Jeffrey C. Buchsbaum
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jeffrey C. Buchsbaum has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Mark W. McDonald
Winship Cancer Institute, Emory University, Atlanta, Georgia
2 shared publications - Chee-Wai Cheng
Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, IN, USA
1 shared publication - Indra J. Das
Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, IN, USA
1 shared publication James O. Galle
1 shared publication- Joseph Simmons
Department of Internal Medicine, Marshall University, Huntington, West Virginia, USA
1 shared publication - Kevin P. McMullen
Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, IN, USA
1 shared publication
Latest Publications
- Open Access
- 9 July 2016
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 15 (5) , NP1-NP7
Rapid RBE-Weighted Proton Radiation Dosimetry Risk Assessment
Proton therapy dose is affected by relative biological effectiveness differently than X-ray therapies. The current clinically accepted weighting factor is 1.1 at all positions along the depth–dose profile. However, the relative biological effectiveness correlates with the linear energy transfer, cell or tissue type, and the dose per fraction causing variation of relative biological effectiveness along the depth–dose profile. In this article, we present a simple relative biological effectiveness-weighted treatment planning risk assessment algorithm in 2-dimensions and compare the results with those derived using the standard relative biological effectiveness of 1.1. The isodose distribution profiles for beams were accomplished using matrices that represent coplanar intersecting beams. These matrices were combined and contoured using MATLAB to achieve the distribution of dose. There are some important differences in dose distribution between the dose profiles resulting from the use of relative biological effectiveness = 1.1 and the empirically derived depth-dependent values of relative biological effectiveness. Significant hot spots of up to twice the intended dose are indicated in some beam configurations. This simple and rapid risk analysis could quickly evaluate the safety of various dose delivery schema.
- 9 July 2016
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 15 (5) , NP1-NP7
Open AccessRapid RBE-Weighted Proton Radiation Dosimetry Risk Assessment
Proton therapy dose is affected by relative biological effectiveness differently than X-ray therapies. The current clinically accepted weighting factor is 1.1 at all positions along the depth–dose profile. However, the relative biological effectiveness correlates with the linear energy transfer, cell or tissue type, and the dose per fraction causing variation of relative biological effectiveness along the depth–dose profile. In this article, we present a simple relative biological effectiveness-weighted treatment planning risk assessment algorithm in 2-dimensions and compare the results with those derived using the standard relative biological effectiveness of 1.1. The isodose distribution profiles for beams were accomplished using matrices that represent coplanar intersecting beams. These matrices were combined and contoured using MATLAB to achieve the distribution of dose. There are some important differences in dose distribution between the dose profiles resulting from the use of relative biological effectiveness = 1.1 and the empirically derived depth-dependent values of relative biological effectiveness. Significant hot spots of up to twice the intended dose are indicated in some beam configurations. This simple and rapid risk analysis could quickly evaluate the safety of various dose delivery schema.
- Open Access
- 1 June 2015
- Published by Elsevier in International Journal of Particle Therapy
- Vol. 2 (1) , 11-18
Reirradiation with Proton Therapy for Recurrent Gliomas
Purpose: To evaluate the effectiveness and tolerance of reirradiation with proton therapy (PT) in patients with recurrent gliomas. Patients and Methods: Between 2005 and 2012, 20 patients with recurrent gliomas were irradiated with proton therapy at the Indiana University Health Proton Therapy Center. Three had low-grade gliomas (LGGs, World Health Organization grade I/II), 4 had grade III, and 13 had glioblastoma (GBM, World Health Organization grade IV). The median time interval between initial radiation and reirradiation was 17.4, 62.8, and 15.3 months for LGG, grade III gliomas, and GBMs, respectively. The median dose delivered was 30, 59.4, and 54 Gy (RBE) for the low-grade, grade III, and grade IV tumors, respectively. Results: The median follow-up time from reirradiation was 8.3 months (range, 1.4 to 25.3), and 30% of the patients were alive at time of follow-up evaluation. Only 1 patient with an LGG had died. Median overall survival (OS) from the time of the original pathologic diagnosis ...
- 1 June 2015
- Published by Elsevier in International Journal of Particle Therapy
- Vol. 2 (1) , 11-18
Open AccessReirradiation with Proton Therapy for Recurrent Gliomas
Purpose: To evaluate the effectiveness and tolerance of reirradiation with proton therapy (PT) in patients with recurrent gliomas. Patients and Methods: Between 2005 and 2012, 20 patients with recurrent gliomas were irradiated with proton therapy at the Indiana University Health Proton Therapy Center. Three had low-grade gliomas (LGGs, World Health Organization grade I/II), 4 had grade III, and 13 had glioblastoma (GBM, World Health Organization grade IV). The median time interval between initial radiation and reirradiation was 17.4, 62.8, and 15.3 months for LGG, grade III gliomas, and GBMs, respectively. The median dose delivered was 30, 59.4, and 54 Gy (RBE) for the low-grade, grade III, and grade IV tumors, respectively. Results: The median follow-up time from reirradiation was 8.3 months (range, 1.4 to 25.3), and 30% of the patients were alive at time of follow-up evaluation. Only 1 patient with an LGG had died. Median overall survival (OS) from the time of the original pathologic diagnosis ...
- Open Access
- 2 January 2014
- Published by Springer Nature in Radiation Oncology
- Vol. 9 (1) , 2
Range modulation in proton therapy planning: a simple method for mitigating effects of increased relative biological effectiveness at the end-of-range of clinical proton beams
The increase in relative biological effectiveness (RBE) of proton beams at the distal edge of the spread out Bragg peak (SOBP) is a well-known phenomenon that is difficult to quantify accurately in vivo. For purposes of treatment planning, disallowing the distal SOBP to fall within vulnerable tissues hampers sparing to the extent possible with proton beam therapy (PBT). We propose the distal RBE uncertainty may be straightforwardly mitigated with a technique we call “range modulation”. With range modulation, the distal falloff is smeared, reducing both the dose and average RBE over the terminal few millimeters of the SOBP.
- 2 January 2014
- Published by Springer Nature in Radiation Oncology
- Vol. 9 (1) , 2
Open AccessRange modulation in proton therapy planning: a simple method for mitigating effects of increased relative biological effectiveness at the end-of-range of clinical proton beams
The increase in relative biological effectiveness (RBE) of proton beams at the distal edge of the spread out Bragg peak (SOBP) is a well-known phenomenon that is difficult to quantify accurately in vivo. For purposes of treatment planning, disallowing the distal SOBP to fall within vulnerable tissues hampers sparing to the extent possible with proton beam therapy (PBT). We propose the distal RBE uncertainty may be straightforwardly mitigated with a technique we call “range modulation”. With range modulation, the distal falloff is smeared, reducing both the dose and average RBE over the terminal few millimeters of the SOBP.
- Open Access
- 12 January 2013
- Published by Springer Nature in Radiation Oncology
- Vol. 8 (1) , 14
Technique for sparing previously irradiated critical normal structures in salvage proton craniospinal irradiation
Cranial reirradiation is clinically appropriate in some cases but cumulative radiation dose to critical normal structures remains a practical concern. The authors developed a simple technique in 3D conformal proton craniospinal irradiation (CSI) to block organs at risk (OAR) while minimizing underdosing of adjacent target brain tissue.
- 12 January 2013
- Published by Springer Nature in Radiation Oncology
- Vol. 8 (1) , 14
Open AccessTechnique for sparing previously irradiated critical normal structures in salvage proton craniospinal irradiation
Cranial reirradiation is clinically appropriate in some cases but cumulative radiation dose to critical normal structures remains a practical concern. The authors developed a simple technique in 3D conformal proton craniospinal irradiation (CSI) to block organs at risk (OAR) while minimizing underdosing of adjacent target brain tissue.