João Correia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
João Correia has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Edgar Afecto
Centro Hospitalar Vila Nova de Gaia/Espinho, Gastroenterology
10 shared publications - Rolando Pinho
Department of Gastroenterology, Unidade Local de Saúde Gaia e Espinho, 4430-502 Vila Nova de Gaia, Portugal
10 shared publications - Catarina Gomes
Gastroenterology Department, Centro Hospitalar Vila Nova de Gaia/Espinho, Portugal
9 shared publications - Maria Manuela Estevinho
Department of Gastroenterology, Unidade Local de Saúde Gaia Espinho , Vila Nova de Gaia
8 shared publications Ana Ponte
Gastroenterology Department, Centro Hospitalar de Vila Nova de Gaia/Espinho, Vila Nova de Gaia, Espinho, Portugal
6 shared publications- Jaime Rodrigues
Gastroenterology Department, Centro Hospitalar Vila Nova de Gaia/Espinho, Vila Nova de Gaia, Portugal
3 shared publications
Latest Publications
- Open Access
- 29 October 2024
- Published by S. Karger AG in GE - Portuguese Journal of Gastroenterology
- Vol. 32 (4) , 1-9
Colorectal Endoscopic Full-Thickness Resection: A Portuguese Multicenter Experience Based on a Retrospective Cohort
Introduction: Endoscopic full-thickness resection (EFTR) is a minimally invasive endoscopic technique that allows the resection of complex colorectal lesions, such as non-lifting, peri-appendicular, peri-diverticula, and subepithelial lesions. Published data suggest that EFTR has a technical success and R0 resection rates of 89 and 79%, respectively, and an adverse event rate of 12%. This study summarizes the EFTR experience in nine Portuguese centers with regard to its efficacy and safety. Methods: This was a multicenter uncontrolled retrospective study, including 129 colorectal EFTRs between March 2017 and September 2023. The main outcomes were procedural and technical success, R0 resection, curative resection, adverse events, and recurrence rate. Results: 129 EFTR procedures were conducted, with a technical success rate of 88.4% (114/129). Most lesions were in the right colon, with a median resection size of 25 [10–45] mm. R0 and curative resection rates were 75.9% (85/112) and 58.0% (65/112), respectively. Adverse events occurred in 13.2% (17/129) of patients, mostly due to immediate perforation, appendicitis, or delayed bleeding, needing surgery in 5.4% (7/129). Local recurrence occurred in 5.4% (5/92) of resections. Conclusion: This real-life multicenter study highlights the utility of colorectal EFTR for management of complex and carefully chosen lesions, with an acceptable adverse events rate and need for surgery.
- 29 October 2024
- Published by S. Karger AG in GE - Portuguese Journal of Gastroenterology
- Vol. 32 (4) , 1-9
Open AccessColorectal Endoscopic Full-Thickness Resection: A Portuguese Multicenter Experience Based on a Retrospective Cohort
Introduction: Endoscopic full-thickness resection (EFTR) is a minimally invasive endoscopic technique that allows the resection of complex colorectal lesions, such as non-lifting, peri-appendicular, peri-diverticula, and subepithelial lesions. Published data suggest that EFTR has a technical success and R0 resection rates of 89 and 79%, respectively, and an adverse event rate of 12%. This study summarizes the EFTR experience in nine Portuguese centers with regard to its efficacy and safety. Methods: This was a multicenter uncontrolled retrospective study, including 129 colorectal EFTRs between March 2017 and September 2023. The main outcomes were procedural and technical success, R0 resection, curative resection, adverse events, and recurrence rate. Results: 129 EFTR procedures were conducted, with a technical success rate of 88.4% (114/129). Most lesions were in the right colon, with a median resection size of 25 [10–45] mm. R0 and curative resection rates were 75.9% (85/112) and 58.0% (65/112), respectively. Adverse events occurred in 13.2% (17/129) of patients, mostly due to immediate perforation, appendicitis, or delayed bleeding, needing surgery in 5.4% (7/129). Local recurrence occurred in 5.4% (5/92) of resections. Conclusion: This real-life multicenter study highlights the utility of colorectal EFTR for management of complex and carefully chosen lesions, with an acceptable adverse events rate and need for surgery.
- Open Access
- 15 November 2023
- Published by AVES YAYINCILIK A.Ş. in Turkish Journal of Gastroenterology
- Vol. 34 (11) , 1150-1155
Concordance of Dye-Spraying Chromoendoscopy and Virtual Chromoendoscopy for Colonic Dysplasia Detection in Longstanding Inflammatory Bowel Disease
Background/Aims: In the past, dye-spraying chromoendoscopy was the technique of choice for colonic surveillance in patients with long-standing extensive inflammatory bowel disease. Recent evidence suggests that virtual chromoendoscopy is an equally acceptable technique. Materials and Methods: Eleven gastroenterologists were given a survey with 20 pairs of pictures from inflammatory bowel disease surveillance colonoscopies (10 with nondysplastic lesions, 5 with dysplastic lesions, and 5 with no lesions). Each pair contained the same image captured during colonoscopy using indigo carmine and narrow-band imaging. For each picture, the gastroenterologist assessed the presence/absence of lesion and, when a lesion was identified, assessed the presence/absence of dysplasia and delineated its margins. To compare lesion and dysplasia detection between techniques, sensitivity, specificity, and interobserver agreement were calculated. The chi-square test was used to assess the accuracy of margins delineation. Results: When assessing lesion and dysplasia detection, similar sensitivity and specificity values were obtained for both techniques. Interobserver agreement analysis revealed that dye-spraying chromoendoscopy and virtual chromoendoscopy had a moderate agreement in lesion detection but, for dysplasia detection, dye-spraying chromoendoscopy had a slight agreement [K = 0.11 (0.03-0.18), P < .01] and virtual chromoendoscopy a fair agreement [K = 0.30 (0.22-0.37), P < .01]. Margin delineation was similar between techniques. Conclusion: Sensitivity and specificity for lesion and dysplasia detection, as well as the accuracy of margins delineation, were similar between dye-spraying chromoendoscopy and virtual chromoendoscopy. Interobserver agreement for dysplasia detection was suboptimal in both techniques; however, it was superior when using virtual chromoendoscopy. These findings suggest that virtual chromoendoscopy constitutes a valid alternative for dysplasia screening in inflammatory bowel disease. Cite this article as: Correia JPL, Ponte A, Proença L, et al. Concordance of dye-spraying chromoendoscopy and virtual chromoendoscopy for colonic dysplasia detection in longstanding inflammatory bowel disease. Turk J Gastroenterol. 2023;34(11):1150-1155.
- 15 November 2023
- Published by AVES YAYINCILIK A.Ş. in Turkish Journal of Gastroenterology
- Vol. 34 (11) , 1150-1155
Open AccessConcordance of Dye-Spraying Chromoendoscopy and Virtual Chromoendoscopy for Colonic Dysplasia Detection in Longstanding Inflammatory Bowel Disease
Background/Aims: In the past, dye-spraying chromoendoscopy was the technique of choice for colonic surveillance in patients with long-standing extensive inflammatory bowel disease. Recent evidence suggests that virtual chromoendoscopy is an equally acceptable technique. Materials and Methods: Eleven gastroenterologists were given a survey with 20 pairs of pictures from inflammatory bowel disease surveillance colonoscopies (10 with nondysplastic lesions, 5 with dysplastic lesions, and 5 with no lesions). Each pair contained the same image captured during colonoscopy using indigo carmine and narrow-band imaging. For each picture, the gastroenterologist assessed the presence/absence of lesion and, when a lesion was identified, assessed the presence/absence of dysplasia and delineated its margins. To compare lesion and dysplasia detection between techniques, sensitivity, specificity, and interobserver agreement were calculated. The chi-square test was used to assess the accuracy of margins delineation. Results: When assessing lesion and dysplasia detection, similar sensitivity and specificity values were obtained for both techniques. Interobserver agreement analysis revealed that dye-spraying chromoendoscopy and virtual chromoendoscopy had a moderate agreement in lesion detection but, for dysplasia detection, dye-spraying chromoendoscopy had a slight agreement [K = 0.11 (0.03-0.18), P < .01] and virtual chromoendoscopy a fair agreement [K = 0.30 (0.22-0.37), P < .01]. Margin delineation was similar between techniques. Conclusion: Sensitivity and specificity for lesion and dysplasia detection, as well as the accuracy of margins delineation, were similar between dye-spraying chromoendoscopy and virtual chromoendoscopy. Interobserver agreement for dysplasia detection was suboptimal in both techniques; however, it was superior when using virtual chromoendoscopy. These findings suggest that virtual chromoendoscopy constitutes a valid alternative for dysplasia screening in inflammatory bowel disease. Cite this article as: Correia JPL, Ponte A, Proença L, et al. Concordance of dye-spraying chromoendoscopy and virtual chromoendoscopy for colonic dysplasia detection in longstanding inflammatory bowel disease. Turk J Gastroenterol. 2023;34(11):1150-1155.
- Open Access
Capsule Enteroscopy Using the Mirocam® versus OMOM® Systems: A Matched Case–Control Study
Although several devices are available for small bowel capsule endoscopy, few studies have compared their visualization quality and diagnostic yield, despite users reporting subjective differences between them. This study aims to compare two widely used systems (Mirocam® MC1600 and OMOM® HD). Patients who underwent OMOM® HD capsule enteroscopy between August 2022 and February 2023 were prospectively included consecutively (cases). Controls were retrospectively selected from a database of patients who underwent Mirocam® MC1600 enteroscopy between March 2018 and July 2022 in a 1:1 ratio. Controls were matched for potential confounders (age, sex, indication, hospitalization, comorbidities, and opioid prescription). The small bowel cleanliness (global and divided by tertiles), the diagnostic yield (positive findings) and the transit times (TT) were compared. Overall, 214 patients were included (107:107). Global bowel preparation was similar between the OMOM® and Mirocam® groups. However, the average scores for each tertile were significantly higher when the OMOM® HD capsule was used (p < 0.05). Small bowel TT was shorter for OMOM® HD (265 ± 118 versus 307 ± 87 min, p = 0.020), while the diagnostic yield (55.0%) and relative distribution of lesions were similar. This study suggests that capsule characteristics, namely resolution, and illumination, systematically interfere with the perception of preparation quality. However, this did not affect the diagnostic yield.
Open AccessCapsule Enteroscopy Using the Mirocam® versus OMOM® Systems: A Matched Case–Control Study
Although several devices are available for small bowel capsule endoscopy, few studies have compared their visualization quality and diagnostic yield, despite users reporting subjective differences between them. This study aims to compare two widely used systems (Mirocam® MC1600 and OMOM® HD). Patients who underwent OMOM® HD capsule enteroscopy between August 2022 and February 2023 were prospectively included consecutively (cases). Controls were retrospectively selected from a database of patients who underwent Mirocam® MC1600 enteroscopy between March 2018 and July 2022 in a 1:1 ratio. Controls were matched for potential confounders (age, sex, indication, hospitalization, comorbidities, and opioid prescription). The small bowel cleanliness (global and divided by tertiles), the diagnostic yield (positive findings) and the transit times (TT) were compared. Overall, 214 patients were included (107:107). Global bowel preparation was similar between the OMOM® and Mirocam® groups. However, the average scores for each tertile were significantly higher when the OMOM® HD capsule was used (p < 0.05). Small bowel TT was shorter for OMOM® HD (265 ± 118 versus 307 ± 87 min, p = 0.020), while the diagnostic yield (55.0%) and relative distribution of lesions were similar. This study suggests that capsule characteristics, namely resolution, and illumination, systematically interfere with the perception of preparation quality. However, this did not affect the diagnostic yield.
- Open Access
- 10 August 2023
- Published by S. Karger AG in GE - Portuguese Journal of Gastroenterology
- Vol. 31 (3) , 196-202
Small Bowel Villous Atrophy in a Young Patient: A Challenging Diagnosis
Common variable immunodeficiency enteropathy is a sprue-like disease, which may manifest as a severe malabsorption syndrome with nutritional deficits and cachexia. The authors report a case of a 33-year-old Afghan man, who presented to the emergency department due to chronic watery diarrhea and severe malnourishment. He had been previously misdiagnosed with celiac disease in his early adulthood; however, this was based on inconclusive findings. After a thorough diagnostic workup, the final diagnosis of common variable immunodeficiency enteropathy with symptomatic norovirus infection of the gut was obtained during his prolonged hospitalization. A slow but progressive improvement was observed with immunoglobulin replacement therapy, corticotherapy, and ribavirin treatment. This is a noteworthy case of a rare malabsorption disorder, and it reviews important aspects concerning the differential diagnosis of small bowel villous atrophy of unknown etiology, as well as gastrointestinal manifestations of common variable immunodeficiency disorder.
- 10 August 2023
- Published by S. Karger AG in GE - Portuguese Journal of Gastroenterology
- Vol. 31 (3) , 196-202
Open AccessSmall Bowel Villous Atrophy in a Young Patient: A Challenging Diagnosis
Common variable immunodeficiency enteropathy is a sprue-like disease, which may manifest as a severe malabsorption syndrome with nutritional deficits and cachexia. The authors report a case of a 33-year-old Afghan man, who presented to the emergency department due to chronic watery diarrhea and severe malnourishment. He had been previously misdiagnosed with celiac disease in his early adulthood; however, this was based on inconclusive findings. After a thorough diagnostic workup, the final diagnosis of common variable immunodeficiency enteropathy with symptomatic norovirus infection of the gut was obtained during his prolonged hospitalization. A slow but progressive improvement was observed with immunoglobulin replacement therapy, corticotherapy, and ribavirin treatment. This is a noteworthy case of a rare malabsorption disorder, and it reviews important aspects concerning the differential diagnosis of small bowel villous atrophy of unknown etiology, as well as gastrointestinal manifestations of common variable immunodeficiency disorder.
- Open Access
- 10 April 2023
- Published by MDPI AG in Biomedicines
- Vol. 11 (4) , 1139
Hybrid Argon Plasma Coagulation for Barrett’s Esophagus and for Colonic Mucosal Resection—A Systematic Review and Meta-Analysis
Hybrid argon plasma coagulation (hAPC) is a novel technique that combines conventional argon plasma coagulation and waterjet submucosal expansion. The aims of this metanalysis were to evaluate the efficacy and safety of hAPC in the setting of Barret’s esophagus (BE) ablation and as an adjunct to colonic endoscopic mucosal resection (EMR). Four electronic databases were searched, and the results were analyzed by two independent authors. Random-effects meta-analyses of the proportions of endoscopic and histologic remission (for BE), recurrence, and post-procedure adverse events were performed using R. Studies’ reporting quality was also assessed. From the 979 identified records, 13 studies were included (10 regarding BE and three colonic EMR). The pooled percentages of endoscopic and histologic remission after hAPC for BE were 95% (95% confidence interval [CI] 91–99, I2 = 34) and 90% (95%CI 84–95, I2 = 46), respectively, while major adverse events and recurrence were registered in 2% (95%CI 0–5, I2 = 41) and 11% (95%CI 2–27, I2 = 11), respectively. Concerning hAPC-assisted EMR, the pooled percentages of major adverse events and recurrence were 5% (95%CI 2–10, I2 = 0) and 1% (95%CI 0–3, I2 = 40). Evidence suggests that the main advantages of hAPC are the increase in safety in the setting of BE ablation and the reduction of local recurrence after colonic EMR. Trials comparing hAPC with standard strategies are required to support its use for these indications.
- 10 April 2023
- Published by MDPI AG in Biomedicines
- Vol. 11 (4) , 1139
Open AccessHybrid Argon Plasma Coagulation for Barrett’s Esophagus and for Colonic Mucosal Resection—A Systematic Review and Meta-Analysis
Hybrid argon plasma coagulation (hAPC) is a novel technique that combines conventional argon plasma coagulation and waterjet submucosal expansion. The aims of this metanalysis were to evaluate the efficacy and safety of hAPC in the setting of Barret’s esophagus (BE) ablation and as an adjunct to colonic endoscopic mucosal resection (EMR). Four electronic databases were searched, and the results were analyzed by two independent authors. Random-effects meta-analyses of the proportions of endoscopic and histologic remission (for BE), recurrence, and post-procedure adverse events were performed using R. Studies’ reporting quality was also assessed. From the 979 identified records, 13 studies were included (10 regarding BE and three colonic EMR). The pooled percentages of endoscopic and histologic remission after hAPC for BE were 95% (95% confidence interval [CI] 91–99, I2 = 34) and 90% (95%CI 84–95, I2 = 46), respectively, while major adverse events and recurrence were registered in 2% (95%CI 0–5, I2 = 41) and 11% (95%CI 2–27, I2 = 11), respectively. Concerning hAPC-assisted EMR, the pooled percentages of major adverse events and recurrence were 5% (95%CI 2–10, I2 = 0) and 1% (95%CI 0–3, I2 = 40). Evidence suggests that the main advantages of hAPC are the increase in safety in the setting of BE ablation and the reduction of local recurrence after colonic EMR. Trials comparing hAPC with standard strategies are required to support its use for these indications.
- Open Access
- 4 November 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (11) , 2685
Very High Yield of Urgent Small-Bowel Capsule Endoscopy for Ongoing Overt Suspected Small-Bowel Bleeding Irrespective of the Usual Predictive Factors
Evidence for an urgent approach to ongoing overt suspected small-bowel bleeding (SSBB) is scarce. We aimed to analyze our series of urgent small-bowel capsule endoscopies (SBCEs) for ongoing overt SSBB and to identify factors associated with positive findings and outcomes. A retrospective study of all SBCEs performed in the first 48 h after admission for overt SSBB between January 2006 and February 2022 was performed. Descriptive and inferential analyses (univariate and multivariable) were performed. Eighty-three urgent SBCEs were performed for overt SSBB. Patients were mostly men (69.2%, median age 68) and were followed for a median of 58.2 months (range 5–176). The diagnostic yield was 80.7%; in 60.2%, blood was detected in the small bowel (SB), while in 50.6%, a bleeding lesion was identified, mostly angioectasia. Patients with diabetes mellitus or taking NSAIDs were more prone to present SB findings, yet the explanatory power was low. Endoscopic or surgical treatments were performed in 28.9% and 19.3%, respectively, with the “non-conservative” therapeutic yield being 56.6%. Rebleeding occurred in 20.5% and was associated in the multivariable analysis with the female gender and anticoagulants use. This cohort of urgent SBCE, the largest from a European center, reinforces the usefulness of SBCE for ongoing overt SSBB management. This prompt performance of this procedure is highly effective, regardless of patients’ features.
- 4 November 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (11) , 2685
Open AccessVery High Yield of Urgent Small-Bowel Capsule Endoscopy for Ongoing Overt Suspected Small-Bowel Bleeding Irrespective of the Usual Predictive Factors
Evidence for an urgent approach to ongoing overt suspected small-bowel bleeding (SSBB) is scarce. We aimed to analyze our series of urgent small-bowel capsule endoscopies (SBCEs) for ongoing overt SSBB and to identify factors associated with positive findings and outcomes. A retrospective study of all SBCEs performed in the first 48 h after admission for overt SSBB between January 2006 and February 2022 was performed. Descriptive and inferential analyses (univariate and multivariable) were performed. Eighty-three urgent SBCEs were performed for overt SSBB. Patients were mostly men (69.2%, median age 68) and were followed for a median of 58.2 months (range 5–176). The diagnostic yield was 80.7%; in 60.2%, blood was detected in the small bowel (SB), while in 50.6%, a bleeding lesion was identified, mostly angioectasia. Patients with diabetes mellitus or taking NSAIDs were more prone to present SB findings, yet the explanatory power was low. Endoscopic or surgical treatments were performed in 28.9% and 19.3%, respectively, with the “non-conservative” therapeutic yield being 56.6%. Rebleeding occurred in 20.5% and was associated in the multivariable analysis with the female gender and anticoagulants use. This cohort of urgent SBCE, the largest from a European center, reinforces the usefulness of SBCE for ongoing overt SSBB management. This prompt performance of this procedure is highly effective, regardless of patients’ features.
- Open Access
- 30 October 2022
- Published by Maad Rayan Publishing Company in Middle East Journal of Digestive Diseases
- Vol. 14 (4) , 488-490
Overt Bleeding from Small Bowel Ulcers due to Microscopic Polyangiitis
Overt Bleeding from Small Bowel Ulcers due to Microscopic Polyangiitis
- 30 October 2022
- Published by Maad Rayan Publishing Company in Middle East Journal of Digestive Diseases
- Vol. 14 (4) , 488-490
Open AccessOvert Bleeding from Small Bowel Ulcers due to Microscopic Polyangiitis
Overt Bleeding from Small Bowel Ulcers due to Microscopic Polyangiitis
- 1 July 2022
- Published by AVES YAYINCILIK A.Ş. in Turkish Journal of Gastroenterology
- Vol. 33 (7) , 570-575
Readjustment of Capsule Endoscopy Protocols to the COVID-19 Pandemic in a Portuguese Tertiary Center
Background: The prevention of severe acute respiratory syndrome corona virus 2 transmission implies several social distancing mea- sures, imposing a change in the protocols of several hospital departments. Capsule endoscopy protocols changes were implemented and evaluated in a Portuguese tertiary center. Methods: The authors compared pre-pandemic and peri-pandemic protocols, the latter favoring social distancing, used in MiroCam (IntroMedic, Seoul, Korea) and PillCam Crohn (Medtronic, Minneapolis, Minn, USA) capsule endoscopy, in a Gastroenterology Department of a tertiary center. All capsule endoscopy performed in outpatients between February 2018 and September 2020 was included. The authors compared significant lesions detection rate, completeness of procedure, adequate bowel preparation, complications rate, and patient satisfaction (through a brief phone call survey) among the protocols. Results: This study included 70 MiroCam CE and 43 PillCam Crohn capsule endoscopy. No statistically significant differences concern- ing performance measures and patients satisfaction were found among the pre-pandemic protocol and the peri-pandemic protocol in MiroCam capsule endoscopy. Conversely, in PillCam Crohn capsule endoscopy, the rate of complete exams was significantly inferior in the peri-pandemic protocol (84.8% vs 50.0%, P = .036), with no other statistically significant differences in the remaining parameters. Conclusion: The performance measures and patient satisfaction were similar among the protocols analyzed for MiroCam capsule endoscopy. Thus, the readjustment of this capsule endoscopy system, which favors a reduction in hospital stay, appears to be a good alternative to the former protocols in this pandemic era. In contrast, the rate of complete exams was significantly inferior in the adapted protocol to the pandemic era for PillCam Crohn capsule endoscopy, disfavoring its maintenance in the clinical practice.
- 1 July 2022
- Published by AVES YAYINCILIK A.Ş. in Turkish Journal of Gastroenterology
- Vol. 33 (7) , 570-575
Readjustment of Capsule Endoscopy Protocols to the COVID-19 Pandemic in a Portuguese Tertiary Center
Background: The prevention of severe acute respiratory syndrome corona virus 2 transmission implies several social distancing mea- sures, imposing a change in the protocols of several hospital departments. Capsule endoscopy protocols changes were implemented and evaluated in a Portuguese tertiary center. Methods: The authors compared pre-pandemic and peri-pandemic protocols, the latter favoring social distancing, used in MiroCam (IntroMedic, Seoul, Korea) and PillCam Crohn (Medtronic, Minneapolis, Minn, USA) capsule endoscopy, in a Gastroenterology Department of a tertiary center. All capsule endoscopy performed in outpatients between February 2018 and September 2020 was included. The authors compared significant lesions detection rate, completeness of procedure, adequate bowel preparation, complications rate, and patient satisfaction (through a brief phone call survey) among the protocols. Results: This study included 70 MiroCam CE and 43 PillCam Crohn capsule endoscopy. No statistically significant differences concern- ing performance measures and patients satisfaction were found among the pre-pandemic protocol and the peri-pandemic protocol in MiroCam capsule endoscopy. Conversely, in PillCam Crohn capsule endoscopy, the rate of complete exams was significantly inferior in the peri-pandemic protocol (84.8% vs 50.0%, P = .036), with no other statistically significant differences in the remaining parameters. Conclusion: The performance measures and patient satisfaction were similar among the protocols analyzed for MiroCam capsule endoscopy. Thus, the readjustment of this capsule endoscopy system, which favors a reduction in hospital stay, appears to be a good alternative to the former protocols in this pandemic era. In contrast, the rate of complete exams was significantly inferior in the adapted protocol to the pandemic era for PillCam Crohn capsule endoscopy, disfavoring its maintenance in the clinical practice.
- Open Access
- 20 May 2022
- Published by S. Karger AG in GE - Portuguese Journal of Gastroenterology
- Vol. 30 (5) , 336-342
Small-Bowel Angioectasias: Are They Responsible for a Real Impact on Survival?
Introduction: This study aimed to evaluate the effect of small-bowel angioectasia on survival, given the hypothesis that angioectasia might be an independent risk factor of frailty and poor outcomes. Methods: In this retrospective cohort study, all patients undergoing small-bowel capsule endoscopy between 2010 and 2013 for obscure gastrointestinal bleeding from a Portuguese tertiary centre were included. Follow-up started after capsule endoscopy and ended upon death or end of the study (November 2020). Survival analysis was performed using a Cox proportional-hazards model, in order to analyse the effect of small-bowel angioectasia on survival as well as potentially confounding factors (age, vascular diseases and chronic kidney disease). Results: A total of 176 patients were included in this study (50.6% male), with a median age of 68.5 years (IQR 24). The median follow-up was 7 years (IQR 4), during which 67 (38.1%) patients died. Seventy-three (41.5%) patients had at least one small-bowel angioectasia on capsule endoscopy. On multivariate Cox regression analysis, only age, peripheral arterial disease, history of previous mesenteric ischaemia and chronic kidney disease were independent risk factors of death. The presence of small-bowel angioectasia did not affect survival in this analysis (HR 1.30; 95% CI 0.75–2.23; p = 0.35). Conclusion: In this retrospective cohort study, some comorbidities and age were independent predictors of poor survival. The presence of small-bowel angioectasia per se did not affect survival.
- 20 May 2022
- Published by S. Karger AG in GE - Portuguese Journal of Gastroenterology
- Vol. 30 (5) , 336-342
Open AccessSmall-Bowel Angioectasias: Are They Responsible for a Real Impact on Survival?
Introduction: This study aimed to evaluate the effect of small-bowel angioectasia on survival, given the hypothesis that angioectasia might be an independent risk factor of frailty and poor outcomes. Methods: In this retrospective cohort study, all patients undergoing small-bowel capsule endoscopy between 2010 and 2013 for obscure gastrointestinal bleeding from a Portuguese tertiary centre were included. Follow-up started after capsule endoscopy and ended upon death or end of the study (November 2020). Survival analysis was performed using a Cox proportional-hazards model, in order to analyse the effect of small-bowel angioectasia on survival as well as potentially confounding factors (age, vascular diseases and chronic kidney disease). Results: A total of 176 patients were included in this study (50.6% male), with a median age of 68.5 years (IQR 24). The median follow-up was 7 years (IQR 4), during which 67 (38.1%) patients died. Seventy-three (41.5%) patients had at least one small-bowel angioectasia on capsule endoscopy. On multivariate Cox regression analysis, only age, peripheral arterial disease, history of previous mesenteric ischaemia and chronic kidney disease were independent risk factors of death. The presence of small-bowel angioectasia did not affect survival in this analysis (HR 1.30; 95% CI 0.75–2.23; p = 0.35). Conclusion: In this retrospective cohort study, some comorbidities and age were independent predictors of poor survival. The presence of small-bowel angioectasia per se did not affect survival.
- Open Access
- 5 May 2022
- Published by S. Karger AG in GE - Portuguese Journal of Gastroenterology
- Vol. 30 (4) , 319-321
Difficult Intragastric Balloon Retrieval: A Different Technique
Intragastric balloon is a temporary nonsurgical treatment for weight loss [1, 2]. The standard routine for its removal consists of: (i) puncturing with a needle held in the aspirator; (ii) pushing the needle inside the balloon, leaving the catheter inside; (iii) connecting the catheter to a vacuum drainage device, and then aspiring the entire balloon content; (iv) removing the collapsed balloon with a wire grasper. We hereby present a difficult intragastric balloon retrieval using a different technique.A 39-year-old woman, with no significant medical history but obesity, was referred to our center after an unsuccessful Bioenteric Intragastric Balloon (BIB) retrieval. The balloon had been placed 5 months earlier and since then the patient had lost 8 Kg. On the first retrieval attempt, the aspiration of the BIB content with a standard BIB kit (Apollo Endosurgery, consisting of a wire grasper removal instrument and a needle aspirator) had not resulted in its full collapse. Therefore, the balloon could not be removed, as it did not pass the esophago-gastric junction. At our unit, under propofol sedation, a second attempt to fully aspirate the balloon with the same system was ineffective, as the surface of the balloon was pliable (Fig. 1). While mobilizing the BIB with the two-prong grasper device, a small hole was accidentally made (Fig. 2a); this allowed the needle to be inserted and the suctioning of some fluid. However, it was not possible to fully aspirate the balloon. Therefore, to promote passive emptying, we decided to enlarge the hole with a through-the-scope balloon dilator (18/19/20 mm, EndoFlex® Ref. 34118PRO; Fig. 2b, c). This allowed the volume of the balloon to be reduced, which was then gently retrieved with the two-prong grasper (Fig. 2d). Re-examination of the stomach and esophagus was unremarkable, and the women was asymptomatic afterwards. Balloon retrieval may be a challenging task, especially when it is maintained longer than the recommended 6 months [3]. Some nonstandard retrieval techniques have already been described, such as the use of a larger needle with a stronger suction device, the use of a snare around the end of the endoscope, or spraying vegetable oil over the balloon to ease balloon passage [4]. A procedure identical to ours was described by a Canadian group, who used a through-the-scope balloon dilator to allow intragastric balloon decompression. The balloon was then removed through an overtube, using a snare [5].Written informed consent was obtained from the patient for publication of this case report and any accompanying images.The authors have no conflicts of interest to declare.There was no funding for this work.M.M.E., A.C.G., and R.P. were involved in the endoscopic procedure and in manuscript drafting. J.C. and E.A. were involved in manuscript drafting and critical revision. T.F. reviewed the manuscript and gave final approval. All authors approved the final version.All data generated or analyzed during this study are included in this article. Further enquiries can be directed to the corresponding author.
- 5 May 2022
- Published by S. Karger AG in GE - Portuguese Journal of Gastroenterology
- Vol. 30 (4) , 319-321
Open AccessDifficult Intragastric Balloon Retrieval: A Different Technique
Intragastric balloon is a temporary nonsurgical treatment for weight loss [1, 2]. The standard routine for its removal consists of: (i) puncturing with a needle held in the aspirator; (ii) pushing the needle inside the balloon, leaving the catheter inside; (iii) connecting the catheter to a vacuum drainage device, and then aspiring the entire balloon content; (iv) removing the collapsed balloon with a wire grasper. We hereby present a difficult intragastric balloon retrieval using a different technique.A 39-year-old woman, with no significant medical history but obesity, was referred to our center after an unsuccessful Bioenteric Intragastric Balloon (BIB) retrieval. The balloon had been placed 5 months earlier and since then the patient had lost 8 Kg. On the first retrieval attempt, the aspiration of the BIB content with a standard BIB kit (Apollo Endosurgery, consisting of a wire grasper removal instrument and a needle aspirator) had not resulted in its full collapse. Therefore, the balloon could not be removed, as it did not pass the esophago-gastric junction. At our unit, under propofol sedation, a second attempt to fully aspirate the balloon with the same system was ineffective, as the surface of the balloon was pliable (Fig. 1). While mobilizing the BIB with the two-prong grasper device, a small hole was accidentally made (Fig. 2a); this allowed the needle to be inserted and the suctioning of some fluid. However, it was not possible to fully aspirate the balloon. Therefore, to promote passive emptying, we decided to enlarge the hole with a through-the-scope balloon dilator (18/19/20 mm, EndoFlex® Ref. 34118PRO; Fig. 2b, c). This allowed the volume of the balloon to be reduced, which was then gently retrieved with the two-prong grasper (Fig. 2d). Re-examination of the stomach and esophagus was unremarkable, and the women was asymptomatic afterwards. Balloon retrieval may be a challenging task, especially when it is maintained longer than the recommended 6 months [3]. Some nonstandard retrieval techniques have already been described, such as the use of a larger needle with a stronger suction device, the use of a snare around the end of the endoscope, or spraying vegetable oil over the balloon to ease balloon passage [4]. A procedure identical to ours was described by a Canadian group, who used a through-the-scope balloon dilator to allow intragastric balloon decompression. The balloon was then removed through an overtube, using a snare [5].Written informed consent was obtained from the patient for publication of this case report and any accompanying images.The authors have no conflicts of interest to declare.There was no funding for this work.M.M.E., A.C.G., and R.P. were involved in the endoscopic procedure and in manuscript drafting. J.C. and E.A. were involved in manuscript drafting and critical revision. T.F. reviewed the manuscript and gave final approval. All authors approved the final version.All data generated or analyzed during this study are included in this article. Further enquiries can be directed to the corresponding author.