MHMasayuki Hirokawa

Masayuki Hirokawa

*This is an algorithmically generated author record based on publicly available information.

Masayuki Hirokawa has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Supplement of Clinical Practice Guidelines for Endovenous Thermal Ablation for Varicose Veins 2019: Laser Ablation of Varicose Tributaries

    by Masayuki Hirokawa, Junichi Utoh, Satoru Sugiyama, Osamu Suzuki, Takashi Yamamoto, Tomohiro Ogawa, Makoto Mo

    In the treatment of saphenous varicose veins with endovenous laser ablation, simultaneous treatment of varicose tributaries using stab avulsion or sclerotherapy is commonly performed. To address the limitations of these conventional treatments, laser ablation for varicose tributaries has recently gained widespread acceptance. This guideline, developed by the Japanese Society of Phlebology, outlines appropriate treatment protocols for laser ablation of varicose tributaries. Indications include primary varicose veins requiring concurrent treatment of the saphenous trunk and varicose tributaries. The procedure utilizes slim radial fibers, with puncture and ablation performed using either short- or long-axis approaches. Although rare, adverse events such as skin burns, nerve injury, and fiber breakage have been reported. A learning curve is necessary to ensure the safe execution of the procedure. Further clinical studies are essential to enhance the safety and efficacy of laser ablation for varicose tributaries. (This is a secondary publication from Jpn J Phlebol 2025; 36: 51–58.)


  • Open Access

    Serious Adverse Events with Cyanoacrylate Closure of Varicose Veins: An Initial Report from a Large-Scale National Survey in Japan

    by Michihisa Umetsu, Masayuki Hirokawa, Eri Fukaya, Eiichi Teshima, Hitoshi Kusagawa, Toshiya Nishibe, Hiroko Nemoto, Makoto Mo, Tomohiro Ogawa

    Objective: Cyanoacrylate closure (CAC) is a minimally invasive technique for the treatment of varicose veins. A recent paper reported serious adverse events (AEs) associated with this use. This triggered an urgent survey to determine the incidence of AEs in Japan.Methods: The CAC-AE survey was sent to all 1,030 institutions authorized for CAC treatments. Cases performed between January 2020 and October 2023 were surveyed. Data on serious AEs and mortality were collected.Results: There were 623 surveys returned. There were 16 cases of proximal deep vein thrombosis, 3 cases of pulmonary embolism (PE), and 0 cases of stroke. Deep vein occlusion due to cyanoacrylate extension was observed in 1 case. Vein resection due to infection was observed in 4 cases. There were 299 cases of localized phlebitis and/or allergic reactions requiring steroid administration. Systemic allergic reactions requiring steroid administration were observed in 66 cases. There was no anaphylaxis associated with cyanoacrylate. There was one postoperative death from PE.Conclusion: This report’s intent is to provide real world data on serious AEs following CAC from Japan given current concern over these events. An extensive report investigation of individual complications with analysis including causality will be provided following a full investigation separately.


  • Open Access

    Comparison of 1470 nm Laser and Radial 2ring Fiber with 980 nm Laser and Bare-Tip Fiber in Endovenous Laser Ablation of Saphenous Varicose Veins: A Multicenter, Prospective, Randomized, Non-Blind Study

    by Masayuki Hirokawa, Tomohiro Ogawa, Hiromitsu Sugawara, Shintaro Shokoku, Shoji Sato

    The aim of this study is to compare the clinical efficacy and safety of two laser wavelengths and fiber types in endovenous laser ablation (EVLA) of saphenous varicose veins of the lower limb. Multi-center prospective randomized non-blind clinical trial. From January 2007 to December 2011, 113 patients (113 limbs) with primary varicose veins were randomized into two groups. They were treated with radial 2ring fiber and 1470 nm laser in Group I (57 limbs) and bare-tip fiber and 980 nm laser in Group E (56 limbs) in order to ablate the saphenous vein. Vein occlusion rates at 12 weeks and pain in treated region were recorded as primary endpoint. Visual analogue scale (VAS) for assessment of pain, rates of bruising, complications and equipment failure were recorded as secondary endpoint of safety. Occlusion rates at 12 weeks were 100% in both groups. Rates of pain (0% vs. 25.0%) and bruising (7.0% vs. 57.1%) were significantly lower in Group I (p <0.0001). VAS of pain was significantly lower on postoperative day 1, day 5 and 2nd week in Group I. Treatment of saphenous varicose veins by EVLA using a 1470 nm laser and a radial 2ring fiber resulted in comparable occlusion rates at 12 weeks and less postoperative pain and bruising than EVLA with a 980 nm laser and a bare-tip fiber. (This article is a translation of Jpn J Vasc Surg 2014; 23: 964-971.).


  • Comparison of Bare-Tip and Radial Fiber in Endovenous Laser Ablation with 1470 nm Diode Laser

    by Masayuki Hirokawa, Nobuhisa Kurihara

    Major side effects after endovenous laser ablation (EVLA) are pain and bruising. The aim of this study was to compare outcome and side effects after EVLA for primary varicose veins with 1470 nm diode laser using bare-tip orradial fiber. From October 2007 to December 2010, 385 patients (453 limbs) with primary varicose veins treated with 1470 nm laser were studied. Bare-tip fiber was used in 215 patients (242 limbs) (BF group) and radial fiber (ELVeS(TM)Radial, Biolitec AG, Germany) was used in 177 patients (211 limbs) (RF group). This study is a retrospective study and radial fiber was started for use from November 2008. Laser energy was administered at 6-12 W of power in the BF group and 10 W of power in the RF group with constant pullback of laser fiber under tumescent local anesthesia. The patients were assessed by clinical examination and venous duplex ultrasonography at 24-48 h, one week, one month, 4 months and one year follow-up postoperatively. Mean operating time, length of treated vein and linear endovenous laser energy of all cases were 42.6 min, 36.2 cm and 83.4 J/cm, respectively. Major complications such as deep vein thrombosis and skin burns were not noted. Bruising (1.9% vs. 19.4%) and pain (0.9% vs. 7.4%) were significantly lower in the RF group. Cumulative occlusion rates by Kaplan-Meier method were 100% at 32 months in the RF group and 99.5% at 4 years in the BF group. EVLA using 1470 nm laser with the radial fiber minimized adverse effects compared with bare-tip laser fiber. (English translation of Jpn J Vasc Surg 2013; 22: 615-621).


  • A soft dual-port trocar for endoscopic subcutaneous surgery

    by M. Hirokawa, K. Oda, A. Yamamoto, S. Sasaguri

    We developed a new trocar for endoscopic subcutaneous surgery and tested it in subfascial endoscopic perforator surgery (SEPS) for varicose veins of the lower leg. The soft trocar is a Y-shaped polyvinyl chloride bag equipped with two ports at one end and a flexible ring at the other end. We performed SEPS on 12 patients through a 2-cm incision below the knee. After dissection of the subfascial plane, the ring of the trocar was inserted beneath the fascia, and the subfascial cavity was inflated with CO2 gas. The perforating veins were divided with UltraShears (Autosuture, USSC, Norwalk, CT, USA) inserted through the second port of the trocar with an endoscope. There were no major device-related difficulties or wound complications. The soft trocar allowed both an endoscope and a surgical instrument to be inserted simultaneously in the tissue space through a single incision. This useful instrument may have applications in other endoscopic surgical procedures.


  • Endoscopic Vein Surgery in Lower Extremities with VasoView System

    by Masayuki Hirokawa, Katsushi Oda, Akira Yamamoto, Hideaki Nishimori, Atsushi Hata, Takashi Fukutomi, Kunihiko Hirose, Shiro Sasaguri

    The VasoView system was used for endoscopic saphenous vein harvesting in 10 coronary artery bypass patients and for endoscopic subfascial division of perforating veins in 8 patients with varicose veins. In both procedures, the surface of the saphenous vein and the subfascial plane were dissected using the VasoView dissection cannula. An operative tunnel was subsequently created by inflating and deflating the balloon and maintained by carbon dioxide insufflation. The branches of the saphenous vein and the perforating veins were divided with bipolar scissors under endoscopic vision. In endoscopic saphenous vein harvesting, the mean graft length was 31.5 ± 7.5 cm and the mean number of skin incisions was 3 ± 1.2. In endoscopic subfascial division of perforating veins, 3.4 ± 1.7 veins were divided. The VasoView system is attributed with a decrease in complications after vein surgery in the lower extremities.