Francisco Ubiratan Ferreira de Campos
Research Subjects
Francisco Ubiratan Ferreira de Campos has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Cecilia Pedroso Turssi
Faculdade São Leopoldo Mandic, Campinas, Brazil
2 shared publications - Flávia Lucisano Botelho Do Amaral
Faculdade São Leopoldo Mandic, Brazil
2 shared publications - Roberta Tarkany Basting
Faculdade São Leopoldo Mandic, Campinas, Brazil
2 shared publications - Alexandre Sigrist De Martin
São Leopoldo Mandic University
1 shared publication - Carlos Eduardo Fontana
Pontificia Universidade Católica de Campinas, Programa de Pós-Graduação em Ciências da Saúde,Campinas, São Paulo, Brazil
1 shared publication - Carlos Eduardo da Silveira Bueno
São Leopoldo Mandic University
1 shared publication
Latest Publications
- Open Access
- 1 June 2023
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 34 (3) , 33-41
Analysis of antimicrobial efficacy of sodium hypochlorite and ozonated water against biofilm in oval canals
This in vitro study compared the antimicrobial efficacy of 2.5% sodium hypochlorite (NaOCl) and 8 µg/mL ozonated water agitated by passive ultrasonic irrigation (PUI) or PUI combined with EndoActivator (EA) against mature multispecies biofilm. One hundred and five oval-shaped mandibular premolars were instrumented, sterilized, and inoculated with Enterococcus faecalis, Candida albicans, and Staphylococcus aureus, divided into: control group - saline; O3 group - ozonated water; O3 PUI group - ozonated water with PUI agitation; O3 PUI+EA group - ozonated water with PUI+EA agitation; NaOCl group - NaOCl; NaOCl PUI group - NaOCl with PUI agitation; and NaOCl PUI+EA group - NaOCl with PUI+EA agitation. Microbiological samples were collected before (S1) and after (S2) the disinfection procedures and the data were statistically analyzed using the Kruskal-Wallis test. In the culture method, there was significant disinfection in the O3 PUI+EA, NaOCl, NaOCl PUI, and NaOCl PUI+EA groups (p˂0.05). The combination of NaOCl with PUI+EA reduced microbial counts to zero (p˂0.05). In the qPCR method, there was a significant reduction in the total count of viable microorganisms in the O3 PUI, O3 PUI+EA, NaOCl, NaOCl PUI, and NaOCl PUI+EA groups (p˂0.05). It can be concluded that 2.5% NaOCl with and without agitation, as well as 8 µg/mL ozonated water with its action enhanced by the agitation techniques, were effective in root canal disinfection, and their antimicrobial efficacy is related to the microorganisms present in the biofilm.
- 1 June 2023
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 34 (3) , 33-41
Open AccessAnalysis of antimicrobial efficacy of sodium hypochlorite and ozonated water against biofilm in oval canals
This in vitro study compared the antimicrobial efficacy of 2.5% sodium hypochlorite (NaOCl) and 8 µg/mL ozonated water agitated by passive ultrasonic irrigation (PUI) or PUI combined with EndoActivator (EA) against mature multispecies biofilm. One hundred and five oval-shaped mandibular premolars were instrumented, sterilized, and inoculated with Enterococcus faecalis, Candida albicans, and Staphylococcus aureus, divided into: control group - saline; O3 group - ozonated water; O3 PUI group - ozonated water with PUI agitation; O3 PUI+EA group - ozonated water with PUI+EA agitation; NaOCl group - NaOCl; NaOCl PUI group - NaOCl with PUI agitation; and NaOCl PUI+EA group - NaOCl with PUI+EA agitation. Microbiological samples were collected before (S1) and after (S2) the disinfection procedures and the data were statistically analyzed using the Kruskal-Wallis test. In the culture method, there was significant disinfection in the O3 PUI+EA, NaOCl, NaOCl PUI, and NaOCl PUI+EA groups (p˂0.05). The combination of NaOCl with PUI+EA reduced microbial counts to zero (p˂0.05). In the qPCR method, there was a significant reduction in the total count of viable microorganisms in the O3 PUI, O3 PUI+EA, NaOCl, NaOCl PUI, and NaOCl PUI+EA groups (p˂0.05). It can be concluded that 2.5% NaOCl with and without agitation, as well as 8 µg/mL ozonated water with its action enhanced by the agitation techniques, were effective in root canal disinfection, and their antimicrobial efficacy is related to the microorganisms present in the biofilm.
- Open Access
- 29 April 2023
- Published by Sociedad Argentina de Investigacion Odontologica in Acta Odontológica Latinoamericana
- Vol. 36 (1) , 15-23
Ozone gas therapy for tooth bleaching preserves enamel microhardness, roughness and surface micromorphology
After ozone therapy for bleaching, it is important to evaluate enamel surface properties, to ensure that bleaching provides adequate conditions for sound dental substrate. Aim: The aim of this in vitro study was to evaluate the effects of a bleaching treatment with 10% carbamide peroxide (CP), with or without ozone (O), on the microhardness, roughness and micromorphology of the enamel surface. Materials and Method: Bovine enamel blocks were planed and distributed among the following three bleaching treatment groups (n=10): CP - 1 hour per day/14 days (Opalescence PF 10%/ Ultradent); O - 1 hour per day every 3 days/3 sessions (Medplus V Philozon, 60 mcg/mL and oxygen flow rate of 1 L/min); and OCP - CP with O, 1 hour per day every 3 days/3 sessions. Enamel surface microhardness (Knoop), roughness (Ra), and micromorphology by scanning electron microscopy (5,000x magnification) were determined before and after the treatments. Results: ANOVA and Tukey-Kramer’s test showed that enamel microhardness remained unchanged by treatment with O and OCP (p=0.0087), but decreased by treatment with CP. Treatment with O promoted higher enamel microhardness than the other groups (p=0.0169). Generalized linear mixed models for repeated measures over time indicated treatment with CP increased enamel roughness more than OCP or O (p=0.0003). CP produced slight irregularities in enamel micromorphology after the whitening treatment. O, with or without CP, maintained the mechanical and physical properties of microhardness and enamel surface micromorphology, and either maintained or reduced surface roughness, compared to the conventional tray-delivered CP bleaching treatment. Conclusions: Treatment with 10% carbamide peroxide in trays promoted greater changes in enamel surface properties than treatments with ozone and with 10% ozonized carbamide peroxide in the office.
- 29 April 2023
- Published by Sociedad Argentina de Investigacion Odontologica in Acta Odontológica Latinoamericana
- Vol. 36 (1) , 15-23
Open AccessOzone gas therapy for tooth bleaching preserves enamel microhardness, roughness and surface micromorphology
After ozone therapy for bleaching, it is important to evaluate enamel surface properties, to ensure that bleaching provides adequate conditions for sound dental substrate. Aim: The aim of this in vitro study was to evaluate the effects of a bleaching treatment with 10% carbamide peroxide (CP), with or without ozone (O), on the microhardness, roughness and micromorphology of the enamel surface. Materials and Method: Bovine enamel blocks were planed and distributed among the following three bleaching treatment groups (n=10): CP - 1 hour per day/14 days (Opalescence PF 10%/ Ultradent); O - 1 hour per day every 3 days/3 sessions (Medplus V Philozon, 60 mcg/mL and oxygen flow rate of 1 L/min); and OCP - CP with O, 1 hour per day every 3 days/3 sessions. Enamel surface microhardness (Knoop), roughness (Ra), and micromorphology by scanning electron microscopy (5,000x magnification) were determined before and after the treatments. Results: ANOVA and Tukey-Kramer’s test showed that enamel microhardness remained unchanged by treatment with O and OCP (p=0.0087), but decreased by treatment with CP. Treatment with O promoted higher enamel microhardness than the other groups (p=0.0169). Generalized linear mixed models for repeated measures over time indicated treatment with CP increased enamel roughness more than OCP or O (p=0.0003). CP produced slight irregularities in enamel micromorphology after the whitening treatment. O, with or without CP, maintained the mechanical and physical properties of microhardness and enamel surface micromorphology, and either maintained or reduced surface roughness, compared to the conventional tray-delivered CP bleaching treatment. Conclusions: Treatment with 10% carbamide peroxide in trays promoted greater changes in enamel surface properties than treatments with ozone and with 10% ozonized carbamide peroxide in the office.
- Open Access
- 1 July 2022
- Published by Medknow in Medical Gas Research
- Vol. 12 (3) , 100-106
Color change after tooth bleaching with ozone and 10% ozonized carbamide peroxide for in-office use
There is a constant search for bleaching treatments that can offer greater safety with fewer adverse effects, especially in the techniques performed in the office, which usually employ hydrogen peroxide in high concentrations (35% to 40%) that are not recommended by some international control agencies. This in vitro study evaluated the color change after tooth bleaching with the use of ozone and a 10% ozonized carbamide peroxide bleaching treatment for in-office use. Thirty molars were allocated (n = 10): three applications of ozone (1 hour every 3 days); three applications of 10% ozonized carbamide peroxide (1 hour every 3 days); 10% carbamide peroxide agent (8 hours a day for 7 days). The teeth were mounted on a plaster model to simulate the dental arch, and trays made of silicone were used for the application of the bleaching agents and to allow ozone to enter through. The ozone concentration used was 60 μg/mL, with an oxygen flow of 0.25 L/min. The values of color change showed no significant differences among treatments. The variations in the parameters over time, as well as the values of ΔE ab, ΔE 00, and WI D, showed that there was no significant difference among the three treatments. The use of ozone and 10% ozonized carbamide peroxide for in-office use was effective for tooth bleaching with clinically perceptible and acceptable color alterations. The study was approved on September 10, 2019 by the São Leopoldo Mandic Ethics Research Committee (CAAE No. 17711719.4.0000.5374).
- 1 July 2022
- Published by Medknow in Medical Gas Research
- Vol. 12 (3) , 100-106
Open AccessColor change after tooth bleaching with ozone and 10% ozonized carbamide peroxide for in-office use
There is a constant search for bleaching treatments that can offer greater safety with fewer adverse effects, especially in the techniques performed in the office, which usually employ hydrogen peroxide in high concentrations (35% to 40%) that are not recommended by some international control agencies. This in vitro study evaluated the color change after tooth bleaching with the use of ozone and a 10% ozonized carbamide peroxide bleaching treatment for in-office use. Thirty molars were allocated (n = 10): three applications of ozone (1 hour every 3 days); three applications of 10% ozonized carbamide peroxide (1 hour every 3 days); 10% carbamide peroxide agent (8 hours a day for 7 days). The teeth were mounted on a plaster model to simulate the dental arch, and trays made of silicone were used for the application of the bleaching agents and to allow ozone to enter through. The ozone concentration used was 60 μg/mL, with an oxygen flow of 0.25 L/min. The values of color change showed no significant differences among treatments. The variations in the parameters over time, as well as the values of ΔE ab, ΔE 00, and WI D, showed that there was no significant difference among the three treatments. The use of ozone and 10% ozonized carbamide peroxide for in-office use was effective for tooth bleaching with clinically perceptible and acceptable color alterations. The study was approved on September 10, 2019 by the São Leopoldo Mandic Ethics Research Committee (CAAE No. 17711719.4.0000.5374).