Jacques Duparré
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jacques Duparré has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Andreas Bräuer
The authors are with the Fraunhofer-Institut für Angewandte Optik und Feinmechanik, Albert Einstein Strasse 7, D-07745 Jena, Germany
1 shared publicationAndreas Tünnermann
The authors are with the Fraunhofer-Institut für Angewandte Optik und Feinmechanik, Albert Einstein Strasse 7, D-07745 Jena, Germany
1 shared publicationPeter Dannberg
The authors are with the Fraunhofer-Institut für Angewandte Optik und Feinmechanik, Albert Einstein Strasse 7, D-07745 Jena, Germany
1 shared publicationPeter Schreiber
The authors are with the Fraunhofer-Institut für Angewandte Optik und Feinmechanik, Albert Einstein Strasse 7, D-07745 Jena, Germany
1 shared publication
Latest Publications
- 20 May 2005
- Published by Optica Publishing Group in Applied Optics
- Vol. 44 (15) , 2949-2956
Thin compound-eye camera
An artificial compound-eye objective fabricated by micro-optics technology is adapted and attached to a CMOS sensor array. The novel optical sensor system with an optics thickness of only 0.2 mm is examined with respect to resolution and sensitivity. An optical resolution of 60 × 60 pixels is determined from captured images. The scaling behavior of artificial compound-eye imaging systems is analyzed. Cross talk between channels fabricated by different technologies is evaluated, and the influence on an extension of the field of view by addition of a (Fresnel) diverging lens is discussed. The lithographic generation of opaque walls between channels for optical isolation is experimentally demonstrated.
- 20 May 2005
- Published by Optica Publishing Group in Applied Optics
- Vol. 44 (15) , 2949-2956
Thin compound-eye camera
An artificial compound-eye objective fabricated by micro-optics technology is adapted and attached to a CMOS sensor array. The novel optical sensor system with an optics thickness of only 0.2 mm is examined with respect to resolution and sensitivity. An optical resolution of 60 × 60 pixels is determined from captured images. The scaling behavior of artificial compound-eye imaging systems is analyzed. Cross talk between channels fabricated by different technologies is evaluated, and the influence on an extension of the field of view by addition of a (Fresnel) diverging lens is discussed. The lithographic generation of opaque walls between channels for optical isolation is experimentally demonstrated.