Anat Cohen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Anat Cohen has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
A. Capozzoli
Dipartimento di Ingegneria Elettrica e delle Tecnologie dell'Informazione (DIETI), Università di Napoli Federico II 1 , 80125 Napoli, Italy
1 shared publicationA. Liseno
Dipartimento di Ingegneria Elettrica e delle Tecnologie dell'Informazione (DIETI), Università di Napoli Federico II 1 , 80125 Napoli, Italy
1 shared publication- Claudio Curcio
Università di Napoli Federico II
1 shared publication Francesca Borrelli
Institute of Applied Sciences and Intelligent Systems “E. Caianiello” CNR-ISASI Via Campi Flegrei 34 80078 Pozzuoli Napoli Italy
1 shared publication- Francesca Borrelli
Institute of Applied Sciences and Intelligent Systems "Eduardo Caianiello" CNR-ISASI Via Campi Flegrei 34 80078 Pozzuoli (Napoli Italy
1 shared publication I. Kurelac
Unit of Medical Genetics, Department of Medical and Surgical Sciences (DIMEC), University of Bologna 5 , Via Massarenti 9, Bologna 40138, Italy
1 shared publication
Latest Publications
- Open Access
- 3 November 2023
- Published by Wiley in Advanced Intelligent Systems
- Vol. 6 (1)
Label‐Free Imaging Flow Cytometry for Cell Classification Based on Multiple Interferometric Projections Using Deep Learning
A new label‐free imaging flow cytometry method for noninvasive and automated biological cell classification is presented. Each cell is rolled during flow, and its off‐axis holograms from multiple viewpoints are acquired. Using the reconstructed quantitative phase profiles of the cell projections, highly discriminating features, enabling cell detection, classification, and differentiation, are extracted via a modified ResNet‐18 deep convolutional neural network architecture. The model is first validated by classifying metastatic breast carcinoma cells (MCF‐7) and normal human mammary epithelial cells (MCF‐10A). An increase in classification accuracy by 1% is achieved when processing five interferometric projections versus processing a single interferometric projection. This model is further tested on four types of white blood cells and exhibits an accuracy increase of 5% when processing 12 interferometric projections versus processing a single interferometric projection. This approach is shown to be superior to that of using conventional 2D‐rotation augmentation, and can be used to decrease substantially the number of cell examples needed for training the classification model without impairing the results. This novel concept has great potential to be incorporated into label‐free imaging flow cytometry and improve cell classification, and be used to detect various types of medical conditions and diseases.
- 3 November 2023
- Published by Wiley in Advanced Intelligent Systems
- Vol. 6 (1)
Open AccessLabel‐Free Imaging Flow Cytometry for Cell Classification Based on Multiple Interferometric Projections Using Deep Learning
A new label‐free imaging flow cytometry method for noninvasive and automated biological cell classification is presented. Each cell is rolled during flow, and its off‐axis holograms from multiple viewpoints are acquired. Using the reconstructed quantitative phase profiles of the cell projections, highly discriminating features, enabling cell detection, classification, and differentiation, are extracted via a modified ResNet‐18 deep convolutional neural network architecture. The model is first validated by classifying metastatic breast carcinoma cells (MCF‐7) and normal human mammary epithelial cells (MCF‐10A). An increase in classification accuracy by 1% is achieved when processing five interferometric projections versus processing a single interferometric projection. This model is further tested on four types of white blood cells and exhibits an accuracy increase of 5% when processing 12 interferometric projections versus processing a single interferometric projection. This approach is shown to be superior to that of using conventional 2D‐rotation augmentation, and can be used to decrease substantially the number of cell examples needed for training the classification model without impairing the results. This novel concept has great potential to be incorporated into label‐free imaging flow cytometry and improve cell classification, and be used to detect various types of medical conditions and diseases.
- Open Access
- 1 June 2023
- Published by AIP Publishing in APL Bioengineering
- Vol. 7 (2) , 026110
AI-aided holographic flow cytometry for label-free identification of ovarian cancer cells in the presence of unbalanced datasets
Liquid biopsy is a valuable emerging alternative to tissue biopsy with great potential in the noninvasive early diagnostics of cancer. Liquid biopsy based on single cell analysis can be a powerful approach to identify circulating tumor cells (CTCs) in the bloodstream and could provide new opportunities to be implemented in routine screening programs. Since CTCs are very rare, the accurate classification based on high-throughput and highly informative microscopy methods should minimize the false negative rates. Here, we show that holographic flow cytometry is a valuable instrument to obtain quantitative phase-contrast maps as input data for artificial intelligence (AI)-based classifiers. We tackle the problem of discriminating between A2780 ovarian cancer cells and THP1 monocyte cells based on the phase-contrast images obtained in flow cytometry mode. We compare conventional machine learning analysis and deep learning architectures in the non-ideal case of having a dataset with unbalanced populations for the AI training step. The results show the capacity of AI-aided holographic flow cytometry to discriminate between the two cell lines and highlight the important role played by the phase-contrast signature of the cells to guarantee accurate classification.
- 1 June 2023
- Published by AIP Publishing in APL Bioengineering
- Vol. 7 (2) , 026110
Open AccessAI-aided holographic flow cytometry for label-free identification of ovarian cancer cells in the presence of unbalanced datasets
Liquid biopsy is a valuable emerging alternative to tissue biopsy with great potential in the noninvasive early diagnostics of cancer. Liquid biopsy based on single cell analysis can be a powerful approach to identify circulating tumor cells (CTCs) in the bloodstream and could provide new opportunities to be implemented in routine screening programs. Since CTCs are very rare, the accurate classification based on high-throughput and highly informative microscopy methods should minimize the false negative rates. Here, we show that holographic flow cytometry is a valuable instrument to obtain quantitative phase-contrast maps as input data for artificial intelligence (AI)-based classifiers. We tackle the problem of discriminating between A2780 ovarian cancer cells and THP1 monocyte cells based on the phase-contrast images obtained in flow cytometry mode. We compare conventional machine learning analysis and deep learning architectures in the non-ideal case of having a dataset with unbalanced populations for the AI training step. The results show the capacity of AI-aided holographic flow cytometry to discriminate between the two cell lines and highlight the important role played by the phase-contrast signature of the cells to guarantee accurate classification.