Jin-Rang Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jin-Rang Li has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
H Li
Department of Otorhinolaryngology Head and Neck Surgery, Navy General Hospital, Beijing, China
1 shared publicationHong-Guang Guo
1 shared publicationJian-Jun Sun
1 shared publicationWen Xu
1 shared publicationYan-Yan Sun
1 shared publication
Latest Publications
- 1 November 2011
- Vol. 46 (11) , 936-8
[Electronic laryngoscope for transnasal esophageal examination].
To evaluate the value of electronic laryngoscope for transnasal esophagoscopy. The electronic laryngoscope was used for transnasal esophagoscopy in 50 patients from June 2009 to June 2011 in our department. There were 32 males and 18 females with their age ranged from 16-88 years (mean 53.8 years). Before esophagoscopy, 1% ephedrine-dicaine mixture was sprayed into the nasal and pharyngeal cavities for topical anesthesia. The esophagoscopy was used for screening examination in the patients with reflux, globus sensation, dysphagia, head and neck cancer, suspected foreign body, and vocal cord paralysis, etc. The transnasal esophagoscopy with electronic laryngoscope was performed successfully in all the patients. Mild nausea and vomiting occurred in 4 patients, but no patient required to stop the examination. Of the 50 patients, 38 patients (76%) had normal findings and 12 patients (24%) had positive findings of the esophagus. Esophageal cancer was diagnosed in one patient, esophageal foreign body in 2 patients, esophageal injury in one patient, candidal esophagitis in 3 patients, esophagitis in 3 patients, and achalasia of the cardia in 2 patients. The electronic laryngoscope for transnasal esophagoscopy is an alternative to conventional esophagoscopy, which is useful for screening the esophagus in the patients with reflux, globus, dysphagia, head and neck cancer, and suspected foreign body, etc.
- 1 November 2011
- Vol. 46 (11) , 936-8
[Electronic laryngoscope for transnasal esophageal examination].
To evaluate the value of electronic laryngoscope for transnasal esophagoscopy. The electronic laryngoscope was used for transnasal esophagoscopy in 50 patients from June 2009 to June 2011 in our department. There were 32 males and 18 females with their age ranged from 16-88 years (mean 53.8 years). Before esophagoscopy, 1% ephedrine-dicaine mixture was sprayed into the nasal and pharyngeal cavities for topical anesthesia. The esophagoscopy was used for screening examination in the patients with reflux, globus sensation, dysphagia, head and neck cancer, suspected foreign body, and vocal cord paralysis, etc. The transnasal esophagoscopy with electronic laryngoscope was performed successfully in all the patients. Mild nausea and vomiting occurred in 4 patients, but no patient required to stop the examination. Of the 50 patients, 38 patients (76%) had normal findings and 12 patients (24%) had positive findings of the esophagus. Esophageal cancer was diagnosed in one patient, esophageal foreign body in 2 patients, esophageal injury in one patient, candidal esophagitis in 3 patients, esophagitis in 3 patients, and achalasia of the cardia in 2 patients. The electronic laryngoscope for transnasal esophagoscopy is an alternative to conventional esophagoscopy, which is useful for screening the esophagus in the patients with reflux, globus, dysphagia, head and neck cancer, and suspected foreign body, etc.
- 1 September 2010
- Vol. 45 (9) , 719-22
[Design of standard voice sample text for subjective auditory perceptual evaluation of voice disorders].
To design a speech voice sample text with all phonemes in Mandarin for subjective auditory perceptual evaluation of voice disorders. The principles for design of a speech voice sample text are: The short text should include the 21 initials and 39 finals, this may cover all the phonemes in Mandarin. Also, the short text should have some meanings. A short text was made out. It had 155 Chinese words, and included 21 initials and 38 finals (the final, ê, was not included because it was rarely used in Mandarin). Also, the text covered 17 light tones and one "Erhua". The constituent ratios of the initials and finals presented in this short text were statistically similar as those in Mandarin according to the method of similarity of the sample and population (r = 0.742, P < 0.001 and r = 0.844, P < 0.001, respectively). The constituent ratios of the tones presented in this short text were statistically not similar as those in Mandarin (r = 0.731, P > 0.05). A speech voice sample text with all phonemes in Mandarin was made out. The constituent ratios of the initials and finals presented in this short text are similar as those in Mandarin. Its value for subjective auditory perceptual evaluation of voice disorders need further study.
- 1 September 2010
- Vol. 45 (9) , 719-22
[Design of standard voice sample text for subjective auditory perceptual evaluation of voice disorders].
To design a speech voice sample text with all phonemes in Mandarin for subjective auditory perceptual evaluation of voice disorders. The principles for design of a speech voice sample text are: The short text should include the 21 initials and 39 finals, this may cover all the phonemes in Mandarin. Also, the short text should have some meanings. A short text was made out. It had 155 Chinese words, and included 21 initials and 38 finals (the final, ê, was not included because it was rarely used in Mandarin). Also, the text covered 17 light tones and one "Erhua". The constituent ratios of the initials and finals presented in this short text were statistically similar as those in Mandarin according to the method of similarity of the sample and population (r = 0.742, P < 0.001 and r = 0.844, P < 0.001, respectively). The constituent ratios of the tones presented in this short text were statistically not similar as those in Mandarin (r = 0.731, P > 0.05). A speech voice sample text with all phonemes in Mandarin was made out. The constituent ratios of the initials and finals presented in this short text are similar as those in Mandarin. Its value for subjective auditory perceptual evaluation of voice disorders need further study.
- 6 January 2010
- Published by Cambridge University Press (CUP) in The Journal of Laryngology & Otology
- Vol. 124 (8) , 905-908
New repositioning techniques for benign paroxysmal positional vertigo: the Li repositioning manoeuvres
Benign paroxysmal positional vertigo can be treated by repositioning manoeuvres. Current manoeuvres can be cumbersome to perform and require determination of the canal affected, usually by assessing nystagmus direction on provocation. We developed a new series of manoeuvres to manage benign paroxysmal positional vertigo of each semicircular canal. The canal affected, and thus the manoeuvre used in each case, was determined by the patient's subjective report of vertigo on provocative head positioning. The reported manoeuvres were utilised in 216 patients, with an excellent rate of symptom resolution (96.7 per cent). The Li particle repositioning manoeuvres are effective, reliable and simply performed alternatives for the management of benign paroxysmal positional vertigo.
- 6 January 2010
- Published by Cambridge University Press (CUP) in The Journal of Laryngology & Otology
- Vol. 124 (8) , 905-908
New repositioning techniques for benign paroxysmal positional vertigo: the Li repositioning manoeuvres
Benign paroxysmal positional vertigo can be treated by repositioning manoeuvres. Current manoeuvres can be cumbersome to perform and require determination of the canal affected, usually by assessing nystagmus direction on provocation. We developed a new series of manoeuvres to manage benign paroxysmal positional vertigo of each semicircular canal. The canal affected, and thus the manoeuvre used in each case, was determined by the patient's subjective report of vertigo on provocative head positioning. The reported manoeuvres were utilised in 216 patients, with an excellent rate of symptom resolution (96.7 per cent). The Li particle repositioning manoeuvres are effective, reliable and simply performed alternatives for the management of benign paroxysmal positional vertigo.