Viktor Gruev
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Viktor Gruev has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Timothy York
Department of Electrical and Computer Engineering, Campus Box 1801, Southern Illinois University Edwardsville, Edwardsville, IL 62026, USA
2 shared publications- Baranidharan Raman
Department of Biomedical Engineering, Washington University, St. Louis, MO, USA
1 shared publication Christopher Edmiston
Washington University in St. Louis, Department of Computer Science & Engineering, St. Louis, MO, 63130, USA
1 shared publication- Debajit Saha
Department of Biomedical Engineering, Washington University, St. Louis, MO, USA
1 shared publication Ignacio de Erausquin
Washington University in St. Louis, Department of Computer Science & Engineering, St. Louis, MO, 63130, USA
1 shared publicationJan Van der Spiegel
Electrical and Systems Engineering Department, University of Pennsylvania, 200 S. 33rd St., Philadelphia 19104, Pennsylvania, USA
1 shared publication
Latest Publications
- Open Access
- 8 April 2016
- Published by Optica Publishing Group in Optics Express
- Vol. 24 (8) , 8243-8252
260 frames-per-second 648x488 resolution division-of-focal-plane polarimeter with structural dynamics and tracking applications
We have designed an image sensor that can capture the first three Stokes parameters at 648 by 488 spatial resolution at 260 frames per second. The sensor consists of a CCD image sensor monolithically integrated with pixel pitch-matched aluminum nanowire polarization filters. The sensor demonstrates a Malus law response over all pixels, and has a relatively uniform diattenuation over the visible spectrum. We demonstrate two potential applications for the sensor. The first uses circular polarization in transmission mode to observe high-speed stress failure in polycarbonate. The second uses polarization in reflected mode to track high speed automobile traffic.
- 8 April 2016
- Published by Optica Publishing Group in Optics Express
- Vol. 24 (8) , 8243-8252
Open Access260 frames-per-second 648x488 resolution division-of-focal-plane polarimeter with structural dynamics and tracking applications
We have designed an image sensor that can capture the first three Stokes parameters at 648 by 488 spatial resolution at 260 frames per second. The sensor consists of a CCD image sensor monolithically integrated with pixel pitch-matched aluminum nanowire polarization filters. The sensor demonstrates a Malus law response over all pixels, and has a relatively uniform diattenuation over the visible spectrum. We demonstrate two potential applications for the sensor. The first uses circular polarization in transmission mode to observe high-speed stress failure in polycarbonate. The second uses polarization in reflected mode to track high speed automobile traffic.
- Open Access
- 22 May 2015
- Published by Optica Publishing Group in Optics Express
- Vol. 23 (11) , 14391-14406
Surface normal reconstruction using circularly polarized light
The polarization properties of reflected light capture important information about the object’s inherent properties: material composition, i.e. index of refraction and scattering properties, and shape of the object, i.e. surface normal. Polarization information therefore has been used for surface reconstruction using a single-view camera with unpolarized incident light. However, this surface normal reconstruction technique suffers from a zenith angle ambiguity. In this paper, we have utilized circularly polarized light to solve for the zenith ambiguity by developing a detailed model using Mueller matrix formulism and division of focal plane polarization imaging technology. Experiment results validate our model for accurate surface reconstruction.
- 22 May 2015
- Published by Optica Publishing Group in Optics Express
- Vol. 23 (11) , 14391-14406
Open AccessSurface normal reconstruction using circularly polarized light
The polarization properties of reflected light capture important information about the object’s inherent properties: material composition, i.e. index of refraction and scattering properties, and shape of the object, i.e. surface normal. Polarization information therefore has been used for surface reconstruction using a single-view camera with unpolarized incident light. However, this surface normal reconstruction technique suffers from a zenith angle ambiguity. In this paper, we have utilized circularly polarized light to solve for the zenith ambiguity by developing a detailed model using Mueller matrix formulism and division of focal plane polarization imaging technology. Experiment results validate our model for accurate surface reconstruction.
- Open Access
- 20 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Proceedings of the IEEE
- Vol. 102 (10) , 1450-1469
Bioinspired Polarization Imaging Sensors: From Circuits and Optics to Signal Processing Algorithms and Biomedical Applications
In this paper, we present recent work on bioinspired polarization imaging sensors and their applications in biomedicine. In particular, we focus on three different aspects of these sensors. First, we describe the electro-optical challenges in realizing a bioinspired polarization imager, and in particular, we provide a detailed description of a recent low-power complementary metal-oxide-semiconductor (CMOS) polarization imager. Second, we focus on signal processing algorithms tailored for this new class of bioinspired polarization imaging sensors, such as calibration and interpolation. Third, the emergence of these sensors has enabled rapid progress in characterizing polarization signals and environmental parameters in nature, as well as several biomedical areas, such as label-free optical neural recording, dynamic tissue strength analysis, and early diagnosis of flat cancerous lesions in a murine colorectal tumor model. We highlight results obtained from these three areas and discuss future applications for these sensors.
- 20 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Proceedings of the IEEE
- Vol. 102 (10) , 1450-1469
Open AccessBioinspired Polarization Imaging Sensors: From Circuits and Optics to Signal Processing Algorithms and Biomedical Applications
In this paper, we present recent work on bioinspired polarization imaging sensors and their applications in biomedicine. In particular, we focus on three different aspects of these sensors. First, we describe the electro-optical challenges in realizing a bioinspired polarization imager, and in particular, we provide a detailed description of a recent low-power complementary metal-oxide-semiconductor (CMOS) polarization imager. Second, we focus on signal processing algorithms tailored for this new class of bioinspired polarization imaging sensors, such as calibration and interpolation. Third, the emergence of these sensors has enabled rapid progress in characterizing polarization signals and environmental parameters in nature, as well as several biomedical areas, such as label-free optical neural recording, dynamic tissue strength analysis, and early diagnosis of flat cancerous lesions in a murine colorectal tumor model. We highlight results obtained from these three areas and discuss future applications for these sensors.
- 30 August 2013
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (18) , 21039-21055
Calibration methods for division-of-focal-plane polarimeters
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 30 August 2013
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (18) , 21039-21055
Calibration methods for division-of-focal-plane polarimeters
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 10 January 2013
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (1) , 1137-1151
Gradient-based interpolation method for division-of-focal-plane polarimeters
Recent advancements in nanotechnology and nanofabrication have allowed for the emergence of the division-of-focal-plane (DoFP) polarization imaging sensors. These sensors capture polarization properties of the optical field at every imaging frame. However, the DoFP polarization imaging sensors suffer from large registration error as well as reduced spatial-resolution output. These drawbacks can be improved by applying proper image interpolation methods for the reconstruction of the polarization results. In this paper, we present a new gradient-based interpolation method for DoFP polarimeters. The performance of the proposed interpolation method is evaluated against several previously published interpolation methods by using visual examples and root mean square error (RMSE) comparison. We found that the proposed gradient-based interpolation method can achieve better visual results while maintaining a lower RMSE than other interpolation methods under various dynamic ranges of a scene ranging from dim to bright conditions.
- 10 January 2013
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (1) , 1137-1151
Gradient-based interpolation method for division-of-focal-plane polarimeters
Recent advancements in nanotechnology and nanofabrication have allowed for the emergence of the division-of-focal-plane (DoFP) polarization imaging sensors. These sensors capture polarization properties of the optical field at every imaging frame. However, the DoFP polarization imaging sensors suffer from large registration error as well as reduced spatial-resolution output. These drawbacks can be improved by applying proper image interpolation methods for the reconstruction of the polarization results. In this paper, we present a new gradient-based interpolation method for DoFP polarimeters. The performance of the proposed interpolation method is evaluated against several previously published interpolation methods by using visual examples and root mean square error (RMSE) comparison. We found that the proposed gradient-based interpolation method can achieve better visual results while maintaining a lower RMSE than other interpolation methods under various dynamic ranges of a scene ranging from dim to bright conditions.
- 25 July 2012
- Published by Optica Publishing Group in Applied Optics
- Vol. 51 (22) , 5392-5400
Characterization of a visible spectrum division-of-focal-plane polarimeter
The development of high resolution division-of-focal-plane polarimeters in the visible spectrum allows real-time capture of two chief properties of interest, the degree of linear polarization and the angle of polarization. The accuracy of these two parameters can be influenced by a number of factors in the imaged scene, from the incident intensity and wavelength to the lens used for image capture. The alignment, transmission, and contrast ratios of the pixel matched filters also impact the measured parameters. A system of measurements is presented here that shows how these factors can determine the quality of a division-of-focal-plane polarimeter.
- 25 July 2012
- Published by Optica Publishing Group in Applied Optics
- Vol. 51 (22) , 5392-5400
Characterization of a visible spectrum division-of-focal-plane polarimeter
The development of high resolution division-of-focal-plane polarimeters in the visible spectrum allows real-time capture of two chief properties of interest, the degree of linear polarization and the angle of polarization. The accuracy of these two parameters can be influenced by a number of factors in the imaged scene, from the incident intensity and wavelength to the lens used for image capture. The alignment, transmission, and contrast ratios of the pixel matched filters also impact the measured parameters. A system of measurements is presented here that shows how these factors can determine the quality of a division-of-focal-plane polarimeter.
- 14 November 2011
- Published by Optica Publishing Group in Optics Express
- Vol. 19 (24) , 24361-24369
Fabrication of a dual-layer aluminum nanowires polarization filter array
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 14 November 2011
- Published by Optica Publishing Group in Optics Express
- Vol. 19 (24) , 24361-24369
Fabrication of a dual-layer aluminum nanowires polarization filter array
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 24 November 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (25) , 25815-25824
Signal-to-noise analysis of Stokes parameters in division of focal plane polarimeters
An analysis of the temporal noise in the Stokes parameters computed by division of focal plane polarimeters is presented. Theoretical estimations of the Stokes parameter signal-to-noise ratios for CCD polarization imaging sensors with both 4-polarizer and 2-polarizer micropolarization filter arrays are derived. The theoretical derivation is verified with measurements from an integrated polarization imaging sensor composed of a CCD imaging array and aluminum nanowire polarization filters. The measured data obtained from the CCD polarimeters matches the theoretical derivations of the temporal noise model of the Stokes parameters.
- 24 November 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (25) , 25815-25824
Signal-to-noise analysis of Stokes parameters in division of focal plane polarimeters
An analysis of the temporal noise in the Stokes parameters computed by division of focal plane polarimeters is presented. Theoretical estimations of the Stokes parameter signal-to-noise ratios for CCD polarization imaging sensors with both 4-polarizer and 2-polarizer micropolarization filter arrays are derived. The theoretical derivation is verified with measurements from an integrated polarization imaging sensor composed of a CCD imaging array and aluminum nanowire polarization filters. The measured data obtained from the CCD polarimeters matches the theoretical derivations of the temporal noise model of the Stokes parameters.
- 26 August 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (18) , 19292-19303
Dual-tier thin film polymer polarization imaging sensor
Traditional imaging systems capture and replicate the imaged environment in terms of color and intensity. One important property of light, which the human eye is blind to and is ignored by traditional imaging systems, is polarization. In this paper we present a novel, low power imaging sensor capable of recording the optical properties of partially linearly polarized light in real-time. The imaging sensor combines polymer polarization filters with a CMOS image sensor in order to compute the first three Stokes parameters at the focal plane. The imaging array contains 100 x 100 pixels and consumes 48mW at 30 fps.
- 26 August 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (18) , 19292-19303
Dual-tier thin film polymer polarization imaging sensor
Traditional imaging systems capture and replicate the imaged environment in terms of color and intensity. One important property of light, which the human eye is blind to and is ignored by traditional imaging systems, is polarization. In this paper we present a novel, low power imaging sensor capable of recording the optical properties of partially linearly polarized light in real-time. The imaging sensor combines polymer polarization filters with a CMOS image sensor in order to compute the first three Stokes parameters at the focal plane. The imaging array contains 100 x 100 pixels and consumes 48mW at 30 fps.
- Top Cited Papers
- 24 August 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (18) , 19087-19094
CCD polarization imaging sensor with aluminum nanowire optical filters
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 24 August 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (18) , 19087-19094
Top Cited PapersCCD polarization imaging sensor with aluminum nanowire optical filters
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.