K L Boedeker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
K L Boedeker has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Michael Francis McNitt-Gray
Univ. of California, Los Angeles (United States)
2 shared publications V N Cooper
1 shared publication
Latest Publications
- 8 June 2007
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (14) , 4047-4061
Application of the noise power spectrum in modern diagnostic MDCT: part II. Noise power spectra and signal to noise
Balancing dose and image quality requires signal-to-noise (SNR) metrics which incorporate both the variance and the spatial frequency characteristics of noise. In this study, the non-prewhitening matched filter SNR metric is calculated for 2 mm slices of a 1 cm diameter sphere under three different conditions: (1) constant pixel standard deviation, (2) constant dose and (3) constant reconstruction filter. For the constant pixel standard deviation condition, an increase of 260% in SNR was found with increasing filter sharpness. For constant dose, the SNR remained level for smooth to medium filters, then declined by up to 55% with increasing filter sharpness. For a constant reconstruction filter, the SNR increased with dose, but not as high as photon statistics would predict. However, when structured noise was removed from the noise power spectrum, the SNR did vary with quanta statistics. These results offer protocol design guidance for low-frequency-dominated objects.
- 8 June 2007
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (14) , 4047-4061
Application of the noise power spectrum in modern diagnostic MDCT: part II. Noise power spectra and signal to noise
Balancing dose and image quality requires signal-to-noise (SNR) metrics which incorporate both the variance and the spatial frequency characteristics of noise. In this study, the non-prewhitening matched filter SNR metric is calculated for 2 mm slices of a 1 cm diameter sphere under three different conditions: (1) constant pixel standard deviation, (2) constant dose and (3) constant reconstruction filter. For the constant pixel standard deviation condition, an increase of 260% in SNR was found with increasing filter sharpness. For constant dose, the SNR remained level for smooth to medium filters, then declined by up to 55% with increasing filter sharpness. For a constant reconstruction filter, the SNR increased with dose, but not as high as photon statistics would predict. However, when structured noise was removed from the noise power spectrum, the SNR did vary with quanta statistics. These results offer protocol design guidance for low-frequency-dominated objects.
- 8 June 2007
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (14) , 4027-4046
Application of the noise power spectrum in modern diagnostic MDCT: part I. Measurement of noise power spectra and noise equivalent quanta
Dose reduction efforts in diagnostic CT have brought the tradeoff of dose versus image quality to the forefront. The need for meaningful characterization of image noise beyond that offered by pixel standard deviation is becoming increasingly important. This work aims to study the implementation of the noise power spectrum (NPS) and noise equivalent quanta (NEQ) on modern, multislice diagnostic CT scanners. The details of NPS and NEQ measurement are outlined and special attention is paid to issues unique to multislice CT. Aliasing, filter design and effects of acquisition geometry are investigated. While it was found that both metrics can be implemented in modern CT, it was discovered that NEQ cannot be aptly applied with certain non-traditional reconstruction filters or in helical mode. NPS and NEQ under a variety of conditions are examined. Extensions of NPS and NEQ to uses in protocol standardization are also discussed.
- 8 June 2007
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (14) , 4027-4046
Application of the noise power spectrum in modern diagnostic MDCT: part I. Measurement of noise power spectra and noise equivalent quanta
Dose reduction efforts in diagnostic CT have brought the tradeoff of dose versus image quality to the forefront. The need for meaningful characterization of image noise beyond that offered by pixel standard deviation is becoming increasingly important. This work aims to study the implementation of the noise power spectrum (NPS) and noise equivalent quanta (NEQ) on modern, multislice diagnostic CT scanners. The details of NPS and NEQ measurement are outlined and special attention is paid to issues unique to multislice CT. Aliasing, filter design and effects of acquisition geometry are investigated. While it was found that both metrics can be implemented in modern CT, it was discovered that NEQ cannot be aptly applied with certain non-traditional reconstruction filters or in helical mode. NPS and NEQ under a variety of conditions are examined. Extensions of NPS and NEQ to uses in protocol standardization are also discussed.