Rodrigo Ruano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rodrigo Ruano has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Marcelo Zugaib
Disciplina de Obstetrícia, Departamento de Obstetrícia e Ginecologia, Faculdade de Medicina da Universidade de São Paulo
6 shared publications - Uenis Tannuri
Universidade de São Paulo, Brazil
4 shared publications Marcelo Zugaib
Department of Obstetrics and Gynecology, Faculty of Medicine, Universidade de São Paulo, São Paulo, Brazil
3 shared publications- Juliana Alvares Duarte Bonini Campos
Universidade Estadual Paulista, Brazil
2 shared publications M. M. da Silva
Department of Pediatric Surgery, Faculdade de Medicina, Universidade de São Paulo, São Paulo, Brazil
2 shared publicationsMarcos Marques da Silva
Department of Pediatric Surgery, Faculty of Medicine, Universidade de São Paulo, São Paulo, Brazil
2 shared publications
Latest Publications
- 26 June 2014
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 44 (2) , 238-240
Cystoscopic placement of transurethral stent in a fetus with urethral stenosis
We report the case of a fetus with severe megabladder, displaying the ‘keyhole’ sign on ultrasound imaging, that underwent cystoscopy at 22 weeks' gestation. There was a familial history of mild urethral atresia. Fetal cystoscopy revealed congenital urethral atresia. A guide wire was advanced through the fetal urethra and a transurethral vesicoamniotic stent was placed successfully. The fetus was delivered at 36 weeks' gestation and postnatal cystoscopy confirmed the absence of posterior urethral valves or urethral atresia. The infant was 5 years old with normal renal function at the time of writing. We conclude that fetal cystoscopic placement of a transurethral stent for congenital urethral stenosis is feasible. Copyright © 2013 ISUOG. Published by John Wiley & Sons Ltd
- 26 June 2014
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 44 (2) , 238-240
Cystoscopic placement of transurethral stent in a fetus with urethral stenosis
We report the case of a fetus with severe megabladder, displaying the ‘keyhole’ sign on ultrasound imaging, that underwent cystoscopy at 22 weeks' gestation. There was a familial history of mild urethral atresia. Fetal cystoscopy revealed congenital urethral atresia. A guide wire was advanced through the fetal urethra and a transurethral vesicoamniotic stent was placed successfully. The fetus was delivered at 36 weeks' gestation and postnatal cystoscopy confirmed the absence of posterior urethral valves or urethral atresia. The infant was 5 years old with normal renal function at the time of writing. We conclude that fetal cystoscopic placement of a transurethral stent for congenital urethral stenosis is feasible. Copyright © 2013 ISUOG. Published by John Wiley & Sons Ltd
- Open Access
- 1 March 2013
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 32 (3) , 413-417
Quantitative Lung Index, Contralateral Lung Area, or Lung-to-Head Ratio to Predict the Neonatal Outcome in Isolated Congenital Diaphragmatic Hernia?
Objectives To estimate the accuracy of the quantitative lung index and contralateral lung area for prediction of the neonatal outcome in isolated congenital diaphragmatic hernia in comparison to other available prediction models. Methods Between January 2004 and December 2010, 108 fetuses with isolated (82 left‐sided and 26 right‐sided) congenital diaphragmatic hernia were prospectively evaluated. The quantitative lung index and observed‐to‐expected contralateral lung area were measured and compared to the neonatal survival rate and severe postnatal pulmonary arterial hypertension, along with the lung‐to‐head ratio, observed‐to‐expected lung‐to‐head ratio, and observed‐to‐expected total lung volume. Results Overall neonatal mortality was 64.8% (70 of 108). Severe pulmonary arterial hypertension was diagnosed in 68 (63.0%) of the cases, which was associated with neonatal death (P < .001). Both the quantitative lung index and observed‐to‐expected contralateral lung area were significantly associated with neonatal survival and pulmonary arterial hypertension (P < .001), with accuracy to predict survival of 70.9% and 70.0%, respectively, and accuracy to predict hypertension of 78.7% and 72.0%; however, they were both less accurate than the observed‐to‐expected total lung volume (83.3% and 86.1%; P < .01). The lung‐to‐head ratio (73.1% and 78.7%) and observed‐to‐expected lung‐to‐head ratio (75.9% and 72.2%; P > .05) had similar accuracy as the quantitative lung index and observed‐to‐expected contralateral lung area. Conclusions The observed‐to‐expected total lung volume is the most accurate predictor of the neonatal outcome in cases of isolated congenital diaphragmatic hernia. Both the quantitative lung index and observed‐to‐expected contralateral lung area, albeit reasonably accurate, do not produce the same level of accuracy and render similar results as the lung‐to‐head ratio and observed‐to‐expected lung‐to‐head ratio.
- 1 March 2013
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 32 (3) , 413-417
Open AccessQuantitative Lung Index, Contralateral Lung Area, or Lung-to-Head Ratio to Predict the Neonatal Outcome in Isolated Congenital Diaphragmatic Hernia?
Objectives To estimate the accuracy of the quantitative lung index and contralateral lung area for prediction of the neonatal outcome in isolated congenital diaphragmatic hernia in comparison to other available prediction models. Methods Between January 2004 and December 2010, 108 fetuses with isolated (82 left‐sided and 26 right‐sided) congenital diaphragmatic hernia were prospectively evaluated. The quantitative lung index and observed‐to‐expected contralateral lung area were measured and compared to the neonatal survival rate and severe postnatal pulmonary arterial hypertension, along with the lung‐to‐head ratio, observed‐to‐expected lung‐to‐head ratio, and observed‐to‐expected total lung volume. Results Overall neonatal mortality was 64.8% (70 of 108). Severe pulmonary arterial hypertension was diagnosed in 68 (63.0%) of the cases, which was associated with neonatal death (P < .001). Both the quantitative lung index and observed‐to‐expected contralateral lung area were significantly associated with neonatal survival and pulmonary arterial hypertension (P < .001), with accuracy to predict survival of 70.9% and 70.0%, respectively, and accuracy to predict hypertension of 78.7% and 72.0%; however, they were both less accurate than the observed‐to‐expected total lung volume (83.3% and 86.1%; P < .01). The lung‐to‐head ratio (73.1% and 78.7%) and observed‐to‐expected lung‐to‐head ratio (75.9% and 72.2%; P > .05) had similar accuracy as the quantitative lung index and observed‐to‐expected contralateral lung area. Conclusions The observed‐to‐expected total lung volume is the most accurate predictor of the neonatal outcome in cases of isolated congenital diaphragmatic hernia. Both the quantitative lung index and observed‐to‐expected contralateral lung area, albeit reasonably accurate, do not produce the same level of accuracy and render similar results as the lung‐to‐head ratio and observed‐to‐expected lung‐to‐head ratio.
- Open Access
- 1 November 2012
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 31 (11) , 1731-1739
Three-Dimensional Ultrasonographic Assessment of Fetal Total Lung Volume as a Prognostic Factor in Primary Pleural Effusion
Objectives The purpose of this study was to predict perinatal outcomes using fetal total lung volumes assessed by 3‐dimensional ultrasonography (3DUS) in primary pleural effusion. Methods Between July 2005 and July 2010, total lung volumes were prospectively estimated in fetuses with primary pleural effusion by 3DUS using virtual organ computer‐aided analysis software. The first and last US examinations were considered in the analysis. The observed/expected total lung volumes were calculated. Main outcomes were perinatal death (up to 28 days of life) and respiratory morbidity (orotracheal intubation with mechanical respiratory support >48 hours). Results Twelve of 19 fetuses (63.2%) survived. Among the survivors, 7 (58.3%) had severe respiratory morbidity. The observed/expected total lung volume at the last US examination before birth was significantly associated with perinatal death (P < .01) and respiratory morbidity (P < .01) as well as fetal hydrops (P < .01) and bilateral effusion (P = .01). Conclusions Fetal total lung volumes may be useful for the prediction of perinatal outcomes in primary pleural effusion.
- 1 November 2012
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 31 (11) , 1731-1739
Open AccessThree-Dimensional Ultrasonographic Assessment of Fetal Total Lung Volume as a Prognostic Factor in Primary Pleural Effusion
Objectives The purpose of this study was to predict perinatal outcomes using fetal total lung volumes assessed by 3‐dimensional ultrasonography (3DUS) in primary pleural effusion. Methods Between July 2005 and July 2010, total lung volumes were prospectively estimated in fetuses with primary pleural effusion by 3DUS using virtual organ computer‐aided analysis software. The first and last US examinations were considered in the analysis. The observed/expected total lung volumes were calculated. Main outcomes were perinatal death (up to 28 days of life) and respiratory morbidity (orotracheal intubation with mechanical respiratory support >48 hours). Results Twelve of 19 fetuses (63.2%) survived. Among the survivors, 7 (58.3%) had severe respiratory morbidity. The observed/expected total lung volume at the last US examination before birth was significantly associated with perinatal death (P < .01) and respiratory morbidity (P < .01) as well as fetal hydrops (P < .01) and bilateral effusion (P = .01). Conclusions Fetal total lung volumes may be useful for the prediction of perinatal outcomes in primary pleural effusion.
- 18 September 2012
- Published by Wiley in Prenatal Diagnosis
- Vol. 32 (12) , 1127-1132
Percutaneous laser ablation under ultrasound guidance for fetal hyperechogenic microcystic lung lesions with hydrops: a single center cohort and a literature review
Objective: To evaluate the perinatal outcomes in hydropic fetuses with congenital microcystic pulmonary lesions that underwent percutaneous, invasive, laser therapy.Method: This retrospective study reviews the literature and our experience between 2004 and 2010. Characteristics of the cystic lung lesions, liquor volume (presence of polyhydramnios or not), localization of ablation (vascular vs interstitial) and gestational age at which the procedure was performed were related to outcome (survival).Results: In total, 16 fetuses with congenital lung lesions underwent ‘invasive’ percutaneous laser ablation, seven performed in our center and nine published cases. Survival rate was higher in fetuses with a subsequent postnatal diagnosis of bronchopulmonary sequestration (87.5%) compared with congenital adenomatoid malformation (28.6%; p = 0.04). The technique of vascular ablation was more successful (100%) than interstitial ablation (25.0%, p < 0.01).Conclusion: Percutaneous vascular laser ablation seems to be effective for bronchopulmonary sequestration in hydropic fetuses. Outcomes were worst following interstitial ablation for microcystic congenital adenomatoid with hydrops. © 2012 John Wiley & Sons, Ltd.
- 18 September 2012
- Published by Wiley in Prenatal Diagnosis
- Vol. 32 (12) , 1127-1132
Percutaneous laser ablation under ultrasound guidance for fetal hyperechogenic microcystic lung lesions with hydrops: a single center cohort and a literature review
Objective: To evaluate the perinatal outcomes in hydropic fetuses with congenital microcystic pulmonary lesions that underwent percutaneous, invasive, laser therapy.Method: This retrospective study reviews the literature and our experience between 2004 and 2010. Characteristics of the cystic lung lesions, liquor volume (presence of polyhydramnios or not), localization of ablation (vascular vs interstitial) and gestational age at which the procedure was performed were related to outcome (survival).Results: In total, 16 fetuses with congenital lung lesions underwent ‘invasive’ percutaneous laser ablation, seven performed in our center and nine published cases. Survival rate was higher in fetuses with a subsequent postnatal diagnosis of bronchopulmonary sequestration (87.5%) compared with congenital adenomatoid malformation (28.6%; p = 0.04). The technique of vascular ablation was more successful (100%) than interstitial ablation (25.0%, p < 0.01).Conclusion: Percutaneous vascular laser ablation seems to be effective for bronchopulmonary sequestration in hydropic fetuses. Outcomes were worst following interstitial ablation for microcystic congenital adenomatoid with hydrops. © 2012 John Wiley & Sons, Ltd.
- 10 February 2012
- Published by CSIRO Publishing in Reproduction, Fertility and Development
- Vol. 24 (6) , 851-858
Expression of angiogenic factors in placenta of stressed rats
The aim of the present study was to analyse the influence of stress on pregnant rats, particularly in terms of maternal, placental and fetal weight, placental morphology and placental gene expression of the angiogenic factors Vegfa and Pgf and their receptors. The parameters were evaluated on gestation Day 20. Maternal, fetal and placental weights were statistically lower in stressed animals than controls, suggesting abnormalities in gestational physiology. Morphologically the placentas of rats subjected to stress were reduced in size and weight, with few glycogen cells and a significant increase in the number of apoptotic cells. Stress caused an increase in placental gene expression of Vegfa (P < 0.05) and a reduction in Pgf, Flt1 and Kdr expression (P < 0.05). It has been suggested that increased VEGF is associated with vasodilatation and hypotension, but in this model persistent hypertension was present. This study suggests that the limited hypotensive Vegfa response to stress-induced hypertension could result from reduced expression of Flt1/Kdr disrupting specific VEGF pathways. These findings may elucidate one of the multiple possible factors underlying how stress modulates placental physiology, and could aid the understanding of stress-induced gestational disorders.
- 10 February 2012
- Published by CSIRO Publishing in Reproduction, Fertility and Development
- Vol. 24 (6) , 851-858
Expression of angiogenic factors in placenta of stressed rats
The aim of the present study was to analyse the influence of stress on pregnant rats, particularly in terms of maternal, placental and fetal weight, placental morphology and placental gene expression of the angiogenic factors Vegfa and Pgf and their receptors. The parameters were evaluated on gestation Day 20. Maternal, fetal and placental weights were statistically lower in stressed animals than controls, suggesting abnormalities in gestational physiology. Morphologically the placentas of rats subjected to stress were reduced in size and weight, with few glycogen cells and a significant increase in the number of apoptotic cells. Stress caused an increase in placental gene expression of Vegfa (P < 0.05) and a reduction in Pgf, Flt1 and Kdr expression (P < 0.05). It has been suggested that increased VEGF is associated with vasodilatation and hypotension, but in this model persistent hypertension was present. This study suggests that the limited hypotensive Vegfa response to stress-induced hypertension could result from reduced expression of Flt1/Kdr disrupting specific VEGF pathways. These findings may elucidate one of the multiple possible factors underlying how stress modulates placental physiology, and could aid the understanding of stress-induced gestational disorders.
- 23 December 2011
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 39 (1) , 42-49
Prediction and probability of neonatal outcome in isolated congenital diaphragmatic hernia using multiple ultrasound parameters
Objectives: To evaluate the accuracy and probabilities of different fetal ultrasound parameters to predict neonatal outcome in isolated congenital diaphragmatic hernia (CDH).Methods: Between January 2004 and December 2010, we evaluated prospectively 108 fetuses with isolated CDH (82 left‐sided and 26 right‐sided). The following parameters were evaluated: gestational age at diagnosis, side of the diaphragmatic defect, presence of polyhydramnios, presence of liver herniated into the fetal thorax (liver‐up), lung‐to‐head ratio (LHR) and observed/expected LHR (o/e‐LHR), observed/expected contralateral and total fetal lung volume (o/e‐ContFLV and o/e‐TotFLV) ratios, ultrasonographic fetal lung volume/fetal weight ratio (US‐FLW), observed/expected contralateral and main pulmonary artery diameter (o/e‐ContPA and o/e‐MPA) ratios and the contralateral vascularization index (Cont‐VI). The outcomes were neonatal death and severe postnatal pulmonary arterial hypertension (PAH).Results: Neonatal mortality was 64.8% (70/108). Severe PAH was diagnosed in 68 (63.0%) cases, of which 63 died neonatally (92.6%) (P < 0.001). Gestational age at diagnosis, side of the defect and polyhydramnios were not associated with poor outcome (P > 0.05). LHR, o/e‐LHR, liver‐up, o/e‐ContFLV, o/e‐TotFLV, US‐FLW, o/e‐ContPA, o/e‐MPA and Cont‐VI were associated with both neonatal death and severe postnatal PAH (P < 0.001). Receiver–operating characteristics curves indicated that measuring total lung volumes (o/e‐TotFLV and US‐FLW) was more accurate than was considering only the contralateral lung sizes (LHR, o/e‐LHR and o/e‐ContFLV; P < 0.05), and Cont‐VI was the most accurate ultrasound parameter to predict neonatal death and severe PAH (P < 0.001).Conclusions: Evaluating total lung volumes is more accurate than is measuring only the contralateral lung size. Evaluating pulmonary vascularization (Cont‐VI) is the most accurate predictor of neonatal outcome. Estimating the probability of survival and severe PAH allows classification of cases according to prognosis. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.
- 23 December 2011
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 39 (1) , 42-49
Prediction and probability of neonatal outcome in isolated congenital diaphragmatic hernia using multiple ultrasound parameters
Objectives: To evaluate the accuracy and probabilities of different fetal ultrasound parameters to predict neonatal outcome in isolated congenital diaphragmatic hernia (CDH).Methods: Between January 2004 and December 2010, we evaluated prospectively 108 fetuses with isolated CDH (82 left‐sided and 26 right‐sided). The following parameters were evaluated: gestational age at diagnosis, side of the diaphragmatic defect, presence of polyhydramnios, presence of liver herniated into the fetal thorax (liver‐up), lung‐to‐head ratio (LHR) and observed/expected LHR (o/e‐LHR), observed/expected contralateral and total fetal lung volume (o/e‐ContFLV and o/e‐TotFLV) ratios, ultrasonographic fetal lung volume/fetal weight ratio (US‐FLW), observed/expected contralateral and main pulmonary artery diameter (o/e‐ContPA and o/e‐MPA) ratios and the contralateral vascularization index (Cont‐VI). The outcomes were neonatal death and severe postnatal pulmonary arterial hypertension (PAH).Results: Neonatal mortality was 64.8% (70/108). Severe PAH was diagnosed in 68 (63.0%) cases, of which 63 died neonatally (92.6%) (P < 0.001). Gestational age at diagnosis, side of the defect and polyhydramnios were not associated with poor outcome (P > 0.05). LHR, o/e‐LHR, liver‐up, o/e‐ContFLV, o/e‐TotFLV, US‐FLW, o/e‐ContPA, o/e‐MPA and Cont‐VI were associated with both neonatal death and severe postnatal PAH (P < 0.001). Receiver–operating characteristics curves indicated that measuring total lung volumes (o/e‐TotFLV and US‐FLW) was more accurate than was considering only the contralateral lung sizes (LHR, o/e‐LHR and o/e‐ContFLV; P < 0.05), and Cont‐VI was the most accurate ultrasound parameter to predict neonatal death and severe PAH (P < 0.001).Conclusions: Evaluating total lung volumes is more accurate than is measuring only the contralateral lung size. Evaluating pulmonary vascularization (Cont‐VI) is the most accurate predictor of neonatal outcome. Estimating the probability of survival and severe PAH allows classification of cases according to prognosis. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.
- Top Cited Papers
- 14 December 2011
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 39 (1) , 20-27
A randomized controlled trial of fetal endoscopic tracheal occlusion versus postnatal management of severe isolated congenital diaphragmatic hernia
Objective: Severe pulmonary hypoplasia and pulmonary arterial hypertension are associated with reduced survival in congenital diaphragmatic hernia (CDH). We aimed to determine whether fetal endoscopic tracheal occlusion (FETO) improves survival in cases of severe isolated CDH.Methods: Between May 2008 and July 2010, patients whose fetuses had severe isolated CDH (lung‐to‐head ratio < 1.0, liver herniation into the thoracic cavity and no other detectable anomalies) were assigned randomly to FETO or to no fetal intervention (controls). FETO was performed under maternal epidural anesthesia supplemented with fetal intramuscular anesthesia. Tracheal balloon placement was achieved with ultrasound guidance and fetoscopy between 26 and 30 weeks of gestation. All cases that underwent FETO were delivered by the EXIT procedure. Postnatal therapy was the same for both treated fetuses and controls. The primary outcome was survival to 6 months of age. Other maternal and neonatal outcomes were also evaluated.Results: Twenty patients were enrolled randomly to FETO and 21 patients to standard postnatal management. The mean gestational age at randomization was similar in both groups (P = 0.83). Delivery occurred at 35.6 ± 2.4 weeks in the FETO group and at 37.4 ± 1.9 weeks in the controls (P < 0.01). In the intention‐to‐treat analysis, 10/20 (50.0%) infants in the FETO group survived, while 1/21 (4.8%) controls survived (relative risk (RR), 10.5 (95% CI, 1.5–74.7), P < 0.01). In the received‐treatment analysis, 10/19 (52.6%) infants in the FETO group and 1/19 (5.3%) controls survived (RR, 10.0 (95% CI, 1.4–70.6) P < 0.01).Conclusion: FETO improves neonatal survival in cases with isolated severe CDH. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.
- 14 December 2011
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 39 (1) , 20-27
Top Cited PapersA randomized controlled trial of fetal endoscopic tracheal occlusion versus postnatal management of severe isolated congenital diaphragmatic hernia
Objective: Severe pulmonary hypoplasia and pulmonary arterial hypertension are associated with reduced survival in congenital diaphragmatic hernia (CDH). We aimed to determine whether fetal endoscopic tracheal occlusion (FETO) improves survival in cases of severe isolated CDH.Methods: Between May 2008 and July 2010, patients whose fetuses had severe isolated CDH (lung‐to‐head ratio < 1.0, liver herniation into the thoracic cavity and no other detectable anomalies) were assigned randomly to FETO or to no fetal intervention (controls). FETO was performed under maternal epidural anesthesia supplemented with fetal intramuscular anesthesia. Tracheal balloon placement was achieved with ultrasound guidance and fetoscopy between 26 and 30 weeks of gestation. All cases that underwent FETO were delivered by the EXIT procedure. Postnatal therapy was the same for both treated fetuses and controls. The primary outcome was survival to 6 months of age. Other maternal and neonatal outcomes were also evaluated.Results: Twenty patients were enrolled randomly to FETO and 21 patients to standard postnatal management. The mean gestational age at randomization was similar in both groups (P = 0.83). Delivery occurred at 35.6 ± 2.4 weeks in the FETO group and at 37.4 ± 1.9 weeks in the controls (P < 0.01). In the intention‐to‐treat analysis, 10/20 (50.0%) infants in the FETO group survived, while 1/21 (4.8%) controls survived (relative risk (RR), 10.5 (95% CI, 1.5–74.7), P < 0.01). In the received‐treatment analysis, 10/19 (52.6%) infants in the FETO group and 1/19 (5.3%) controls survived (RR, 10.0 (95% CI, 1.4–70.6) P < 0.01).Conclusion: FETO improves neonatal survival in cases with isolated severe CDH. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.
- Open Access
- 1 July 2008
- Published by FapUNIFESP (SciELO) in Sao Paulo Medical Journal
- Vol. 126 (4) , 239-241
To shunt or not to shunt a pulmonary adenomatoid cystic malformation after 33 weeks of gestation: a case report
Macrocystic adenomatoid malformation of the lung can cause severe mediastinal shift, hydrops and polyhydramnios, thereby increasing the risk of perinatal deaths. After 33 weeks of gestation, repeated puncturing of the cyst is recommended. We present a case in which a cyst-amniotic shunt was placed instead of performing this procedure. A cyst-amniotic shunt was placed at 33 weeks of gestation because of a large macrocystic adenomatoid malformation of the lung associated with severe mediastinal shift and polyhydramnios. Although it was confirmed that the catheter was in the correct place, the cyst increased in size again two weeks later, associated with repetition of polyhydramnios. It was postulated that the catheter was blocked, and we chose to place another catheter instead of performing repeated punctures. The cystic volume, polyhydramnios and mediastinal shift regressed progressively. At 38.5 weeks, a 3,310/g male infant was delivered without presenting any respiratory distress. The infant underwent thoracotomy on the 15th day of life. Thus, in the present study, we discuss the possibility of placing a cyst-amniotic shunt instead of performing repeated cystic punctures, even at a gestational age close to full term.
- 1 July 2008
- Published by FapUNIFESP (SciELO) in Sao Paulo Medical Journal
- Vol. 126 (4) , 239-241
Open AccessTo shunt or not to shunt a pulmonary adenomatoid cystic malformation after 33 weeks of gestation: a case report
Macrocystic adenomatoid malformation of the lung can cause severe mediastinal shift, hydrops and polyhydramnios, thereby increasing the risk of perinatal deaths. After 33 weeks of gestation, repeated puncturing of the cyst is recommended. We present a case in which a cyst-amniotic shunt was placed instead of performing this procedure. A cyst-amniotic shunt was placed at 33 weeks of gestation because of a large macrocystic adenomatoid malformation of the lung associated with severe mediastinal shift and polyhydramnios. Although it was confirmed that the catheter was in the correct place, the cyst increased in size again two weeks later, associated with repetition of polyhydramnios. It was postulated that the catheter was blocked, and we chose to place another catheter instead of performing repeated punctures. The cystic volume, polyhydramnios and mediastinal shift regressed progressively. At 38.5 weeks, a 3,310/g male infant was delivered without presenting any respiratory distress. The infant underwent thoracotomy on the 15th day of life. Thus, in the present study, we discuss the possibility of placing a cyst-amniotic shunt instead of performing repeated cystic punctures, even at a gestational age close to full term.
- 1 May 2008
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 190 (5) , 1216-1219
Predicting Neonatal Deaths and Pulmonary Hypoplasia in Isolated Congenital Diaphragmatic Hernia Using the Sonographic Fetal Lung Volume–Body Weight Ratio
OBJECTIVE. The objective of our study was to evaluate the potential of the sonographic fetal lung volume–body weight ratio to predict neonatal deaths and pulmonary hypoplasia in fetuses with isolated congenital diaphragmatic hernia (CDH).SUBJECTS AND METHODS. Between January 2002 and December 2004, 40 fetuses with isolated CDH and 450 control subjects were prospectively evaluated in two centers. Fetal lung volumes were estimated on 3D sonography using the rotational technique and fetal weight on 2D sonography using the Hadlock equation. The ratio of sonographic fetal lung volume to body weight was calculated in each case and was correlated with neonatal deaths using the Mann-Whitney U test. Accuracies of the ratio in predicting neonatal deaths and pathologic diagnosis of pulmonary hypoplasia were also evaluated.RESULTS. The ratio of sonographic fetal lung volume to body weight is constant throughout gestation, with a mean value of 0.025. The ratio was significantly lower in neonates that died (median, 0.0...
- 1 May 2008
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 190 (5) , 1216-1219
Predicting Neonatal Deaths and Pulmonary Hypoplasia in Isolated Congenital Diaphragmatic Hernia Using the Sonographic Fetal Lung Volume–Body Weight Ratio
OBJECTIVE. The objective of our study was to evaluate the potential of the sonographic fetal lung volume–body weight ratio to predict neonatal deaths and pulmonary hypoplasia in fetuses with isolated congenital diaphragmatic hernia (CDH).SUBJECTS AND METHODS. Between January 2002 and December 2004, 40 fetuses with isolated CDH and 450 control subjects were prospectively evaluated in two centers. Fetal lung volumes were estimated on 3D sonography using the rotational technique and fetal weight on 2D sonography using the Hadlock equation. The ratio of sonographic fetal lung volume to body weight was calculated in each case and was correlated with neonatal deaths using the Mann-Whitney U test. Accuracies of the ratio in predicting neonatal deaths and pathologic diagnosis of pulmonary hypoplasia were also evaluated.RESULTS. The ratio of sonographic fetal lung volume to body weight is constant throughout gestation, with a mean value of 0.025. The ratio was significantly lower in neonates that died (median, 0.0...