YOYukihiro Ozaki

Yukihiro Ozaki

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yukihiro Ozaki has a total of 30 co-authors. Here are the top co-authors by number of shared publications:

  • Sumaporn Kasemsumran

    Department of Chemistry and Research Center for Near-Infrared Spectroscopy, School of Science and Technology, Kwansei-Gakuin University, Gakuen, Sanda, Hyogo 669-1337, Japan

    4 shared publications
  • Bing Zhao

    Key Laboratory for Supermolecular Structure and Materials of Ministry of Education, Jilin University, Changchun 130023, PR China

    3 shared publications
  • Bofu Li

    Key Laboratory for Supermolecular Structure and Materials of Ministry of Education, Jilin University, Changchun 130023, PR China

    3 shared publications
  • Huiying Jia

    Key Laboratory for Supermolecular Structure and Materials of Ministry of Education, Jilin University, Changchun 130023, PR China

    3 shared publications
  • Koichi Murayama

    Department of Biochemistry and Biophysics, Gifu University School of Medicine, Gifu 500-8705, Japan

    3 shared publications
  • Weiqing Xu

    Key Laboratory for Supermolecular Structure and Materials of Ministry of Education, Jilin University, Changchun 130023, PR China

    3 shared publications

Latest Publications

  • Perturbation-Correlation Moving-Window Two-Dimensional Correlation Spectroscopy

    by Shigeaki Morita, Hideyuki Shinzawa, Isao Noda, Yukihiro Ozaki

    A new method of analysis, perturbation-correlation moving-window two-dimensional (PCMW2D) correlation spectroscopy, is proposed. For a spectral data set collected under an external perturbation, this method provides a pair of synchronous and asynchronous two-dimensional correlation spectra plotted on a plane between a spectral variable (e.g., wavenumber) axis and a perturbation variable (e.g., temperature) axis. One of the advantages of this new correlation analysis method is that complicated spectral variation along the perturbation direction can be monitored. It has been found that the synchronous and asynchronous PCMW2D correlation spectra are similar to the first perturbation derivative and negative second perturbation derivative spectra of the original data, respectively. To demonstrate the potential of PCMW2D correlation spectroscopy, it has been applied to temperature-dependent infrared (IR) spectra of a poly(vinyl alcohol) (PVA) film. The thermal behavior of the PVA film has been revealed by the PCMW2D correlation analysis. Two characteristic cross-peaks are observed in the synchronous PCMW2D correlation spectra generated from the temperature-dependent IR spectra between the crystalline phase C–O stretching band at 1141 cm −1 and the melting temperature of 209 °C and between the amorphous phase C–O stretching band at 1095 cm −1 and another specific temperature of 233 °C. This specific temperature of 233 °C corresponds to the thermal degradation temperature due to the elimination of the hydroxyl group attached to the main chain.


  • Moving window cross validation: a new cross validation method for the selection of a rational number of components in a partial least squares calibration model

    by Sumaporn Kasemsumran, Yi-Ping Du, Bo-Yan Li, Katsuhiko Maruo, Yukihiro Ozaki

    A new cross validation method called moving window cross validation (MWCV) is proposed in this study, as a novel method for selecting the rational number of components for building an efficient calibration model in analytical chemistry. This method works with an innovative pattern to split a validation set by a number of given windows that move synchronously along proper subsets of all the samples. Calculations for the mean value of all mean squares error in cross validations (MSECVs) for all splitting forms are made for different numbers of components, and then the optimal number of components for the model can be selected. Performance of MWCV is compared with that of two cross validation methods, leave-one-out cross validation (LOOCV) and Monte Carlo cross validation (MCCV), for partial least squares (PLS) models developed on one simulated data set and two real near-infrared (NIR) spectral data sets. The results reveal that MWCV can avoid a tendency to over-fit the data. Selection of the optimal number of components can be easily made by MWCV because it yields a global minimum in root MSECV at the optimal number of components. Changes in the window size and window number of MWCV do not greatly influence the selection of the number of components. MWCV is demonstrated to be an effective, simple and accurate cross validation method.


  • Partial Least Squares Processing of Near‐Infrared Spectra for Discrimination and Quantification of Adulterated Olive Oils

    by Sumaporn Kasemsumran, Naroo Kang, Alfred Christy, Yukihiro Ozaki

    A new processing based on partial least squares (PLS) algorithm for the discrimination and determination of adulterants in pure olive oil using near‐infrared (NIR) spectroscopy has been introduced. The 280 adulterations of olive oil with corn oil (n=70), hazelnut oil (n=70), soya oil (n=70), and sunflower oil (n=70) were prepared, and their NIR spectra in the region 12,000–4550 cm−1 were collected. The 70 spectra of each adulteration of olive oil were divided into two sets, 50 spectra for a calibration set and 20 spectra for a prediction set. The spectra of a total calibration set (n=200) were separated into individual adulterant calibration sets (ni=50, i=corn, hazelnut, soya, sunflower) by using discriminant PLS (DPLS) analysis, and PLS calibration models for the quantification of adulterants with corn oil, hazelnut oil, soya oil, or sunflower oil were developed separately. A variety of wavelength ranges and data pretreatments were examined for obtaining optimal results for the discrimination and quantification objects. Four PLS models for differentiating the adulterant types were evaluated by classifying the NIR spectra of a total prediction set (n=80) into known adulterant types. Then, these known adulterant spectra were analyzed by the PLS calibration models developed for each type to determine the content of an adulterant in pure olive oil. The results of evaluation revealed that the processing reported in this article works excellently for the discrimination and quantification of the adulterations of olive oil.


  • Determination of total nitrogen content, pH, density, refractive index, and brix in Thai fish sauces and their classification by near-infrared spectroscopy with searching combination moving window partial least squares

    by Pitiporn Ritthiruangdej, Sumaporn Kasemsumran, Thongchai Suwonsichon, Vichai Haruthaithanasan, Warunee Thanapase, Yukihiro Ozaki

    Near-infrared (NIR) transflectance spectra in the region of 1100–2500 nm were measured for 100 Thai fish sauces. Quantitative analyses of total nitrogen (TN) content, pH, refractive index, density and brix in the Thai fish sauces and their qualitative analyses were carried out by multivariate analyses with the aid of wavelength interval selection method named searching combination moving window partial least squares (SCMWPLS). The optimized informative region for TN selected by SCMWPLS was the region of 2264–2428 nm. A PLS calibration model, which used this region, yielded the lowest root mean square error of prediction (RMSEP) of 0.100% w/v for the PLS factor of 5. This prediction result is significantly better than those obtained by using the whole spectral region or informative regions selected by moving window partial least squares regression (MWPLSR). As for pH, density, refractive index and brix, the 1698–1722, and 2222–2258 nm regions, the 1358–1438 nm region, the 1774–1846, and 2078–2114 nm regions, and the 1322–1442, and 2000–2076 nm regions were selected by SCMWPLS as the optimized regions. The best prediction results were always obtained by use of the optimized regions selected by SCMWPLS. The lowest RMSEP for pH, density, refractive index and brix were 0.170, 0.007 g cm−3, 0.0079 and 0.435° Brix, respectively. Qualitative models were developed by using four supervised pattern recognitions, linear discriminant analysis (LDA), factor analysis-linear discriminant analysis (FA-LDA), soft independent modeling of class analog (SIMCA), and K neareat neighbors (KNN) for the optimized combination of informative regions of the NIR spectra of fish sauces to classify fish sauces into three groups based on TN. All the developed models can potentially classify the fish sauces with the correct classification rate of more than 82%, and the KNN classified model has the highest correct classification rate (95%). The present study has demonstrated that NIR spectroscopy combined with SCMWPLS is powerful for both the quantitative and qualitative analyses of Thai fish sauces.


  • Prediction of Ethylene Content in Melt-State Random and Block Polypropylene by Near-Infrared Spectroscopy and Chemometrics: Influence of a Change in Sample Temperature and its Compensation Method

    by Masahiro Watari, Yukihiro Ozaki

    This paper reports on the influence of a change in sample temperature, and a method for its compensation, for the prediction of ethylene (C 2 ) content in melt-state random polypropylene (RPP) and block polypropylene (BPP) by near-infrared (NIR) spectroscopy and chemometrics. Near-infrared (NIR) spectra of RPP in the melt and solid states were measured by a Fourier transform near-infrared (FT-NIR) on-line monitoring system and an FT-NIR laboratory system. There are some significant differences between the solid- and melt-state RPP spectra. Moreover, we investigated the predicted values of the C 2 content from the RPP or BPP spectra measured at 190 °C and 250 °C using the calibration model for the C 2 content developed using the RPP or BPP spectra measured at 230 °C. The errors in the predicted values of the C 2 content depend on the pretreatment methods for each calibration model. It was found that multiplicative signal correction (MSC) is very effective in compensating for the influence of the change of temperature for the RPP or BPP samples on the predicted C 2 content. From the suggestion of principal component analysis (PCA) and difference spectrum analysis, we propose a new compensation method for the temperature change that uses the difference spectra between two spectra sets measured at different temperatures. We achieved good results using the difference spectra between the RPP/BPP spectra sets measured at 190 °C and 250 °C after correction and the calibration model developed with the spectra measured at 230 °C. The comparison between the method using MSC and the proposed method showed that the predicted error in the latter is slightly better than those in the former.


  • Mechanism of Thermal Phase Transition of a Ferroelectric Liquid Crystal with Monotropic Transition Temperature Studied by Infrared Spectroscopy Combined with Principal Component Analysis and Sample—Sample Two-Dimensional Correlation Spectroscopy

    by Jinggang Zhao, Kenji Tatani, Yukihiro Ozaki

    Infrared (IR) spectra of FLC-154 (FLC: ferroelectric liquid crystal) with monotropic phase transition under a nonalignment state with a sample layer thickness of 24.5 μm were measured for heating process from 55 to 90 °C and a cooling process from 90 to 55 °C in increments of 1 °C. The thermal dynamics of FLC-154 were investigated by use of IR spectroscopy combined with principal component analysis (PCA) and sample–sample two-dimensional (2D) correlation spectroscopy. During the cooling, the FLC-154 molecule passes through the monotropic smectic- C* (Sm- C*) phase, which is transformed from the Sm- A phase. The results from PCA suggest that during the heating process, the thermal dynamics of the alkyl chains, core moiety, and C=O groups are similar to each other. Furthermore, PCA and sample–sample 2D correlation spectroscopy indicate that the alkyl chains and C=O groups in the chiral and core moieties are responsible for the emergence of the Sm- C* phase. This conclusion is very important because the IR data have given more evident cause for the emergence of the Sm- C* phase than the theoretical models such as the molecular-statistical theory of ferroelectric ordering and the indigenous polarization theory. Moreover, it has been found that some of the trans conformations of the alkyl chains of FLC-154 change partly to the gauche conformation when the phase transition from the crystalline phase to the Sm- A phase occurs. It has also been found that the intermolecular interactions of the C=O group in the core moiety in the Sm- A phase are weaker than those in the crystalline phase and that the conformational change occurs on the C–O–C bonds in the core moiety upon going from the crystalline to the Sm- A phase.


  • An Infrared Spectroscopy Study of Acid Stability and Thermal Unfolding Process of Granulocyte-Colony Stimulating Factor

    by Katsuyoshi Yamazaki, Koichi Murayama, Rika Ishikawa, Yukihiro Ozaki

    Temperature-dependent (25–80°C) infrared (IR) spectra were obtained for recombinant methionyl human granulocyte-colony stimulating factor (rmethuG-CSF) in aqueous solutions over the pD range of 5.5–2.1 to investigate its thermal stability at various pDs. Second derivative, Fourier self-deconvolution, and curve-fitting analyses were performed to analyze the obtained spectra. These spectral analyses demonstrated that in the thermal unfolding process the α-helix structure of rmethuG-CSF partially changes to an unordered structure and then the unordered structure forms aggregates. The temperature-dependent IR spectra revealed that the structure of rmethuG-CSF is the most stable at pD 2.5 in the pD range of 5.5–2.1. It has been suggested that the unordered structure formed before the marked structural change in the whole molecule is a perturbed form of the native structure of rmethuG-CSF and plays a role as a precursor for the aggregation. This alteration to the perturbed form is likely to be the first secondary structure change that occurs along the aggregation pathway. Of particular note is that the stability at pD 2.1 is slightly lower than that at pD 2.5, but that aggregates are formed at higher temperature at pD 2.1 than at pD 2.5, probably because the repulsive interaction between the unordered structure is stronger at pD 2.1.


  • Prediction of Ethylene Content in Melt-State Random and Block Polypropylene by Near-Infrared Spectroscopy and Chemometrics: Comparison of a New Calibration Transfer Method with a Slope/Bias Correction Method

    by Masahiro Watari, Yukihiro Ozaki

    This paper reports the prediction of the ethylene content (C 2 content) in random polypropylene (RPP) and block polypropylene (BPP) in the melt state by near-infrared (NIR) spectroscopy and chemometrics. NIR spectra of RPP and BPP in the melt states were measured by a Fourier transform near-infrared (FT-NIR) on-line monitoring system. The NIR spectra of RPP and BPP were compared. Partial least-squares (PLS) regression calibration models predicting the ethylene (C 2 ) content that were developed by using each RPP or BPP spectra set separately yielded good results (SECV (standard error of cross validation): RPP, 0.16%; BPP, 0.31%; correlation coefficient: RPP, 0.998; BPP, 0.996). We also built a common PLS calibration model by using both the RPP and the BPP spectra set. The results showed that the common calibration model has larger SECV values than the models based on the RPP or the BPP spectra sets individually and is not practical for the prediction of the C 2 content. We further investigated whether a calibration model developed by using the BPP spectra set can predict the C 2 contents in the RPP sample set. If this is possible, it can save a significant amount of work and cost. The results showed that the use of the BPP model for the RPP sample set is difficult, and vice versa, because there are some differences in the molar absorption coefficients between the RPP and BPP spectra. To solve this problem, a transfer method from one sample spectra (BPP) set to the other spectra (RPP) set was studied. A difference spectrum between an RPP spectrum and a BPP spectrum was used to transfer from the BPP calibration set to the RPP calibration set. The prediction result (SEP (standard error of prediction), 0.23%, correlation coefficient, 0.994) of RPP samples by the transferred calibration set and model showed that it is possible to transfer from the BPP calibration set to the RPP calibration set. We also studied the transfer from the RPP calibration set (the range of C 2 content: 0–4.3%) to the BPP calibration set. The prediction result of C 2 content (the range of C 2 contents: 0–7.7%) in BPP by use of the calibration model based on the transferred BPP spectra from the RPP spectra showed that the transfer method is only effective for the interpolation of the C 2 content range by the nonlinear change in the peak intensities with the C 2 content.