XWXujing Wang

Xujing Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xujing Wang has a total of 25 co-authors. Here are the top co-authors by number of shared publications:

  • Martin J. Hessner

    Department of Pediatrics, Medical College of Wisconsin, Milwaukee, Wisconsin, USA

    4 shared publications
  • Soumitra Ghosh

    Max McGee National Research Center for Juvenile Diabetes and Human and Molecular Genetics Center, Medical College of Wisconsin and Children’s Research Institute of the Children’s Hospital of Wisconsin, 8701 Watertown Plank Road, Milwaukee, WI 53226, United States

    3 shared publications
  • Nan Jiang

    Division of Fish Disease, Yangtze River Fisheries Research Institute, Chinese Academy of Fishery Sciences, Wuhan 430223, China

    2 shared publications
  • Soumitra Ghosh

    Department of Biochemistry, University of Lausanne, Epalinges, Switzerland

    2 shared publications
  • Bixia Xiang

    The Max McGee National Research Center for Juvenile Diabetes, Department of Pediatrics, The Medical College of Wisconsin and Children's Hospital of Wisconsin, 8701 Watertown Plank Road, Milwaukee, WI 53226, USA

    1 shared publication
  • Carol Moreno

    Department of Hematology, Hospital de la Santa Creu i Sant Pau, Autonomous University of Barcelona, Barcelona, Spain

    1 shared publication

Latest Publications

  • Open Access

    Comprehensive quality control utilizing the prehybridization third-dye image leads to accurate gene expression measurements by cDNA microarrays

    by Xujing Wang, Shuang Jia, Lisa Meyer, Bixia Xiang, Li-Yen Chen, Nan Jiang, Carol Moreno, Howard J Jacob, Soumitra Ghosh, Martin J Hessner

    Background Gene expression profiling using microarrays has become an important genetic tool. Spotted arrays prepared in academic labs have the advantage of low cost and high design and content flexibility, but are often limited by their susceptibility to quality control (QC) issues. Previously, we have reported a novel 3-color microarray technology that enabled array fabrication QC. In this report we further investigated its advantage in spot-level data QC. Results We found that inadequate amount of bound probes available for hybridization led to significant, gene-specific compression in ratio measurements, increased data variability, and printing pin dependent heterogeneities. The impact of such problems can be captured through the definition of quality scores, and efficiently controlled through quality-dependent filtering and normalization. We compared gene expression measurements derived using our data processing pipeline with the known input ratios of spiked in control clones, and with the measurements by quantitative real time RT-PCR. In each case, highly linear relationships (R2>0.94) were observed, with modest compression in the microarray measurements (correction factor<1.17). Conclusion Our microarray analytical and technical advancements enabled a better dissection of the sources of data variability and hence a more efficient QC. With that highly accurate gene expression measurements can be achieved using the cDNA microarray technology.


  • Open Access

    Immobilized probe and glass surface chemistry as variables in microarray fabrication

    by Martin J Hessner, Lisa Meyer, Jennifer Tackes, Sanaa Muheisen, Xujing Wang

    Background: Global gene expression studies with microarrays can offer biological insights never before possible. However, the technology possesses many sources of technical variability that are an obstacle to obtaining high quality data sets. Since spotted microarrays offer design/content flexibility and potential cost savings over commercial systems, we have developed prehybridization quality control strategies for spotted cDNA and oligonucleotide arrays. These approaches utilize a third fluorescent dye (fluorescein) to monitor key fabrication variables, such as print/spot morphology, DNA retention, and background arising from probe redistributed during blocking. Here, our labeled cDNA array platform is used to study, 1) compression of array data using known input ratios of Arabidopsis in vitro transcripts and arrayed serial dilutions of homologous probes; 2) how curing time of in-house poly-L-lysine coated slides impacts probe retention capacity; and 3) the retention characteristics of 13 commercially available surfaces. Results: When array element fluorescein intensity drops below 5,000 RFU/pixel, gene expression measurements become increasingly compressed, thereby validating this value as a prehybridization quality control threshold. We observe that the DNA retention capacity of in-house poly-L-lysine slides decreases rapidly over time (~50% reduction between 3 and 12 weeks post-coating; p < 0.0002) and that there are considerable differences in retention characteristics among commercially available poly-L-lysine and amino silane-coated slides. Conclusions: High DNA retention rates are necessary for accurate gene expression measurements. Therefore, an understanding of the characteristics and optimization of protocols to an array surface are prerequisites to fabrication of high quality arrays.


  • Open Access

    Utilization of a labeled tracking oligonucleotide for visualization and quality control of spotted 70-mer arrays

    by Martin J Hessner, Vineet K Singh, Xujing Wang, Shehnaz Khan, Michael R Tschannen, Thomas C Zahrt

    Spotted 70-mer oligonucleotide arrays offer potentially greater specificity and an alternative to expensive cDNA library maintenance and amplification. Since microarray fabrication is a considerable source of data variance, we previously directly tagged cDNA probes with a third fluorophore for prehybridization quality control. Fluorescently modifying oligonucleotide sets is cost prohibitive, therefore, a co-spotted Staphylococcus aureus-specific fluorescein-labeled "tracking" oligonucleotide is described to monitor fabrication variables of a Mycobacterium tuberculosis oligonucleotide microarray. Significantly (p < 0.01) improved DNA retention was achieved printing in 15% DMSO/1.5 M betaine compared to the vendor recommended buffers. Introduction of tracking oligonucleotide did not effect hybridization efficiency or introduce ratio measurement bias in hybridizations between M. tuberculosis H37Rv and M. tuberculosis mprA. Linearity between the mean log Cy3/Cy5 ratios of genes differentially expressed from arrays either possessing or lacking the tracking oligonucleotide was observed (R2 = 0.90, p < 0.05) and there were no significant differences in Pearson's correlation coefficients of ratio data between replicates possessing (0.72 ± 0.07), replicates lacking (0.74 ± 0.10), or replicates with and without (0.70 ± 0.04) the tracking oligonucleotide. ANOVA analysis confirmed the tracking oligonucleotide introduced no bias. Titrating target-specific oligonucleotide (40 μM to 0.78 μM) in the presence of 0.5 μM tracking oligonucleotide, revealed a fluorescein fluorescence inversely related to target-specific oligonucleotide molarity, making tracking oligonucleotide signal useful for quality control measurements and differentiating false negatives (synthesis failures and mechanical misses) from true negatives (no gene expression). This novel approach enables prehybridization array visualization for spotted oligonucleotide arrays and sets the stage for more sophisticated slide qualification and data filtering applications.


  • A novel approach for high-quality microarray processing using third-dye array visualization technology

    by Xujing Wang, Nan Jiang, Xin Feng, Yizhou Xie, P.J. Tonellato, S. Ghosh, M.J. Hessner

    Historically, microarray image processing has been technically challenging in obtaining quality gene expression data. After hybridization of Cy3- and Cy5-labeled samples, images are collected and processed to obtain gene expression ratio measurements for each of the elements on the array. The hybridization process often brings in contaminating noise, which can make correct identification of the signal difficult. In addition, spot intensity levels are highly variable due to the expression differences of different genes, and weak spots are often difficult to detect. These conditions are further complicated by inherent irregularities in spot position, shape, and size commonly found on high-density microarrays, making image processing an often labor-intensive task that is difficult to reliably automate. We previously reported a novel third-dye array visualization (TDAV) technology that allows prehybridization visualization and quality control of printed arrays. Here, we present a new microarray image processing approach utilizing TDAV. By incorporating the third-dye image, we show that overall quality of the microarray data is significantly improved, and automation of processing is feasible and reliable. Furthermore, we demonstrate use of the third-dye image to better quality control microarray image analysis. Both the principle and implementation of the approach are presented in detail, with experimental results.


  • Open Access

    Quantitative quality control in microarray experiments and the application in data filtering, normalization and false positive rate prediction

    by Xujing Wang, Martin J. Hessner, Yan Wu, Nirupma Pati, Soumitra Ghosh

    Data preprocessing including proper normalization and adequate quality control before complex data mining is crucial for studies using the cDNA microarray technology. We have developed a simple procedure that integrates data filtering and normalization with quantitative quality control of microarray experiments. Previously we have shown that data variability in a microarray experiment can be very well captured by a quality score qcom that is defined for every spot, and the ratio distribution depends on qcom. Utilizing this knowledge, our data-filtering scheme allows the investigator to decide on the filtering stringency according to desired data variability, and our normalization procedure corrects the qcom-dependent dye biases in terms of both the location and the spread of the ratio distribution. In addition, we propose a statistical model for false positive rate determination based on the design and the quality of a microarray experiment. The model predicts that a lower limit of 0.5 for the replicate concordance rate is needed in order to be certain of true positives. Our work demonstrates the importance and advantages of having a quantitative quality control scheme for microarrays. Contact: xujing@mcw.edu


  • Open Access

    Quantitative quality control in microarray image processing and data acquisition

    by Xujing Wang, Soumitra Ghosh, Sun-Wei Guo

    A new integrated image analysis package with quantitative quality control schemes is described for cDNA microarray technology. The package employs an iterative algorithm that utilizes both intensity characteristics and spatial information of the spots on a microarray image for signal–background segmentation and defines five quality scores for each spot to record irregularities in spot intensity, size and background noise levels. A composite score qcom is defined based on these individual scores to give an overall assessment of spot quality. Using qcom we demonstrate that the inherent variability in intensity ratio measurements is closely correlated with spot quality, namely spots with higher quality give less variable measurements and vice versa. In addition, gauging data by qcom can improve data reliability dramatically and efficiently. We further show that the variability in ratio measurements drops exponentially with increasing qcom and, for the majority of spots at the high quality end, this improvement is mainly due to an improvement in correlation between the two dyes. Based on these studies, we discuss the potential of quantitative quality control for microarray data and the possibility of filtering and normalizing microarray data using a quality metrics-dependent scheme.