Akiko Yamamoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Akiko Yamamoto has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Koji Fujita
Institute of Science Tokyo, Tokyo, Japan
7 shared publications - Eriku Yamada
Department of Orthopaedic and Spinal Surgery, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
5 shared publications - Kazuya Tsukamoto
Department of Orthopaedic and Spinal Surgery, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
5 shared publications - Takuya Ibara
Institute of Science Tokyo, Tokyo, Japan
5 shared publications - Fumiyuki Nihey
Biometrics Research Labs, NEC Corporation, Hinode 1131, Abiko 270-1198, Chiba, Japan
3 shared publications - Kentaro Nakahara
Biometrics Research Labs, NEC Corporation, Hinode 1131, Abiko 270-1198, Chiba, Japan
3 shared publications
Latest Publications
- 31 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
Wearable Device and Algorithm for Fall Prevention: Monitoring Fall Risk Using Foot Motion Measured by an In-Shoe Motion Sensor
Falls are a significant public health concern worldwide, particularly for older adults. In this study, we aim to create an effective quantitative indicator for long-term daily fall risk assessment, suitable for use with in-shoe motion sensors (IMSs). We used the likelihood of an individual being a faller (ranging from 0 to 1) as a representation of the quantitative fall risk indicator. This indicator was constructed using data from 40 non-fallers and 24 fallers, all female older adults with distal radius fractures caused by falls within six months (denoted as 0 and 1, respectively). The indicator was determined using Fisher’s discriminant, naïve Bayesian, or logistic regression approaches. Predictors were derived from four types of gait parameters and four types of physical ability metrics, all of which can be measured or estimated using IMS-measured gait. To prevent overfitting, we performed principal component analysis on the predictors. To validate our method, we assessed the Pearson’s correlation between clinical experts-rated fall risk scores and the constructed fall risk indicator using a separate group of 19 older female adults. The Pearson’s correlation obtained was 0.766. We successfully developed a fall risk indicator using IMS-measured gait, demonstrating the potential for IMSs to achieve long-term daily fall risk assessment.
- 31 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
Wearable Device and Algorithm for Fall Prevention: Monitoring Fall Risk Using Foot Motion Measured by an In-Shoe Motion Sensor
Falls are a significant public health concern worldwide, particularly for older adults. In this study, we aim to create an effective quantitative indicator for long-term daily fall risk assessment, suitable for use with in-shoe motion sensors (IMSs). We used the likelihood of an individual being a faller (ranging from 0 to 1) as a representation of the quantitative fall risk indicator. This indicator was constructed using data from 40 non-fallers and 24 fallers, all female older adults with distal radius fractures caused by falls within six months (denoted as 0 and 1, respectively). The indicator was determined using Fisher’s discriminant, naïve Bayesian, or logistic regression approaches. Predictors were derived from four types of gait parameters and four types of physical ability metrics, all of which can be measured or estimated using IMS-measured gait. To prevent overfitting, we performed principal component analysis on the predictors. To validate our method, we assessed the Pearson’s correlation between clinical experts-rated fall risk scores and the constructed fall risk indicator using a separate group of 19 older female adults. The Pearson’s correlation obtained was 0.766. We successfully developed a fall risk indicator using IMS-measured gait, demonstrating the potential for IMSs to achieve long-term daily fall risk assessment.
- Open Access
- 20 March 2024
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 12 (1) , e55178
Using In-Shoe Inertial Measurement Unit Sensors to Understand Daily-Life Gait Characteristics in Patients With Distal Radius Fractures During 6 Months of Recovery: Cross-Sectional Study
Background: A distal radius fracture (DRF) is a common initial fragility fracture among women in their early postmenopausal period, which is associated with an increased risk of subsequent fractures. Gait assessments are valuable for evaluating fracture risk; inertial measurement units (IMUs) have been widely used to assess gait under free-living conditions. However, little is known about long-term changes in patients with DRF, especially concerning daily-life gait. We hypothesized that, in the long term, the daily-life gait parameters in patients with DRF could enable us to reveal future risk factors for falls and fractures. Objective: This study assessed the spatiotemporal characteristics of patients with DRF at 4 weeks and 6 months of recovery. Methods: We recruited 16 women in their postmenopausal period with DRF as their first fragility fracture (mean age 62.3, SD 7.0 years) and 28 matched healthy controls (mean age 65.6, SD 8.0 years). Daily-life gait assessments and physical assessments, such as hand grip strength (HGS), were performed using an in-shoe IMU sensor. Participants’ results were compared with those of the control group, and their recovery was assessed for 6 months after the fracture. Results: In the fracture group, at 4 weeks after DRF, lower foot height in the swing phase (P=.049) and higher variability of stride length (P=.03) were observed, which improved gradually. However, the dorsiflexion angle in the fracture group tended to be lower consistently during 6 months (at 4 weeks: P=.06; during 6 months: P=.07). As for the physical assessments, the fracture group showed lower HGS at all time points (at 4 weeks: P<.001; during 6 months: P=.04), despite significant improvement at 6 months (P<.001). Conclusions: With an in-shoe IMU sensor, we discovered the recovery of spatiotemporal gait characteristics 6 months after DRF surgery without the participants’ awareness. The consistently unchanged dorsiflexion angle in the swing phase and lower HGS could be associated with fracture risk, implying the high clinical importance of appropriate interventions for patients with DRF to prevent future fractures. These results could be applied to a screening tool for evaluating the risk of falls and fractures, which may contribute to constructing a new health care system using wearable devices in the near future.
- 20 March 2024
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 12 (1) , e55178
Open AccessUsing In-Shoe Inertial Measurement Unit Sensors to Understand Daily-Life Gait Characteristics in Patients With Distal Radius Fractures During 6 Months of Recovery: Cross-Sectional Study
Background: A distal radius fracture (DRF) is a common initial fragility fracture among women in their early postmenopausal period, which is associated with an increased risk of subsequent fractures. Gait assessments are valuable for evaluating fracture risk; inertial measurement units (IMUs) have been widely used to assess gait under free-living conditions. However, little is known about long-term changes in patients with DRF, especially concerning daily-life gait. We hypothesized that, in the long term, the daily-life gait parameters in patients with DRF could enable us to reveal future risk factors for falls and fractures. Objective: This study assessed the spatiotemporal characteristics of patients with DRF at 4 weeks and 6 months of recovery. Methods: We recruited 16 women in their postmenopausal period with DRF as their first fragility fracture (mean age 62.3, SD 7.0 years) and 28 matched healthy controls (mean age 65.6, SD 8.0 years). Daily-life gait assessments and physical assessments, such as hand grip strength (HGS), were performed using an in-shoe IMU sensor. Participants’ results were compared with those of the control group, and their recovery was assessed for 6 months after the fracture. Results: In the fracture group, at 4 weeks after DRF, lower foot height in the swing phase (P=.049) and higher variability of stride length (P=.03) were observed, which improved gradually. However, the dorsiflexion angle in the fracture group tended to be lower consistently during 6 months (at 4 weeks: P=.06; during 6 months: P=.07). As for the physical assessments, the fracture group showed lower HGS at all time points (at 4 weeks: P<.001; during 6 months: P=.04), despite significant improvement at 6 months (P<.001). Conclusions: With an in-shoe IMU sensor, we discovered the recovery of spatiotemporal gait characteristics 6 months after DRF surgery without the participants’ awareness. The consistently unchanged dorsiflexion angle in the swing phase and lower HGS could be associated with fracture risk, implying the high clinical importance of appropriate interventions for patients with DRF to prevent future fractures. These results could be applied to a screening tool for evaluating the risk of falls and fractures, which may contribute to constructing a new health care system using wearable devices in the near future.
- Open Access
- 5 December 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Using In-Shoe Inertial Measurement Unit Sensors to Understand Daily-Life Gait Characteristics in Patients With Distal Radius Fractures During 6 Months of Recovery: Cross-Sectional Study (Preprint)
BACKGROUND A distal radius fracture (DRF) is a common initial fragility fracture among women in their early postmenopausal period, which is associated with an increased risk of subsequent fractures. Gait assessments are valuable for evaluating fracture risk; inertial measurement units (IMUs) have been widely used to assess gait under free-living conditions. However, little is known about long-term changes in patients with DRF, especially concerning daily-life gait. We hypothesized that, in the long term, the daily-life gait parameters in patients with DRF could enable us to reveal future risk factors for falls and fractures. OBJECTIVE This study assessed the spatiotemporal characteristics of patients with DRF at 4 weeks and 6 months of recovery. METHODS We recruited 16 women in their postmenopausal period with DRF as their first fragility fracture (mean age 62.3, SD 7.0 years) and 28 matched healthy controls (mean age 65.6, SD 8.0 years). Daily-life gait assessments and physical assessments, such as hand grip strength (HGS), were performed using an in-shoe IMU sensor. Participants’ results were compared with those of the control group, and their recovery was assessed for 6 months after the fracture. RESULTS In the fracture group, at 4 weeks after DRF, lower foot height in the swing phase (P=.049) and higher variability of stride length (P=.03) were observed, which improved gradually. However, the dorsiflexion angle in the fracture group tended to be lower consistently during 6 months (at 4 weeks: P=.06; during 6 months: P=.07). As for the physical assessments, the fracture group showed lower HGS at all time points (at 4 weeks: P<.001; during 6 months: P=.04), despite significant improvement at 6 months (P<.001). CONCLUSIONS With an in-shoe IMU sensor, we discovered the recovery of spatiotemporal gait characteristics 6 months after DRF surgery without the participants’ awareness. The consistently unchanged dorsiflexion angle in the swing phase and lower HGS could be associated with fracture risk, implying the high clinical importance of appropriate interventions for patients with DRF to prevent future fractures. These results could be applied to a screening tool for evaluating the risk of falls and fractures, which may contribute to constructing a new health care system using wearable devices in the near future.
- 5 December 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessUsing In-Shoe Inertial Measurement Unit Sensors to Understand Daily-Life Gait Characteristics in Patients With Distal Radius Fractures During 6 Months of Recovery: Cross-Sectional Study (Preprint)
BACKGROUND A distal radius fracture (DRF) is a common initial fragility fracture among women in their early postmenopausal period, which is associated with an increased risk of subsequent fractures. Gait assessments are valuable for evaluating fracture risk; inertial measurement units (IMUs) have been widely used to assess gait under free-living conditions. However, little is known about long-term changes in patients with DRF, especially concerning daily-life gait. We hypothesized that, in the long term, the daily-life gait parameters in patients with DRF could enable us to reveal future risk factors for falls and fractures. OBJECTIVE This study assessed the spatiotemporal characteristics of patients with DRF at 4 weeks and 6 months of recovery. METHODS We recruited 16 women in their postmenopausal period with DRF as their first fragility fracture (mean age 62.3, SD 7.0 years) and 28 matched healthy controls (mean age 65.6, SD 8.0 years). Daily-life gait assessments and physical assessments, such as hand grip strength (HGS), were performed using an in-shoe IMU sensor. Participants’ results were compared with those of the control group, and their recovery was assessed for 6 months after the fracture. RESULTS In the fracture group, at 4 weeks after DRF, lower foot height in the swing phase (P=.049) and higher variability of stride length (P=.03) were observed, which improved gradually. However, the dorsiflexion angle in the fracture group tended to be lower consistently during 6 months (at 4 weeks: P=.06; during 6 months: P=.07). As for the physical assessments, the fracture group showed lower HGS at all time points (at 4 weeks: P<.001; during 6 months: P=.04), despite significant improvement at 6 months (P<.001). CONCLUSIONS With an in-shoe IMU sensor, we discovered the recovery of spatiotemporal gait characteristics 6 months after DRF surgery without the participants’ awareness. The consistently unchanged dorsiflexion angle in the swing phase and lower HGS could be associated with fracture risk, implying the high clinical importance of appropriate interventions for patients with DRF to prevent future fractures. These results could be applied to a screening tool for evaluating the risk of falls and fractures, which may contribute to constructing a new health care system using wearable devices in the near future.
- Top Cited PapersOpen Access
- 15 September 2023
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 25 (1) , e47621
The Potential of ChatGPT as a Self-Diagnostic Tool in Common Orthopedic Diseases: Exploratory Study
Background: Artificial intelligence (AI) has gained tremendous popularity recently, especially the use of natural language processing (NLP). ChatGPT is a state-of-the-art chatbot capable of creating natural conversations using NLP. The use of AI in medicine can have a tremendous impact on health care delivery. Although some studies have evaluated ChatGPT’s accuracy in self-diagnosis, there is no research regarding its precision and the degree to which it recommends medical consultations. Objective: The aim of this study was to evaluate ChatGPT’s ability to accurately and precisely self-diagnose common orthopedic diseases, as well as the degree of recommendation it provides for medical consultations. Methods: Over a 5-day course, each of the study authors submitted the same questions to ChatGPT. The conditions evaluated were carpal tunnel syndrome (CTS), cervical myelopathy (CM), lumbar spinal stenosis (LSS), knee osteoarthritis (KOA), and hip osteoarthritis (HOA). Answers were categorized as either correct, partially correct, incorrect, or a differential diagnosis. The percentage of correct answers and reproducibility were calculated. The reproducibility between days and raters were calculated using the Fleiss κ coefficient. Answers that recommended that the patient seek medical attention were recategorized according to the strength of the recommendation as defined by the study. Results: The ratios of correct answers were 25/25, 1/25, 24/25, 16/25, and 17/25 for CTS, CM, LSS, KOA, and HOA, respectively. The ratios of incorrect answers were 23/25 for CM and 0/25 for all other conditions. The reproducibility between days was 1.0, 0.15, 0.7, 0.6, and 0.6 for CTS, CM, LSS, KOA, and HOA, respectively. The reproducibility between raters was 1.0, 0.1, 0.64, –0.12, and 0.04 for CTS, CM, LSS, KOA, and HOA, respectively. Among the answers recommending medical attention, the phrases “essential,” “recommended,” “best,” and “important” were used. Specifically, “essential” occurred in 4 out of 125, “recommended” in 12 out of 125, “best” in 6 out of 125, and “important” in 94 out of 125 answers. Additionally, 7 out of the 125 answers did not include a recommendation to seek medical attention. Conclusions: The accuracy and reproducibility of ChatGPT to self-diagnose five common orthopedic conditions were inconsistent. The accuracy could potentially be improved by adding symptoms that could easily identify a specific location. Only a few answers were accompanied by a strong recommendation to seek medical attention according to our study standards. Although ChatGPT could serve as a potential first step in accessing care, we found variability in accurate self-diagnosis. Given the risk of harm with self-diagnosis without medical follow-up, it would be prudent for an NLP to include clear language alerting patients to seek expert medical opinions. We hope to shed further light on the use of AI in a future clinical study.
- 15 September 2023
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 25 (1) , e47621
Top Cited PapersOpen AccessThe Potential of ChatGPT as a Self-Diagnostic Tool in Common Orthopedic Diseases: Exploratory Study
Background: Artificial intelligence (AI) has gained tremendous popularity recently, especially the use of natural language processing (NLP). ChatGPT is a state-of-the-art chatbot capable of creating natural conversations using NLP. The use of AI in medicine can have a tremendous impact on health care delivery. Although some studies have evaluated ChatGPT’s accuracy in self-diagnosis, there is no research regarding its precision and the degree to which it recommends medical consultations. Objective: The aim of this study was to evaluate ChatGPT’s ability to accurately and precisely self-diagnose common orthopedic diseases, as well as the degree of recommendation it provides for medical consultations. Methods: Over a 5-day course, each of the study authors submitted the same questions to ChatGPT. The conditions evaluated were carpal tunnel syndrome (CTS), cervical myelopathy (CM), lumbar spinal stenosis (LSS), knee osteoarthritis (KOA), and hip osteoarthritis (HOA). Answers were categorized as either correct, partially correct, incorrect, or a differential diagnosis. The percentage of correct answers and reproducibility were calculated. The reproducibility between days and raters were calculated using the Fleiss κ coefficient. Answers that recommended that the patient seek medical attention were recategorized according to the strength of the recommendation as defined by the study. Results: The ratios of correct answers were 25/25, 1/25, 24/25, 16/25, and 17/25 for CTS, CM, LSS, KOA, and HOA, respectively. The ratios of incorrect answers were 23/25 for CM and 0/25 for all other conditions. The reproducibility between days was 1.0, 0.15, 0.7, 0.6, and 0.6 for CTS, CM, LSS, KOA, and HOA, respectively. The reproducibility between raters was 1.0, 0.1, 0.64, –0.12, and 0.04 for CTS, CM, LSS, KOA, and HOA, respectively. Among the answers recommending medical attention, the phrases “essential,” “recommended,” “best,” and “important” were used. Specifically, “essential” occurred in 4 out of 125, “recommended” in 12 out of 125, “best” in 6 out of 125, and “important” in 94 out of 125 answers. Additionally, 7 out of the 125 answers did not include a recommendation to seek medical attention. Conclusions: The accuracy and reproducibility of ChatGPT to self-diagnose five common orthopedic conditions were inconsistent. The accuracy could potentially be improved by adding symptoms that could easily identify a specific location. Only a few answers were accompanied by a strong recommendation to seek medical attention according to our study standards. Although ChatGPT could serve as a potential first step in accessing care, we found variability in accurate self-diagnosis. Given the risk of harm with self-diagnosis without medical follow-up, it would be prudent for an NLP to include clear language alerting patients to seek expert medical opinions. We hope to shed further light on the use of AI in a future clinical study.
- Open Access
- 27 March 2023
- Published by JMIR Publications Inc. in JMIR Preprints
The Potential of ChatGPT as a Self-Diagnostic Tool in Common Orthopedic Diseases: Exploratory Study (Preprint)
BACKGROUND Artificial intelligence (AI) has gained tremendous popularity recently, especially the use of natural language processing (NLP). ChatGPT is a state-of-the-art chatbot capable of creating natural conversations using NLP. The use of AI in medicine can have a tremendous impact on health care delivery. Although some studies have evaluated ChatGPT’s accuracy in self-diagnosis, there is no research regarding its precision and the degree to which it recommends medical consultations. OBJECTIVE The aim of this study was to evaluate ChatGPT’s ability to accurately and precisely self-diagnose common orthopedic diseases, as well as the degree of recommendation it provides for medical consultations. METHODS Over a 5-day course, each of the study authors submitted the same questions to ChatGPT. The conditions evaluated were carpal tunnel syndrome (CTS), cervical myelopathy (CM), lumbar spinal stenosis (LSS), knee osteoarthritis (KOA), and hip osteoarthritis (HOA). Answers were categorized as either correct, partially correct, incorrect, or a differential diagnosis. The percentage of correct answers and reproducibility were calculated. The reproducibility between days and raters were calculated using the Fleiss κ coefficient. Answers that recommended that the patient seek medical attention were recategorized according to the strength of the recommendation as defined by the study. RESULTS The ratios of correct answers were 25/25, 1/25, 24/25, 16/25, and 17/25 for CTS, CM, LSS, KOA, and HOA, respectively. The ratios of incorrect answers were 23/25 for CM and 0/25 for all other conditions. The reproducibility between days was 1.0, 0.15, 0.7, 0.6, and 0.6 for CTS, CM, LSS, KOA, and HOA, respectively. The reproducibility between raters was 1.0, 0.1, 0.64, –0.12, and 0.04 for CTS, CM, LSS, KOA, and HOA, respectively. Among the answers recommending medical attention, the phrases “essential,” “recommended,” “best,” and “important” were used. Specifically, “essential” occurred in 4 out of 125, “recommended” in 12 out of 125, “best” in 6 out of 125, and “important” in 94 out of 125 answers. Additionally, 7 out of the 125 answers did not include a recommendation to seek medical attention. CONCLUSIONS The accuracy and reproducibility of ChatGPT to self-diagnose five common orthopedic conditions were inconsistent. The accuracy could potentially be improved by adding symptoms that could easily identify a specific location. Only a few answers were accompanied by a strong recommendation to seek medical attention according to our study standards. Although ChatGPT could serve as a potential first step in accessing care, we found variability in accurate self-diagnosis. Given the risk of harm with self-diagnosis without medical follow-up, it would be prudent for an NLP to include clear language alerting patients to seek expert medical opinions. We hope to shed further light on the use of AI in a future clinical study.
- 27 March 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessThe Potential of ChatGPT as a Self-Diagnostic Tool in Common Orthopedic Diseases: Exploratory Study (Preprint)
BACKGROUND Artificial intelligence (AI) has gained tremendous popularity recently, especially the use of natural language processing (NLP). ChatGPT is a state-of-the-art chatbot capable of creating natural conversations using NLP. The use of AI in medicine can have a tremendous impact on health care delivery. Although some studies have evaluated ChatGPT’s accuracy in self-diagnosis, there is no research regarding its precision and the degree to which it recommends medical consultations. OBJECTIVE The aim of this study was to evaluate ChatGPT’s ability to accurately and precisely self-diagnose common orthopedic diseases, as well as the degree of recommendation it provides for medical consultations. METHODS Over a 5-day course, each of the study authors submitted the same questions to ChatGPT. The conditions evaluated were carpal tunnel syndrome (CTS), cervical myelopathy (CM), lumbar spinal stenosis (LSS), knee osteoarthritis (KOA), and hip osteoarthritis (HOA). Answers were categorized as either correct, partially correct, incorrect, or a differential diagnosis. The percentage of correct answers and reproducibility were calculated. The reproducibility between days and raters were calculated using the Fleiss κ coefficient. Answers that recommended that the patient seek medical attention were recategorized according to the strength of the recommendation as defined by the study. RESULTS The ratios of correct answers were 25/25, 1/25, 24/25, 16/25, and 17/25 for CTS, CM, LSS, KOA, and HOA, respectively. The ratios of incorrect answers were 23/25 for CM and 0/25 for all other conditions. The reproducibility between days was 1.0, 0.15, 0.7, 0.6, and 0.6 for CTS, CM, LSS, KOA, and HOA, respectively. The reproducibility between raters was 1.0, 0.1, 0.64, –0.12, and 0.04 for CTS, CM, LSS, KOA, and HOA, respectively. Among the answers recommending medical attention, the phrases “essential,” “recommended,” “best,” and “important” were used. Specifically, “essential” occurred in 4 out of 125, “recommended” in 12 out of 125, “best” in 6 out of 125, and “important” in 94 out of 125 answers. Additionally, 7 out of the 125 answers did not include a recommendation to seek medical attention. CONCLUSIONS The accuracy and reproducibility of ChatGPT to self-diagnose five common orthopedic conditions were inconsistent. The accuracy could potentially be improved by adding symptoms that could easily identify a specific location. Only a few answers were accompanied by a strong recommendation to seek medical attention according to our study standards. Although ChatGPT could serve as a potential first step in accessing care, we found variability in accurate self-diagnosis. Given the risk of harm with self-diagnosis without medical follow-up, it would be prudent for an NLP to include clear language alerting patients to seek expert medical opinions. We hope to shed further light on the use of AI in a future clinical study.
- Open Access
- 1 January 2023
- Published by SAGE Publications in Digital Health
- Vol. 9
Screening for degenerative cervical myelopathy with the 10-second grip-and-release test using a smartphone and machine learning: A pilot study
Objective: Early detection and intervention are essential for the mitigation of degenerative cervical myelopathy (DCM). However, although several screening methods exist, they are difficult to understand for community-dwelling people, and the equipment required to set up the test environment is expensive. This study investigated the viability of a DCM-screening method based on the 10-second grip-and-release test using a machine learning algorithm and a smartphone equipped with a camera to facilitate a simple screening system. Methods: Twenty-two participants comprising a group of DCM patients and 17 comprising a control group participated in this study. A spine surgeon diagnosed the presence of DCM. Patients performing the 10-second grip-and-release test were filmed, and the videos were analyzed. The probability of the presence of DCM was estimated using a support vector machine algorithm, and sensitivity, specificity, and area under the curve (AUC) were calculated. Two assessments of the correlation between estimated scores were conducted. The first used a random forest regression model and the Japanese Orthopaedic Association scores for cervical myelopathy (C-JOA). The second assessment used a different model, random forest regression, and the Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire. Results: The final classification model had a sensitivity of 90.9%, specificity of 88.2%, and AUC of 0.93. The correlations between each estimated score and the C-JOA and DASH scores were 0.79 and 0.67, respectively. Conclusions: The proposed model could be a helpful screening tool for DCM as it showed excellent performance and high usability for community-dwelling people and non-spine surgeons.
- 1 January 2023
- Published by SAGE Publications in Digital Health
- Vol. 9
Open AccessScreening for degenerative cervical myelopathy with the 10-second grip-and-release test using a smartphone and machine learning: A pilot study
Objective: Early detection and intervention are essential for the mitigation of degenerative cervical myelopathy (DCM). However, although several screening methods exist, they are difficult to understand for community-dwelling people, and the equipment required to set up the test environment is expensive. This study investigated the viability of a DCM-screening method based on the 10-second grip-and-release test using a machine learning algorithm and a smartphone equipped with a camera to facilitate a simple screening system. Methods: Twenty-two participants comprising a group of DCM patients and 17 comprising a control group participated in this study. A spine surgeon diagnosed the presence of DCM. Patients performing the 10-second grip-and-release test were filmed, and the videos were analyzed. The probability of the presence of DCM was estimated using a support vector machine algorithm, and sensitivity, specificity, and area under the curve (AUC) were calculated. Two assessments of the correlation between estimated scores were conducted. The first used a random forest regression model and the Japanese Orthopaedic Association scores for cervical myelopathy (C-JOA). The second assessment used a different model, random forest regression, and the Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire. Results: The final classification model had a sensitivity of 90.9%, specificity of 88.2%, and AUC of 0.93. The correlations between each estimated score and the C-JOA and DASH scores were 0.79 and 0.67, respectively. Conclusions: The proposed model could be a helpful screening tool for DCM as it showed excellent performance and high usability for community-dwelling people and non-spine surgeons.
- Open Access
- 3 October 2022
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 7 (2) , e41327
High-Dimensional Analysis of Finger Motion and Screening of Cervical Myelopathy With a Noncontact Sensor: Diagnostic Case-Control Study
Background: Cervical myelopathy (CM) causes several symptoms such as clumsiness of the hands and often requires surgery. Screening and early diagnosis of CM are important because some patients are unaware of their early symptoms and consult a surgeon only after their condition has become severe. The 10-second hand grip and release test is commonly used to check for the presence of CM. The test is simple but would be more useful for screening if it could objectively evaluate the changes in movement specific to CM. A previous study analyzed finger movements in the 10-second hand grip and release test using the Leap Motion, a noncontact sensor, and a system was developed that can diagnose CM with high sensitivity and specificity using machine learning. However, the previous study had limitations in that the system recorded few parameters and did not differentiate CM from other hand disorders. Objective: This study aims to develop a system that can diagnose CM with higher sensitivity and specificity, and distinguish CM from carpal tunnel syndrome (CTS), a common hand disorder. We then validated the system with a modified Leap Motion that can record the joints of each finger. Methods: In total, 31, 27, and 29 participants were recruited into the CM, CTS, and control groups, respectively. We developed a system using Leap Motion that recorded 229 parameters of finger movements while participants gripped and released their fingers as rapidly as possible. A support vector machine was used for machine learning to develop the binary classification model and calculated the sensitivity, specificity, and area under the curve (AUC). We developed two models, one to diagnose CM among the CM and control groups (CM/control model), and the other to diagnose CM among the CM and non-CM groups (CM/non-CM model). Results: The CM/control model indexes were as follows: sensitivity 74.2%, specificity 89.7%, and AUC 0.82. The CM/non-CM model indexes were as follows: sensitivity 71%, specificity 72.87%, and AUC 0.74. Conclusions: We developed a screening system capable of diagnosing CM with higher sensitivity and specificity. This system can differentiate patients with CM from patients with CTS as well as healthy patients and has the potential to screen for CM in a variety of patients.
- 3 October 2022
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 7 (2) , e41327
Open AccessHigh-Dimensional Analysis of Finger Motion and Screening of Cervical Myelopathy With a Noncontact Sensor: Diagnostic Case-Control Study
Background: Cervical myelopathy (CM) causes several symptoms such as clumsiness of the hands and often requires surgery. Screening and early diagnosis of CM are important because some patients are unaware of their early symptoms and consult a surgeon only after their condition has become severe. The 10-second hand grip and release test is commonly used to check for the presence of CM. The test is simple but would be more useful for screening if it could objectively evaluate the changes in movement specific to CM. A previous study analyzed finger movements in the 10-second hand grip and release test using the Leap Motion, a noncontact sensor, and a system was developed that can diagnose CM with high sensitivity and specificity using machine learning. However, the previous study had limitations in that the system recorded few parameters and did not differentiate CM from other hand disorders. Objective: This study aims to develop a system that can diagnose CM with higher sensitivity and specificity, and distinguish CM from carpal tunnel syndrome (CTS), a common hand disorder. We then validated the system with a modified Leap Motion that can record the joints of each finger. Methods: In total, 31, 27, and 29 participants were recruited into the CM, CTS, and control groups, respectively. We developed a system using Leap Motion that recorded 229 parameters of finger movements while participants gripped and released their fingers as rapidly as possible. A support vector machine was used for machine learning to develop the binary classification model and calculated the sensitivity, specificity, and area under the curve (AUC). We developed two models, one to diagnose CM among the CM and control groups (CM/control model), and the other to diagnose CM among the CM and non-CM groups (CM/non-CM model). Results: The CM/control model indexes were as follows: sensitivity 74.2%, specificity 89.7%, and AUC 0.82. The CM/non-CM model indexes were as follows: sensitivity 71%, specificity 72.87%, and AUC 0.74. Conclusions: We developed a screening system capable of diagnosing CM with higher sensitivity and specificity. This system can differentiate patients with CM from patients with CTS as well as healthy patients and has the potential to screen for CM in a variety of patients.