Jianwei Shao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jianwei Shao has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Junhua Wang
Hubei Key Laboratory of Power Equipment and System Security for Integrated Energy, School of Electrical Engineering and Automation, Wuhan University, Wuhan, China
8 shared publications - Changsong Cai
Hubei Key Laboratory of Power Equipment and System Security for Integrated Energy, School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
3 shared publications Junhua Wang
3 shared publications- Zhanxiang Jin
Hubei Key Laboratory of Power Equipment and System Security for Integrated Energy, School of Electrical Engineering and Automation, Wuhan University, Wuhan, China
3 shared publications - Ziqing Wang
Hubei Key Laboratory of Power Equipment and System Security for Integrated Energy, School of Electrical Engineering and Automation, Wuhan University, Wuhan, China
3 shared publications - Chao Wang
Future Technology School, Shenzhen Technology University, Shenzhen 518118, China
2 shared publications
Latest Publications
- 30 April 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 259
Optimal scheduling framework for hydro-photovoltaic-storage-EV systems with multi-timescale uncertainty coordination
- 30 April 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 259
Optimal scheduling framework for hydro-photovoltaic-storage-EV systems with multi-timescale uncertainty coordination
- 15 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Laser Scattering Measurement of AC Electric Field-Induced Dynamic Characteristics of Transformer Oil-Water Interfaces
The synergistic effect of AC electric fields and moisture in transformer oil causes insulation degradation, but quantitative methods for dynamic oil-water interfaces remain lacking. This research uses colloid chemistry theory modeling, molecular dynamics simulation, and laser scattering technologies to study the microstructural development of the transformer oil-water interface under an AC electric field. It establishes a quantitative relationship between the grayscale value of the Tyndall Effect, electric field strength, and moisture content, as well as an analysis of the oil expansion phenomenon in high-moisture oil samples caused by high electric fields and the coupling of oil flow fluctuations and localized glow phenomenon. Simulations reveal that an AC electric field can increase the diffusion depth of the water phase and cause uneven thickening of the transition layer. Experimental results reveal that within the range of 0-6 kV, the grayscale value exhibits a linear correlation with the electric field strength. Furthermore, the higher the moisture content, the more electric field-induced scattering occurs. For the first time, the electric field-induced oil swelling lens effect is observed, where localized glow phenomenon migrates with oil flow. The proposed non-intrusive method surpasses traditional techniques, enabling real-time monitoring of interface dynamics for transformer insulation assessment.
- 15 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Laser Scattering Measurement of AC Electric Field-Induced Dynamic Characteristics of Transformer Oil-Water Interfaces
The synergistic effect of AC electric fields and moisture in transformer oil causes insulation degradation, but quantitative methods for dynamic oil-water interfaces remain lacking. This research uses colloid chemistry theory modeling, molecular dynamics simulation, and laser scattering technologies to study the microstructural development of the transformer oil-water interface under an AC electric field. It establishes a quantitative relationship between the grayscale value of the Tyndall Effect, electric field strength, and moisture content, as well as an analysis of the oil expansion phenomenon in high-moisture oil samples caused by high electric fields and the coupling of oil flow fluctuations and localized glow phenomenon. Simulations reveal that an AC electric field can increase the diffusion depth of the water phase and cause uneven thickening of the transition layer. Experimental results reveal that within the range of 0-6 kV, the grayscale value exhibits a linear correlation with the electric field strength. Furthermore, the higher the moisture content, the more electric field-induced scattering occurs. For the first time, the electric field-induced oil swelling lens effect is observed, where localized glow phenomenon migrates with oil flow. The proposed non-intrusive method surpasses traditional techniques, enabling real-time monitoring of interface dynamics for transformer insulation assessment.
- 19 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (5) , 2703-2713
In Situ Gas Sensor of Dissolved Acetylene in Transformer Oil Based on Hollow-Core Photonic Bandgap Fiber
Real-time monitoring of the concentration of characteristic gases can therefore detect abnormal operating conditions of a transformer. This paper proposes an in-situ acetylene detection system based on hollow-core photonic bandgap fibers (HC-PBF) and membrane extraction. Simultaneous oil-gas separation and gas detection are achieved using a double-sided rectangular PTFE gas cell and 5-cm-long hollow core fiber Fabry-Perot interferometers (FPI). The FPI fiber probe exhibits a contrast of 7.06dB. And the saturation equilibrium time for oil-gas separation is 0.8h at 80°C. Furthermore, the in-situ detection system exhibits a linear response to acetylene, with a response coefficient of approximately 0.06916μV/ppm and a high degree of linearity (goodness of fit=0.9951). Moreover, 60s is the optimal averaging time, at which time the noise standard deviation is measured at 0.069V and the detection limit is tested to be 0.973ppm. The sensor, with its compact size, high sensitivity, and lack of power supply, enables in-situ detection in oil and presents a novel approach for online monitoring of dissolved gases in transformer oil.
- 19 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (5) , 2703-2713
In Situ Gas Sensor of Dissolved Acetylene in Transformer Oil Based on Hollow-Core Photonic Bandgap Fiber
Real-time monitoring of the concentration of characteristic gases can therefore detect abnormal operating conditions of a transformer. This paper proposes an in-situ acetylene detection system based on hollow-core photonic bandgap fibers (HC-PBF) and membrane extraction. Simultaneous oil-gas separation and gas detection are achieved using a double-sided rectangular PTFE gas cell and 5-cm-long hollow core fiber Fabry-Perot interferometers (FPI). The FPI fiber probe exhibits a contrast of 7.06dB. And the saturation equilibrium time for oil-gas separation is 0.8h at 80°C. Furthermore, the in-situ detection system exhibits a linear response to acetylene, with a response coefficient of approximately 0.06916μV/ppm and a high degree of linearity (goodness of fit=0.9951). Moreover, 60s is the optimal averaging time, at which time the noise standard deviation is measured at 0.069V and the detection limit is tested to be 0.973ppm. The sensor, with its compact size, high sensitivity, and lack of power supply, enables in-situ detection in oil and presents a novel approach for online monitoring of dissolved gases in transformer oil.
- 14 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
Fault Diagnosis of Power Transformer Using Data Enhancement–Input Feature Preference Learning Framework
This proposes a learning framework for transformer fault diagnosis using a convolutional neural network (CNN), with data enhancement and input feature preference. The conditional variational autoencoder (CVAE) model is used to expand each category of samples. The binary encoded genetic algorithm (BEGA) is utilized to optimize the input features, while the diagnostic effectiveness of combinations containing different input features is evaluated using CNN fault diagnosis algorithms. The diagnosis results are comprehensively evaluated using a confusion matrix and multiple indicators. The test results indicate that the proposed data enhancement approach effectively addresses misclassification for minority samples, enhancing fault diagnosis accuracy. The accuracy and recall rate of diagnosing small sample fault types improved by 11.9% and 23.6%, respectively, compared to the fault diagnosis results before sample enhancement. In addition, the learning framework achieved higher diagnostic accuracy with nine preferred input features. Comparing the gas concentration features and initial gas features, the diagnostic accuracy of the preferred input features increased by 4.90% and 3.29%, respectively. This learning framework is applicable to sample imbalances and is somewhat extensible.
- 14 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
Fault Diagnosis of Power Transformer Using Data Enhancement–Input Feature Preference Learning Framework
This proposes a learning framework for transformer fault diagnosis using a convolutional neural network (CNN), with data enhancement and input feature preference. The conditional variational autoencoder (CVAE) model is used to expand each category of samples. The binary encoded genetic algorithm (BEGA) is utilized to optimize the input features, while the diagnostic effectiveness of combinations containing different input features is evaluated using CNN fault diagnosis algorithms. The diagnosis results are comprehensively evaluated using a confusion matrix and multiple indicators. The test results indicate that the proposed data enhancement approach effectively addresses misclassification for minority samples, enhancing fault diagnosis accuracy. The accuracy and recall rate of diagnosing small sample fault types improved by 11.9% and 23.6%, respectively, compared to the fault diagnosis results before sample enhancement. In addition, the learning framework achieved higher diagnostic accuracy with nine preferred input features. Comparing the gas concentration features and initial gas features, the diagnostic accuracy of the preferred input features increased by 4.90% and 3.29%, respectively. This learning framework is applicable to sample imbalances and is somewhat extensible.
- 21 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 21 (2) , 1339-1348
Probabilistic Modeling of Dissolved Gas Concentration for Predicting Operating Status of Oil-Immersed Transformers
Accurate prediction of dissolved gas concentration is vital for status assessment and fault diagnosis in oil-immersed transformers. Most current methods for predicting dissolved gas concentration produce deterministic results without providing any information on prediction uncertainty. This study presents for the first time a prediction model based on probability density, which integrates with interval estimation to assess the operating status of transformers. First, the quantile regression-long short term memory networks-Kernel density estimation model is developed to predict dissolved gas concentration and calculate the corresponding probability density function. The assessment of transformer status is then conducted using interval estimation, which includes a decision base consisting of prediction interval, attention value, and interval width. Experimental results illustrate that the proposed model achieves accurate predictions of gas concentration and probability density with excellent stability and applicability under various operating conditions, achieving the highest accuracy. Additionally, the findings reveal that the false alarm rate of the suggested criterion driven by uncertain information is 5.3% during normal operations and 0% under defective conditions. This article makes a contribution to the field by investigating uncertainty prediction models as valuable tools for predicting dissolved gas concentration and evaluating the condition of transformers.
- 21 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 21 (2) , 1339-1348
Probabilistic Modeling of Dissolved Gas Concentration for Predicting Operating Status of Oil-Immersed Transformers
Accurate prediction of dissolved gas concentration is vital for status assessment and fault diagnosis in oil-immersed transformers. Most current methods for predicting dissolved gas concentration produce deterministic results without providing any information on prediction uncertainty. This study presents for the first time a prediction model based on probability density, which integrates with interval estimation to assess the operating status of transformers. First, the quantile regression-long short term memory networks-Kernel density estimation model is developed to predict dissolved gas concentration and calculate the corresponding probability density function. The assessment of transformer status is then conducted using interval estimation, which includes a decision base consisting of prediction interval, attention value, and interval width. Experimental results illustrate that the proposed model achieves accurate predictions of gas concentration and probability density with excellent stability and applicability under various operating conditions, achieving the highest accuracy. Additionally, the findings reveal that the false alarm rate of the suggested criterion driven by uncertain information is 5.3% during normal operations and 0% under defective conditions. This article makes a contribution to the field by investigating uncertainty prediction models as valuable tools for predicting dissolved gas concentration and evaluating the condition of transformers.
- 6 September 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 237
A Stackelberg game theory-based optimal scheduling of active distribution system considering multi-stakeholders
- 6 September 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 237
A Stackelberg game theory-based optimal scheduling of active distribution system considering multi-stakeholders
- 25 August 2024
- Published by Wiley in International Journal of Circuit Theory and Applications
Misalignment‐tolerant coupling cell of 2‐D modular WPT system for charging area simplified extension
2‐D modular wireless power transfer (WPT) system needs to have stable output when coil misalignment occurs. In order to improve the misalignment tolerance of the system coupling unit, this article proposes a magnetic coupling structure based on the LCC‐S compensation topology by combining a rectangular coil with two sets of mutually orthogonal solenoidal compensation coils. The rectangular coil is used to receive the vertical magnetic flux, and the two sets of compensating coils are used to receive the magnetic flux in the directions of X‐axis and Y‐axis on the horizontal plane, separately. The receiving side of the 2‐D wireless power transmission array cells cascaded half‐bridge rectifiers to connect each group of coils. This arrangement effectively compensates for the voltage drop of the rectangular coil caused by positional offset in any direction, so that the output voltage of the receiving side remains stable. The article firstly establishes the equivalent circuit model of the proposed design and deduces in detail the relationship equations between the output characteristics of the system and each influence factor. Secondly, the magnetic coupling structure is designed by finite element electromagnetic simulation software, and the total equivalent mutual inductance fluctuation of the proposed design is verified to be within 3.9% over the range of 2‐D transmission array cells. Finally, a 150 W experimental platform is built to verify the misaligment‐tolerant of the proposed design in the range of 2‐D transmission array cells. The experimental results show that the output voltage fluctuation of the proposed design within 4.27% at all directional offsets. Moreover, the stable output performance can be obtained in the case of vertical and rotational misalignment.
- 25 August 2024
- Published by Wiley in International Journal of Circuit Theory and Applications
Misalignment‐tolerant coupling cell of 2‐D modular WPT system for charging area simplified extension
2‐D modular wireless power transfer (WPT) system needs to have stable output when coil misalignment occurs. In order to improve the misalignment tolerance of the system coupling unit, this article proposes a magnetic coupling structure based on the LCC‐S compensation topology by combining a rectangular coil with two sets of mutually orthogonal solenoidal compensation coils. The rectangular coil is used to receive the vertical magnetic flux, and the two sets of compensating coils are used to receive the magnetic flux in the directions of X‐axis and Y‐axis on the horizontal plane, separately. The receiving side of the 2‐D wireless power transmission array cells cascaded half‐bridge rectifiers to connect each group of coils. This arrangement effectively compensates for the voltage drop of the rectangular coil caused by positional offset in any direction, so that the output voltage of the receiving side remains stable. The article firstly establishes the equivalent circuit model of the proposed design and deduces in detail the relationship equations between the output characteristics of the system and each influence factor. Secondly, the magnetic coupling structure is designed by finite element electromagnetic simulation software, and the total equivalent mutual inductance fluctuation of the proposed design is verified to be within 3.9% over the range of 2‐D transmission array cells. Finally, a 150 W experimental platform is built to verify the misaligment‐tolerant of the proposed design in the range of 2‐D transmission array cells. The experimental results show that the output voltage fluctuation of the proposed design within 4.27% at all directional offsets. Moreover, the stable output performance can be obtained in the case of vertical and rotational misalignment.
- 1 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-4
Optical Fiber Composite Winding for In Situ Thermal Monitoring of Transmitter Magnetic Mechanism in Long-Track DWPT Systems
Thermal monitoring of the long-track transmitter (Tx) magnetic mechanism of an industrial dynamic wireless power transfer (DWPT) system is necessary for its reliable operation. This paper proposes an optical fiber composite winding (OFCW) for in-situ thermal monitoring of the long-track Tx mechanism. Multichannel optical fibers are compounded on the Tx winding wire, which forms a composite structure, to detect the internal thermal distribution of the whole long-track Tx with fast response and high spatial resolution. A simplified optimization method based on magnetic and temperature field distribution characteristics is then studied to obtain a specific OFCW layout for rapid hotspot measurement and application extensions. Finally, an OFCW-based scaled-down DWPT prototype is established, and the experimental results with accurate thermal monitoring under different operating states confirm the feasibility and effectiveness of the OFCW.
- 1 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-4
Optical Fiber Composite Winding for In Situ Thermal Monitoring of Transmitter Magnetic Mechanism in Long-Track DWPT Systems
Thermal monitoring of the long-track transmitter (Tx) magnetic mechanism of an industrial dynamic wireless power transfer (DWPT) system is necessary for its reliable operation. This paper proposes an optical fiber composite winding (OFCW) for in-situ thermal monitoring of the long-track Tx mechanism. Multichannel optical fibers are compounded on the Tx winding wire, which forms a composite structure, to detect the internal thermal distribution of the whole long-track Tx with fast response and high spatial resolution. A simplified optimization method based on magnetic and temperature field distribution characteristics is then studied to obtain a specific OFCW layout for rapid hotspot measurement and application extensions. Finally, an OFCW-based scaled-down DWPT prototype is established, and the experimental results with accurate thermal monitoring under different operating states confirm the feasibility and effectiveness of the OFCW.