CCChareenun Chirapapaisan

Chareenun Chirapapaisan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chareenun Chirapapaisan has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Accuracy of Holladay 2 formula using IOLMaster parameters in the absence of lens thickness value

    by Sabong Srivannaboon, Chareenun Chirapapaisan, Niphon Chirapapaisan, Buntitar Lertsuwanroj, Mathinee Chongchareon

    The accuracy of the Holladay 2 (H2) formula is well-documented. This formula requires seven variables to estimate effective lens position (ELP) for the IOL power calculation. The lens thickness (LT) value is one of the required variables. Interestingly, the IOLMaster, which is one of the most commonly used optical biometers, can provide all the required ocular variables except LT value. It has become a pertinent issue to evaluate the accuracy of theH2 formula when it is used without the LT value. The purpose of this study was to evaluate the results when using the H2 formula, without the LT value, and compare such results to those obtained using the Haigis formula and the Hoffer Q formula. The Institutional review board (IRB) gave their approval for the conduct of this prospective comparative study. One hundred and sixty-three eyes of 143 cataract patients from the Ophthalmology Department, Siriraj Hospital, Thailand were recruited. All eyes were measured using the IOLMaster (Carl Zeiss Meditec, Jena, Germany) for keratometry (K), axial length (AL), anterior chamber depth (ACD), and horizontal white-to-white (WTW) corneal diameter. Then, the LT measurement was obtained by A-scan ultrasonography (Quantel Axis-II, Quantel Medical, USA). Every patient underwent uncomplicated phacoemulsification by a single surgeon (NC) with a single technique using a single IOL model. Post-operative refraction was obtained at 3 months. The mean absolute errors (MAEs), median absolute errors (MedAEs) and percentage of the eyes within ±0.25, ±0.50, and ±1.00 D of predicted refraction was calculated for H2 formula both with and without LT input, Haigis, and Hoffer Q formula. The results were also classified into a group of short AL (24.5 mm). There was no statistically significant difference in either MAEs or MedAEs of all formulas in all AL groups including the H2 with and without LT. There was a trend toward lower MAEs and MedAEs for H2 in the long AL group. Percentage of the eyes within ±0.25, ±0.50, and ±1.00 D of predicted refraction were similar in all AL groups. The preliminary results of this study showed that the H2 formula performed well even without the LT value. It was comparable to the Haigis and Hoffer Q formulas.


  • Agreement of IOL power and axial length obtained by IOLMaster 500 vs IOLMaster 500 with Sonolink connection

    by Sabong Srivannaboon, Chareenun Chirapapaisan, Patchara Nantasri, Mathinee Chongchareon, Pratuangsri Chonpimai

    The accurrate and expedient ocular biometry is essential for modern cataract surgery. IOLMaster 500, one of the most popular partial coherence interferometry (PCI) device, has been widely used. However, with the PCI device, it is difficult to obtain the axial length through densely opaque media. With the current version of IOLMaster 500, a unique feature is added to link with the Synergy immersion A-scan ultrasound (sonolink connection). In case of failure to measure axial length by IOLMaster 500, the axial length can be obtained by ultrasound, and then transferred to IOLMaster 500 for the IOL power calculation. This study aims to compare the results and evaluate the agreement between IOL power and axial length obtained by IOLMaster 500 and IOLMaster 500 with sonolink connection. A prospective study of 60 eyes in 60 mild-to-moderate cataract patients was conducted under Institutional Ethics Committee approval. Keratometry (K) and axial length (AL) of all eyes were measured using IOLMaster 500 (Carl Zeiss, Germany), then IOL power was generated using Holladay 1 formula (group 1). After 5 min, the K measurements were repeated with IOLMaster 500 and the AL were measured again using the Synergy A-scan ultrasound (Accutome, USA). Then, the AL data were transferred to IOLMaster 500 via the sonolink connection to generate the IOL power using the same setting (group 2). The IOL power and AL were compared between the two groups, and the agreement was evaluated using intraclass correlation coefficient (ICC) and the Bland–Altman method. The mean IOL power in group 1 was 21.04 + 2.36 D and group 2 was 21.03 + 2.36 D. The mean AL in group 1 was 23.35 + 0.86 mm and in group 2 was 23.36 + 0.86 mm. There was no statistically significant difference in IOL power and AL between the two groups. The agreements in IOL power and AL between both groups were high (ICCs = 0.997 for IOL power and 0.993 for AL) The IOL power and AL derived from both groups were similar. The agreements between them were high.