Bin-Bin Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bin-Bin Zhang has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Yan Chen
University of Science and Technology of China
8 shared publications - Yang Hu
University of Science and Technology of China
7 shared publications - Dongheng Zhang
University of Science and Technology of China
5 shared publications - Jinbo Chen
School of Cyber Science and Technology, University of Science and Technology of China, Hefei, China
3 shared publications - Binquan Wang
School of Cyber Science and Technology, University of Science and Technology of China, Hefei, China
2 shared publications - Jianyang Wang
School of Cyber Science and Technology, University of Science and Technology of China, Hefei, China
2 shared publications
Latest Publications
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 13 (13) , 28743-28757
Contactless Premature Ventricular Contractions Diagnosis With Radio Frequency Signals Based on Deep Auxiliary Learning
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 13 (13) , 28743-28757
Contactless Premature Ventricular Contractions Diagnosis With Radio Frequency Signals Based on Deep Auxiliary Learning
- 24 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Mobile Computing
- Vol. 25 (8) , 11885-11899
Automatic Phase Calibration for High-Resolution mmWave Sensing via Ambient Radio Anchors
Millimeter-wave (mmWave) radar systems with large array have pushed radar sensing into a new era, thanks to their high angular resolution. However, our long-term experiments indicate that array elements exhibit phase drift over time and require periodic phase calibration to maintain high-resolution, creating an obstacle for practical high-resolution mmWave sensing with large array. Unfortunately, existing calibration methods are inadequate for periodic recalibration, either because they rely on artificial references or fail to provide sufficient precision. To address this challenge, we introduce AutoCalib, the first framework designed to automatically and accurately calibrate high-resolution mmWave radars by identifying Ambient Radio Anchors (ARAs)—naturally existing objects in ambient environments that offer stable phase references. AutoCalib achieves calibration by first generating spatial spectrum templates based on theoretical electromagnetic characteristics. It then employs a pattern-matching and scoring mechanism to accurately detect these anchors and select the optimal one for calibration. Extensive experiments across 11 environments demonstrate that AutoCalib is capable of identifying ARAs that existing methods miss due to their focus on strong reflectors. AutoCalib's calibration performance approaches corner reflectors (74% phase error reduction) while outperforming existing methods by 83%. Beyond radar calibration, AutoCalib effectively supports other phase-dependent applications like handheld imaging, delivering 96% of corner reflector calibration performance without artificial references.
- 24 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Mobile Computing
- Vol. 25 (8) , 11885-11899
Automatic Phase Calibration for High-Resolution mmWave Sensing via Ambient Radio Anchors
Millimeter-wave (mmWave) radar systems with large array have pushed radar sensing into a new era, thanks to their high angular resolution. However, our long-term experiments indicate that array elements exhibit phase drift over time and require periodic phase calibration to maintain high-resolution, creating an obstacle for practical high-resolution mmWave sensing with large array. Unfortunately, existing calibration methods are inadequate for periodic recalibration, either because they rely on artificial references or fail to provide sufficient precision. To address this challenge, we introduce AutoCalib, the first framework designed to automatically and accurately calibrate high-resolution mmWave radars by identifying Ambient Radio Anchors (ARAs)—naturally existing objects in ambient environments that offer stable phase references. AutoCalib achieves calibration by first generating spatial spectrum templates based on theoretical electromagnetic characteristics. It then employs a pattern-matching and scoring mechanism to accurately detect these anchors and select the optimal one for calibration. Extensive experiments across 11 environments demonstrate that AutoCalib is capable of identifying ARAs that existing methods miss due to their focus on strong reflectors. AutoCalib's calibration performance approaches corner reflectors (74% phase error reduction) while outperforming existing methods by 83%. Beyond radar calibration, AutoCalib effectively supports other phase-dependent applications like handheld imaging, delivering 96% of corner reflector calibration performance without artificial references.
- 9 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Mobile Computing
- Vol. 25 (5) , 7373-7390
MaskSense: Motion-Robust Dynamic IBI Estimation via Deep RF Masked Learning
Although radio frequency (RF) sensing offers a promising approach for monitoring human cardiac activity, it traditionally requires subjects to remain in a steady-state throughout the monitoring process to avoid motion artifacts—an inherently impractical constraint that hampers real-world adoption. However, existing methods either yield incorrect estimates from motion-affected segments or discard them entirely, leading to fragmented data and incomplete observations. To address the challenge, we introduce MaskSense, a novel framework designed to address motion interference in long-term monitoring. The key insight is that latent patterns within dynamic inter-beat interval (IBI) sequences allow for accurate heartbeat reconstruction from incomplete observations. Leveraging this insight, MaskSense treats motion-affected periods as ”masked” and steady-state periods as ”unmasked”, and employs a contrastive-learning-assisted masked modeling architecture to reconstruct the masked information. Our 400-hour evaluation with 18 participants confirms that MaskSense effectively recovers IBIs in the presence of motion artifacts, paving the way for more natural and unobtrusive RF-based cardiac activity monitoring.
- 9 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Mobile Computing
- Vol. 25 (5) , 7373-7390
MaskSense: Motion-Robust Dynamic IBI Estimation via Deep RF Masked Learning
Although radio frequency (RF) sensing offers a promising approach for monitoring human cardiac activity, it traditionally requires subjects to remain in a steady-state throughout the monitoring process to avoid motion artifacts—an inherently impractical constraint that hampers real-world adoption. However, existing methods either yield incorrect estimates from motion-affected segments or discard them entirely, leading to fragmented data and incomplete observations. To address the challenge, we introduce MaskSense, a novel framework designed to address motion interference in long-term monitoring. The key insight is that latent patterns within dynamic inter-beat interval (IBI) sequences allow for accurate heartbeat reconstruction from incomplete observations. Leveraging this insight, MaskSense treats motion-affected periods as ”masked” and steady-state periods as ”unmasked”, and employs a contrastive-learning-assisted masked modeling architecture to reconstruct the masked information. Our 400-hour evaluation with 18 participants confirms that MaskSense effectively recovers IBIs in the presence of motion artifacts, paving the way for more natural and unobtrusive RF-based cardiac activity monitoring.
- Open Access
- 3 September 2025
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 9 (3) , 1-28
Contactless Fine-grained Cardiac Events Detection and Segmentation with Radio Frequency Signals
The rising prevalence of cardiovascular diseases has created an urgent need for accurate, long-term cardiac monitoring. Traditional electrode-based monitoring devices, which require direct skin contact, can cause discomfort and inconvenience. Although RF-based contactless sensing offers a promising alternative, current solutions struggle to accurately detect and segment fine-grained cardiac events, which are crucial biomarkers for cardiac function assessment and disease diagnosis. Due to spectral leakage caused by respiratory motion and the difficulty in capturing subtle mechanical motions within a single heartbeat cycle, detection and segmentation often suffer from temporal boundary ambiguity and critical event omission. To address these issues, we propose an innovative millimeter-wave (mmWave) fine-grained cardiac event detection and segmentation system that integrates a multi-scale boundary enhancement framework. This framework consists of a multi-scale context fusion module and a boundary-aware enhancement module, which collaboratively mitigate respiratory motion interference and improve feature recognition capabilities. Through dedicated training, our system captures both multi-scale local details and global relationships, enabling user-independent detection and segmentation without the need for subject-specific calibration. The experiments in outpatient of a hospital involving 4,339 participants, including participants with conditions such as Bundle Branch Block (BBB), First-Degree Atrioventricular Block (I-AVB), and T wave abnormalities (T abn.) show that the proposed system achieves an F1 score of 90.6%, outperforming baseline methods, and simultaneously achieves an average estimation error of 14.9 milliseconds for cardiac event intervals, representing a reduction of 5.1 milliseconds compared to the baseline error. The results demonstrate that this system can robustly detect fine-grained cardiac events, thereby providing a more reliable technical foundation for early cardiovascular monitoring.
- 3 September 2025
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 9 (3) , 1-28
Open AccessContactless Fine-grained Cardiac Events Detection and Segmentation with Radio Frequency Signals
The rising prevalence of cardiovascular diseases has created an urgent need for accurate, long-term cardiac monitoring. Traditional electrode-based monitoring devices, which require direct skin contact, can cause discomfort and inconvenience. Although RF-based contactless sensing offers a promising alternative, current solutions struggle to accurately detect and segment fine-grained cardiac events, which are crucial biomarkers for cardiac function assessment and disease diagnosis. Due to spectral leakage caused by respiratory motion and the difficulty in capturing subtle mechanical motions within a single heartbeat cycle, detection and segmentation often suffer from temporal boundary ambiguity and critical event omission. To address these issues, we propose an innovative millimeter-wave (mmWave) fine-grained cardiac event detection and segmentation system that integrates a multi-scale boundary enhancement framework. This framework consists of a multi-scale context fusion module and a boundary-aware enhancement module, which collaboratively mitigate respiratory motion interference and improve feature recognition capabilities. Through dedicated training, our system captures both multi-scale local details and global relationships, enabling user-independent detection and segmentation without the need for subject-specific calibration. The experiments in outpatient of a hospital involving 4,339 participants, including participants with conditions such as Bundle Branch Block (BBB), First-Degree Atrioventricular Block (I-AVB), and T wave abnormalities (T abn.) show that the proposed system achieves an F1 score of 90.6%, outperforming baseline methods, and simultaneously achieves an average estimation error of 14.9 milliseconds for cardiac event intervals, representing a reduction of 5.1 milliseconds compared to the baseline error. The results demonstrate that this system can robustly detect fine-grained cardiac events, thereby providing a more reliable technical foundation for early cardiovascular monitoring.
- Top Cited PapersOpen Access
- 5 December 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-11
Monitoring long-term cardiac activity with contactless radio frequency signals
Cardiovascular diseases claim over 10 million lives annually, highlighting the critical need for long-term monitoring and early detection of cardiac abnormalities. Existing techniques like electrocardiograms (ECG) and Holter are accurate but suffer from discomfort caused by body-attached electrodes. While wearable devices using photoplethysmography offer more convenience, they sacrifice accuracy and are susceptible to environmental interference. Here we present a radio frequency (RF)-based (60 to 64 GHz) sensing system that monitors long-term heart rate variability (HRV) with clinical-grade accuracy. Our system successfully overcomes the orders-larger interference from respiration motion in far-field conditions without any model training. By identifying previously undiscovered frequency ranges (beyond 10-order heartbeat harmonics) where heartbeat information predominates over other motions, we generate prominent heartbeat patterns with harmonics typically considered detrimental. Extensive evaluations, including a large-scale outpatient setting involving 6,222 eligible participants and a long-term daily life scenario, where sleep data was collected over 5 separate random nights over two months and a continuous 21-night period, demonstrate that our system can monitor HRV and identify abnormalities with comparable performance to clinical-grade ECG-based systems. This RF-based HRV sensing system has the potential to support active self-assessment and revolutionize medical prevention with long-term and precise health monitoring.
- 5 December 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-11
Top Cited PapersOpen AccessMonitoring long-term cardiac activity with contactless radio frequency signals
Cardiovascular diseases claim over 10 million lives annually, highlighting the critical need for long-term monitoring and early detection of cardiac abnormalities. Existing techniques like electrocardiograms (ECG) and Holter are accurate but suffer from discomfort caused by body-attached electrodes. While wearable devices using photoplethysmography offer more convenience, they sacrifice accuracy and are susceptible to environmental interference. Here we present a radio frequency (RF)-based (60 to 64 GHz) sensing system that monitors long-term heart rate variability (HRV) with clinical-grade accuracy. Our system successfully overcomes the orders-larger interference from respiration motion in far-field conditions without any model training. By identifying previously undiscovered frequency ranges (beyond 10-order heartbeat harmonics) where heartbeat information predominates over other motions, we generate prominent heartbeat patterns with harmonics typically considered detrimental. Extensive evaluations, including a large-scale outpatient setting involving 6,222 eligible participants and a long-term daily life scenario, where sleep data was collected over 5 separate random nights over two months and a continuous 21-night period, demonstrate that our system can monitor HRV and identify abnormalities with comparable performance to clinical-grade ECG-based systems. This RF-based HRV sensing system has the potential to support active self-assessment and revolutionize medical prevention with long-term and precise health monitoring.
- Open Access
- 22 August 2024
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 8 (3) , 1-28
RF-GymCare: Introducing Respiratory Prior for RF Sensing in Gym Environments
Exercise-induced sudden death has become an increasingly serious health issue in recent years. Fortunately, respiratory monitoring can serve as an effective early prevention solution. In particular, radio frequency (RF) sensing has emerged as a promising solution due to its contactless nature and privacy preservation. Existing RF-based respiratory monitoring solutions for homes, offices, or vehicles would suffer from significant performance degradation when deployed in typical gym workouts, where respiratory and physical movements are mixed in the RF signals in an unpredictable manner, leading to a blind source separation (BSS) problem. What is worse, the prior assumptions of source independence in existing BSS algorithms no longer hold, leaving respiratory monitoring in gym scenarios as an open issue. In this paper, we propose RF-GymCare, which introduces respiratory priors into the BSS problem and utilizes knowledge distillation to transfer these priors, aiming to learn the demixing weight from mixed signals. With the demixing weight, the respiratory signal can be obtained through a linear combination of the mixed signals. Our experiments with 13 hours of data across nine types of exercises demonstrate its superiority over existing methods, achieving a median similarity of 0.75 and a median rate error of 0.5 respiration per minute (RPM), respectively.
- 22 August 2024
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 8 (3) , 1-28
Open AccessRF-GymCare: Introducing Respiratory Prior for RF Sensing in Gym Environments
Exercise-induced sudden death has become an increasingly serious health issue in recent years. Fortunately, respiratory monitoring can serve as an effective early prevention solution. In particular, radio frequency (RF) sensing has emerged as a promising solution due to its contactless nature and privacy preservation. Existing RF-based respiratory monitoring solutions for homes, offices, or vehicles would suffer from significant performance degradation when deployed in typical gym workouts, where respiratory and physical movements are mixed in the RF signals in an unpredictable manner, leading to a blind source separation (BSS) problem. What is worse, the prior assumptions of source independence in existing BSS algorithms no longer hold, leaving respiratory monitoring in gym scenarios as an open issue. In this paper, we propose RF-GymCare, which introduces respiratory priors into the BSS problem and utilizes knowledge distillation to transfer these priors, aiming to learn the demixing weight from mixed signals. With the demixing weight, the respiratory signal can be obtained through a linear combination of the mixed signals. Our experiments with 13 hours of data across nine types of exercises demonstrate its superiority over existing methods, achieving a median similarity of 0.75 and a median rate error of 0.5 respiration per minute (RPM), respectively.
- Open Access
- 2 October 2023
- Published by Association for Computing Machinery (ACM)
- p. 1-15
RF-Search: Searching Unconscious Victim in Smoke Scenes with RF-enabled Drone
Toxic gases inhalation is the most common cause of death in fire scenes, which can make people unconscious and unable to save themselves. Hence, discovering the unconscious victims is crucial to improve their survival rate. In this paper, we propose RF-Search, a victim searching system with RF device mounted on the drone. The challenge mainly comes from the fact that drone motion would overwhelm the subtle vital signs utilized for victim identification. To resolve this problem, we have noted that the physical signature of drone motion has been encoded in stationary object reflections. Leveraging this unique physical signature, we propose to identify the unconscious victim through the spatio-temporal correlation between signals reflected from the victim and the surrounding stationary objects. To extract respiration information of the victim, we propose a motion segmentation module and a motion compensation module to suppress the signal variation caused by drone movement. Extensive experiments have demonstrated that our system could achieve an accuracy of 92.5% for victim identification.
- 2 October 2023
- Published by Association for Computing Machinery (ACM)
- p. 1-15
Open AccessRF-Search: Searching Unconscious Victim in Smoke Scenes with RF-enabled Drone
Toxic gases inhalation is the most common cause of death in fire scenes, which can make people unconscious and unable to save themselves. Hence, discovering the unconscious victims is crucial to improve their survival rate. In this paper, we propose RF-Search, a victim searching system with RF device mounted on the drone. The challenge mainly comes from the fact that drone motion would overwhelm the subtle vital signs utilized for victim identification. To resolve this problem, we have noted that the physical signature of drone motion has been encoded in stationary object reflections. Leveraging this unique physical signature, we propose to identify the unconscious victim through the spatio-temporal correlation between signals reflected from the victim and the surrounding stationary objects. To extract respiration information of the victim, we propose a motion segmentation module and a motion compensation module to suppress the signal variation caused by drone movement. Extensive experiments have demonstrated that our system could achieve an accuracy of 92.5% for victim identification.
- 9 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 10 (23) , 21026-21038
Unsupervised Domain Adaptation for RF-Based Gesture Recognition
Human gesture recognition with radio frequency (RF) signals has attained acclaim due to the omnipresence, privacy protection, and broad coverage nature of RF signals. These gesture recognition systems rely on neural networks trained with a large number of labeled data. However, the recognition model trained with data under certain conditions would suffer from significant performance degradation when applied in practical deployment, which limits the application of gesture recognition systems. In this article, we propose an unsupervised domain adaptation framework for RF-based gesture recognition aiming to enhance the performance of the recognition model in new conditions by making effective use of the unlabeled data from new conditions. We first propose pseudo labeling and consistency regularization to utilize unlabeled data for model training and eliminate the feature discrepancies in different domains. Then we propose a confidence constraint loss to enhance the effectiveness of pseudo labeling, and design two corresponding data augmentation methods based on the characteristic of the RF signals to strengthen the performance of the consistency regularization, which can make the framework more effective and robust. Furthermore, we propose a cross-match loss to integrate the pseudo labeling and consistency regularization, which makes the whole framework simple yet effective. Extensive experiments demonstrate that the proposed framework could achieve 4.35% and 2.25% accuracy improvement comparing with the state-of-the-art methods on public WiFi data set and millimeter wave (mmWave) radar data set, respectively.
- 9 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 10 (23) , 21026-21038
Unsupervised Domain Adaptation for RF-Based Gesture Recognition
Human gesture recognition with radio frequency (RF) signals has attained acclaim due to the omnipresence, privacy protection, and broad coverage nature of RF signals. These gesture recognition systems rely on neural networks trained with a large number of labeled data. However, the recognition model trained with data under certain conditions would suffer from significant performance degradation when applied in practical deployment, which limits the application of gesture recognition systems. In this article, we propose an unsupervised domain adaptation framework for RF-based gesture recognition aiming to enhance the performance of the recognition model in new conditions by making effective use of the unlabeled data from new conditions. We first propose pseudo labeling and consistency regularization to utilize unlabeled data for model training and eliminate the feature discrepancies in different domains. Then we propose a confidence constraint loss to enhance the effectiveness of pseudo labeling, and design two corresponding data augmentation methods based on the characteristic of the RF signals to strengthen the performance of the consistency regularization, which can make the framework more effective and robust. Furthermore, we propose a cross-match loss to integrate the pseudo labeling and consistency regularization, which makes the whole framework simple yet effective. Extensive experiments demonstrate that the proposed framework could achieve 4.35% and 2.25% accuracy improvement comparing with the state-of-the-art methods on public WiFi data set and millimeter wave (mmWave) radar data set, respectively.