Sultan Mohammad Manjur
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sultan Mohammad Manjur has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Adam Skarke
Department of Geosciences Mississippi State University Mississippi State MS USA
2 shared publications - Aleksander Lizunov
Ekaterinburg Eye Microsurgery Center
2 shared publications - Aleksei Zhdanov
VisioMed.AI, Moscow, Russia
2 shared publications - Ali Cafer Gurbuz
Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, USA
2 shared publications - Anton Dolganov
Engineering School of Information Technologies, Telecommunications and Control Systems, Ural Federal University Named after the First President of Russia B. N. Yeltsin, Yekaterinburg 620002, Russia
2 shared publications - Hugo Fernando Posada Quintero
Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA
2 shared publications
Latest Publications
- Open Access
- 22 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 18 (19391404) , 25549-25561
Deep Learning-Based Sequential Processing of Multibeam Echosounder Images for Automated Detection of Seafloor Gas Seep Occurrence
Seafloor gas seeps, primarily methane, play a crucial role in the global carbon cycle, influencing ocean chemistry, biodiversity, and geohazards while signaling potential natural gas reserves. Detecting and monitoring these seeps over time is crucial to understanding underwater resources and their environmental impacts. However, current detection methods rely heavily on human interpretation of water column imagery, limiting efficiency and scalability of the detection process. This study proposes a supervised machine learning (ML) framework that mimics human visual interpretation by analyzing sequences of multibeam echosounder (MBES) water column data, enabling automated seep detection by capturing temporal patterns across frames. Instead of processing only single frames, ML-based detection is developed on a sequence of MBES frames at a time. The model is evaluated on MBES sequences of varying lengths and confidence levels and its performance is compared with single-frame-based detection. Although both approaches perform similarly on low-confidence seep sequences, the sequential model demonstrates a clear advantage in high-confidence cases. Sequential analysis reduces the high false positive rate of the single-frame method by improving precision from 66% to 78%, maintains a more balanced recall of 71%, and achieves a higher overall accuracy of 87%. This approach offers a more robust and reliable seafloor gas seep detection system compared to single-frame-based analysis, highlighting the benefits of leveraging temporal context in water column data.
- 22 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 18 (19391404) , 25549-25561
Open AccessDeep Learning-Based Sequential Processing of Multibeam Echosounder Images for Automated Detection of Seafloor Gas Seep Occurrence
Seafloor gas seeps, primarily methane, play a crucial role in the global carbon cycle, influencing ocean chemistry, biodiversity, and geohazards while signaling potential natural gas reserves. Detecting and monitoring these seeps over time is crucial to understanding underwater resources and their environmental impacts. However, current detection methods rely heavily on human interpretation of water column imagery, limiting efficiency and scalability of the detection process. This study proposes a supervised machine learning (ML) framework that mimics human visual interpretation by analyzing sequences of multibeam echosounder (MBES) water column data, enabling automated seep detection by capturing temporal patterns across frames. Instead of processing only single frames, ML-based detection is developed on a sequence of MBES frames at a time. The model is evaluated on MBES sequences of varying lengths and confidence levels and its performance is compared with single-frame-based detection. Although both approaches perform similarly on low-confidence seep sequences, the sequential model demonstrates a clear advantage in high-confidence cases. Sequential analysis reduces the high false positive rate of the single-frame method by improving precision from 66% to 78%, maintains a more balanced recall of 71%, and achieves a higher overall accuracy of 87%. This approach offers a more robust and reliable seafloor gas seep detection system compared to single-frame-based analysis, highlighting the benefits of leveraging temporal context in water column data.
- Open Access
- 28 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 18 (19391404) , 5633-5645
Automated Detection of Seafloor Gas Seeps in Multibeam Echosounder Data With an Attention-Guided Convolutional Neural Network
Seafloor gas seeps are a globally distributed feature that hold substantial implications for ocean carbon cycling, chemosynthetic ecology, energy production, and geohazards. Detection of seafloor gas seeps currently requires human visual interpretation of sonar water column imagery by a trained individual, which is time consuming, costly, and inconsistent. In this study, we introduce a novel dataset composed of 428,396 high-resolution multibeam echosounder (MBES) sonar water column images annotated for the presence and position of gas bubble plume targets generated by seafloor seeps. Leveraging this dataset for training and validation, we present a machine learning model based on an attention-guided convolutional neural network framework for automated gas seep detection in seafloor environments. Additionally, we present an analysis of a range of processing approaches for MBES sonar water column data, evaluating their impact on the seep detection performance of the machine learning model. Finally, our proposed ML framework underwent a rigorous evaluation using a location-independent validation strategy, achieving an overall accuracy of 87%, with 78% precision and 72% recall rate ensuring robustness and reliability. This research represents a substantial advancement in automated gas seep detection methodology.
- 28 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 18 (19391404) , 5633-5645
Open AccessAutomated Detection of Seafloor Gas Seeps in Multibeam Echosounder Data With an Attention-Guided Convolutional Neural Network
Seafloor gas seeps are a globally distributed feature that hold substantial implications for ocean carbon cycling, chemosynthetic ecology, energy production, and geohazards. Detection of seafloor gas seeps currently requires human visual interpretation of sonar water column imagery by a trained individual, which is time consuming, costly, and inconsistent. In this study, we introduce a novel dataset composed of 428,396 high-resolution multibeam echosounder (MBES) sonar water column images annotated for the presence and position of gas bubble plume targets generated by seafloor seeps. Leveraging this dataset for training and validation, we present a machine learning model based on an attention-guided convolutional neural network framework for automated gas seep detection in seafloor environments. Additionally, we present an analysis of a range of processing approaches for MBES sonar water column data, evaluating their impact on the seep detection performance of the machine learning model. Finally, our proposed ML framework underwent a rigorous evaluation using a location-independent validation strategy, achieving an overall accuracy of 87%, with 78% precision and 72% recall rate ensuring robustness and reliability. This research represents a substantial advancement in automated gas seep detection methodology.
- Open Access
- 11 June 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (6) , 708
OculusGraphy: Signal Analysis of the Electroretinogram in a Rabbit Model of Endophthalmitis Using Discrete and Continuous Wavelet Transforms
Background: The electroretinogram is a clinical test used to assess the function of the photoreceptors and retinal circuits of various cells in the eye, with the recorded waveform being the result of the summated response of neural generators across the retina. Methods: The present investigation involved an analysis of the electroretinogram waveform in both the time and time–frequency domains through the utilization of the discrete wavelet transform and continuous wavelet transform techniques. The primary aim of this study was to monitor and evaluate the effects of treatment in a New Zealand rabbit model of endophthalmitis via electroretinogram waveform analysis and to compare these with normal human electroretinograms. Results: The wavelet scalograms were analyzed using various mother wavelets, including the Daubechies, Ricker, Wavelet Biorthogonal 3.1 (bior3.1), Morlet, Haar, and Gaussian wavelets. Distinctive variances were identified in the wavelet scalograms between rabbit and human electroretinograms. The wavelet scalograms in the rabbit model of endophthalmitis showed recovery with treatment in parallel with the time-domain features. Conclusions: The study compared adult, child, and rabbit electroretinogram responses using DWT and CWT, finding that adult signals had higher power than child signals, and that rabbit signals showed differences in the a-wave and b-wave depending on the type of response tested, while the Haar wavelet was found to be superior in visualizing frequency components in electrophysiological signals for following the treatment of endophthalmitis and may give additional outcome measures for the management of retinal disease.
- 11 June 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (6) , 708
Open AccessOculusGraphy: Signal Analysis of the Electroretinogram in a Rabbit Model of Endophthalmitis Using Discrete and Continuous Wavelet Transforms
Background: The electroretinogram is a clinical test used to assess the function of the photoreceptors and retinal circuits of various cells in the eye, with the recorded waveform being the result of the summated response of neural generators across the retina. Methods: The present investigation involved an analysis of the electroretinogram waveform in both the time and time–frequency domains through the utilization of the discrete wavelet transform and continuous wavelet transform techniques. The primary aim of this study was to monitor and evaluate the effects of treatment in a New Zealand rabbit model of endophthalmitis via electroretinogram waveform analysis and to compare these with normal human electroretinograms. Results: The wavelet scalograms were analyzed using various mother wavelets, including the Daubechies, Ricker, Wavelet Biorthogonal 3.1 (bior3.1), Morlet, Haar, and Gaussian wavelets. Distinctive variances were identified in the wavelet scalograms between rabbit and human electroretinograms. The wavelet scalograms in the rabbit model of endophthalmitis showed recovery with treatment in parallel with the time-domain features. Conclusions: The study compared adult, child, and rabbit electroretinogram responses using DWT and CWT, finding that adult signals had higher power than child signals, and that rabbit signals showed differences in the a-wave and b-wave depending on the type of response tested, while the Haar wavelet was found to be superior in visualizing frequency components in electrophysiological signals for following the treatment of endophthalmitis and may give additional outcome measures for the management of retinal disease.
- Open Access
- 19 May 2023
- Published by MDPI AG in Preprints.org
OculusGraphy: Signal Analysis of the Electroretinogram in a Rabbit Model of Endophthalmitis Using Discrete and Continuous Wavelet Transforms
Background: The electroretinogram is a clinical test used to assess the function of the photoreceptors and retinal circuits of various cells in the eye, with the recorded waveform being the result of the summated response of neural generators across the retina. Methods: The present investigation involved an analysis of the electroretinogram waveform in both the time and time-frequency domain through the utilization of the discrete wavelet transform and continuous wavelet transform techniques. The primary aim of this study was to monitor and evaluate the effects of treatment in a New Zealand rabbit model of endophthalmitis via electroretinogram waveform analysis and to compare these with normal human electroretinograms Results: The wavelet scalograms were analyzed using various mother wavelets, including the Daubechies, Ricker, Wavelet Biorthogonal 3.1 (bior3.1), Morlet, Haar, and Gaussian wavelets. Distinctive variances were identified in the wavelet scalograms between rabbit and human electroretinograms. The wavelet scalograms in the rabbit model of endophthalmitis showed recovery with treatment in parallel with the time -domain features. Conclusions: The study compared Adult, Child, and Rabbit electroretinogram responses using DWT and CWT, finding that Adult signals had higher power than Child signals, and Rabbit signals showed differences in a-wave and b-wave depending on the type of response tested, while Haar Wavelet was found to be superior in visualizing frequency components in electrophysiological signals in following the treatment of endophthalmitis and may give additional outcome measures for the management of retinal disease.
- 19 May 2023
- Published by MDPI AG in Preprints.org
Open AccessOculusGraphy: Signal Analysis of the Electroretinogram in a Rabbit Model of Endophthalmitis Using Discrete and Continuous Wavelet Transforms
Background: The electroretinogram is a clinical test used to assess the function of the photoreceptors and retinal circuits of various cells in the eye, with the recorded waveform being the result of the summated response of neural generators across the retina. Methods: The present investigation involved an analysis of the electroretinogram waveform in both the time and time-frequency domain through the utilization of the discrete wavelet transform and continuous wavelet transform techniques. The primary aim of this study was to monitor and evaluate the effects of treatment in a New Zealand rabbit model of endophthalmitis via electroretinogram waveform analysis and to compare these with normal human electroretinograms Results: The wavelet scalograms were analyzed using various mother wavelets, including the Daubechies, Ricker, Wavelet Biorthogonal 3.1 (bior3.1), Morlet, Haar, and Gaussian wavelets. Distinctive variances were identified in the wavelet scalograms between rabbit and human electroretinograms. The wavelet scalograms in the rabbit model of endophthalmitis showed recovery with treatment in parallel with the time -domain features. Conclusions: The study compared Adult, Child, and Rabbit electroretinogram responses using DWT and CWT, finding that Adult signals had higher power than Child signals, and Rabbit signals showed differences in a-wave and b-wave depending on the type of response tested, while Haar Wavelet was found to be superior in visualizing frequency components in electrophysiological signals in following the treatment of endophthalmitis and may give additional outcome measures for the management of retinal disease.