Rubén Pascual
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rubén Pascual has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Carlos Antonio Platero
Automatic Electric and Electronic Engineering and Industrial Computing Department, Universidad Politcnica de Madrid, Madrid, Spain
6 shared publications - Jose Manuel Guerrero
Department of Electrical Engineering, Escuela de Ingeniería de Bilbao, Universidad del País Vasco, 48013 Bilbao, Spain
4 shared publications - Kumar Mahtani
Universidad Politécnica de Madrid
4 shared publications - Marcos Esteban Sánchez
Grid Code Department, Acciona Energia, 28033 Madrid, Spain
2 shared publications - David Talavera
Escuela Tecnica Superior de Ingenieros Industriales
1 shared publication - Eduardo Rivero
ESELEC, Madrid, Spain
1 shared publication
Latest Publications
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Industry Applications Magazine
- Vol. 32 (5) , 66-77
Mitigating the Inrush Current of Power Transformers: Downsize and Optimal Design of Premagnetization Transformers
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Industry Applications Magazine
- Vol. 32 (5) , 66-77
Mitigating the Inrush Current of Power Transformers: Downsize and Optimal Design of Premagnetization Transformers
- Open Access
Recurrent Neuronal Networks for the Prediction of the Temperature of a Synchronous Machine During Its Operation
This work presents the development of an adaptive thermal protection system for synchronous machines (SMs), taking into consideration the final cooling temperature and the operation point of the machine. This system aims to improve current thermal protections, which consist of a fixed alarm and trip thresholds regardless of the generator’s operating point or ambient temperature. A recurrent neural network (RNN)-based approach has been employed to predict SM temperatures during operation. Multiple tests have been conducted on a specially designed test bench. Inside the windings and iron core of the 5.5 kVA generator, multiple Pt100 sensors have been installed to train the neural network with real temperature values, enabling accurate predictions. The selected RNN model is Long Short-Term Memory (LSTM). Its inputs include electrical variables and the inlet and outlet air temperatures of the SM’s cooling system. The results show that the model accurately defines warning and trip thresholds, significantly improving thermal protection, as these thresholds are no longer fixed values. Additionally, the study suggests validating the model under cooling system failures and exploring its application in water-cooled systems. This research is supported by a patent on real-time thermal diagnostics for synchronous machines, highlighting its potential contribution to predictive maintenance and the monitoring of power generation systems.
Open AccessRecurrent Neuronal Networks for the Prediction of the Temperature of a Synchronous Machine During Its Operation
This work presents the development of an adaptive thermal protection system for synchronous machines (SMs), taking into consideration the final cooling temperature and the operation point of the machine. This system aims to improve current thermal protections, which consist of a fixed alarm and trip thresholds regardless of the generator’s operating point or ambient temperature. A recurrent neural network (RNN)-based approach has been employed to predict SM temperatures during operation. Multiple tests have been conducted on a specially designed test bench. Inside the windings and iron core of the 5.5 kVA generator, multiple Pt100 sensors have been installed to train the neural network with real temperature values, enabling accurate predictions. The selected RNN model is Long Short-Term Memory (LSTM). Its inputs include electrical variables and the inlet and outlet air temperatures of the SM’s cooling system. The results show that the model accurately defines warning and trip thresholds, significantly improving thermal protection, as these thresholds are no longer fixed values. Additionally, the study suggests validating the model under cooling system failures and exploring its application in water-cooled systems. This research is supported by a patent on real-time thermal diagnostics for synchronous machines, highlighting its potential contribution to predictive maintenance and the monitoring of power generation systems.
- Open Access
- 26 November 2024
- Published by MDPI AG in Electronics
- Vol. 13 (23) , 4667
Automatic Classification of Rotating Rectifier Faults in Brushless Synchronous Machines
This paper presents an advanced automatic fault classification method for detecting rotating rectifier faults in brushless synchronous machines (BSMs). The proposed approach employs a multilayer perceptron (MLP) neural network to classify the operational states of the rotating rectifier, including healthy conditions and common fault types: open-diode (OD), shorted-diode (SD), and open-phase (OP). Key machine measurements, available on an ordinary basis in the industry, such as active power (P), reactive power (Q), stator voltage (U), and excitation current (Ie), are used as inputs for this model, allowing for non-invasive, real-time fault detection. This model achieved an overall classification accuracy of 93.4%, with a precision of 94.9% for fault detection and strong recall performance across multiple fault types. The neural network’s robustness is enhanced by advanced data processing techniques, including Gaussian filtering and class balancing through the synthetic minority over-sampling technique (SMOTE). Experimental testing on a modified 5-kVA BSM setup, where rectifier faults were systematically induced, was used to train the network and validate the model’s performance. This method provides a promising tool for real-time condition monitoring of BSMs, improving machine reliability and minimizing downtime in industrial applications.
- 26 November 2024
- Published by MDPI AG in Electronics
- Vol. 13 (23) , 4667
Open AccessAutomatic Classification of Rotating Rectifier Faults in Brushless Synchronous Machines
This paper presents an advanced automatic fault classification method for detecting rotating rectifier faults in brushless synchronous machines (BSMs). The proposed approach employs a multilayer perceptron (MLP) neural network to classify the operational states of the rotating rectifier, including healthy conditions and common fault types: open-diode (OD), shorted-diode (SD), and open-phase (OP). Key machine measurements, available on an ordinary basis in the industry, such as active power (P), reactive power (Q), stator voltage (U), and excitation current (Ie), are used as inputs for this model, allowing for non-invasive, real-time fault detection. This model achieved an overall classification accuracy of 93.4%, with a precision of 94.9% for fault detection and strong recall performance across multiple fault types. The neural network’s robustness is enhanced by advanced data processing techniques, including Gaussian filtering and class balancing through the synthetic minority over-sampling technique (SMOTE). Experimental testing on a modified 5-kVA BSM setup, where rectifier faults were systematically induced, was used to train the network and validate the model’s performance. This method provides a promising tool for real-time condition monitoring of BSMs, improving machine reliability and minimizing downtime in industrial applications.
- Open Access
- 9 September 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (17) , 8061
Influence of Temperature on Brushless Synchronous Machine Field Winding Interturn Fault Severity Estimation
There are numerous methods for detecting interturn faults (ITFs) in the field winding of synchronous machines (SMs). One effective approach is based on comparing theoretical and measured excitation currents. This method is unaffected by rotor temperature in static excitation SMs. However, this paper investigates the influence of rotor temperature in brushless synchronous machines (BSMs), where rotor temperature significantly impacts the exciter excitation current. Extensive experimental tests were conducted on a special BSM with measurable rotor temperature. Given the challenges of measuring rotor temperature in industrial machines, this paper explores the feasibility of using stator temperature in the exciter field current estimation model. The theoretical exciter field current is calculated using a deep neural network (DNN), which incorporates electrical brushless synchronous generator output values and stator temperature, and it is subsequently compared with the measured exciter field current. This method achieves an error rate below 0.5% under healthy conditions, demonstrating its potential for simple implementation in industrial BSMs for ITF detection.
- 9 September 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (17) , 8061
Open AccessInfluence of Temperature on Brushless Synchronous Machine Field Winding Interturn Fault Severity Estimation
There are numerous methods for detecting interturn faults (ITFs) in the field winding of synchronous machines (SMs). One effective approach is based on comparing theoretical and measured excitation currents. This method is unaffected by rotor temperature in static excitation SMs. However, this paper investigates the influence of rotor temperature in brushless synchronous machines (BSMs), where rotor temperature significantly impacts the exciter excitation current. Extensive experimental tests were conducted on a special BSM with measurable rotor temperature. Given the challenges of measuring rotor temperature in industrial machines, this paper explores the feasibility of using stator temperature in the exciter field current estimation model. The theoretical exciter field current is calculated using a deep neural network (DNN), which incorporates electrical brushless synchronous generator output values and stator temperature, and it is subsequently compared with the measured exciter field current. This method achieves an error rate below 0.5% under healthy conditions, demonstrating its potential for simple implementation in industrial BSMs for ITF detection.
- 1 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 39 (2) , 1341-1351
Brushless Synchronous Machine Field Winding Interturn Fault Severity Estimation Through Deep Neural Networks
Interturn faults (ITF) at the main machine field winding in brushless synchronous machines (BSM) are not easy to detect as the scarcity of measurements in the rotor. This paper presents a new field winding ITF severity estimation technique based on deep learning algorithms. The theoretical exciter field current is calculated through an artificial neural network, from the machine output values, and then compared to the measured exciter field current. The estimation and the comparison are carried out without need of other than the machine electrical outputs and the exciter field current measurements. To verify the proposed technique, numerous healthy and faulty condition tests were performed on a special laboratory testbench, with more than 7 million measurements in healthy and more than 1 million in different faulty conditions. So as firstly to train the neural network with healthy operation datasets, and secondly to test its capability to estimate the fault severity level. The use of deep neural networks has proven to enhance the accuracy of the exciter field current estimation with respect to previous theoretical model-based methods, enabling to increase the sensitivity and the reliability of the fault detection and fault severity calculation.
- 1 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 39 (2) , 1341-1351
Brushless Synchronous Machine Field Winding Interturn Fault Severity Estimation Through Deep Neural Networks
Interturn faults (ITF) at the main machine field winding in brushless synchronous machines (BSM) are not easy to detect as the scarcity of measurements in the rotor. This paper presents a new field winding ITF severity estimation technique based on deep learning algorithms. The theoretical exciter field current is calculated through an artificial neural network, from the machine output values, and then compared to the measured exciter field current. The estimation and the comparison are carried out without need of other than the machine electrical outputs and the exciter field current measurements. To verify the proposed technique, numerous healthy and faulty condition tests were performed on a special laboratory testbench, with more than 7 million measurements in healthy and more than 1 million in different faulty conditions. So as firstly to train the neural network with healthy operation datasets, and secondly to test its capability to estimate the fault severity level. The use of deep neural networks has proven to enhance the accuracy of the exciter field current estimation with respect to previous theoretical model-based methods, enabling to increase the sensitivity and the reliability of the fault detection and fault severity calculation.
- Open Access
- 30 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 54713-54723
Synchronous Condenser for European Grid Code Compliance: A Case Study of a PV Power Plant in Spain
The massive integration of renewable energies into the grid towards the de-carbonisation of the power system has a major impact on the stability of the grid. This has led the European Union to establish guidelines on how renewable plants should be connected to the grid, in order to continue to guarantee their operation and stability. These requirements are contained in the European Grid Code. In this code, there are requirements concerning voltage control, reactive power capacity, fault-ride-through and short-circuit current contribution capabilities of renewable power plants. These plants, in particular those powered by photovoltaic inverters, have issues of reactive power capacity, so in order to be able to connect to the grid, they usually require an oversized of the inverters or the installation of reactive power compensation elements, such as capacitor banks, static VAR compensator or synchronous condensers. Moreover, the fault-ride-through and short-circuit current contribution are difficult to fulfil as they are inverter-based generators have a low capacity to supply short-circuit current and, in some cases, they disconnect from the grid. These facts have produced large power losses and protection malfunctions in power system with high photovoltaic power penetration. This paper studies the compliance of the European Grid Code of a 500 MW photovoltaic power plant with and without a synchronous condenser. The results show that not only the use of the synchronous condenser helps for reactive power regulation but also for fault-ride-through and short-circuit current contribution.
- 30 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 54713-54723
Open AccessSynchronous Condenser for European Grid Code Compliance: A Case Study of a PV Power Plant in Spain
The massive integration of renewable energies into the grid towards the de-carbonisation of the power system has a major impact on the stability of the grid. This has led the European Union to establish guidelines on how renewable plants should be connected to the grid, in order to continue to guarantee their operation and stability. These requirements are contained in the European Grid Code. In this code, there are requirements concerning voltage control, reactive power capacity, fault-ride-through and short-circuit current contribution capabilities of renewable power plants. These plants, in particular those powered by photovoltaic inverters, have issues of reactive power capacity, so in order to be able to connect to the grid, they usually require an oversized of the inverters or the installation of reactive power compensation elements, such as capacitor banks, static VAR compensator or synchronous condensers. Moreover, the fault-ride-through and short-circuit current contribution are difficult to fulfil as they are inverter-based generators have a low capacity to supply short-circuit current and, in some cases, they disconnect from the grid. These facts have produced large power losses and protection malfunctions in power system with high photovoltaic power penetration. This paper studies the compliance of the European Grid Code of a 500 MW photovoltaic power plant with and without a synchronous condenser. The results show that not only the use of the synchronous condenser helps for reactive power regulation but also for fault-ride-through and short-circuit current contribution.