JCJinyan Chen

Jinyan Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jinyan Chen has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Baoxin Tao

    Department of Second Dental Center, Shanghai Ninth People's Hospital Shanghai Jiao Tong University School of Medicine Shanghai China

    3 shared publications
  • Feng Wang

    Department of Second Dental Center, Shanghai Ninth People's Hospital Shanghai Jiao Tong University School of Medicine Shanghai China

    3 shared publications
  • Feng Wang

    Oral and Maxillofacial Surgery, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China

    3 shared publications
  • Yiqun Wu

    Department of Second Dental Center, Shanghai Ninth People's Hospital Shanghai Jiao Tong University School of Medicine Shanghai China

    3 shared publications
  • Baoxin Tao

    Department of Second Dental Center, Shanghai Ninth People's Hospital Shanghai Jiao Tong University School of Medicine Shanghai China

    1 shared publication
  • Lijuan Ye

    Department of Second Dental Center, Shanghai Ninth People's Hospital Shanghai Jiao Tong University School of Medicine Shanghai China

    1 shared publication

Latest Publications

  • Open Access

    Current Status and Future Perspectives of Wearable Technologies for Oral Health in Clinical Applications

    by Yao Li, Mu Wang, Siqi Qiu, Jinyan Chen, Feng Wang

    This review aims to assess the clinical performance and application results of oral wearable devices in in vivo trials. Following a systematic search of PubMed, Cochrane, Embase, and Scopus databases up to 15 October 2025, and strict screening in accordance with PRISMA 2020 guidelines, 13 in vivo human trials were finally included for analysis. These were analyzed across four clinical functions: diagnosis, treatment, monitoring, and prevention. These devices have evolved from bulky prototypes into miniaturized, wireless systems with diverse diagnostic and therapeutic functions. Their applications now extend beyond common conditions like caries and bruxism to postoperative recovery and pediatric dental anxiety intervention. The findings show that some devices already offer practical value for clinical screening and auxiliary diagnosis. They demonstrate significant potential in early disease detection and medical cost control. However, development still faces many challenges. Technical issues include limited battery life, insufficient mechanical durability, and wireless transmission constraints within the oral environment. Furthermore, clinical evidence levels remain low, indications are narrow, and dedicated ethical and regulatory frameworks are lacking. Inconsistent regulatory standards, production costs, and clinician adoption hurdles slow its commercial development. In the future, the integration of AI, breakthroughs in energy harvesting, and the creation of digital health platforms will be key to overcoming technical bottlenecks.


  • Accuracy of Zygomatic Implant Placement Using Task‐Autonomous Robotic System or Dynamic Navigation: An In Vitro Study

    by Jinyan Chen, Baoxin Tao, Xinbo Yu, Yiqun Wu, Feng Wang

    Objectives: To evaluate and compare the accuracy of task‐autonomous robot‐assisted implant surgery (RAIS) and dynamic computer‐assisted implant surgery (dCAIS) for zygomatic implant placement.Materials and Methods: Ten atrophic edentulous maxilla models requiring zygomatic implant (ZI) placement were randomly divided into the RAIS and dCAIS groups. Osteotomies and implant placement were performed under the guidance of a task‐autonomous robotic system or dynamic navigation system. A total of 20 ZIs were analyzed. The angular, coronal, lateral coronal, coronal depth, apical, lateral apical, and apical depth deviations were measured and analyzed between the two groups. The primary outcome parameters were the angular deviations between the planned and the placed ZIs. Data was subjected to descriptive and comparative statistical analysis. The significance of inter‐group differences for continuous variables was assessed with Student's two‐sample t‐tests, Welch two‐sample t‐tests, and Mann–Whitney U tests according to the distribution normality and variance homogeneity.Results: ZI placement deviations were compared between the RAIS and dCAIS groups, showing a mean angular deviation of 0.92 ± 0.40° versus 2.03 ± 0.53° (p < 0.001), a mean (±SD) coronal deviation of 0.48 ± 0.25 mm versus 1.29 ± 0.46 mm (p < 0.001), and a mean apical deviation of 0.88 ± 0.28 mm versus 1.96 ± 0.46 mm (p < 0.001).Conclusions: For computer‐guided ZI placement, task‐autonomous RAIS was superior to dCAIS in terms of accuracy.


  • Exploring the Learning Curve of Dental Implant Placement Using a Task‐Autonomous Robotic System Among Young Dentists From Different Specialties—A Pilot Module Study

    by Minjie Zhuang, Jinyan Chen, Baoxin Tao, Meisha Gul, Feng Wang, Yiqun Wu

    Background: The learning curve effect of dynamic computer‐assisted implant surgery (D‐CAIS) was observed among inexperienced novice surgeons. The learning curves can provide valuable information for novice surgeons and valid comparisons between new and conventional techniques. Recently, robotic computer‐assisted implant surgery (R‐CAIS) has shown promise as a novel dental implant surgical technique for both partially and edentulous patients. However, its learning curve remains unknown.Purpose: The aim of this study was to explore the learning curve of dental implant placement surgery with a task‐autonomous robotic system among young dentists with different specialties.Methods and Materials: Four young dentists (mean age: 25.3 ± 1.5 years at the beginning of their first attempt) with equal representation of males and females and with different specialties participated in this study. None of the participants had prior experience in R‐CAIS. Each operator placed eight implants over eight attempts using a semi‐active task‐autonomous robotic system. Among the eight implants, four were straight lateral incisor implants, and four were 30°‐tilted premolar implants. The implants were placed in each dental quadrant of the maxillary and mandibular jaw modules. The operation time was recorded. Coronal, apical, and angular deviations between the planned and actual sites of implant placement were measured by merging preoperative and postoperative cone‐beam computed tomography (CBCT) scans. The data were analyzed with repeated‐measures ANOVA (α = 0.05).Results: The mean time for implant placement was associated with the number of attempts (p < 0.01). The time taken for the second attempt was significantly shorter than that of the first attempt (33.26 vs. 30.47 min; p < 0.001) then it plateaued. Three‐dimensional (3D) angular (p = 0.31), coronal deviation (p = 0.26), and apical deviation (p = 0.06) did not differ significantly among attempts. The mean values and standard deviations of 3D coronal deviation, 3D apical deviation, and 3D angular deviation were 0.71 ± 0.31 mm, 0.72 ± 0.30 mm, and 0.94 ± 0.58°, respectively. Neither the position of the jaw (p > 0.59) nor the tilt angle of the implant (straight or 30°‐tilted, p > 0.85) was related to implant placement accuracy.Conclusions: Dentists quickly learned the basic workflow of R‐CAIS and thus facilitated the clinicians in the mastery of implant placement on edentulous jaw modules, leading to a comparable operating speed and high precision. Moreover, the accuracy of placement of straight and tilted implants in both the maxilla and mandible with R‐CAIS was satisfactory.


  • Accuracy of immediate dental implant placement with task‐autonomous robotic system and navigation system: An in vitro study

    by Jinyan Chen, Minjie Zhuang, Baoxin Tao, Yiqun Wu, Lijuan Ye, Feng Wang

    Objectives: The aim of this study was to compare the accuracy of dental implant placement in a single tooth gap, including the postextraction site and healed site, using a task‐autonomous robotic system and a dynamic navigation system.Materials and Methods: Forty partially edentulous models requiring both immediate and conventional implant placement were randomly divided into a robotic system group and a navigation system group. The coronal, apical, and angular deviations of the implants were measured and assessed between the groups.Results: The deviations in immediate implant placement were compared between the robotic system and dynamic navigation system groups, showing a mean (±SD) coronal deviation of 0.86 ± 0.36 versus 0.70 ± 0.21 mm (p = .101), a mean apical deviation of 0.77 ± 0.34 versus 0.95 ± 0.38 mm (p = .127), and a mean angular deviation of 1.94 ± 0.66° versus 3.44 ± 1.38° (p < .001). At the healed site, significantly smaller coronal deviation (0.46 ± 0.29 vs. 0.70 ± 0.30 mm, p = .005), apical deviation (0.56 ± 0.30 vs. 0.85 ± 0.25 mm, p < .001), and angular deviation (1.36 ± 0.54 vs. 1.80 ± 0.70 mm, p = .034) were found in the robotic system group than in the dynamic navigation group.Conclusions: The position in both immediate and conventional implant placement was more precise with the task‐autonomous robotic system than with the dynamic navigation system. Its performance in actual clinical applications should be confirmed in further trials.