun Yao
Chinese Academy of Sciences
3 shared publications- Wei Miao
Purple Mountain Observatory, Chinese Academy of Sciences, Nanjing, China
3 shared publications - Jia-Qiang Zhong
Purple Mountain Observatory, Chinese Academy of Sciences, Nanjing, China
2 shared publications
Latest Publications
- 5 November 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (23) , 43973
Field demonstration of multimode-fiber-coupled SNSPDs in distributed debris laser ranging at 1064 nm
Space debris collision avoidance is essential for space mission safety, yet conventional observation techniques often lack the precision required for high-confidence collision warning. Distributed debris laser ranging with decimeter-level precision offers a promising solution, but the diffuse reflection echoes are extremely weak and easily obscured by noise. To address these challenges, we developed an application-oriented 1064 nm SNSPD system with a 50 µm-diameter active area coupled to a 50 µm-core multimode fiber, together with a cryogenic optical fiber bandpass filter for efficient photon collection and background suppression. The detector was characterized at 2.6 K and 0.22 K, achieving system detection efficiencies of 48% and 56%, respectively, at a dark count rate of 100 Hz. A minimum timing jitter of 46.5 ps was measured at 0.22 K. Importantly, we demonstrate, for the first time, SNSPD-based detection in a distributed debris laser ranging system, achieving a local noise count ratio of 6.4% and high-SNR debris echoes. The acquired echoes exhibit distinct broadening distributions that may enable the retrieval of debris shape, attitude, and center-of-mass position, supporting more accurate orbit determination.
- 5 November 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (23) , 43973
Field demonstration of multimode-fiber-coupled SNSPDs in distributed debris laser ranging at 1064 nm
Space debris collision avoidance is essential for space mission safety, yet conventional observation techniques often lack the precision required for high-confidence collision warning. Distributed debris laser ranging with decimeter-level precision offers a promising solution, but the diffuse reflection echoes are extremely weak and easily obscured by noise. To address these challenges, we developed an application-oriented 1064 nm SNSPD system with a 50 µm-diameter active area coupled to a 50 µm-core multimode fiber, together with a cryogenic optical fiber bandpass filter for efficient photon collection and background suppression. The detector was characterized at 2.6 K and 0.22 K, achieving system detection efficiencies of 48% and 56%, respectively, at a dark count rate of 100 Hz. A minimum timing jitter of 46.5 ps was measured at 0.22 K. Importantly, we demonstrate, for the first time, SNSPD-based detection in a distributed debris laser ranging system, achieving a local noise count ratio of 6.4% and high-SNR debris echoes. The acquired echoes exhibit distinct broadening distributions that may enable the retrieval of debris shape, attitude, and center-of-mass position, supporting more accurate orbit determination.
- 1 September 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39 (9) , 095019
Development of a microwave SQUID multiplexer for superconducting transition-edge sensor bolometer arrays
A microwave SQUID multiplexer ( μ MUX) with a high multiplexing factor is a promising readout approach for large-scale superconducting transition-edge sensor (TES) bolometer arrays. This paper reports on the characteristics of 16-channel μ MUX prototype chips and a 60-channel readout module developed to read out TES bolometers for the Ali cosmic microwave background polarization telescope (AliCPT). We designed two different coupling structures between the resonator and the radio-frequency superconducting interference device: design A with a mutual inductance ( M T ) of 2.3 pH and design B with an M T of 6.5 pH. For design A, the mean resonator bandwidth ( Δ f BW ) and peak-to-peak frequency shift ( Δ f pp ) are approximately 610 kHz and 290 kHz, respectively. The measured mean open-loop current noise is less than 40 pA / Hz . Preliminary results indicate that crosstalk between adjacent channels is below 1% in our design A μ MUX chip. A measured channel with design B shows a Δ f BW of 586 kHz and a current noise of 33 pA / Hz , similar to the design A channels. In comparison, the Δ f pp of 803 kHz is much larger than the design A channels due to a larger M T . The readout module, consisting of two design A chips and two design B chips, shows 60 resonances, corresponding to a yield of 94%. In the future, we will place 32 design A channels within the same chip dimension to increase the channel density and build a larger readout module suitable for AliCPT TES arrays.
- 1 September 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39 (9) , 095019
Development of a microwave SQUID multiplexer for superconducting transition-edge sensor bolometer arrays
A microwave SQUID multiplexer ( μ MUX) with a high multiplexing factor is a promising readout approach for large-scale superconducting transition-edge sensor (TES) bolometer arrays. This paper reports on the characteristics of 16-channel μ MUX prototype chips and a 60-channel readout module developed to read out TES bolometers for the Ali cosmic microwave background polarization telescope (AliCPT). We designed two different coupling structures between the resonator and the radio-frequency superconducting interference device: design A with a mutual inductance ( M T ) of 2.3 pH and design B with an M T of 6.5 pH. For design A, the mean resonator bandwidth ( Δ f BW ) and peak-to-peak frequency shift ( Δ f pp ) are approximately 610 kHz and 290 kHz, respectively. The measured mean open-loop current noise is less than 40 pA / Hz . Preliminary results indicate that crosstalk between adjacent channels is below 1% in our design A μ MUX chip. A measured channel with design B shows a Δ f BW of 586 kHz and a current noise of 33 pA / Hz , similar to the design A channels. In comparison, the Δ f pp of 803 kHz is much larger than the design A channels due to a larger M T . The readout module, consisting of two design A chips and two design B chips, shows 60 resonances, corresponding to a yield of 94%. In the future, we will place 32 design A channels within the same chip dimension to increase the channel density and build a larger readout module suitable for AliCPT TES arrays.
- Open Access
- 1 December 2025
- Published by AIP Publishing in APL Photonics
- Vol. 10 (12)
A TES single-photon detector demonstrating high-energy-resolution, high efficiency, and ultra-low dark counts near 0.9 T c
Transition-edge sensors (TESs) are among the most promising technologies for single-photon detection, offering high quantum efficiency, low dark count rates, and energy-resolving capabilities. However, optimal TES performance typically requires ultra-low temperatures below 100 mK, necessitating bulky dilution refrigerators or adiabatic demagnetization refrigerators, which limits their practical deployment. In this work, we demonstrate a titanium-based TES optimized for 1064 nm photon detection that achieves high performance at an elevated bath temperature of 220 mK—approximately 90% of its superconducting transition temperature, making it compatible with more compact sorption refrigerators. Through the integration of an optical cavity, a detailed complex impedance and noise characterization, and a systematic investigation of dark count sources, the detector achieves a system detection efficiency exceeding 97%, an energy resolution of 240 meV, and an intrinsic dark count rate as low as 2 × 10−4 cps. These findings significantly expand the applicability of TES single-photon detectors to practical photon-counting systems, such as quantum information and infrared astronomy.
- 1 December 2025
- Published by AIP Publishing in APL Photonics
- Vol. 10 (12)
Open AccessA TES single-photon detector demonstrating high-energy-resolution, high efficiency, and ultra-low dark counts near 0.9 T c
Transition-edge sensors (TESs) are among the most promising technologies for single-photon detection, offering high quantum efficiency, low dark count rates, and energy-resolving capabilities. However, optimal TES performance typically requires ultra-low temperatures below 100 mK, necessitating bulky dilution refrigerators or adiabatic demagnetization refrigerators, which limits their practical deployment. In this work, we demonstrate a titanium-based TES optimized for 1064 nm photon detection that achieves high performance at an elevated bath temperature of 220 mK—approximately 90% of its superconducting transition temperature, making it compatible with more compact sorption refrigerators. Through the integration of an optical cavity, a detailed complex impedance and noise characterization, and a systematic investigation of dark count sources, the detector achieves a system detection efficiency exceeding 97%, an energy resolution of 240 meV, and an intrinsic dark count rate as low as 2 × 10−4 cps. These findings significantly expand the applicability of TES single-photon detectors to practical photon-counting systems, such as quantum information and infrared astronomy.
- 6 February 2025
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 38 (3) , 035005
Complex impedance measurement and saturation energy analysis of optical transition-edge sensors
Transition edge sensors (TESs) are highly sensitive thermal detectors that operate across a wide frequency range, from millimeter waves to gamma rays. For optical-single photon TES detectors, a high energy resolution and large saturation energy are required, primarily limited by factors such as heat capacitance and temperature sensitivity, α I . In this study, we evaluated TES devices of varying sizes by conducting complex impedance measurements using transfer function calibration, revealing that our titanium-based TES exhibits higher heat capacities compared to theoretical values. We obtained the measured and theoretical time constants, energy resolutions, and saturation energies for the different-sized TESs, notably constructing histograms from pulse area integral analysis. Our devices achieved an optimal energy resolution of 0.2 eV, with the largest TES demonstrating an energy resolution of 0.34 eV, a saturation energy of 35 eV and the ability to discriminate up to 20 photons at 438 nm. These results provide valuable insights for optimizing TES performance in precise photon detection.
- 6 February 2025
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 38 (3) , 035005
Complex impedance measurement and saturation energy analysis of optical transition-edge sensors
Transition edge sensors (TESs) are highly sensitive thermal detectors that operate across a wide frequency range, from millimeter waves to gamma rays. For optical-single photon TES detectors, a high energy resolution and large saturation energy are required, primarily limited by factors such as heat capacitance and temperature sensitivity, α I . In this study, we evaluated TES devices of varying sizes by conducting complex impedance measurements using transfer function calibration, revealing that our titanium-based TES exhibits higher heat capacities compared to theoretical values. We obtained the measured and theoretical time constants, energy resolutions, and saturation energies for the different-sized TESs, notably constructing histograms from pulse area integral analysis. Our devices achieved an optimal energy resolution of 0.2 eV, with the largest TES demonstrating an energy resolution of 0.34 eV, a saturation energy of 35 eV and the ability to discriminate up to 20 photons at 438 nm. These results provide valuable insights for optimizing TES performance in precise photon detection.