Gülşah Yenier Yurdagüven
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gülşah Yenier Yurdagüven has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Elif Çiftçioğlu
Department of Endodontics, Faculty of Dentistry, İstanbul Okan University, 34947 İstanbul, Türkiye
2 shared publications Ayşe Arzu Aykor
ProDenta Dental Clinic, Istanbul, Turkey
1 shared publication- Berna Tarim
Nisantasi Universitesi
1 shared publication - Burcu Dikici
Department of Restorative Dentistry, Faculty of Dentistry, Yeditepe University, 34728 İstanbul, Turkey
1 shared publication - Elif Türkeş Başaran
Department of Restorative Dentistry, Faculty of Dentistry, Yeditepe University, Istanbul, Turkey
1 shared publication - Fatma Şehnaz Kazokoğlu
Department of Prosthetic Dentistry, Bezmialem University Faculty of Dentistry, Istanbul, Turkey
1 shared publication
Latest Publications
- 30 April 2026
- Published by AVES YAYINCILIK A.Ş. in Essentials of Dentistry
- Vol. 5, 1-6
Effect of Different Light Intensities on the Compressive Strength of Posterior Composite Resins
Background: The clinical success and longevity of composite resins are highly dependent on the degree of polymerization, which is influenced by various factors, including the light intensity of the light-curing unit. Inadequate polymerization can compromise mechanical properties, particularly in posterior regions. Although light emitting diode (LED) units are commonly used in clinical practice, there is limited evidence regarding the impact of different light intensities on the compressive strength (CS) of current composite resins.Methods: A total of 135 cylindrical specimens (n=45 per composite resin) were fabricated using standardized silicone molds (4 mm diameter × 6 mm height). Three composite resins—Filtek Z250 (3M ESPE), Estelite Posterior (Tokuyama), and G-ænial posterior (GC)—were light-cured with an LED unit (Elipar DeepCure-S, 3M ESPE) at 3 different light intensities (60%, 80%, 100%), following manufacturer-recommended durations. Specimens were stored at 37°C in 100% humidity for 24 hours before testing. Compressive strength was measured using a universal testing machine at a crosshead speed of 1 mm/min. Two-way ANOVA and Tukey Tukey’s honest significant difference (HSD) tests were used for statistical analysis (P=.05).Results: Both light intensity and composite resin significantly affected CS (P < .05), whereas their interaction was not significant. Filtek Z250 and Estelite Posterior showed higher CS than G-ænial Posterior at all light intensities. Compressive strength increased with higher light intensity across all groups.Conclusion: The increase in CS observed with higher light intensity emphasizes the importance of tailoring polymerization protocols to the unique characteristics of each composite resin.Cite this article as: Yurdagüven GY. Effect of different light intensities on the compressive strength of posterior composite resins. Essent Dent. 2026, 5, 0078, doi:10.5152/EssentDent.2026.25078.
- 30 April 2026
- Published by AVES YAYINCILIK A.Ş. in Essentials of Dentistry
- Vol. 5, 1-6
Effect of Different Light Intensities on the Compressive Strength of Posterior Composite Resins
Background: The clinical success and longevity of composite resins are highly dependent on the degree of polymerization, which is influenced by various factors, including the light intensity of the light-curing unit. Inadequate polymerization can compromise mechanical properties, particularly in posterior regions. Although light emitting diode (LED) units are commonly used in clinical practice, there is limited evidence regarding the impact of different light intensities on the compressive strength (CS) of current composite resins.Methods: A total of 135 cylindrical specimens (n=45 per composite resin) were fabricated using standardized silicone molds (4 mm diameter × 6 mm height). Three composite resins—Filtek Z250 (3M ESPE), Estelite Posterior (Tokuyama), and G-ænial posterior (GC)—were light-cured with an LED unit (Elipar DeepCure-S, 3M ESPE) at 3 different light intensities (60%, 80%, 100%), following manufacturer-recommended durations. Specimens were stored at 37°C in 100% humidity for 24 hours before testing. Compressive strength was measured using a universal testing machine at a crosshead speed of 1 mm/min. Two-way ANOVA and Tukey Tukey’s honest significant difference (HSD) tests were used for statistical analysis (P=.05).Results: Both light intensity and composite resin significantly affected CS (P < .05), whereas their interaction was not significant. Filtek Z250 and Estelite Posterior showed higher CS than G-ænial Posterior at all light intensities. Compressive strength increased with higher light intensity across all groups.Conclusion: The increase in CS observed with higher light intensity emphasizes the importance of tailoring polymerization protocols to the unique characteristics of each composite resin.Cite this article as: Yurdagüven GY. Effect of different light intensities on the compressive strength of posterior composite resins. Essent Dent. 2026, 5, 0078, doi:10.5152/EssentDent.2026.25078.
- Open Access
- 25 November 2025
- Published by Springer Nature in BMC Medical Education
- Vol. 25 (1) , 1647
The impact of preclinical education on operative and restorative skills in dental students: a survey-based evaluation
Aim: In response to the nationwide measures due to the COVID-19 pandemic, face-to-face preclinical dental education transitioned to a hybrid format. This survey aimed to assess the impact of hybrid education on dental students’ transition to clinical practice and to evaluate the efficacy and sustainability of preclinical education delivered in a hybrid model. Methods: The multi-centered questionnaire survey was e-mailed to students who received preclinical education in dentistry faculties from 2018 to 2020 and subsequently proceeded to clinical education. Students who received preclinical education in face-to-face and hybrid formats were included. The survey examined how preclinical education affects restorative clinical skills and students’ perceptions. It compared students with different levels of preclinical education using descriptive statistics and the Mann-Whitney U test for quantitative analysis ( p < 0.05). Results: Analysis of responses from 341 participants revealed that students who received face-to-face preclinical education exhibited greater confidence in performing restorative procedures than students educated in a hybrid format. Nonetheless, both groups demonstrated a high level of self-assurance. Conclusion: This study highlights the challenges faced by students in hybrid learning and provides strategies to overcome them. With proper adjustments, hybrid learning can become a reliable and flexible component of dental education, maintaining continuity and quality even in challenging circumstances. The study also informs future curriculum planning by emphasizing the importance of preparedness for distance-based learning, flexibility in clinical scheduling, and early identification of gaps in clinical skill development.
- 25 November 2025
- Published by Springer Nature in BMC Medical Education
- Vol. 25 (1) , 1647
Open AccessThe impact of preclinical education on operative and restorative skills in dental students: a survey-based evaluation
Aim: In response to the nationwide measures due to the COVID-19 pandemic, face-to-face preclinical dental education transitioned to a hybrid format. This survey aimed to assess the impact of hybrid education on dental students’ transition to clinical practice and to evaluate the efficacy and sustainability of preclinical education delivered in a hybrid model. Methods: The multi-centered questionnaire survey was e-mailed to students who received preclinical education in dentistry faculties from 2018 to 2020 and subsequently proceeded to clinical education. Students who received preclinical education in face-to-face and hybrid formats were included. The survey examined how preclinical education affects restorative clinical skills and students’ perceptions. It compared students with different levels of preclinical education using descriptive statistics and the Mann-Whitney U test for quantitative analysis ( p < 0.05). Results: Analysis of responses from 341 participants revealed that students who received face-to-face preclinical education exhibited greater confidence in performing restorative procedures than students educated in a hybrid format. Nonetheless, both groups demonstrated a high level of self-assurance. Conclusion: This study highlights the challenges faced by students in hybrid learning and provides strategies to overcome them. With proper adjustments, hybrid learning can become a reliable and flexible component of dental education, maintaining continuity and quality even in challenging circumstances. The study also informs future curriculum planning by emphasizing the importance of preparedness for distance-based learning, flexibility in clinical scheduling, and early identification of gaps in clinical skill development.
- Open Access
- 22 October 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-12
Clinical evaluation of different solvent type and HEMA-content of universal adhesive systems in non-carious cervical lesions: a two-year double-blind split-mouth randomized clinical trial
Comparative analyses of different adhesive systems have illustrated that variations in the content can substantially influence the effectiveness of bonding. While in vitro studies provide essential insights, it is imperative that clinical recommendations derive from randomized clinical trials to ensure their reliability and validity. This double-blind, split-mouth, randomized clinical trial was conducted to assess the performance of various universal adhesives over a 24-month period, with a specific emphasis on monomer type, HEMA content, and solvent type, using the selective enamel etch approach in non-carious cervical lesion (NCCL) restorations. Thirty-two participants with two-hundred-fifty-six NCCLs were assigned to the two groups (n = 128): G-Premio Bond (GPB; GC) and Single Bond Universal (SBU; 3 M ESPE). The same composite resin (Essentia, GC) was used. Restorations were assessed at baseline, 12-month, and 24-month using the Revised FDI criteria by two blinded calibrated examiners. Statistical analysis included Fisher’s Exact Chi-Square test, Continuity (Yates) Correction, and McNemar tests (p < 0.05). The 24-month success rate was 98.2%, with the loss of retention in four restorations—two from SBU and two from GPB. Throughout all evaluation periods, no significant differences were identified between the adhesives regarding any criteria (p > 0.05). Both adhesives exhibited a significant decline in marginal adaptation at both the 12-month and 24-month evaluations, as well as an increase in marginal staining at the 24-month interval (p < 0.05). Notwithstanding the observed decrease in marginal adaptation after 24 months, all restorations remained clinically acceptable and were classified as clinically satisfactory. A clinical analysis over a 24-month period demonstrated that variations in the composition of universal adhesives—specifically concerning monomer types, HEMA content, and solvent type—did not significantly affect the performance of NCCL restorations. Notably, all retained restorations met clinical acceptability standards. The clinical trial was registered on 13/01/2021 at https//clinicaltrials.gov with the ID (NCT04707898).
- 22 October 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-12
Open AccessClinical evaluation of different solvent type and HEMA-content of universal adhesive systems in non-carious cervical lesions: a two-year double-blind split-mouth randomized clinical trial
Comparative analyses of different adhesive systems have illustrated that variations in the content can substantially influence the effectiveness of bonding. While in vitro studies provide essential insights, it is imperative that clinical recommendations derive from randomized clinical trials to ensure their reliability and validity. This double-blind, split-mouth, randomized clinical trial was conducted to assess the performance of various universal adhesives over a 24-month period, with a specific emphasis on monomer type, HEMA content, and solvent type, using the selective enamel etch approach in non-carious cervical lesion (NCCL) restorations. Thirty-two participants with two-hundred-fifty-six NCCLs were assigned to the two groups (n = 128): G-Premio Bond (GPB; GC) and Single Bond Universal (SBU; 3 M ESPE). The same composite resin (Essentia, GC) was used. Restorations were assessed at baseline, 12-month, and 24-month using the Revised FDI criteria by two blinded calibrated examiners. Statistical analysis included Fisher’s Exact Chi-Square test, Continuity (Yates) Correction, and McNemar tests (p < 0.05). The 24-month success rate was 98.2%, with the loss of retention in four restorations—two from SBU and two from GPB. Throughout all evaluation periods, no significant differences were identified between the adhesives regarding any criteria (p > 0.05). Both adhesives exhibited a significant decline in marginal adaptation at both the 12-month and 24-month evaluations, as well as an increase in marginal staining at the 24-month interval (p < 0.05). Notwithstanding the observed decrease in marginal adaptation after 24 months, all restorations remained clinically acceptable and were classified as clinically satisfactory. A clinical analysis over a 24-month period demonstrated that variations in the composition of universal adhesives—specifically concerning monomer types, HEMA content, and solvent type—did not significantly affect the performance of NCCL restorations. Notably, all retained restorations met clinical acceptability standards. The clinical trial was registered on 13/01/2021 at https//clinicaltrials.gov with the ID (NCT04707898).
- Open Access
- 21 August 2025
- Published by MDPI AG in Biomimetics
- Vol. 10 (8) , 550
Assessment of Color Stability of Various Flowable Composite Resins with Different Viscosities
Biomimetic restorative dentistry aims to preserve tooth structure and achieve optimal aesthetic harmony with surrounding dentition. The principles and protocols associated with biomimetic restorative dentistry are designed to enhance the longevity of the restoration. The use of flowable CRs is increasingly common; however, the effect of viscosity on the discoloration has not been clearly established. This in vitro study aimed to assess the color stability of flowable CRs with varying viscosities following immersion in common staining solutions and subsequent repolishing. A total of 250 disc-shaped specimens (8 mm × 2 mm) were prepared from five CRs with different viscosity profiles: high-viscosity (Spectra STHV, Dentsply, Milford, DE, USA), medium-viscosity (Estelite Universal Flow Medium, Tokuyama Dental Co., Tokyo, Japan), bulk-fill (Estelite Bulk-Fill Flow, Tokuyama Dental Co., Tokyo, Japan; SDR Plus, Dentsply, Milford, DE, USA), and packable (Estelite Posterior, Tokuyama Dental Co., Tokyo, Japan). After polymerization and baseline color measurements, specimens were immersed in coffee, tea, cola, red wine, or distilled water for 144 h. Color values were recorded before and after staining, and again following repolishing. Color changes (ΔE1, ΔE2, ΔE3) were calculated using the CIE Lab system and statistically analyzed via two-way ANOVA and Tukey HSD (α = 0.05). Both the CR type and the staining solution substantially affected the color change. SDR Plus exhibited the highest ΔE values. Red wine caused the most discoloration. Repolishing enhanced color in selected groups.
- 21 August 2025
- Published by MDPI AG in Biomimetics
- Vol. 10 (8) , 550
Open AccessAssessment of Color Stability of Various Flowable Composite Resins with Different Viscosities
Biomimetic restorative dentistry aims to preserve tooth structure and achieve optimal aesthetic harmony with surrounding dentition. The principles and protocols associated with biomimetic restorative dentistry are designed to enhance the longevity of the restoration. The use of flowable CRs is increasingly common; however, the effect of viscosity on the discoloration has not been clearly established. This in vitro study aimed to assess the color stability of flowable CRs with varying viscosities following immersion in common staining solutions and subsequent repolishing. A total of 250 disc-shaped specimens (8 mm × 2 mm) were prepared from five CRs with different viscosity profiles: high-viscosity (Spectra STHV, Dentsply, Milford, DE, USA), medium-viscosity (Estelite Universal Flow Medium, Tokuyama Dental Co., Tokyo, Japan), bulk-fill (Estelite Bulk-Fill Flow, Tokuyama Dental Co., Tokyo, Japan; SDR Plus, Dentsply, Milford, DE, USA), and packable (Estelite Posterior, Tokuyama Dental Co., Tokyo, Japan). After polymerization and baseline color measurements, specimens were immersed in coffee, tea, cola, red wine, or distilled water for 144 h. Color values were recorded before and after staining, and again following repolishing. Color changes (ΔE1, ΔE2, ΔE3) were calculated using the CIE Lab system and statistically analyzed via two-way ANOVA and Tukey HSD (α = 0.05). Both the CR type and the staining solution substantially affected the color change. SDR Plus exhibited the highest ΔE values. Red wine caused the most discoloration. Repolishing enhanced color in selected groups.
- Open Access
- 28 April 2025
- Published by Necmettin Erbakan Universitesi Dis Hekimligi Dergisi (NEU Dent J), Necmettin Erbakan University in Necmettin Erbakan Universitesi Dis Hekimligi Dergisi (NEUDentJ), Necmettin Erbakan
- Vol. 7 (1) , 97-104
Effects of Whitening Mouthrinses on the Color Recovery of One-shade and Multi-shade Stained Composite Resins
Aim: The aim of the present study was to evaluate the efficacy of mouthrinses on the color recovery of stained one-shade (Charisma Topaz One [CTO]) and multi-shade (Estelite Sigma Quick [ESQ]) composite resins. Methodology: Sixty disc-shaped specimens (8-mm diameterx2-mm thickness) were prepared (n=30 for each composit resin). After polishing (Sof-Lex), the specimens were stored in 37°C for 24h. The specimens were stained by coffee immersion for 168h at 37°C, and then randomized into three subgroups based on the type of mouthrinse (n=10): LAW: Listerine Advanced White; CPWC: Colgate Plax White+Charcoal Capitano Whitening; LTC: Listerine Total Care. Colorimetric measurements were performed at baseline (T0), after staining (T1) and after mouthrinse immersion for 12h at 37°C (T2) with a spectrophotometer (VITA Easy shade). CIELab parameters were used for the analysis. Color change expressed by ΔE and ΔL, Δa, Δb were calculated. The data were subjected to two-way ANOVA, post hoc Tukey, Student t tests (p3.3). CTO showed significantly higher ΔE (12.16±1.37) than ESQ (7.48±0.95) (p=0.001). The mouthrinses led to a distinct increase in the L and decrease in the a and b after staining. LAW and CPWC resulted in significant differences in ΔL (p=0.001), Δb (p=0.031) and ΔE (p=0.002) of ESQ, while causing significant difference in Δb of CTO (p=0.037) at T2-T0. Conclusion: Whitening mouthrinse may reduce the discoloration of coffee-stained composite resins, but not match the initial colour. It provides a better whitening effect in multi-shade composite resin than one-shade composite resins.
- 28 April 2025
- Published by Necmettin Erbakan Universitesi Dis Hekimligi Dergisi (NEU Dent J), Necmettin Erbakan University in Necmettin Erbakan Universitesi Dis Hekimligi Dergisi (NEUDentJ), Necmettin Erbakan
- Vol. 7 (1) , 97-104
Open AccessEffects of Whitening Mouthrinses on the Color Recovery of One-shade and Multi-shade Stained Composite Resins
Aim: The aim of the present study was to evaluate the efficacy of mouthrinses on the color recovery of stained one-shade (Charisma Topaz One [CTO]) and multi-shade (Estelite Sigma Quick [ESQ]) composite resins. Methodology: Sixty disc-shaped specimens (8-mm diameterx2-mm thickness) were prepared (n=30 for each composit resin). After polishing (Sof-Lex), the specimens were stored in 37°C for 24h. The specimens were stained by coffee immersion for 168h at 37°C, and then randomized into three subgroups based on the type of mouthrinse (n=10): LAW: Listerine Advanced White; CPWC: Colgate Plax White+Charcoal Capitano Whitening; LTC: Listerine Total Care. Colorimetric measurements were performed at baseline (T0), after staining (T1) and after mouthrinse immersion for 12h at 37°C (T2) with a spectrophotometer (VITA Easy shade). CIELab parameters were used for the analysis. Color change expressed by ΔE and ΔL, Δa, Δb were calculated. The data were subjected to two-way ANOVA, post hoc Tukey, Student t tests (p3.3). CTO showed significantly higher ΔE (12.16±1.37) than ESQ (7.48±0.95) (p=0.001). The mouthrinses led to a distinct increase in the L and decrease in the a and b after staining. LAW and CPWC resulted in significant differences in ΔL (p=0.001), Δb (p=0.031) and ΔE (p=0.002) of ESQ, while causing significant difference in Δb of CTO (p=0.037) at T2-T0. Conclusion: Whitening mouthrinse may reduce the discoloration of coffee-stained composite resins, but not match the initial colour. It provides a better whitening effect in multi-shade composite resin than one-shade composite resins.
- 26 July 2024
- Published by Elsevier in Journal of Dentistry
- Vol. 149, 105258
5-Year clinical performance of ceramic onlay and overlay restorations luted with light-cured composite resin
- 26 July 2024
- Published by Elsevier in Journal of Dentistry
- Vol. 149, 105258
5-Year clinical performance of ceramic onlay and overlay restorations luted with light-cured composite resin
- 9 August 2023
- Published by Wiley in Australian Endodontic Journal
- Vol. 49 (3) , 574-583
Evaluation of treatment and restoration preferences in deep carious teeth with various pulp exposure sizes: A questionnaire‐based survey
This study evaluated the management preferences in a deep carious vital tooth. A questionnaire was e‐mailed to members of the Turkish Dental Association. The questionnaire included a photograph and radiographs of an extremely deep carious molar (#16) of a 30‐year‐old man suffering from cold and chewing sensitivity. The dentists were asked to choose treatments for pulp exposure of p < 0.05). 504 (4.84%) of 10 411 dentists responded. When the pulp exposure was <1 mm: direct pulp capping (84.9%); 1–2 mm: root canal treatment (49.6%); ≥2 mm: root canal treatment (85.7%) were the most preferred treatments. 69.6% of the respondents chose direct composite restorations. If the tooth would be an abutment, most respondents preferred root canal treatment, regardless of the perforation size. The extent of pulp exposure and the type of permanent restoration influenced the treatment decision‐making process.
- 9 August 2023
- Published by Wiley in Australian Endodontic Journal
- Vol. 49 (3) , 574-583
Evaluation of treatment and restoration preferences in deep carious teeth with various pulp exposure sizes: A questionnaire‐based survey
This study evaluated the management preferences in a deep carious vital tooth. A questionnaire was e‐mailed to members of the Turkish Dental Association. The questionnaire included a photograph and radiographs of an extremely deep carious molar (#16) of a 30‐year‐old man suffering from cold and chewing sensitivity. The dentists were asked to choose treatments for pulp exposure of p < 0.05). 504 (4.84%) of 10 411 dentists responded. When the pulp exposure was <1 mm: direct pulp capping (84.9%); 1–2 mm: root canal treatment (49.6%); ≥2 mm: root canal treatment (85.7%) were the most preferred treatments. 69.6% of the respondents chose direct composite restorations. If the tooth would be an abutment, most respondents preferred root canal treatment, regardless of the perforation size. The extent of pulp exposure and the type of permanent restoration influenced the treatment decision‐making process.
- Open Access
- 15 June 2023
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 10 (4) , 210-217
Evaluation of different adhesive applications on dentine microtensile bond strength
Background: The aim of this study was to evaluate the effect of different adhesive applications on dentine microtensile bond strength (μTBS) in simplified adhesive systems. Methods: Seventy-two extracted non-carious human third molars were randomly divided 18 groups (n=4). Dentin surfaces were polished with #600-grit silicon-carbide paper. Two-step etch&rinse Adper Single Bond2 [SB](3M ESPE) and one-step self-etch Clearfil S3 Bond [S3](Kuraray) were tested, two-step self-etch Clearfil SE Bond [SE](Kuraray) was used as control. The tested adhesives were applied according to the manufacturer’s instructions [MI] or with 2% Chlorhexidine [CHX] or double application of the adhesive [DA] or with hydrophobic resin layer [HR]. Composite build-up (Filtek Ultimate,3MESPE) was restored incrementally and stored in distilled water (24h/37°C). Teeth were sectioned as 1mm2 resin-dentin sticks (Isomet) and subjected to μTBS test (Bisco) immediately [24h] or after six months of water-storage [6M] (Crosshead speed:0.5mm/min.) Data were analyzed by Three-way ANOVA and post-hoc Tukey’s tests (p<0.05). Results: The dentine µTBS was significantly influenced by the adhesive system (p:0.001), adhesive applications (p:0.001), and storage time (p:0.001). The highest μTBS was found in SE-MI (p0.05). The µTBS of all groups decreased significantly at 6M (p<0.01). HR and DA showed significantly higher μTBS than CHX and MI (p0.05). When adhesives were compared, DA and HR were significantly higher μTBS in S3 (p<0.01). Conclusion: HR and DA improved the μTBS while no significant enhancement was observed by CHX. Keywords: Chlorhexidine, dental adhesives, dentin, dentin bonding agents, longevity. Amaç: Bu çalışmanın amacı, basitleştirilmiş adeziv sistemlerde farklı adeziv uygulama tekniklerinin dentine olan mikrogerilim bağlanma dayanımına (μTBS) etkisini değerlendirmektir. Gereç ve Yöntemler: Yetmiş iki adet çekilmiş çürüksüz insan üçüncü büyük azı dişi rastgele 18 gruba ayrıldı (n=4). Dentin yüzeyleri #600-grit silikon-karbit kağıt ile cilalandı. Kontrol grubunu Clearfil SE Bond [SE] (Kuraray), deney gruplarını iki aşamalı etch&rinse Adper Single Bond2 [SB] (3M ESPE) ve tek aşamalı self-etch Clearfil S3 Bond [S3] (Kuraray) oluşturdu. Test edilen adezivler, üretici firmanın talimatları [Kontrol] veya %2 Klorheksidin ile [CHX], veya iki kat adeziv uygulaması ile [x2K] veya ilave hidrofobik reçine tabaka [HR] ile uygulandı. Kompozit blok (Filtek Ultimate, 3M ESPE) tabaklama yöntemiyle oluşturuldu ve distile suda bekletildi (24 saat/37°C). 1mm2 reçine-dentin çubuklarına (Isomet) ayrılarak hemen [24sa] veya 37°C’de altı ay [6.ay] suda bekletildikten sonra μTBS testine tabi tutuldu (Bisco) (Çapraz kafa hızı 0.5 mm/dk). Veriler Three-way ANOVA ve post-hoc Tukey testleri kullanılarak analiz edildi (p0.05). Tüm grupların 6.ay µTBS değerleri anlamlı düzeyde azalmıştır (p<0.01). HR ve x2K, CHX ve Kontrol gruplarından anlamlı düzeyde daha yüksek μTBS sergilerken (p0.05). Adezivler karşılaştırıldığında 6.ayda, x2K ve HR uygulaması S3’de anlamlı düzeyde yüksektir (p<0.01). Sonuçlar: HR ve x2K dentine μTBS değerlerini arttırırken; CHX ile anlamlı düzeyde bir artış gözlenmemiştir. Anahtar kelimeler: Dental adezivler, dentin, dentin yapıştırma ajanları, klorheksidin, uzun ömürlülük
- 15 June 2023
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 10 (4) , 210-217
Open AccessEvaluation of different adhesive applications on dentine microtensile bond strength
Background: The aim of this study was to evaluate the effect of different adhesive applications on dentine microtensile bond strength (μTBS) in simplified adhesive systems. Methods: Seventy-two extracted non-carious human third molars were randomly divided 18 groups (n=4). Dentin surfaces were polished with #600-grit silicon-carbide paper. Two-step etch&rinse Adper Single Bond2 [SB](3M ESPE) and one-step self-etch Clearfil S3 Bond [S3](Kuraray) were tested, two-step self-etch Clearfil SE Bond [SE](Kuraray) was used as control. The tested adhesives were applied according to the manufacturer’s instructions [MI] or with 2% Chlorhexidine [CHX] or double application of the adhesive [DA] or with hydrophobic resin layer [HR]. Composite build-up (Filtek Ultimate,3MESPE) was restored incrementally and stored in distilled water (24h/37°C). Teeth were sectioned as 1mm2 resin-dentin sticks (Isomet) and subjected to μTBS test (Bisco) immediately [24h] or after six months of water-storage [6M] (Crosshead speed:0.5mm/min.) Data were analyzed by Three-way ANOVA and post-hoc Tukey’s tests (p<0.05). Results: The dentine µTBS was significantly influenced by the adhesive system (p:0.001), adhesive applications (p:0.001), and storage time (p:0.001). The highest μTBS was found in SE-MI (p0.05). The µTBS of all groups decreased significantly at 6M (p<0.01). HR and DA showed significantly higher μTBS than CHX and MI (p0.05). When adhesives were compared, DA and HR were significantly higher μTBS in S3 (p<0.01). Conclusion: HR and DA improved the μTBS while no significant enhancement was observed by CHX. Keywords: Chlorhexidine, dental adhesives, dentin, dentin bonding agents, longevity. Amaç: Bu çalışmanın amacı, basitleştirilmiş adeziv sistemlerde farklı adeziv uygulama tekniklerinin dentine olan mikrogerilim bağlanma dayanımına (μTBS) etkisini değerlendirmektir. Gereç ve Yöntemler: Yetmiş iki adet çekilmiş çürüksüz insan üçüncü büyük azı dişi rastgele 18 gruba ayrıldı (n=4). Dentin yüzeyleri #600-grit silikon-karbit kağıt ile cilalandı. Kontrol grubunu Clearfil SE Bond [SE] (Kuraray), deney gruplarını iki aşamalı etch&rinse Adper Single Bond2 [SB] (3M ESPE) ve tek aşamalı self-etch Clearfil S3 Bond [S3] (Kuraray) oluşturdu. Test edilen adezivler, üretici firmanın talimatları [Kontrol] veya %2 Klorheksidin ile [CHX], veya iki kat adeziv uygulaması ile [x2K] veya ilave hidrofobik reçine tabaka [HR] ile uygulandı. Kompozit blok (Filtek Ultimate, 3M ESPE) tabaklama yöntemiyle oluşturuldu ve distile suda bekletildi (24 saat/37°C). 1mm2 reçine-dentin çubuklarına (Isomet) ayrılarak hemen [24sa] veya 37°C’de altı ay [6.ay] suda bekletildikten sonra μTBS testine tabi tutuldu (Bisco) (Çapraz kafa hızı 0.5 mm/dk). Veriler Three-way ANOVA ve post-hoc Tukey testleri kullanılarak analiz edildi (p0.05). Tüm grupların 6.ay µTBS değerleri anlamlı düzeyde azalmıştır (p<0.01). HR ve x2K, CHX ve Kontrol gruplarından anlamlı düzeyde daha yüksek μTBS sergilerken (p0.05). Adezivler karşılaştırıldığında 6.ayda, x2K ve HR uygulaması S3’de anlamlı düzeyde yüksektir (p<0.01). Sonuçlar: HR ve x2K dentine μTBS değerlerini arttırırken; CHX ile anlamlı düzeyde bir artış gözlenmemiştir. Anahtar kelimeler: Dental adezivler, dentin, dentin yapıştırma ajanları, klorheksidin, uzun ömürlülük