Jennifer S. Wayne
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jennifer S. Wayne has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
John R. Owen
Richmond, Va
4 shared publicationsRobert S. Adelaar
Richmond, Va
3 shared publicationsAaron T. Scott
Virginia Commonwealth University, Richmond, VA 23298, USA
2 shared publicationsKelly J. Shields
Orthopaedic Research Laboratory, Departments of Biomedical Engineering and Orthopedic Surgery, Virginia Commonwealth University, Richmond, Virginia
2 shared publicationsC L McDowell
1 shared publicationC.E. Spoon
Departments of Biomedical Engineering and Orthopaedic Surgery, Virginia Commonwealth University, Richmond, VA 23298-0694, USA
1 shared publication
Latest Publications
- 1 February 2009
- Published by SAGE Publications in Foot & Ankle International
- Vol. 30 (2) , 150-156
Biomechanical Comparison of Screw Versus Plate/Screw Construct for Talonavicular Fusion
Background: Talonavicular fusion is performed for a variety of indications. This study examined the effects of fixation techniques on plantar pressures, construct stiffness, and strength. Materials and Methods: Eight matched pairs of cadaveric lower extremities were axially loaded intact and after talonavicular fixation with a 3.5 reconstruction plate, reconstruction plate plus cancellous screw (plate/screw), or three screws (screws). Recorded plantar pressures were divided into three forefoot, two midfoot, and two hindfoot regions. Cantilevered bending of excised constructs provided stiffness data for plantar and lateral directions, and failure characteristics in plantar bending. Results: Relative to the intact state, all fixations decreased peak pressure in the medial forefoot, while generally increasing it in the lateral forefoot and midfoot. Average pressure shifted laterally for all fixation methods in the forefoot, generally in the hindfoot and the lateral midfoot. Generally, contact areas decreased in the medial forefoot, midfoot, and hindfoot while increasing laterally in the midfoot and hindfoot. The only difference among fixation methods was a decreased medial midfoot contact area for screws. No differences were found between screws and plate/screw in bending stiffness or failure ( p < 0.5 and p < 0.2 respectively). Plantar and lateral bending stiffness for the plate/screw method averaged approximately 363 N/mm while stiffness of the screw only construct averaged approximately 380 N/mm. The load to failure averaged 946 N for the plate/screw construct and 1099 N for the screw construct. Conclusion: This study showed lateralization of plantar pressures following talonavicular fixation. Minimal differences were found between plate/screw and screws. Fixation across the joint may be key to achieving stability sufficient to resist shear and rotational stresses. Clinical Relevance: Plate/screw or screws would likely be similarly effective in fusing the talonavicular joint. However, the fusion induced lateralization of plantar pressures may unintentionally result in adjacent joint arthritis and foot pain.
- 1 February 2009
- Published by SAGE Publications in Foot & Ankle International
- Vol. 30 (2) , 150-156
Biomechanical Comparison of Screw Versus Plate/Screw Construct for Talonavicular Fusion
Background: Talonavicular fusion is performed for a variety of indications. This study examined the effects of fixation techniques on plantar pressures, construct stiffness, and strength. Materials and Methods: Eight matched pairs of cadaveric lower extremities were axially loaded intact and after talonavicular fixation with a 3.5 reconstruction plate, reconstruction plate plus cancellous screw (plate/screw), or three screws (screws). Recorded plantar pressures were divided into three forefoot, two midfoot, and two hindfoot regions. Cantilevered bending of excised constructs provided stiffness data for plantar and lateral directions, and failure characteristics in plantar bending. Results: Relative to the intact state, all fixations decreased peak pressure in the medial forefoot, while generally increasing it in the lateral forefoot and midfoot. Average pressure shifted laterally for all fixation methods in the forefoot, generally in the hindfoot and the lateral midfoot. Generally, contact areas decreased in the medial forefoot, midfoot, and hindfoot while increasing laterally in the midfoot and hindfoot. The only difference among fixation methods was a decreased medial midfoot contact area for screws. No differences were found between screws and plate/screw in bending stiffness or failure ( p < 0.5 and p < 0.2 respectively). Plantar and lateral bending stiffness for the plate/screw method averaged approximately 363 N/mm while stiffness of the screw only construct averaged approximately 380 N/mm. The load to failure averaged 946 N for the plate/screw construct and 1099 N for the screw construct. Conclusion: This study showed lateralization of plantar pressures following talonavicular fixation. Minimal differences were found between plate/screw and screws. Fixation across the joint may be key to achieving stability sufficient to resist shear and rotational stresses. Clinical Relevance: Plate/screw or screws would likely be similarly effective in fusing the talonavicular joint. However, the fusion induced lateralization of plantar pressures may unintentionally result in adjacent joint arthritis and foot pain.
- 20 January 2009
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 131 (4) , 044501
Bioreactor for Biaxial Mechanical Stimulation to Tissue Engineered Constructs
The complex structure and properties of biological tissues as well as their in situ environment often make it difficult to self-heal. A suitable replacement tissue may be created in vitro through tissue engineering approaches and mechanical stimulation of tissue constructs. A new biaxial bioreactor was designed, constructed, and evaluated for the purposes of developing constructs with specific functional characteristics. Once constructed and assembled, the bioreactor was tested for position accuracy and application of strain. Additionally, a tissue construct was tested in the chamber and compared with a nonstimulated construct. Results showed high position accuracy, but some loss between applied strain via grip movement and strain experienced by the scaffold. The tested construct exhibited an increase in cells and matrix deposition in comparison to the nonstimulated construct. This biaxial bioreactor will be useful for mechanically stimulating tissue constructs in two perpendicular directions to create implants for tissues requiring preferred compressive and tensile resistances.
- 20 January 2009
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 131 (4) , 044501
Bioreactor for Biaxial Mechanical Stimulation to Tissue Engineered Constructs
The complex structure and properties of biological tissues as well as their in situ environment often make it difficult to self-heal. A suitable replacement tissue may be created in vitro through tissue engineering approaches and mechanical stimulation of tissue constructs. A new biaxial bioreactor was designed, constructed, and evaluated for the purposes of developing constructs with specific functional characteristics. Once constructed and assembled, the bioreactor was tested for position accuracy and application of strain. Additionally, a tissue construct was tested in the chamber and compared with a nonstimulated construct. Results showed high position accuracy, but some loss between applied strain via grip movement and strain experienced by the scaffold. The tested construct exhibited an increase in cells and matrix deposition in comparison to the nonstimulated construct. This biaxial bioreactor will be useful for mechanically stimulating tissue constructs in two perpendicular directions to create implants for tissues requiring preferred compressive and tensile resistances.
- 1 November 2007
- Published by SAGE Publications in Foot & Ankle International
- Vol. 28 (11) , 1143-1153
Plantar Pressure Analysis in Cadaver Feet After Bony Procedures Commonly Used in the Treatment of Stage II Posterior Tibial Tendon Insufficiency
Background: Bony procedures play an essential role in the operative treatment of stage II posterior tibial tendon insufficiency and often substantially alter the loading characteristics of the foot. Methods: Eight matched pairs of cadaver lower extremities were axially loaded onto a TekScan HR Mat. (TekScan, Inc., South Boston, MA) After intact testing, each specimen had a lateral column lengthening (either a calcaneocuboid distraction arthrodesis [CCDA] or Evans procedure), a medializing calcaneal osteotomy (MCO), and a plantarflexion (Cotton) osteotomy of the medial cuneiform. The measured plantar pressures were divided into three forefoot regions, two midfoot regions, and two hindfoot regions. For each region, average pressure, peak pressure, and contact area data were collected. Results: Despite the fact that both lateral column lengthening procedures resulted in increased lateral forefoot pressures, no significant differences were noted between the CCDA and the Evans procedure. The addition of a MCO did not significantly alter the plantar pressures measured after the lateral column lengthening alone. Although the Cotton osteotomy resulted in increased average pressures within the medial forefoot, a compensatory significant decrease in lateral forefoot pressures was not observed. Conclusions: The present study demonstrated increased lateral forefoot pressures after a combined lateral column lengthening and MCO and does not support the idea that a Cotton osteotomy significantly reduces loading of the lateral forefoot. Clinical Relevance: The incidence of lateral forefoot pain and fifth metatarsal stress fractures subsequent to either lateral column lengthening procedure may not significantly decline after a Cotton osteotomy.
- 1 November 2007
- Published by SAGE Publications in Foot & Ankle International
- Vol. 28 (11) , 1143-1153
Plantar Pressure Analysis in Cadaver Feet After Bony Procedures Commonly Used in the Treatment of Stage II Posterior Tibial Tendon Insufficiency
Background: Bony procedures play an essential role in the operative treatment of stage II posterior tibial tendon insufficiency and often substantially alter the loading characteristics of the foot. Methods: Eight matched pairs of cadaver lower extremities were axially loaded onto a TekScan HR Mat. (TekScan, Inc., South Boston, MA) After intact testing, each specimen had a lateral column lengthening (either a calcaneocuboid distraction arthrodesis [CCDA] or Evans procedure), a medializing calcaneal osteotomy (MCO), and a plantarflexion (Cotton) osteotomy of the medial cuneiform. The measured plantar pressures were divided into three forefoot regions, two midfoot regions, and two hindfoot regions. For each region, average pressure, peak pressure, and contact area data were collected. Results: Despite the fact that both lateral column lengthening procedures resulted in increased lateral forefoot pressures, no significant differences were noted between the CCDA and the Evans procedure. The addition of a MCO did not significantly alter the plantar pressures measured after the lateral column lengthening alone. Although the Cotton osteotomy resulted in increased average pressures within the medial forefoot, a compensatory significant decrease in lateral forefoot pressures was not observed. Conclusions: The present study demonstrated increased lateral forefoot pressures after a combined lateral column lengthening and MCO and does not support the idea that a Cotton osteotomy significantly reduces loading of the lateral forefoot. Clinical Relevance: The incidence of lateral forefoot pain and fifth metatarsal stress fractures subsequent to either lateral column lengthening procedure may not significantly decline after a Cotton osteotomy.
- 1 July 2007
- Published by SAGE Publications in Foot & Ankle International
- Vol. 28 (7) , 823-830
External Fixation in the Treatment of Tibial Pilon Fractures: Comparison of Two Frames in Torsion
Background: Ankle spanning external fixation has become the initial treatment of choice for complex tibial pilon fractures. Many fixator designs exist, but their biomechanical performance has not been studied extensively for this application. The goal of the present study was to compare the torsional performance of two commercially available frames, the Orthofix XCaliber and the Howmedica Hoffmann® II. Methods: The XCaliber and the Hoffmann® II were each applied to six fresh cadaver lower extremities and were loaded in a materials testing machine. Strain gauges were attached to the anteromedial cortex of the distal tibia, and each specimen underwent torsional and axial load testing, with and without the external fixator. A simulated pilon fracture was created, and torsional testing was repeated. Results: Results indicated that the XCaliber was significantly more rigid in internal rotation than the Hoffmann® II, before (49%) and after (41%) creation of the pilon fracture. Despite the XCaliber's increased rigidity relative to the Hoffmann® II (22% to 31%) in external rotation, statistical significance was not attained. Both fixators reduced strain (25% to 85%) at the anteromedial cortex upon torsional testing, but no significant differences between the two frames were noted. Conclusions: The present study demonstrates that the XCaliber has mechanical advantages over the Hoffmann® II in terms of torsional rigidity for a tibial pilon fracture. Clinical Relevance: Increased rigidity of the XCaliber could potentially lead to decreased time to union, and a lower incidence of pin loosening and would prove beneficial in a setting in which the external fixator is used as the definitive fixation.
- 1 July 2007
- Published by SAGE Publications in Foot & Ankle International
- Vol. 28 (7) , 823-830
External Fixation in the Treatment of Tibial Pilon Fractures: Comparison of Two Frames in Torsion
Background: Ankle spanning external fixation has become the initial treatment of choice for complex tibial pilon fractures. Many fixator designs exist, but their biomechanical performance has not been studied extensively for this application. The goal of the present study was to compare the torsional performance of two commercially available frames, the Orthofix XCaliber and the Howmedica Hoffmann® II. Methods: The XCaliber and the Hoffmann® II were each applied to six fresh cadaver lower extremities and were loaded in a materials testing machine. Strain gauges were attached to the anteromedial cortex of the distal tibia, and each specimen underwent torsional and axial load testing, with and without the external fixator. A simulated pilon fracture was created, and torsional testing was repeated. Results: Results indicated that the XCaliber was significantly more rigid in internal rotation than the Hoffmann® II, before (49%) and after (41%) creation of the pilon fracture. Despite the XCaliber's increased rigidity relative to the Hoffmann® II (22% to 31%) in external rotation, statistical significance was not attained. Both fixators reduced strain (25% to 85%) at the anteromedial cortex upon torsional testing, but no significant differences between the two frames were noted. Conclusions: The present study demonstrates that the XCaliber has mechanical advantages over the Hoffmann® II in terms of torsional rigidity for a tibial pilon fracture. Clinical Relevance: Increased rigidity of the XCaliber could potentially lead to decreased time to union, and a lower incidence of pin loosening and would prove beneficial in a setting in which the external fixator is used as the definitive fixation.
- 3 May 2007
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 129 (6) , 811-817
Computational Modeling to Predict Mechanical Function of Joints: Application to the Lower Leg With Simulation of Two Cadaver Studies
Computational models of musculoskeletal joints and limbs can provide useful information about joint mechanics. Validated models can be used as predictive devices for understanding joint function and serve as clinical tools for predicting the outcome of surgical procedures. A new computational modeling approach was developed for simulating joint kinematics that are dictated by bone/joint anatomy, ligamentous constraints, and applied loading. Three-dimensional computational models of the lower leg were created to illustrate the application of this new approach. Model development began with generating three-dimensional surfaces of each bone from CT images and then importing into the three-dimensional solid modeling software SOLIDWORKS and motion simulation package COSMOSMOTION. Through SOLIDWORKS and COSMOSMOTION, each bone surface file was filled to create a solid object and positioned necessary components added, and simulations executed. Three-dimensional contacts were added to inhibit intersection of the bones during motion. Ligaments were represented as linear springs. Model predictions were then validated by comparison to two different cadaver studies, syndesmotic injury and repair and ankle inversion following ligament transection. The syndesmotic injury model was able to predict tibial rotation, fibular rotation, and anterior/posterior displacement. In the inversion simulation, calcaneofibular ligament extension and angles of inversion compared well. Some experimental data proved harder to simulate accurately, due to certain software limitations and lack of complete experimental data. Other parameters that could not be easily obtained experimentally can be predicted and analyzed by the computational simulations. In the syndesmotic injury study, the force generated in the tibionavicular and calcaneofibular ligaments reduced with the insertion of the staple, indicating how this repair technique changes joint function. After transection of the calcaneofibular ligament in the inversion stability study, a major increase in force was seen in several of the ligaments on the lateral aspect of the foot and ankle, indicating the recruitment of other structures to permit function after injury. Overall, the computational models were able to predict joint kinematics of the lower leg with particular focus on the ankle complex. This same approach can be taken to create models of other limb segments such as the elbow and wrist. Additional parameters can be calculated in the models that are not easily obtained experimentally such as ligament forces, force transmission across joints, and three-dimensional movement of all bones. Muscle activation can be incorporated in the model through the action of applied forces within the software for future studies.
- 3 May 2007
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 129 (6) , 811-817
Computational Modeling to Predict Mechanical Function of Joints: Application to the Lower Leg With Simulation of Two Cadaver Studies
Computational models of musculoskeletal joints and limbs can provide useful information about joint mechanics. Validated models can be used as predictive devices for understanding joint function and serve as clinical tools for predicting the outcome of surgical procedures. A new computational modeling approach was developed for simulating joint kinematics that are dictated by bone/joint anatomy, ligamentous constraints, and applied loading. Three-dimensional computational models of the lower leg were created to illustrate the application of this new approach. Model development began with generating three-dimensional surfaces of each bone from CT images and then importing into the three-dimensional solid modeling software SOLIDWORKS and motion simulation package COSMOSMOTION. Through SOLIDWORKS and COSMOSMOTION, each bone surface file was filled to create a solid object and positioned necessary components added, and simulations executed. Three-dimensional contacts were added to inhibit intersection of the bones during motion. Ligaments were represented as linear springs. Model predictions were then validated by comparison to two different cadaver studies, syndesmotic injury and repair and ankle inversion following ligament transection. The syndesmotic injury model was able to predict tibial rotation, fibular rotation, and anterior/posterior displacement. In the inversion simulation, calcaneofibular ligament extension and angles of inversion compared well. Some experimental data proved harder to simulate accurately, due to certain software limitations and lack of complete experimental data. Other parameters that could not be easily obtained experimentally can be predicted and analyzed by the computational simulations. In the syndesmotic injury study, the force generated in the tibionavicular and calcaneofibular ligaments reduced with the insertion of the staple, indicating how this repair technique changes joint function. After transection of the calcaneofibular ligament in the inversion stability study, a major increase in force was seen in several of the ligaments on the lateral aspect of the foot and ankle, indicating the recruitment of other structures to permit function after injury. Overall, the computational models were able to predict joint kinematics of the lower leg with particular focus on the ankle complex. This same approach can be taken to create models of other limb segments such as the elbow and wrist. Additional parameters can be calculated in the models that are not easily obtained experimentally such as ligament forces, force transmission across joints, and three-dimensional movement of all bones. Muscle activation can be incorporated in the model through the action of applied forces within the software for future studies.
- 28 February 2006
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 5 (2-3) , 102-110
Influence of a Superficial Tangential Zone Over Repairing Cartilage Defects: Implications for Tissue Engineering
The superficial tangential zone (STZ) plays a critical role in normal cartilage function but is not yet a focus for designing tissue-engineered constructs for cartilage repair. Without material properties of sufficient quality in this zone, transplanted constructs in vivo may have little chance of survival. This finite element study investigates the impact of the superficial tangential zone on the mechanical function of normal articular surfaces as well as those with transplanted constructs. The zone is modeled as a thin transversely isotropic material with strain dependent permeability. The analyses predict that a normal transversely isotropic STZ placed over a repair region reduces the axial compression (55–68%) of, and the rate of fluid loss (45–82%) from the articular surface. A reduction was also found in von Mises stress (26–57%), axial strain (22–56%), and radial strain (69–73%), and an increase in fluid pressure (19–45%) in repair tissue under the STZ. Incorporating a quality superficial tangential zone in tissue-engineered constructs may be a critical factor in achieving mechanical environments conducive for successful cartilage repairs.
- 28 February 2006
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 5 (2-3) , 102-110
Influence of a Superficial Tangential Zone Over Repairing Cartilage Defects: Implications for Tissue Engineering
The superficial tangential zone (STZ) plays a critical role in normal cartilage function but is not yet a focus for designing tissue-engineered constructs for cartilage repair. Without material properties of sufficient quality in this zone, transplanted constructs in vivo may have little chance of survival. This finite element study investigates the impact of the superficial tangential zone on the mechanical function of normal articular surfaces as well as those with transplanted constructs. The zone is modeled as a thin transversely isotropic material with strain dependent permeability. The analyses predict that a normal transversely isotropic STZ placed over a repair region reduces the axial compression (55–68%) of, and the rate of fluid loss (45–82%) from the articular surface. A reduction was also found in von Mises stress (26–57%), axial strain (22–56%), and radial strain (69–73%), and an increase in fluid pressure (19–45%) in repair tissue under the STZ. Incorporating a quality superficial tangential zone in tissue-engineered constructs may be a critical factor in achieving mechanical environments conducive for successful cartilage repairs.
- 1 May 2005
- Published by SAGE Publications in Tissue Engineering
- Vol. 11 (5-6) , 953-963
In Vivo Response of Polylactic Acid–Alginate Scaffolds and Bone Marrow-Derived Cells for Cartilage Tissue Engineering
Successful application of tissue-engineering techniques to damaged biological structures is determined by functional performance in vivo. This study evaluated the in vivo response of a tissue-engineered construct composed of a polylactic acid–alginate amalgam seeded with bone marrow-derived mesenchymal stem cells and stimulated in vitro with transforming growth factor β for cartilage tissue engineering. Constructs were placed in cylindrical osteochondral defects in the canine femoral condyle and examined 6 weeks postoperatively by gross, histological, immunohistochemical, and biomechanical analyses. In the course of 6 weeks in vivo, the defects filled with a cartilaginous tissue regardless of whether cell-seeded (experimental) or cell-free (control) constructs were implanted; however, the quality of the tissue differed between the experimental and control defects. Cell-seeded experimental defects showed more cartilage-like matrix quality, cell distribution, and proteoglycan staining. Biomechanically, experimental and control specimens exhibited similar behavior; however, both tissues were still immature compared with normal cartilage. The evidence accumulated in this study showed a modest acceleration of the in vivo healing of cellseeded constructs but also demonstrated a reparative response of cell-free constructs. This finding suggests that the constructs prepared from the PLA–alginate amalgam may serve as a means for host cell attachment.
- 1 May 2005
- Published by SAGE Publications in Tissue Engineering
- Vol. 11 (5-6) , 953-963
In Vivo Response of Polylactic Acid–Alginate Scaffolds and Bone Marrow-Derived Cells for Cartilage Tissue Engineering
Successful application of tissue-engineering techniques to damaged biological structures is determined by functional performance in vivo. This study evaluated the in vivo response of a tissue-engineered construct composed of a polylactic acid–alginate amalgam seeded with bone marrow-derived mesenchymal stem cells and stimulated in vitro with transforming growth factor β for cartilage tissue engineering. Constructs were placed in cylindrical osteochondral defects in the canine femoral condyle and examined 6 weeks postoperatively by gross, histological, immunohistochemical, and biomechanical analyses. In the course of 6 weeks in vivo, the defects filled with a cartilaginous tissue regardless of whether cell-seeded (experimental) or cell-free (control) constructs were implanted; however, the quality of the tissue differed between the experimental and control defects. Cell-seeded experimental defects showed more cartilage-like matrix quality, cell distribution, and proteoglycan staining. Biomechanically, experimental and control specimens exhibited similar behavior; however, both tissues were still immature compared with normal cartilage. The evidence accumulated in this study showed a modest acceleration of the in vivo healing of cellseeded constructs but also demonstrated a reparative response of cell-free constructs. This finding suggests that the constructs prepared from the PLA–alginate amalgam may serve as a means for host cell attachment.
- 1 February 2004
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 7 (1) , 17-23
Influence of Aspect Ratios on the Creep Behaviour of Articular Cartilage in Indentation
Indentation tests are commonly used to determine the mechanical behaviour of articular cartilage with varying properties, thickness, and geometry. This investigation evaluated the effect of changing geometric parameters on the properties determined from creep indentation tests. Finite element analyses simulated the indentation behaviour of two models, an excised cylindrical specimen of cartilage with either normal and repair qualities and an osteochondral defect represented as a cylindrical region of repair cartilage integrated with a surrounding layer of normal tissue. For each model, the ratios of indenter radius to cartilage height and cartilage radius to indenter radius were varied. The vertical displacement of the cartilage under the indenter obtained through finite element analysis was fitted to a numerical algorithm to determine the aggregate modulus, permeability, and Poisson's ratio. Indentation behaviours of cartilage specimens for either model with were not affected by for values of 2 and 5. Aggregate modulus was not greatly affected by the geometric changes studied. Permeability was affected by changes in the ratio of specimen to indenter radii for These findings suggest that experimental configurations of excised cylindrical specimens, also representing osteochondral defects with no or unknown degree of integration, where the cartilage layer has should not have r/a values on the order of 2 for confidence in the mechanical properties determined. Indentation of osteochondral defects where the repair cartilage is fully integrated to the surrounding cartilage can be performed with confidence for all cases tested.
- 1 February 2004
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 7 (1) , 17-23
Influence of Aspect Ratios on the Creep Behaviour of Articular Cartilage in Indentation
Indentation tests are commonly used to determine the mechanical behaviour of articular cartilage with varying properties, thickness, and geometry. This investigation evaluated the effect of changing geometric parameters on the properties determined from creep indentation tests. Finite element analyses simulated the indentation behaviour of two models, an excised cylindrical specimen of cartilage with either normal and repair qualities and an osteochondral defect represented as a cylindrical region of repair cartilage integrated with a surrounding layer of normal tissue. For each model, the ratios of indenter radius to cartilage height and cartilage radius to indenter radius were varied. The vertical displacement of the cartilage under the indenter obtained through finite element analysis was fitted to a numerical algorithm to determine the aggregate modulus, permeability, and Poisson's ratio. Indentation behaviours of cartilage specimens for either model with were not affected by for values of 2 and 5. Aggregate modulus was not greatly affected by the geometric changes studied. Permeability was affected by changes in the ratio of specimen to indenter radii for These findings suggest that experimental configurations of excised cylindrical specimens, also representing osteochondral defects with no or unknown degree of integration, where the cartilage layer has should not have r/a values on the order of 2 for confidence in the mechanical properties determined. Indentation of osteochondral defects where the repair cartilage is fully integrated to the surrounding cartilage can be performed with confidence for all cases tested.
- 1 August 2003
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 228 (2) , 493-499
MR Imaging of Normal and Matrix-depleted Cartilage: Correlation with Biomechanical Function and Biochemical Composition
To correlate articular cartilage function, as reflected in biomechanical properties and biochemical composition, with magnetic resonance (MR) imaging parameters of normal articular cartilage and cartilage partially depleted of matrix components. Normal articular cartilage from 12 porcine patellae was evaluated biomechanically, biochemically, and with MR imaging (with and without gadolinium enhancement). The patellae were then enzymatically treated to deplete the matrix of either collagen or proteoglycan and then reevaluated biomechanically, biochemically, and with MR imaging. Correlations between cartilaginous tissue function and MR imaging parameters were made. Analysis of variance was performed to assess the effect of enzymatic treatment on measured parameters. Linear correlations among the MR imaging, biochemical, and biomechanical parameters were performed to determine the strengths of the relationships. P <.05 indicated statistically significant differences. Biochemical, biomechanical, and MR analyses enabled detection of changes caused by matrix depletion (P <.05). T2 was the most useful MR imaging parameter for distinguishing proteoglycan loss from collagen loss. T2 correlated significantly with both biomechanical modulus (indicative of cartilage stiffness; P <.001, R2 = 0.51) and biochemical proteoglycan content (P <.001, R2 = 0.44). Differentiation between proteoglycan loss and collagen loss in terms of T1 improved with gadolinium enhancement. With gadolinium enhancement, proteoglycan depletion was associated with a greater decrease in T1 than collagen depletion (P <.05). An association between biochemical and biomechanical functional status and MR imaging parameters of articular cartilage was demonstrated. Linear correlations existed between modulus and proteoglycan content in terms of T2. Additionally, proteoglycan loss and collagen loss had differing effects on gadolinium-enhanced T1 when it was expressed as the ratio of T1 after gadolinium enhancement/T1 before gadolinium enhancement.
- 1 August 2003
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 228 (2) , 493-499
MR Imaging of Normal and Matrix-depleted Cartilage: Correlation with Biomechanical Function and Biochemical Composition
To correlate articular cartilage function, as reflected in biomechanical properties and biochemical composition, with magnetic resonance (MR) imaging parameters of normal articular cartilage and cartilage partially depleted of matrix components. Normal articular cartilage from 12 porcine patellae was evaluated biomechanically, biochemically, and with MR imaging (with and without gadolinium enhancement). The patellae were then enzymatically treated to deplete the matrix of either collagen or proteoglycan and then reevaluated biomechanically, biochemically, and with MR imaging. Correlations between cartilaginous tissue function and MR imaging parameters were made. Analysis of variance was performed to assess the effect of enzymatic treatment on measured parameters. Linear correlations among the MR imaging, biochemical, and biomechanical parameters were performed to determine the strengths of the relationships. P <.05 indicated statistically significant differences. Biochemical, biomechanical, and MR analyses enabled detection of changes caused by matrix depletion (P <.05). T2 was the most useful MR imaging parameter for distinguishing proteoglycan loss from collagen loss. T2 correlated significantly with both biomechanical modulus (indicative of cartilage stiffness; P <.001, R2 = 0.51) and biochemical proteoglycan content (P <.001, R2 = 0.44). Differentiation between proteoglycan loss and collagen loss in terms of T1 improved with gadolinium enhancement. With gadolinium enhancement, proteoglycan depletion was associated with a greater decrease in T1 than collagen depletion (P <.05). An association between biochemical and biomechanical functional status and MR imaging parameters of articular cartilage was demonstrated. Linear correlations existed between modulus and proteoglycan content in terms of T2. Additionally, proteoglycan loss and collagen loss had differing effects on gadolinium-enhanced T1 when it was expressed as the ratio of T1 after gadolinium enhancement/T1 before gadolinium enhancement.
- 8 June 2001
- Vol. 38 (2) , 191-200
Long-term survival of regenerated cartilage on a large joint surface.
The one-year survival of regenerated cartilage on a large articular surface is presented using the McDowell in vivo model. The model provides a mechanically shielded environment in which regenerated cartilage can be protected from intra-articular stresses while normal joint motion is maintained. New tissue was allowed to grow from bleeding subchondral bone for 12 weeks at which time the original mechanical environment was reintroduced. Our study showed that neo-cartilage would grow to cover the entire joint surface of a patella and could survive for one year. Histologic observations indicated a maturing hyaline-like tissue. Biomechanical analyses showed that the regenerated cartilage became stiffer and less permeable within the time of this study. Biochemical evaluations demonstrated stable properties out to the longest time point. Control specimens, which were not shielded from stress, showed insignificant amounts of new tissue growing on the patellar surfaces.
- 8 June 2001
- Vol. 38 (2) , 191-200
Long-term survival of regenerated cartilage on a large joint surface.
The one-year survival of regenerated cartilage on a large articular surface is presented using the McDowell in vivo model. The model provides a mechanically shielded environment in which regenerated cartilage can be protected from intra-articular stresses while normal joint motion is maintained. New tissue was allowed to grow from bleeding subchondral bone for 12 weeks at which time the original mechanical environment was reintroduced. Our study showed that neo-cartilage would grow to cover the entire joint surface of a patella and could survive for one year. Histologic observations indicated a maturing hyaline-like tissue. Biomechanical analyses showed that the regenerated cartilage became stiffer and less permeable within the time of this study. Biochemical evaluations demonstrated stable properties out to the longest time point. Control specimens, which were not shielded from stress, showed insignificant amounts of new tissue growing on the patellar surfaces.